Search NASA⌕ Search

SEARCH · Search NASA

Results for “microfluidics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Enhanced Stability and Sensitivity for CA-125 Detection Under Microfluidic Shear Flow Using Polyethylene Glycol-Coated Biosensor

The microfluidic-based point-of-care (POC) diagnostic tool has garnered significant interest in recent years, offering rapid and cost-effective disease detection. There is a growing trend toward integrating microfluidic platforms with biosensors, aligning lab-on-a-chip technologies with POC diagnostic devices. Despite numerous efforts to incorporate biosensors into microfluidic systems, researchers have performed very limited investigations on the stability of biomarker detection when biosensors operate under microfluidic shear flow conditions. Gold nanoparticles (AuNPs) are a widely employed material in capacitive biosensors for antibody immobilization and sensitivity enhancement. However, AuNPs have limitations in providing stable detection of biomarkers within microfluidic shear flow due to their agglomeration nature. This study addresses these limitations by employing 2 kDa polyethylene glycol (PEG) as an intermediate biofunctional layer to immobilize CA-125 antibodies on gold-interdigitated electrodes for the stable and accurate detection of CA-125 antigens. The stabilities and sensitivities of AuNPs and PEG-coated biosensors are evaluated under both static drop and microfluidic shear flow conditions for CA-125 antigen detection. The experimental results demonstrate a capacitive signal response (5660 pF at 10 kHz) 2.2 times higher using the PEG-coated biosensor than the signal (2551 pF at 10 kHz) measured by the AuNP-coated biosensor in the detection of CA-125 antigen–antibody conjugation under static drop conditions, indicating the higher sensitivity of the PEG-coated biosensor. Additionally, the PEG-coated biosensor exhibits better consistency for the CA-125 antigen detection between static drop and microfluidic shear flow conditions (Cp decrease in percentage (ΔCp%↓) = 2.9% at 10 kHz) compared to the electrical signals measured using the AuNP-coated biosensor (ΔCp%↓ = 32.4% at 10 kHz), which suggests that the PEG-coated biosensor demonstrates higher stability for CA-125 antigen detection under microfluidic shear flow conditions. With these significant improvements brought by the PEG-coated biosensor, especially under microfluidic conditions, a substantial hurdle in developing electrical biosensors for POC diagnostic applications has been overcome, expediting further advancements in the field.

36 MATERIALS SCIENCE↗

Microfluidic technology platforms for synthesizing, labeling and measuring the kinetics of transport and biochemical reactions for developing molecular imaging probes

Radiotracer techniques are used in environmental sciences, geology, biology and medicine. Radiotracers with Positron Emission Tomography (PET) provided biological examinations of ~3 million patients 2008. Despite the success of positron labeled tracers in many sciences, there is limited access in an affordable and convenient manner to develop and use new tracers. Integrated microfluidic chips are a new technology well matched to the concentrations of tracers. Our goal is to develop microfluidic chips and new synthesis approaches to enable wide dissemination of diverse types of tracers at low cost, and to produce new generations of radiochemists for which there are many unfilled jobs. The program objectives are to: 1. Develop an integrated microfluidic platform technology for synthesizing and 18F-labeling diverse arrays of different classes of molecules. 2. Incorporate microfluidic chips into small PC controlled devices (“Synthesizer”) with a platform interfaced to PC for electronic and fluid input/out control. 3. Establish a de-centralized model with Synthesizers for discovering and producing molecular imaging probes, only requiring delivery of inexpensive [18F]fluoride ion from commercial PET radiopharmacies vs the centralized approach of cyclotron facilities synthesizing and shipping a few different types of 18F-probes. 4. Develop a position sensitive avalanche photo diode (PSAPD) camera for beta particles embedded in a microfluidic chip for imaging and measuring transport and biochemical reaction rates to valid new 18F-labeled probes in an array of cell cultures. These objectives are met within a research and educational program integrating radio-chemistry, synthetic chemistry, biochemistry, engineering and biology in the Crump Institute for Molecular Imaging. The Radiochemistry Training Program exposes PhD and post doctoral students to molecular imaging in vitro in cells and microorganisms in microfluidic chips and in vivo with PET, from new technologies for radiochemistry (macro to micro levels), biochemistry and biology to imaging principles, tracer kinetics, pharmacokinetics and biochemical assays. New generations of radiochemists will be immersed in the biochemistry and biology for which their labeled probes are being developed for assays of these processes. In this program engineers and radio-chemists integrate the principles of microfluidics and radiolabeling along with proper system design and chemistry rule sets to yield Synthesizers enabling biological and pharmaceutical scientists to develop diverse arrays of probes to pursue their interests. This progression would allow also radiochemists to focus on the further evolution of rapid, high yield synthetic reactions with new enabling technologies, rather than everyday production of radiotracers that should be done by technologists. The invention of integrated circuits in electronics established a platform technology that allowed an evolution of ideas and applications far beyond what could have been imagined at the beginning. Rather than provide a technology for the solution to a single problem, it is hoped that microfluidic radiochemistry will be an enabling platform technology for others to solve many problems. As part of this objective, another program goal is to commercialize the technologies that come from this work so that they can be provided to others who wish to use it.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Cationic lipid/DNA complexes manufactured by microfluidics and bulk self-assembly exhibit different transfection behavior

