Search NASA⌕ Search

SEARCH · Search NASA

Results for “microscopic analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

MISSE 6, 7 and 8 Materials Sample Experiments from the International Space Station Materials and Processes Team

The International Space Station Materials and Processes (ISS M&P) team has multiple material samples on MISSE 6, 7 and 8 to observe Low Earth Orbit (LEO) environmental effects on Space Station materials. Optical properties, thickness/mass loss, surface elemental analysis, visual and microscopic analysis for surface change are some of the techniques employed in this investigation. The ISS M&P team has participated in previous MISSE activities in order to better characterize the LEO effects on Space Station materials. This investigation will further this effort. Results for the following MISSE 6 samples materials will be presented: a comparison of anodize and chemical conversion coatings on various aluminum alloys, electroless nickel; AZ93 white ceramic thermal control coating with and without Teflon; Hyzod(TM) polycarbonate used to temporarily protect ISS windows; Russian quartz window material; reformulated Teflon (TM) coated Beta Cloth (Teflon TM without perfluorooctanoic acid (PFOA)) and a Dutch version of beta cloth. Discussion for current and future MISSE materials experiments will be presented. MISSE 7 samples are: deionized water sealed anodized aluminum Photofoil(TM); indium tin oxide (ITO)- coated Kapton(TM) used as thermo-optical surfaces; mechanically scribed tin-plated beryllium-copper samples for "tin pest" growth ( alpha/Beta transformation); Crew Exploration Vehicle (CEV) parachute soft goods. MISSE 8 sample: exposed "scrim cloth" (fiberglass weave) from the ISS solar array wing material, Davlyn fiberglass sleeve material, Permacel and Intertape protective tapes, and ITO-coated Kapton.

Kravchenko, Michael↗

Analysis of International Space Station Vehicle Materials on MISSE 6

The International Space Station Materials and Processes team has multiple material samples on MISSE 6, 7 and 8 to observe Low Earth Orbit (LEO) environmental effects on Space Station materials. Optical properties, thickness/mass loss, surface elemental analysis, visual and microscopic analysis for surface change are some of the techniques employed in this investigation. Results for the following MISSE 6 samples materials will be presented: deionized water sealed anodized aluminum; Hyzod(tm) polycarbonate used to temporarily protect ISS windows; Russian quartz window material; Beta Cloth with Teflon(tm) reformulated without perfluorooctanoic acid (PFOA), and electroless nickel. Discussion for current and future MISSE materials experiments will be presented. MISSE 7 samples are: more deionized water sealed anodized aluminum, including Photofoil(tm); indium tin oxide (ITO) over-coated Kapton(tm) used as thermo-optical surfaces; mechanically scribed tin-plated beryllium-copper samples for "tin pest" growth (alpha/beta transformation); and beta cloth backed with a black coating rather than aluminization. MISSE 8 samples are: exposed "scrim cloth" (fiberglass weave) from the ISS solar array wing material, protective fiberglass tapes and sleeve materials, and optical witness samples to monitor contamination.

Finckenor, Miria↗

Results of International Space Station Vehicle Materials Exposed on MISSE-7B

Materials samples were exposed to the low Earth orbit (LEO) environment as part of the MISSE-7B flight experiment for 18 months. Optical properties, thickness/mass loss, surface elemental analysis, visual and microscopic analysis for surface change are some of the techniques employed in this investigation. Where possible, the MISSE-7B results are compared to analyses from other LEO experiments. ISS materials currently flying on MISSE-8 are also discussed.

Finckenor, Miria M.↗

Further Analysis of Materials Exposed on MISSE-6 and-7B

Materials samples were exposed to the low Earth orbit (LEO) environment as part of the MISSE- 6 and -7B flight experiments. Optical properties, thickness/mass loss, surface elemental analysis, visual and microscopic analysis for surface change are some of the techniques employed in this investigation. Effects of molecular contamination are discussed. Where possible, the MISSE-6 and -7B results are compared to analyses from other LEO experiments.

