Search NASA⌕ Search

SEARCH · Search NASA

Results for “microdosimetry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Comparison of Geant4-DNA and RITRACKS/RITCARD: Microdosimetry, Nanodosimetry and DNA Damage Predictions for Low to High LET Ions

Low linear energy transfer (LET) ionizing radiations induce homogeneously distributed DNA damage at the cellular scale, while high LET ionizing radiations are well known to create complex biological damage including clustered double strand breaks (DSB). Clustered DSB are critical events that are difficult to repair, leading to increased biological outcomes compared to low LET radiation exposure. Recent studies have shown that DNA compaction, which can be actively modified by the cell to allow DNA repair, influences the yield of DSB [1]. The goal of this work is to determine the impact of DNA compaction on chromosome aberration formation, a biomarker of radiation-induced cancer risk. The RITRACKS track structure code [2], together with the RITCARD code [3], allow one to simulate the transport of high LET ions, calculate DNA damage and repair, and chromosome aberration formation, but does not include detailed geometrical models of DNA. The Geant4-DNA toolkit provides such detailed models with different levels of DNA compaction [1,4], but does not model chromosome aberration formation. In this work, these highly detailed DNA geometries are used to compute DNA breaks with Geant4-DNA and combine the results with the RITCARD tool to compute chromosome aberrations. As a first step, we compared the transport models used in RITRACKS and Geant4-DNA and newly released heavy ion model transport (G4DNARuddIonisationExtendedModel Geant4 v11.2) to ensure consistency between the physical stage of the two radiation transport codes. We compared energy deposition at the micrometric and nanometric scales for different ions (H 250 MeV, H 150 Me, He 250 MeV/n, C 290 MeV/n, O 350 MeV/n, O 55 MeV/n, Si 170MeV/n, Ti 300 MeV/n, Ti 300 MeV/n, Fe 600 MeV/n, Fe 450 MeV/n and Fe 300 MeV/n) with LET ranging from ~0.4 keV/μm up to 235 keV/μm. Excellent agreement is found for both microdosimetric and nanodosimetric spectra for all ion types and energies. The calculation of DNA breaks and their complexity with the Geant4-DNA is an ongoing work, and comparison with RITCARD will be presented based on result availability at the time of the conference. [1] Tang et al. (2019). Med. Phys., 46(3), 1501-1511. [2] Plante et al. (2008). NJP, 10(12), 125020. [3] Plante et al. (2019). Rad. Res., 192(3), 282-298. [4] Incerti et al. (2018). Med. Phys., 45(8), e722-e739.

Floriane Poignant↗

Comparison of GEANT4 very low energy cross section models with experimental data in water

Purpose: The GEANT4 general-purpose Monte Carlo simulation toolkit is able to simulate physical interaction processes of electrons, hydrogen and helium atoms with charge states (H{sup 0}, H{sup +}) and (He{sup 0}, He{sup +}, He{sup 2+}), respectively, in liquid water, the main component of biological systems, down to the electron volt regime and the submicrometer scale, providing GEANT4 users with the so-called ''GEANT4-DNA'' physics models suitable for microdosimetry simulation applications. The corresponding software has been recently re-engineered in order to provide GEANT4 users with a coherent and unique approach to the simulation of electromagnetic interactions within the GEANT4 toolkit framework (since GEANT4 version 9.3 beta). This work presents a quantitative comparison of these physics models with a collection of experimental data in water collected from the literature. Methods: An evaluation of the closeness between the total and differential cross section models available in the GEANT4 toolkit for microdosimetry and experimental reference data is performed using a dedicated statistical toolkit that includes the Kolmogorov-Smirnov statistical test. The authors used experimental data acquired in water vapor as direct measurements in the liquid phase are not yet available in the literature. Comparisons with several recommendations are also presented. Results: The authors have assessed the compatibility of experimental data with GEANT4 microdosimetry models by means of quantitative methods. The results show that microdosimetric measurements in liquid water are necessary to assess quantitatively the validity of the software implementation for the liquid water phase. Nevertheless, a comparison with existing experimental data in water vapor provides a qualitative appreciation of the plausibility of the simulation models. The existing reference data themselves should undergo a critical interpretation and selection, as some of the series exhibit significant deviations from each other. Conclusions: The GEANT4-DNA physics models available in the GEANT4 toolkit have been compared in this article to available experimental data in the water vapor phase as well as to several published recommendations on the mass stopping power. These models represent a first step in the extension of the GEANT4 Monte Carlo toolkit to the simulation of biological effects of ionizing radiation.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-T-78: Comparison of Dose-Averaged Linear Energy Transfer Calculation Methods Used in Monte Carlo Simulations of Clinical Proton Beams