Highlights: • Transfection efficiency of lipid/DNA complexes manufactured by microfluidics is low. • Lipid/DNA complexes prepared by microfluidics have a minor impact on cell viability. • Optimized microfluidic manufacture will produce effective and not toxic lipoplexes. Recent advances in biochemical and biophysical research have been achieved through the employment of microfluidic devices. Microfluidic mixing of therapeutic agents with biomaterials yields systems with finely tuned physical-chemical properties for applications in drug and gene delivery. Here, we investigate the role of preparation technology (microfluidic mixing vs. bulk self-assembly) on the transfection efficiency (TE) and cytotoxicity of multicomponent cationic liposome/DNA complexes (lipoplexes) in live Chinese hamster ovarian (CHO) cells. Decoupling TE and cytotoxicity allowed us to combine them in a unique coherent vision. While bulk self-assembly produces highly efficient and highly toxic MC lipoplexes, microfluidics manufacture leads to less efficient, but less cytotoxic complexes. This discrepancy is ascribed to two main factors controlling lipid-mediated cell transfection, i.e. the lipoplex concentration at the cell surface and the lipoplex arrangement at the nanoscale. Further research is required to optimize microfluidic manufacturing of lipoplexes to obtain highly efficient and not cytotoxic gene delivery systems.

60 APPLIED LIFE SCIENCES↗

Perspectives on Polyolefin Catalysis in Microfluidics for High-Throughput Screening: A Minireview

Polyolefins are the largest produced plastics in the world which traditionally employ continuous stirred tank reactors and fluidized bed reactors for commercial production. The operating condition, reaction kinetics, and molecular interactions inside the reactor strongly affect the polyolefin properties, which require stringent process control in conventional procedures. Understanding the catalytic pathway, behavior of polymer particles and effect of reactor conditions are essential for designing specific polymer properties, namely the molecular weight, chain length, polydispersity, etc. Microfluidics can play a significant role in designing polymers tailored to the user needs. Smaller channel dimensions help obtain uniform reaction conditions over the length of the microfluidic reactor in a controlled environment. With real-time monitoring techniques in microfluidics, even single particle growth of polymer can be studied to understand the parameters affecting the polymer properties. High throughput microfluidics can help catalyst screening in a short duration with less consumption of reagents generating less waste. When supplemented with efficient machine learning algorithms, automated high throughput microfluidics has the potential to rapidly optimize the process and develop new knowledge even with a limited data set. When trained on data sets generated using microfluidic experiments that are designed efficiently with working knowledge of the process, machine learning algorithms can provide the relationship between the multivariable parameters space and polymer properties, which is not possible with the traditional statistical methods and interpolation techniques. Here, the rise in the utilization of microfluidics, with the advancement of machine learning algorithms, for polyolefin catalysis, highlights the importance of microfluidics for catalyst discovery, parameter optimization, and understanding reaction pathway for producing polymers with specific properties for specialized applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Principles, Techniques, and Applications of Tissue Microfluidics

The principle of tissue microfluidics and its resultant techniques has been applied to cell analysis. Building microfluidics to suit a particular tissue sample would allow the rapid, reliable, inexpensive, highly parallelized, selective extraction of chosen regions of tissue for purposes of further biochemical analysis. Furthermore, the applicability of the techniques ranges beyond the described pathology application. For example, they would also allow the posing and successful answering of new sets of questions in many areas of fundamental research. The proposed integration of microfluidic techniques and tissue slice samples is called "tissue microfluidics" because it molds the microfluidic architectures in accordance with each particular structure of each specific tissue sample. Thus, microfluidics can be built around the tissues, following the tissue structure, or alternatively, the microfluidics can be adapted to the specific geometry of particular tissues. By contrast, the traditional approach is that microfluidic devices are structured in accordance with engineering considerations, while the biological components in applied devices are forced to comply with these engineering presets.