Finckenor, Miria↗

Three-dimensional stacking of canted antiferromagnetism and pseudospin current in undoped Sr 2 IrO 4 : Symmetry analysis and microscopic model realization

Recent optical second-harmonic generation experiments observed unexpected broken spatial symmetries in the undoped spin-orbit Mott insulator Sr2 IrO4, leading to intensive debates on the nature of its ground state. Here we propose that it is a canted antiferromagnetism (CAF) with a hidden order of circulating staggered pseudospin current. Symmetry analysis shows that a proper c-axis stacking of the CAF and the pseudospin current lead to a magnetoelectric coexistence state that breaks the twofold rotation, inversion, and time-reversal symmetries, consistent with experimental observations. We construct a three-dimensional Hubbard model with spin-orbit coupling and structural distortion for the five localized 5d Wannier orbitals centered at Ir sites and demonstrate the microscopic realization of the desired coexistence state in a wide range of band parameters via a combination of self-consistent Hartree-Fock and variational calculations.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Microscopic theory, analysis, and interpretation of conductance histograms in molecular junctions

Molecular electronics break-junction experiments are widely used to investigate fundamental physics and chemistry at the nanoscale. Reproducibility in these experiments relies on measuring conductance on thousands of freshly formed molecular junctions, yielding a broad histogram of conductance events. Experiments typically focus on the most probable conductance, while the information content of the conductance histogram has remained unclear. Here we develop a microscopic theory for the conductance histogram by merging the theory of force-spectroscopy with molecular conductance. The procedure yields analytical equations that accurately fit the conductance histogram of a wide range of molecular junctions and augments the information content that can be extracted from them. Our formulation captures contributions to the conductance dispersion due to conductance changes during the mechanical elongation inherent to the experiments. In turn, the histogram shape is determined by the non-equilibrium stochastic features of junction rupture and formation. The microscopic parameters in the theory capture the junction’s electromechanical properties and can be isolated from separate conductance and rupture force (or junction-lifetime) measurements. The predicted behavior can be used to test the range of validity of the theory, understand the conductance histograms, design molecular junction experiments with enhanced resolution and molecular devices with more reproducible conductance properties.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Heat Transfer and Thermal Stability Research for Advanced Hydrocarbon Fuel Technologies

In recent years there has been increased interest in the development of a new generation of high performance boost rocket engines. These efforts, which will represent a substantial advancement in boost engine technology over that developed for the Space Shuttle Main Engines in the early 1970s, are being pursued both at NASA and the United States Air Force. NASA, under its Space Launch Initiative s Next Generation Launch Technology Program, is investigating the feasibility of developing a highly reliable, long-life, liquid oxygen/kerosene (RP-1) rocket engine for launch vehicles. One of the top technical risks to any engine program employing hydrocarbon fuels is the potential for fuel thermal stability and material compatibility problems to occur under the high-pressure, high-temperature conditions required for regenerative fuel cooling of the engine combustion chamber and nozzle. Decreased heat transfer due to carbon deposits forming on wetted fuel components, corrosion of materials common in engine construction (copper based alloys), and corrosion induced pressure drop increases have all been observed in laboratory tests simulating rocket engine cooling channels. To mitigate these risks, the knowledge of how these fuels behave in high temperature environments must be obtained. Currently, due to the complexity of the physical and chemical process occurring, the only way to accomplish this is empirically. Heated tube testing is a well-established method of experimentally determining the thermal stability and heat transfer characteristics of hydrocarbon fuels. The popularity of this method stems from the low cost incurred in testing when compared to hot fire engine tests, the ability to have greater control over experimental conditions, and the accessibility of the test section, facilitating easy instrumentation. These benefits make heated tube testing the best alternative to hot fire engine testing for thermal stability and heat transfer research. This investigation used the Heated Tube Facility at the NASA Glenn Research Center to perform a thermal stability and heat transfer characterization of RP-1 in an environment simulating that of a high chamber pressure, regenerative cooled rocket engine. The first step in the research was to investigate the carbon deposition process of previous heated tube experiments by performing scanning electron microscopic analysis in conjunction with energy dispersive spectroscopy on the tube sections. This analysis gave insight into the carbon deposition process and the effect that test conditions played in the formation of deleterious coke. Furthermore, several different formations were observed and noted. One other crucial finding of this investigation was that in sulfur containing hydrocarbon fuels, the interaction of the sulfur components with copper based wall materials presented a significant corrosion problem. This problem in many cases was more life limiting than those posed by the carbon deposition process. The results of this microscopic analysis was detailed and presented at the December 2003 JANNAF Air-Breathing Propulsion Meeting as a Materials Compatibility and Thermal Stability Analysis of common Hydrocarbon Fuels (reference 1).