Purpose: To evaluate the differences in dose-averaged linear energy transfer (LETd) maps calculated in water by means of different strategies found in the literature in proton therapy Monte Carlo simulations and to compare their values with dose-mean lineal energy microdosimetry calculations. Methods: The Geant4 toolkit (version 9.6.2) was used. Dose and LETd maps in water were scored for primary protons with cylindrical voxels defined around the beam axis. Three LETd calculation methods were implemented. First, the LETd values were computed by calculating the unrestricted linear energy transfer (LET) associated to each single step weighted by the energy deposition (including delta-rays) along the step. Second, the LETd was obtained for each voxel by computing the LET along all the steps simulated for each proton track within the voxel, weighted by the energy deposition of those steps. Third, the LETd was scored as the quotient between the second momentum of the LET distribution, calculated per proton track, over the first momentum. These calculations were made with various voxel thicknesses (0.2 – 2.0 mm) for a 160 MeV proton beamlet and spread-out Bragg Peaks (SOBP). The dose-mean lineal energy was calculated in a uniformly-irradiated water sphere, 0.005 mm radius. Results: The value of the LETd changed systematically with the voxel thickness due to delta-ray emission and the enlargement of the LET distribution spread, especially at shallow depths. Differences of up to a factor 1.8 were found at the depth of maximum dose, leading to similar differences at the central and distal depths of the SOBPs. The third LETd calculation method gave better agreement with microdosimetry calculations around the Bragg Peak. Conclusion: Significant differences were found between LETd map Monte Carlo calculations due to both the calculation strategy and the voxel thickness used. This could have a significant impact in radiobiologically-optimized proton therapy treatments.

07 ISOTOPE AND RADIATION SOURCES↗

Quantitative single-particle digital autoradiography with α-particle emitters for targeted radionuclide therapy using the iQID camera

Purpose: Alpha-emitting radionuclides exhibit a potential advantage for cancer treatments because they release large amounts of ionizing energy over a few cell diameters (50–80 μm), causing localized, irreparable double-strand DNA breaks that lead to cell death. Radioimmunotherapy (RIT) approaches using monoclonal antibodies labeled with α emitters may thus inactivate targeted cells with minimal radiation damage to surrounding tissues. Tools are needed to visualize and quantify the radioactivity distribution and absorbed doses to targeted and nontargeted cells for accurate dosimetry of all treatment regimens utilizing α particles, including RIT and others (e.g., Ra-223), especially for organs and tumors with heterogeneous radionuclide distributions. The aim of this study was to evaluate and characterize a novel single-particle digital autoradiography imager, the ionizing-radiation quantum imaging detector (iQID) camera, for use in α-RIT experiments. Methods: The iQID camera is a scintillator-based radiation detection system that images and identifies charged-particle and gamma-ray/x-ray emissions spatially and temporally on an event-by-event basis. It employs CCD-CMOS cameras and high-performance computing hardware for real-time imaging and activity quantification of tissue sections, approaching cellular resolutions. In this work, the authors evaluated its characteristics for α-particle imaging, including measurements of intrinsic detector spatial resolutions and background count rates at various detector configurations and quantification of activity distributions. The technique was assessed for quantitative imaging of astatine-211 ({sup 211}At) activity distributions in cryosections of murine and canine tissue samples. Results: The highest spatial resolution was measured at ∼20 μm full width at half maximum and the α-particle background was measured at a rate as low as (2.6 ± 0.5) × 10{sup −4} cpm/cm{sup 2} (40 mm diameter detector area). Simultaneous imaging of multiple tissue sections was performed using a large-area iQID configuration (ø 11.5 cm). Estimation of the {sup 211}At activity distribution was demonstrated at mBq/μg-levels. Conclusions: Single-particle digital autoradiography of α emitters has advantages over traditional film-based autoradiographic techniques that use phosphor screens, in terms of spatial resolution, sensitivity, and activity quantification capability. The system features and characterization results presented in this study show that the iQID is a promising technology for microdosimetry, because it provides necessary information for interpreting alpha-RIT outcomes and for predicting the therapeutic efficacy of cell-targeted approaches using α emitters.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cancer Risk Assessment for Space Radiation