Wade, Lawrence A.↗

Rapid microfluidic thermal cycler for nucleic acid amplification

A system for thermal cycling a material to be thermal cycled including a microfluidic heat exchanger; a porous medium in the microfluidic heat exchanger; a microfluidic thermal cycling chamber containing the material to be thermal cycled, the microfluidic thermal cycling chamber operatively connected to the microfluidic heat exchanger; a working fluid at first temperature; a first system for transmitting the working fluid at first temperature to the microfluidic heat exchanger; a working fluid at a second temperature, a second system for transmitting the working fluid at second temperature to the microfluidic heat exchanger; a pump for flowing the working fluid at the first temperature from the first system to the microfluidic heat exchanger and through the porous medium; and flowing the working fluid at the second temperature from the second system to the heat exchanger and through the porous medium.

42 ENGINEERING↗

Bead-based microfluidic immunoassay for diagnosis of Johne's disease

Microfluidics technology offers a platform for development of point-of-care diagnostic devices for various infectious diseases. In this study, we examined whether serodiagnosis of Johne s disease (JD) can be conducted in a bead-based microfluidic assay system. Magnetic micro-beads were coated with antigens of the causative agent of JD, Mycobacterium avium subsp. paratuberculosis. The antigen-coated beads were incubated with serum samples of JD-positive or negative serum samples and then with a fluorescently-labeled secondary antibody (SAB). To confirm binding of serum antibodies to the antigen, the beads were subjected to flow cytometric analysis. Different conditions (dilutions of serum and SAB, types of SAB, and types of magnetic beads) were optimized for a great degree of differentiation between the JD-negative and JD-positive samples. Using the optimized conditions, we tested a well-classified set of 155 serum samples from JD negative and JD-positive cattle by using the bead-based flow cytometric assay. Of 105 JD-positive samples, 63 samples (60%) showed higher antibody binding levels than a cut-off value determined by using antibody binding levels of JD-negative samples. In contrast, only 43-49 JD-positive samples showed higher antibody binding levels than the cut-off value when the samples were tested by commercially-available immunoassays. Microfluidic assays were performed by magnetically immobilizing a number of beads within a microchannel of a glass microchip and detecting antibody on the collected beads by laser-induced fluorescence. Antigen-coated magnetic beads treated with bovine serum sample and fluorescently-labeled SAB were loaded into a microchannel to measure the fluorescence (reflecting level of antibody binding) on the beads in the microfluidic system. When the results of five bovine serum samples obtained with the system were compared to those obtained with the flow cytometer, a high level of correlation (linear regression, r2 = 0.994) was observed. In a further experiment, we magnetically immobilized antigen-coated beads in a microchannel, reacted the beads with serum and SAB in the channel, and detected antibody binding to the beads in the microfluidic system. A strong antibody binding in JD-positive serum was detected, whereas there was only negligible binding in negative control experiments. Our data suggest that the bead-based microfluidic system may form a basis for development of an on-site serodiagnosis of JD. Key Words: Mycobacterium avium ssp. paratuberculosis, Johne s disease, microfluidics, lab-on-a-chip.