DeWitt, Kenneth↗

Design of a Thermal Precipitator for the Characterization of Smoke Particles from Common Spacecraft Materials

A thermal precipitator (TP) was designed to collect smoke aerosol particles for microscopic analysis in fire characterization research. Information on particle morphology, size and agglomerate structure obtained from these tests supplements additional aerosol data collected. Modeling of the thermal precipitator throughout the design process was performed with the COMSOL Multiphysics finite element software package, including the Eulerian flow field and thermal gradients in the fluid. The COMSOL Particle Tracing Module was subsequently used to determine particle deposition. Modeling provided optimized design parameters such as geometry, flow rate and temperatures. The thermal precipitator was built and testing verified the performance of the first iteration of the device. The thermal precipitator was successfully operated and provided quality particle samples for microscopic analysis, which furthered the body of knowledge on smoke particulates. This information is a key element of smoke characterization and will be useful for future spacecraft fire detection research.

Smoke↗

Electrode erosion in steady-state electric propulsion engines

The anode and cathode of a 30 kW class arcjet engine were sectioned and analyzed. This arcjet was operated for a total time of 573 hr at power levels between 25 and 30 kW with ammonia at flow rates of 0.25 and 0.27 gm/s. The accumulated run time was sufficient to clearly establish erosion patterns and their causes. The type of electron emission from various parts of the cathode surface was made clear by scanning electron microscope analysis. A scanning electron microscope was used to study recrystallization on the hot anode surface. These electrodes were made of 2 percent thoriated tungsten and the surface thorium content and gradient perpendicular to the surfaces was determined by quantitative microprobe analysis. The results of this material analysis on the electrodes and recommendations for improving electrode operational life time are presented.

Pivirotto, Thomas J.↗

Finite element microscopic stress analysis of cracked composite systems

This paper considers the stress concentration problems of two types of cracked composite systems: (1) a composite system with a broken fiber (a penny-shaped crack problem), and (2) a composite system with a cracked matrix (an annular crack problem). The cracked composite systems are modeled with triangular and trapezoidal ring finite elements. Using NASTRAN (NASA Structural Analysis) finite element computer program, the stress and deformation fields in the cracked composite systems are calculated. The effect of fiber-matrix material combination on the stress concentrations and on the crack opening displacements is studied.

Ko, W. L.↗

Time-dependent thermal degradation of lost circulation materials in geothermal systems

Treatment of lost circulation can represent anywhere from 5 to 25 % of the cost in drilling geothermal wells. The cost of the materials used for lost circulation treatment is less important than their effectiveness at reducing fluid losses. In geothermal systems, the high temperatures (>90 °C) are expected to degrade many commonly used lost circulation materials over time. This degradation could compromise different materials ability to mitigate fluid loss, creating more non-productive time as multiple treatments are needed, but may result in recovering desired permeability zones within the reservoir section over time. This research aimed to study how thermal degradation of eight different lost circulation materials affected their properties relevant to sealing loss zones in geothermal wells. Here, mass loss experiments were conducted with each material at temperatures of 90–250 °C for 1–42 days to measure the breakdown of the material at geothermal conditions, collecting gases during several experiments to determine the waste produced during degradation. Compaction experiments were conducted with the degraded materials to show how temperatures reduced the rigidity and increased packing of the materials. Viscosity tests were conducted to show the impact of different materials on drilling fluid rheology. Microscope observations were conducted to characterize the alterations to each material due to thermal degradation. Organic materials tend to degrade more than inorganic materials, with organics like microcellulose, cotton seed hulls and sawdust losing 30–50 % of their mass after 1 day of heating at 200 °C, while inorganics like magma fiber only lose ~5–10 % of its mass after one day of heating at 200 °C. Granular materials are the strongest when compacted despite any mass loss, while fibrous and flaky materials are fairly weak and breakdown easily under stress. The materials do not generally affect fluid rheology unless they have a viscosifying agent as part of the mixture. Microscopic analysis showed that more rigid materials like microcellulose and cedar fiber degrade in brittle manners with splitting and fracturing, while others like cotton seed hulls degrade in more ductile manners forming meshes or clumps of material. The thermal breakdown of lost circulation materials tested suggests that each material should also be classified by its degree of thermal degradability, as at certain temperatures the materials can lose the capability to bridge loss zones around the wellbore.