Predicting the occurrence of human cancer following exposure to any agent causing genetic damage is a difficult task. This is because the uncertainty of uniform exposure to the damaging agent, and the uncertainty of uniform processing of that damage within a complex set of biological variables, degrade the confidence of predicting the delayed expression of cancer as a relatively rare event within any given clinically normal individual. The radiation health research priorities for enabling long-duration human exploration of space were established in the 1996 NRC Report entitled 'Radiation Hazards to Crews of Interplanetary Missions: Biological Issues and Research Strategies'. This report emphasized that a 15-fold uncertainty in predicting radiation-induced cancer incidence must be reduced before NASA can commit humans to extended interplanetary missions. That report concluded that the great majority of this uncertainty is biologically based, while a minority is physically based due to uncertainties in radiation dosimetry and radiation transport codes. Since that report, the biologically based uncertainty has remained large, and the relatively small uncertainty associated with radiation dosimetry has increased due to the considerations raised by concepts of microdosimetry. In a practical sense, however, the additional uncertainties introduced by microdosimetry are encouraging since they are in a direction of lowered effective dose absorbed through infrequent interactions of any given cell with the high energy particle component of space radiation. Additional information is contained in the original extended abstract.

Richmond, Robert C.↗

Cancer Risk Assessment for Space Radiation

Predicting the occurrence of human cancer following exposure to any agent causing genetic damage is a difficult task. This is because the uncertainty of uniform exposure to the damaging agent, and the uncertainty of uniform processing of that damage within a complex set of biological variables, degrade the confidence of predicting the delayed expression of cancer as a relatively rare event within any given clinically normal individual. The radiation health research priorities for enabling long-duration human exploration of space were established in the 1996 NRC Report entitled "Radiation Hazards to Crews of Interplanetary Missions: Biological Issues and Research Strategies". This report emphasized that a 15-fold uncertainty in predicting radiation-induced cancer incidence must be reduced before NASA can commit humans to extended interplanetary missions. That report concluded that the great majority of this uncertainty is biologically based, while a minority is physically based due to uncertainties in radiation dosimetry and radiation transport codes. Since that report, the biologically based uncertainty has remained large, and the relatively small uncertainty associated with radiation dosimetry has increased due to the considerations raised by concepts of microdosimetry. In a practical sense, however, the additional uncertainties introduced by microdosimetry are encouraging since they are in a direction of lowered effective dose absorbed through infrequent interactions of any given cell with the high energy particle component of space radiation. The biological uncertainty in predicting cancer risk for space radiation derives from two primary facts. 1) One animal tumor study has been reported that includes a relevant spectrum of particle radiation energies, and that is the Harderian gland model in mice. Fact #1: Extension of cancer risk from animal models, and especially from a single study in an animal model, to humans is inherently uncertain. 2) One human database is predominantly used for assessing cancer risk caused by space radiation, and that is the Japanese atomic bomb survivors. Fact #2: The atomic-bomb-survivor database, itself a remarkable achievement, contains uncertainties. These include the actual exposure to each individual, the radiation quality of that exposure, and the fact that the exposure was to acute doses of predominantly low-LET radiation, not to chronic exposures of high-LET radiation expected on long-duration interplanetary manned missions.