60 APPLIED LIFE SCIENCES↗

High-temperature high-pressure microfluidic system for rapid screening of supercritical CO 2 foaming agents

CO 2 foam helps to increase the viscosity of CO 2 flood fluid and thus improve the process efficiency of the anthropogenic greenhouse gas’s subsurface utilization and sequestration. Successful CO 2 foam formation mandates the development of high-performance chemicals at close to reservoir conditions, which in turn requires extensive laboratory tests and evaluations. This work demonstrates the utilization of a microfluidic reservoir analogue for rapid evaluation and screening of commercial surfactants (i.e., Cocamidopropyl Hydroxysultaine, Lauramidopropyl Betaine, Tallow Amine Ethoxylate, N,N,N' Trimethyl-N'-Tallow-1,3-diaminopropane, and Sodium Alpha Olefin Sulfonate) based on their performance to produce supercritical CO 2 foam at high salinity, temperature, and pressure conditions. The microfluidic analogue was designed to represent the pore sizes of the geologic reservoir rock and to operate at 100 °C and 13.8 MPa. Values of the pressure drop across the microfluidic analogue during flow of the CO 2 foam through its pore network was used to evaluate the strength of the generated foam and utilized only milliliters of liquid. The transparent microfluidic pore network allows in-situ quantitative visualization of CO 2 foam to calculate its half-life under static conditions while observing if there is any damage to the pore network due to precipitation and blockage. The microfluidic mobility reduction results agree with those of foam loop rheometer measurements, however, the microfluidic approach provided more accurate foam stability data to differentiate the foaming agent as compared with conventional balk testing. The results obtained here supports the utility of microfluidic systems for rapid screening of chemicals for carbon sequestration or enhanced oil recovery operations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

In Situ Chemical Monitoring and Imaging of Contents within Microfluidic Devices Having a Porous Membrane Wall Using Liquid Microjunction Surface Sampling Probe Mass Spectrometry

The ability to observe dynamic chemical processes (e.g., signaling, transport, etc.) in vivo or in situ using nondestructive chemical imaging opens a new door to understanding the complex dynamics of developing biological systems. With the advent of “biology-on-a-chip” devices has come the ability to monitor dynamic chemical processes in a controlled environment, using these engineered habitats to capture key features of natural systems while allowing visual observation of system development. Having the capability to spatially and temporally map the chemical signals within these devices may yield new insights into the forces that drive biosystem development. Here, a porous membrane sealed microfluidic device was designed to allow normal microfluidic operation while enabling continuous, location specific sampling and chemical characterization by liquid microjunction surface sampling probe mass spectrometry (LMJ-SSP MS). LMJ-SSP was used to extract fluids with nL-to-μL/min flow rates directly from selected areas of the microfluidic device without negatively impacting the device function. These extracts were subsequently characterized using MS. This technique was used to acquire MS images of the entirety of several multi-input microfluidic devices having different degrees of fluid mixing. LMJ-SSP MS imaging visualized the spatial distribution of chemical components within the microfluidic channels and could visualize chemical reactions occurring in the device. These microfluidic devices with a porous membrane wall are wholly compatible with the construction of biology-on-a-chip devices. This ultimately would enable correlation of biosystem physical structure with an evolving chemical environment

47 OTHER INSTRUMENTATION↗

Continuous Counter‐Current Microfluidic Liquid–Liquid Extraction Achieved Using a Pair of Wettable Screen Meshes

Continuous counter‐current microfluidic liquid–liquid extraction performs separations by flowing immiscible liquids in opposing directions within a single flow channel. In principle, this flow arrangement enables a large number of theoretical separation units in a small footprint, without using interstage valving, pumping, and phase separation. Despite its potential for excellent separation performance, this microfluidic scheme rarely appears in literature due to the requirement for capillary forces to be greater than hydrodynamic forces for stable flow. We present a novel microfluidic device and flow approaches that overcome this force‐balance challenge, enabling stable, long‐duration continuous counter‐current flow. Additionally, we cover a suite of methodologies for quantifying the performance of the microfluidic device, revealing the number of theoretical equilibrium stages achieved. The enabling technologies include a woven mesh screen‐based microfluidic device architecture that is easily fabricated outside of a clean room, surface functionalization strategies to promote conjugate (organic/aqueous) wettability, flow approaches to eliminate bubbles and carryover, and computer‐aided flow automation with optical measurement of extraction performance. The reported experiments lasted for over 36 h, terminated only at experiment conclusion, where the device still exhibited good performance. Automated Raman spectroscopy was used for solute quantitation of the ternary system tert‐butanol in a toluene/water matrix, a ternary system that was specifically chosen to analyze the device's performance with a small solute partition ratio and to enable in‐line Raman measurements of solute concentrations in both phases. The microfluidic device possessed a 55 mm contact length and a 38.5 µL internal volume. During counter‐current flow, we observed approximately 37 equilibrium stages (37 ± 13) based on a best‐fit of the solute fraction remaining in the aqueous phase using a Kremser Group Method analysis.

