Target detection using microwave irradiances from natural sources: A passive, local and global surveillance system

Detection of metal objects on or near the Earth's surface was investigated using existing, passive, microwave sensors operating from Earth orbit. The range equations are derived from basic microwave principles and theories and the expressions are given explicitly to estimate the signal to noise ratio for detecting metal targets operating as bistatic scatterers. Actual measurements are made on a range of metal objects observed from orbit using existing passive microwave receiving systems. The details of the measurements and the results are tabulated and discussed. The advantages of a passive microwave sensor as it is applied to surveillance of metal objects as viewed from aerial platforms or from orbit, are examined.

Stacey, J. M.↗

Un-Numbered Operational Areas PRL 229 Railroad Tie Disposal Area Pond Confirmation Sampling Report

This Confirmatory Sampling (CS) Report (CSR) was prepared for the National Aeronautics and Space Administration (NASA), Kennedy Space Center (KSC), Florida in accordance with the CS Work Plan (CSWP) (HGL, 2022a). The CSR summarizes investigation activities performed on the Railroad Tie Disposal Area (RTDA) of the Un-Numbered Operational Areas (UNOA), Potential Release Location (PRL) 229 located at KSC. HydroGeoLogic, Inc. (HGL) prepared this report under Contract Number 80KSC019D0012. The purpose of the CSR is to provide information to evaluate the level of potential contamination in surface water and sediment samples collected from the RTDA PRL 229 Pond and determine if contaminants pose unacceptable risks to ecological receptors. The CSR provides analytical data of 10 sets of surface water and sediment samples collected in 2021. Surface water samples were analyzed for volatile organic compounds (VOCs), semi-volatile organic compounds (SVOCs), polynuclear aromatic hydrocarbon (PAHs), metals, hardness, and salinity, while sediment samples were analyzed for metals, total organic carbon (TOC), SVOCs, PAHs, and total petroleum hydrocarbons (TPH). The CSR includes a Screening Level Ecological Risk Assessment (SLERA) conducted under KSC’s Resource Conservation and Recovery Act (RCRA) Corrective Action Program to determine if unacceptable risks to ecological receptors exist at PRL 229 Pond. Metals and PAHs were detected in surface water samples, including detections of antimony, arsenic, barium, calcium, copper, lead, magnesium, thallium, zinc, anthracene, benzo(a)anthracene, benzo(a)pyrene, benzo(b)fluoranthene, benzo(g,h,i)perylene, benzo(k)fluoranthene, chrysene, dibenzo(a,h)anthracene, fluoranthene, indeno(1,2,3-c,d)pyrene and pyrene. Based on measured salinity (1.03 to 1.21 parts per thousand), the pond was identified as freshwater. Sediment analytical results also contained detections of metals and PAHs, including antimony, arsenic, barium, beryllium, cadmium, chromium, copper, lead, mercury, nickel, selenium, thallium, zinc, anthracene benzo(a)anthracene, benzo(a)pyrene, benzo(b)fluoranthene, benzo(g,h,i)perylene, benzo(k)fluoranthene, chrysene, dibenzo(a,h)anthracene, fluoranthene, indeno(1,2,3-c,d)pyrene and pyrene. Potential risks to ecological receptors were evaluated in accordance with the SLERA Work Plan and the Decision Process Document for the Resource Conservation and Recovery Act (RCRA) Corrective Action Program at KSC (DPD) (Geosyntec, 2019), and using the 2021 sediment and surface water analytical results. Potential ecological receptors evaluated in the SLERA include the aquatic community, benthic invertebrates, aquatic birds, and aquatic mammals. The SLERA included Steps 2a through 2c of the Ecological Risk Assessment (ERA) process in accordance with the DPD. Using multiple lines of evidence, the SLERA concluded that many of the detected analytes are present at concentrations similar to those in background or reference locations at KSC, and/or at concentrations that would not pose a significant risk to ecological communities. There are no screening values available for the avian community, and PAHs are bioaccumulative compounds. For this reason, food web modeling was completed as a supplement to Step 2c to provide a quantitative evaluation of this exposure pathway. Food web modeling indicates that PAHs are unlikely to pose a risk to birds exposed to site sediment and surface water. Based on the results of the SLERA, the contaminants in sediment and surface water pose no to minimal risk to the ecological communities that could live or forage at the site. Based on the results of the SLERA, no further study is recommended for the RTDA Pond at PRL 229.