Richmond, Robert C.↗

DNA Repair Domain Modeling Can Predict Cell Death and Mutation Frequency for Wide Range Spectrum of Radiation

Exploration missions to Mars and other destinations raise many questions about the health of astronauts. The continuous exposure of astronauts to galactic cosmic rays is one of the main concerns for long-term missions. Cosmic ionizing radiations are composed of different ions of various charges and energies notably, highly charged energy (HZE) particles. The HZE particles have been shown to be more carcinogenic than low-LET radiation, suggesting the severity of chromosomal aberrations induced by HZE particles is one possible explanation. However, most mathematical models predicting cell death and mutation frequency are based on directly fitting various HZE dose response and are in essence empirical approaches. In this work, we assume a simple biological mechanism to model DNA repair and use it to simultaneously explain the low- and high-LET response using the exact same fitting parameters. Our work shows that the geometrical position of DNA repair along tracks of heavy ions are sufficient to explain why high-LET particles can induce more death and mutations. Our model is based on assuming DNA double strand breaks (DSBs) are repaired within repair domain, and that any DSBs located within the same repair domain cluster into one repair unit, facilitating chromosomal rearrangements and increasing the probability of cell death. We introduced this model in 2014 using simplified microdosimetry profiles to predict cell death. In this work, we collaborated with NASA Johnson Space Center to generate more accurate microdosimetry profiles derived by Monte Carlo techniques, taking into account track structure of HZE particles and simulating DSBs in realistic cell geometry. We simulated 224 data points (D, A, Z, E) with the BDSTRACKS model, leading to a large coverage of LET from ~10 to 2,400 keV/μm. This model was used to generate theoretical RBE for various particles and energies for both cell death and mutation frequencies. The RBE LET dependence is in agreement with experimental data known in human and murine cells. It suggests that cell shape and its orientation with respect to the HZE particle beam can modify the biological response to radiation. Such discovery will be tested experimentally and, if proven accurate, will be another strong supporting evidence for DNA repair domains and their critical role in interpreting cosmic radiation sensitivity.

Viger, Louise↗

Track Structure Components: Characterizing Energy Deposition from Direct and Peripheral Hits in Spherical Cells

Energy deposition by ionizing radiation in micrometric targets (microdosimetry), representative of cells, is very important to understand the effect of radiation and the cellular and biological response. Microdosimetry is used to estimate quality factors for risk assessment in radiation protection and quantify Relative Biological Effectiveness (RBE) for treatment planning of hadron radiation therapy. Radiation physics has shown that ionizing radiation deposit their energy in a complex manner, the track structure. Consequently, energy deposited in a target is a function of factors like the ion type, its energy and the irradiated volume.

Ianik Plante↗

Confocal Microscopy for Modeling Electron Microbeam Irradiation of Skin

For radiation exposures employing targeted sources such as particle microbeams, the deposition of energy and dose will depend on the spatial heterogeneity of the spample. Although cell structural variations are relatively minor for two-dimensional cell cultures, they can vary significantly for fully differential tissues. Employing high-resolution confocal microscopy, we have determined the spatial distribution, size, and shape of epidermal kerantinocyte nuclei for the full-thickness EpiDerm skin model (MatTek, Ashland, VA). Application of these data to claculate the microdosimetry and microdistribution of energy deposition by an electron microbeam is discussed.