36 MATERIALS SCIENCE↗

Aerosol jet printing of surface acoustic wave microfluidic devices

Abstract The addition of surface acoustic wave (SAW) technologies to microfluidics has greatly advanced lab-on-a-chip applications due to their unique and powerful attributes, including high-precision manipulation, versatility, integrability, biocompatibility, contactless nature, and rapid actuation. However, the development of SAW microfluidic devices is limited by complex and time-consuming micro/nanofabrication techniques and access to cleanroom facilities for multistep photolithography and vacuum-based processing. To simplify the fabrication of SAW microfluidic devices with customizable dimensions and functions, we utilized the additive manufacturing technique of aerosol jet printing. We successfully fabricated customized SAW microfluidic devices of varying materials, including silver nanowires, graphene, and poly(3,4-ethylenedioxythiophene) polystyrene sulfonate (PEDOT:PSS). To characterize and compare the acoustic actuation performance of these aerosol jet printed SAW microfluidic devices with their cleanroom-fabricated counterparts, the wave displacements and resonant frequencies of the different fabricated devices were directly measured through scanning laser Doppler vibrometry. Finally, to exhibit the capability of the aerosol jet printed devices for lab-on-a-chip applications, we successfully conducted acoustic streaming and particle concentration experiments. Overall, we demonstrated a novel solution-based, direct-write, single-step, cleanroom-free additive manufacturing technique to rapidly develop SAW microfluidic devices that shows viability for applications in the fields of biology, chemistry, engineering, and medicine.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Microfluidic electrochemical reactors

A microfluidic electrochemical reactor includes an electrode and one or more microfluidic channels on the electrode, where the microfluidic channels are covered with a membrane containing a gas permeable polymer. The distance between the electrode and the membrane is less than 500 micrometers. The microfluidic electrochemical reactor can provide for increased reaction rates in electrochemical reactions using a gaseous reactant, as compared to conventional electrochemical cells. Microfluidic electrochemical reactors can be incorporated into devices for applications such as fuel cells, electrochemical analysis, microfluidic actuation, pH gradient formation.

42 ENGINEERING↗

Passive microfluidic array card and reader

A microfluidic array card and reader system for analyzing a sample. The microfluidic array card includes a sample loading section for loading the sample onto the microfluidic array card, a multiplicity of array windows, and a transport section or sections for transporting the sample from the sample loading section to the array windows. The microfluidic array card reader includes a housing, a receiving section for receiving the microfluidic array card, a viewing section, and a light source that directs light to the array window of the microfluidic array card and to the viewing section.

47 OTHER INSTRUMENTATION↗

Microfluidic Cell-based Assays in Stem Cell and Other Rare Cell Type Research

Microfluidics is a technology defined by the engineered precise manipulation of minute amount of liquids through channels with dimensions in the micron scale. Much of microfluidic devices used for biomedical purposes are produced in the form of so called “lab-on-a-chip” format, where multiple steps of conventional biochemical analyses such as staining, washing, and signal collection are miniaturized and integrated into chips fabricated from polymer or glass. Cell-based microfluidic lab-on-achip technology provides some obvious advantages: 1) drastically reduced sample and reagent requirement, and 2) separation and detection with improved sensitivity due to fluid properties at the microscale, i.e. laminar flow. Based on these two advantages, the obvious place where microfluidic cell assays will provide the most benefit is wherescientists must gather much information from precious little sample. Stem cells and other precious cell types such as circulating tumor cells (CTCs), and rare immune subsets are the perfect match for microfluidic multiplex assays. The recent demonstration that multiple cellular changes such as surface receptor activation, protein translocation, long and short RNA, and DNA changes can all be extracted from intact single cells paves the way to systems level understanding of cellular states during development or disease. Finally, with the ability to preserve cell integrity in a microfluidic device during multiplexed analysis, one also preserves the single cell resolution, where information regarding the cell-to-cell heterogeneity during differentiation or response to stimuli is vitally important.