Confirmation Sampling↗

Radially Focused Eddy Current Sensor for Detection of Longitudinal Flaws in Metallic Tubes

A radially focused eddy current sensor detects longitudinal flaws in a metal tube. A drive coil induces eddy currents within the wall of the metal tube. A pick-up cod is spaced apart from the drive coil along the length of the metal tube. The pick@up coil is positioned with one end thereof lying adjacent the wall of the metal tube such that the pick-up coil's longitudinal axis is perpendicular to the wall of the metal tube. To isolate the pick-up coil from the magnetic flux of the drive coil and the flux from the induced eddy currents. except the eddy currents diverted by a longitudinal flaw. an electrically conducting material high in magnetic permeability surrounds all of the pick-up coil except its one end that is adjacent the walls of the metal tube. The electrically conducting material can extend into and through the drive coil in a coaxial relationship therewith.

Wincheski, Russell A.↗

Consistent Practices for the Probability of Detection (POD) of Fracture Critical Metallic Components Project

NASA-STD-5009 requires that successful flaw detection by NDE methods be statistically qualified for use on fracture critical metallic components, but does not standardize practices. This task works towards standardizing calculations and record retention with a web-based tool, the NNWG POD Standards Library or NPSL. Test methods will also be standardized with an appropriately flexible appendix to -5009 identifying best practices. Additionally, this appendix will describe how specimens used to qualify NDE systems will be cataloged, stored and protected from corrosion, damage, or loss.

Hughitt, Brian↗

Metal fatigue damage - Mechanism, detection, avoidance, and repair.

Collection of theoretical and experimental studies covering basic mechanisms of fatigue in the subcreep and creep ranges, fatigue damage detection, field practices for fatigue damage repair in jet engine components, and fatigue damage avoidance and control. Individual items are abstracted in this issue.

Manson, S. S.↗

Detecting Cracks in Rough Metal Surfaces

Test based on eddy-current probe technique identifies cracks in swaged metals. Hinged collar with spring-loaded latch holds probe in place on part tested. For repeated measurements on same or similar parts, collar loosened and moved to various measuring positions. Method suitable for many kinds of metal parts, including swaged fittings, tubing, and pipes. Used for rapid crack/no-crack determinations in suspect parts already installed.

Zuver, N. T.↗

Uncertainty in Calibration, Detection and Estimation of Metal Concentrations in Engine Plumes Using OPAD

Improvements in uncertainties in the values of radiant intensity (I) can be accomplished mainly by improvements in the calibration process and in minimizing the difference between the background and engine plume radiance. For engine tests in which the plume is extremely bright, the difference in luminance between the calibration lamp and the engine plume radiance can be so large as to cause relatively large uncertainties in the values of R. This is due to the small aperture necessary on the receiving optics to avoid saturating the instrument. However, this is not a problem with the SSME engine since the liquid oxygen/hydrogen combustion is not as bright as some other fuels. Applying the instrumentation to other type engine tests may require a much brighter calibration lamp.

Hopkins, Randall C.↗

In Situ Measurements of Meteoric Ions

Metal ions found in the atmosphere above 60 km are the result of incoming meteoroid atmospheric ablation. Layers of metal ions are detected by sounding rocket in situ mass spectrometric sampling in the 80 to 130 km region, which coincides with the altitude region where meteors are observed. Enhancements of metal ion concentrations occur during meteor showers. Even outside of shower periods, the metal ion altitude profiles vary from measurement to measurement. Double layers are frequent at middle latitudes. More than 40 different meteoric atomic and molecular ions, including isotopes, have been detected. Atmospheric metal ions on average have an abundance that matches chrondritic material, the same composition as the early solar system. However there are frequently local departures from this composition due to differential ablation, species dependent chemistry and mass dependent ion transport. Metal ions react with atmospheric O2, O, O3, H2O and H2O2 to form oxygenated and hydrogenated ionic compounds. Metal atomic ions at high altitudes have long lifetimes. As a result, these ions, in the presence of Earth's magnetic field, are transported over long distances by upper atmospheric winds and ionospheric electric fields. Satellite measurements have detected metal ions as high as, approximately 1000 km and have revealed circulation of the ions on a global scale.

Grebowsky, Joseph M.↗

Simple Method For Detection Of Intergranular Attack

Evidence of intergranular attack occurring on chemically milled and wire-electrical-discharge-machined metal parts detected with replicating tape which makes it unnecessary to manufacture and stock test coupons and inspect them microscopically. Tape pressed on part to be inspected. When removed, it presents visual evidence of intergranular attack.