59 BASIC BIOLOGICAL SCIENCES↗

Localized Dose Enhancement to Tumor Blood Vessel Endothelial Cells via Megavoltage X-rays and Targeted Gold Nanoparticles: New Potential for External Beam Radiotherapy

Purpose: Tumor endothelial cell damage during radiation therapy may contribute significantly to tumor eradication and treatment efficacy. Gold nanoparticles (AuNPs) delivered preferentially to the walls of tumor blood vessels produce low-energy, short-range photoelectrons during external beam radiotherapy, boosting dose to the tumor microvasculature. In this study dosimetry at the single-cell level is used to estimate the anticipated AuNP-mediated dose enhancement to tumor endothelial cells during 6-MV X-ray irradiation. Methods and Materials: Endothelial cells are modeled as thin slabs with 100-nm-diameter AuNPs attached within the blood vessel. The number of photoelectrons emitted per AuNP per gray of X-rays is computed at multiple points along the external beam central axis by use of a Monte Carlo-generated energy fluence spectrum. The energy deposited from AuNP emissions to the endothelium is calculated based on an analytic method incorporating the energy-loss formula of Cole. The endothelial dose enhancement factor (EDEF) is the ratio of the overall (externally plus internally generated) dose to endothelial cells in the presence of AuNPs to the dose without AuNPs (from the external beam only). Results: At 20-cm depth, the EDEF is 1.7 (70% dose increase) for an intravascular AuNP concentration of 30 mg/g. Most of this dose enhancement arises from the low-energy (approximately 100 keV) portion of the linear accelerator X-ray spectrum. Furthermore, for AuNP concentrations ranging from 7 to 140 mg/g, EDEF values of 1.2 to 4.4 (20-340% dose increase) are calculated. Conclusions: In contrast to calculations assuming that AuNPs distributed homogeneously throughout the target volume (macrodosimetry), our cellular microdosimetry calculations predict a major dose enhancement to tumor microvasculature from conventional linear accelerator X-rays. This effect may enable the delivery of ablative therapeutic doses to these sensitive microstructures while maintaining established dose constraints for the organs at risk.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Silicon-based three-dimensional microstructures for radiation dosimetry in hadrontherapy

In this work, we propose a solid-state-detector for use in radiation microdosimetry. This device improves the performance of existing dosimeters using customized 3D-cylindrical microstructures etched inside silicon. The microdosimeter consists of an array of micro-sensors that have 3D-cylindrical electrodes of 15 μm diameter and a depth of 5 μm within a silicon membrane, resulting in a well-defined micrometric radiation sensitive volume. These microdetectors have been characterized using an {sup 241}Am source to assess their performance as radiation detectors in a high-LET environment. This letter demonstrates the capability of this microdetector to be used to measure dose and LET in hadrontherapy centers for treatment plan verification as part of their patient-specific quality control program.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

RBE estimation of proton radiation fields using a {Delta}E-E telescope

A new monolithic silicon {Delta}E-E telescope was evaluated in unmodulated and modulated 100 MeV proton beams used for hadron therapy. Compared to a classical microdosimetry detector, which provides one-dimensional information on lineal energy of charged particles, this detector system provides two-dimensional information on lineal energy and particle energy based on energy depositions, collected in coincidence, within the {Delta}E and E stages of the detector. The authors investigated the possibility to use the information obtained with the {Delta}E-E telescope to determine the relative biological effectiveness (RBE) at defined locations within the proton Bragg peak and spread-out Bragg peak (SOBP). An RBE matrix based on the established in vitro V79 cell survival data was developed to link the output of the device directly to RBE({alpha}), the RBE in the low-dose limit, at various depths in a homogeneous polystyrene phantom. In the SOBP of a 100 MeV proton beam, the RBE({alpha}) increased from 4.04 proximal to the SOBP to a maximum value of 5.4 at the distal edge. The {Delta}E-E telescope, with its high spatial resolution, has potential applications to biologically weighted hadron treatment planning as it provides a compact and portable means for estimating the RBE in rapidly changing hadron radiation fields within phantoms.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Microdosimetric study on influence of low energy photons on relative biological effectiveness under therapeutic conditions using 6 MV linac