59 BASIC BIOLOGICAL SCIENCES↗

Automated control of microfluidic devices based on machine learning

A system is provided to automatically monitor and control the operation of a microfluidic device using machine learning technology. The system receives images of a channel of a microfluidic device collected by a camera during operation of the microfluidic device. Upon receiving an image, the system applies a classifier to the image to classify the operation of the microfluidic device as normal, in which no adjustment to the operation is needed, or as abnormal, in which an adjustment to the operation is needed. When an image is classified as normal, the system may make no adjustment to the microfluidic device. If, however, an image is classified as abnormal, the system may output an indication that the operation is abnormal, output an indication of a needed adjustment, or control the microfluidic device to make the needed adjustment.

42 ENGINEERING↗

Automated control of microfluidic devices based on machine learning

A system is provided to automatically monitor and control the operation of a microfluidic device using machine learning technology. The system receives images of a channel of a microfluidic device collected by a camera during operation of the microfluidic device. Upon receiving an image, the system applies a classifier to the image to classify the operation of the microfluidic device as normal, in which no adjustment to the operation is needed, or as abnormal, in which an adjustment to the operation is needed. When an image is classified as normal, the system may make no adjustment to the microfluidic device. If, however, an image is classified as abnormal, the system may output an indication that the operation is abnormal, output an indication of a needed adjustment, or control the microfluidic device to make the needed adjustment.

Giera, Brian↗

Controlling matric potential in microfluidics to examine microbial dynamics in unsaturated porous media

The use of microfluidics for the study of soil microbial ecology is an emerging field. Most microfluidic studies of biological systems, however, have been performed under fully saturated conditions that are not representative of natural soil. Therefore, while microfluidics offer many unique capabilities that other methodologies cannot, they are not currently suited to address the effects of matric potential, an important variable defining the microbial moisture niche. Here, a methodology is presented that allows the user to control the aqueous conditions within microfluidic networks by manipulating matric potential using a hanging water column. The method relies on hydrophilic surface treatment of the microfluidic device using polyvinyl alcohol (PVA) and incorporating a bed of small pores at the network boundaries, which serve as a porous ceramic plate analogue (PPA). The method was validated on a simple capillary bundle and then on a more complex pore network. A water retention curve, exhibiting hysteresis, was generated for the pore network over a narrow matric potential range of 0 to – 5 kPa. Both the drainage and wetting curves were reproducible, as were the spatial configuration and the number of fragmented moisture niches in the pore network, particularly on the drainage curve. In contrast, the wetting curve exhibited greater variability in spatial configuration due to the “ink bottle effect,” where capillarity was interrupted by wider pore bodies. Ultimately, the methodology provides realistic pore-scale moisture conditions that can be easily manipulated and maintained, enabling new opportunities to explore soil biophysics and microbial biogeography in unsaturated porous media. As a brief example, images showing the localization of fluorescently tagged Pantoea sp. YR343 at −4.3 kPa are presented, highlighting bacterial distributions in water films and air-water interfaces.

59 BASIC BIOLOGICAL SCIENCES↗

In situ molecular imaging of hydrated biofilm in a microfluidic reactor by ToF-SIMS

The first results of using a novel single channel microfluidic reactor to enable Shewanella biofilm growth and in situ characterization using time-of-flight secondary ion mass spectrometry (ToF-SIMS) in the hydrated environment are presented. The new microfluidic interface allows direct probing of the liquid surface using ToF-SIMS, a vacuum surface technique. The detection window is an aperture of 2 m in diameter on a thin silicon nitride (SiN) membrane and it allows direct detection of the liquid surface. Surface tension of the liquid flowing inside the microchannel holds the liquid within the aperture. ToF-SIMS depth profiling was used to drill through the SiN membrane and the biofilm grown on the substrate. In situ 2D imaging of the biofilm in hydrated state was acquired, providing spatial distribution of the chemical compounds in the biofilm system. This data was compared with a medium filled microfluidic reactor devoid of biofilm and dried biofilm samples deposited on clean silicon wafers. Principle Component Analysis (PCA) was used to investigate these observations. Our results show that imaging biofilms in the hydrated environment using ToF-SIMS is possible using the unique microfluidic reactor. Moreover, characteristic biofilm fatty acids fragments were observed in the hydrated biofilm grown in the microfluidic channel, illustrating the advantage of imaging biofilm in its native environment.

Environmental Molecular Sciences Laboratory↗