Jackson, Amy A.↗

Optical Production and Detection of Ultrasonic Waves in Metals for Nondestructive Testing

Ultrasonic waves were produced by striking the surface of a metal with the focused one-joule pulse of a Q-switched ruby laser. Rayleigh (surface) waves and longitudinal waves were detected with conventional transducers. Optical methods of detection were tested and developed. Rayleigh waves were produced with an oscillator and transducer. They were optically detected on curved polished surfaces, and on unpolished surfaces. The technique uses a knife edge to detect small angle changes of the surface as the wave pulse passes the illuminated spot. Optical flaw detection using pulse echo and attenuation is demonstrated.

Morrison, R. A.↗

The Lunar Atmosphere: History, Status, Current Problems, and Context

After decades of speculation and fruitless searches, the lunar atmosphere was first observed by Apollo surface and orbital instruments between 1970 and 1972. With the demise of Apollo in 1972, and the termination of funding for Apollo lunar ground station studies in 1977, the field withered for many years, but has recently enjoyed a renaissance. This reflowering has been driven by the discovery and exploration of sodium and potassium in the lunar exosphere by groundbased observers, the detection of metal ions derived from the Moon in interplanetary space, the possible discoveries of H2O ice at the poles of the Moon and Mercury, and the detections of tenuous atmospheres around more remote sites in the solar system, including Mercury and the Galilean satellites. In this review we summarize the present state of knowledge about the lunar atmosphere, describe the important physical processes taking place within it, and then discuss related topics including a comparison of the lunar atmosphere to other surface boundary exospheres in the solar system.

Stern, S. Alan .↗

Spoof Plasmon Polaritons for NDE Applications an Experimental Demonstration

NASA is exploring the use of microwave spoof plasmon polaritons to detect defects in metallic structures. This work investigates the detection of simulated defects in the form of aluminum wires as small as 1.6 mm diameter and 2mm long that are placed in a grooved aluminum test article. The inclusions simulate manufacturing defects, and the sum of the delta impedance is shown to increase with increasing volume of added metal. A threshold value of 50Ω has been proposed for defect detection. In addition to detecting defects, the technique also estimates the volume of the defect.

Microwave↗

Preliminary Results From a Heavily Instrumented Engine Ice Crystal Icing Test in a Ground Based Altitude Test Facility

Preliminary results from the Heavily Instrumented ALF503R-5 Engine test conducted in the NASA Glenn Research Center Propulsion Systems Laboratory will be discussed. The effects of ice crystal icing on a full scale engine is examined and documented. This model engine, serial number LF01, was used during the inaugural icing test in the PSL facility. The reduction of thrust (rollback) events experienced by this engine in flight were replicated in the facility. Limited instrumentation was used to detect icing. Metal temperature on the exit guide vanes and outer shroud and the load measurement were the only indicators of ice formation. The current study features a similar engine, serial number LF11, which is instrumented to characterize the cloud entering the engine, detect characterize ice accretion, and visualize the ice accretion in the region of interest.

enigine icing↗

A Comparison of the Capability of Sensitivity Level 3 and Sensitivity Level 4 Fluorescent Penetrants to Detect Fatigue Cracks in Various Metals

In April 2008, NASA-STD-5009 established a requirement that only sensitivity level 4 penetrants are acceptable for NASA Standard Level liquid penetrant inspections. Having NASA contractors change existing processes or perform demonstration tests to certify sensitivity level 3 penetrants posed a potentially huge cost to the Agency. This study was conducted to directly compare the probability of detection (POD) of sensitivity level 3 and level 4 penetrants using both Method A and Method D inspection processes. POD demonstration tests were performed on 6061-Al, Haynes 188 and Ti-6Al-4V crack panel sets. The study results strongly support the conclusion that sensitivity level 3 penetrants are acceptable for NASA Standard Level inspections.

Parker, Bradford H.↗

Spoof Plasmon Sensing for NDE Application

NASA is exploring the use of microwave spoof plasmon polaritons to detect defects in metallic structures. This work investigates the detection of simulated defects in the form of aluminum wires as small as 1.6 mm diameter and 2 mm long that are placed in a grooved aluminum test article. The inclusions simulate manufacturing defects, and the sum of the delta impedance is shown to increase with increasing volume of added metal. Based on the results, a threshold value of 50Ω has been proposed for defect detection. In addition to detecting defects, the technique also estimates the volume of the defect.

Microwave↗

Method and Apparatus for the Detection of Hydrogen Using a Metal Alloy

A hydrogen sensitive metal alloy contains palladium and titanium to provide a larger change in electrical resistance when exposed to the presence of hydrogen. The alloy is deposited on a substrate and a thin film and connected across electrical circuitry to provide a sensor device that can be used for improved sensitivity and accuracy of hydrogen detection.

Hunter, Gary W.↗