Purpose: Microdosimetry has been developed for the evaluation of radiation quality, and single-event dose-mean lineal energy y{sub D} is well-used to represent the radiation quality. In this study, the changes of the relative biological effectiveness (RBE) values under the therapeutic conditions using a 6 MV linac were investigated with a microdosimetric method. Methods: The y{sub D} values under the various irradiation conditions for x-rays from a 6 MV linac were measured with a tissue-equivalent proportional counter (TEPC) at an extremely low dose rate of a few tens of {mu}Gy/min by decreasing the gun grid voltage of the linac. According to the microdosimetric kinetic model (MK model), the RBE{sub MK} values for cell killing of the human salivary gland (HSG) tumor cells can be derived if the y{sub D} values are obtained from TEPC measurements. The Monte Carlo code GEANT4 was also used to calculate the photon energy distributions and to investigate the changes of the y{sub D} values under the various conditions. Results: The changes of the y{sub D} values were less than approximately 10% when the field size and the depth in a phantom varied. However, in the measurements perpendicular to a central beam axis, large changes were observed between the y{sub D} values inside the field and those outside the field. The maximum increase of approximately 50% in the y{sub D} value outside the field was obtained compared with those inside the field. The GEANT4 calculations showed that there existed a large relative number of low energy photons outside of the field as compared with inside of the field. The percentages of the photon fluences below 200 keV outside the field were approximately 40% against approximately 8% inside the field. By using the MK model, the field size and the depth dependence of the RBE{sub MK} values were less than approximately 2% inside the field. However, the RBE{sub MK} values outside the field were 6.6% higher than those inside the field. Conclusions: The increase of the RBE{sub MK} values by 6.6% outside the field was observed. This increase is caused by the change of the photon energy distributions, especially the increase of the relative number of low energy photons outside the field.

43 PARTICLE ACCELERATORS↗

Gold nanoparticle-aided brachytherapy with vascular dose painting: Estimation of dose enhancement to the tumor endothelial cell nucleus

Purpose: Theoretical microdosimetry at the subcellular level is employed in this study to estimate the dose enhancement to tumor endothelial cell nuclei, caused by radiation-induced photo/Auger electrons originating from gold nanoparticles (AuNPs) targeting the tumor endothelium, during brachytherapy. Methods: A tumor vascular endothelial cell (EC) is modeled as a slab of 2 {mu}m (thickness) x 10 {mu}m (length) x 10 {mu}m (width). The EC contains a nucleus of 5 {mu}m diameter and thickness of 0.5-1 {mu}m, corresponding to nucleus size 5%-10% of cellular volume, respectively. Analytic calculations based on the electron energy loss formula of Cole were carried out to estimate the dose enhancement to the nucleus caused by photo/Auger electrons from AuNPs attached to the exterior surface of the EC. The nucleus dose enhancement factor (nDEF), representing the ratio of the dose to the nucleus with and without the presence of gold nanoparticles was calculated for different AuNP local concentrations. The investigated concentration range considers the potential for significantly higher local concentration near the EC due to preferential accumulation of AuNP in the tumor vasculature. Four brachytherapy sources: I-125, Pd-103, Yb-169, and 50 kVp x-rays were investigated. Results: For nucleus size of 10% of the cellular volume and AuNP concentrations ranging from 7 to 140 mg/g, brachytherapy sources Pd-103, I-125, 50 kVp, and Yb-169 yielded nDEF values of 5.6-73, 4.8-58.3, 4.7-56.6, and 3.2-25.8, respectively. Meanwhile, for nucleus size 5% of the cellular volume in the same concentration range, Pd-103, I-125, 50 kVp, and Yb-169 yielded nDEF values of 6.9-79.2, 5.1-63.2, 5.0-61.5, and 3.3-28.3, respectively. Conclusions: The results predict that a substantial dose boost to the nucleus of endothelial cells can be achieved by applying tumor vasculature-targeted AuNPs in combination with brachytherapy. Such vascular dose boosts could induce tumor vascular shutdown, prompting extensive tumor cell death.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-26: A Study On the Influence of Photonuclear Reactions On the Biological Effectiveness of Therapeutic High Energy X-Ray Beam

Purpose: Photons from a modern high-energy therapeutic linear accelerator used in X-ray radiotherapy causes photonuclear reactions in an accelerator or patient's body. The aim of this study is to evaluate the biological effectiveness including these particles by Microdosimetric Kinetic Model (MKM) based on microdosimetry. Methods: A linear accelerator operating at 15 MV was used. CR-39 was used to obtain LET spectra of secondary ions selectively, as CR-39 is regarded insensitive to photons. CR-39 was put on the central axis of the X-ray beam at depths of 0, 5 and 10 cm in plastic phantom at a source to detector distance of 100 cm. Pits formed by the traversal of ions were etched then analyzed to obtain restricted LET distribution. Frequency-mean and dose-mean lineal energy was evaluated from the relationship between the restricted LET and the lineal energy required to evaluate the biological effectiveness by MKM. The relationship was calculated by Monte Carlo simulations with GEANT4. Results: Restricted LET distributions of secondary particles showed broad distributions that decreases exponentially with increasing LET. Frequency-mean and dose-mean lineal energy were determined uniquely within the scope of the energies of secondary particles generated from photons of 15 MeV. The frequency-mean lineal energies at the depth of 0, 5 and 10 cm were 15.1, 16.0 and 19.7 keV/μm respectively, and the dose-mean lineal energies were 18.6, 20.5 and 19.6 keV/μm, respectively. RBE of secondary particles for HSG cell evaluated by MKM was about 2.0 at all depths, and RBE of all particles including photons was evaluated 1.0. Conclusion: We investigated the biological effectiveness of secondary particles by photonuclear reactions. The method to evaluate RBE by MKM was established with measurements and simulations. However, the influence of these secondary ions on RBE was found negligible in the entire biological effectiveness of the high-energy X-ray. This study has been supported by JSPS KAKENHI Grant Number 25861144.

60 APPLIED LIFE SCIENCES↗

SU-E-T-81: Comparison of Microdosimetric Quantities Calculated Using the Track Structure Monte Carlo Algorithms Geant4-DNA and NOREC

Purpose: Microdosimetric quantities, such as the lineal energy, have been shown to correlate with the biological response to radiation and the relative biological effect of different radiation types. Track-structure Monte Carlo simulations are an important tool for investigating these responses and for developing mechanistic models to explain them. However, some of the cross-sectional data used in these algorithms has large uncertainties; thus, it is important to investigate how the implementation of the different codes affects the quantities of interest. Methods: Two of the most widely-used publicly available track-structure Monte Carlo codes, Geant4-DNA and NOREC, were used generate electron tracks for two particle sources. One source was a mono-energetic parallel beam of electrons with energies from 5 to 500-keV, and the lineal energy for each track was calculated in 1-mm-spheres arranged in planar arrays at multiple distances from the source. The second source was mono-energetic, uniformly-distributed, and isotropic source, and the lineal energy was scored in a single 30-mm-sphere for energies between 300-eV and 5-keV. Results: The dose-mean lineal energy for the parallel-beam simulations almost all agreed within 5%. For the uniformly-distributed source, at the lowest energies there was strong agreement between the algorithms, but the Geant4-DNA simulations showed slightly more high-energy events for more energetic electrons, but the dose-mean lineal energy agreed to within 4% for all energies. Conclusion: While there were slight differences in the results between the codes, these were consistent with previous studies of the stopping power and angular scattering distributions. Importantly, the computation time for Geant4-DNA was larger than for NOREC, largely due to approximations used in the NOREC for energies below 10-eV. This study shows that these approximation does not have a major impact on the microdosimetry on the energy and length scales investigated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