15 GEOTHERMAL ENERGY↗

Analysis of a used pair of arcjet electrodes

The anode and cathode of a 30-kW class arcjet engine have been sectioned and analyzed. This arcjet was operated for a total time of 573 hours at power levels between 25 and 30 kW with ammonia at flow rates of 0.25 and 0.27 gm/s. The accumulated run time was sufficient to clearly establish erosion patterns and their causes. The type of electron emission from various parts of the cathode surface was made clear by Scanning Electron Microscope analysis. A Scanning Electron Microscope was used to study recrystallization on the hot anode surface. These electrodes were made of 2 percent thoriated tungsten and the surface thorium content and gradient perpendicular to the surfaces was determined by quantitative microprobe analysis. The results of this material analysis on the electrodes and recommendations for improving electrode operational life time are presented.

Pivirotto, Thomas J.↗

Compact Microscope Imaging System With Intelligent Controls Improved

The Compact Microscope Imaging System (CMIS) with intelligent controls is a diagnostic microscope analysis tool with intelligent controls for use in space, industrial, medical, and security applications. This compact miniature microscope, which can perform tasks usually reserved for conventional microscopes, has unique advantages in the fields of microscopy, biomedical research, inline process inspection, and space science. Its unique approach integrates a machine vision technique with an instrumentation and control technique that provides intelligence via the use of adaptive neural networks. The CMIS system was developed at the NASA Glenn Research Center specifically for interface detection used for colloid hard spheres experiments; biological cell detection for patch clamping, cell movement, and tracking; and detection of anode and cathode defects for laboratory samples using microscope technology.

McDowell, Mark↗

Methods for the mineralogical and textural analysis of comet nucleus samples

The objectives and instrumental requirements of a petrographic analysis of porous comet nucleus material are reviewed. Assumptions about its composition and texture, and the available techniques for the microscopic analysis of comet analogue material are investigated. New techniques required for the petrographic investigation of natural and artificial comet nucleus samples are also considered.

Stoeffler, D.↗

Micromachined Dust Traps

Micromachined traps devised to capture dust particles for analysis without contaminating them. Based on micromachined structures retaining particles, rather than adhesives or greases interfering with scanning-electron-microscope analysis or x-ray imaging. Unlike maze traps and traps enmeshing particles in steel wool or similar materials, micromachined traps do not obscure trapped particles. Internal geometries of traps range from simple cones to U-shapes, all formed by etching silicon.

Bearman, Gregory H.↗

Hidden Allies: Decoding the Core Endohyphal Bacteriome of Aspergillus fumigatus

ABSTRACT Bacterial–fungal interactions that influence the behaviour of one or both organisms are common in nature. Well‐studied systems include endosymbiotic relationships that range from transient to long‐term associations. Diverse endohyphal bacteria associate with fungal hosts, emphasising the need to better comprehend the fungal bacteriome. We evaluated the hypothesis thatAspergillus fumigatusharbours an endohyphal community of bacteria that influence the host phenotype. We analysed whether 38A. fumigatusstrains show stable association with diverse endohyphal bacteria; all derived from single‐conidium cultures that were subjected to antibiotic and heat treatments. The fungal bacteriome, inferred through analysis of bacterial diversity within the fungal strains (short‐ and long‐ read sequencing methods), revealed the presence of core endohyphal bacterial genera. Microscopic analysis further confirmed the presence of endohyphal bacteria. The fungal strains exhibited high genetic diversity and phenotypic heterogeneity in drug susceptibility and in vivo virulence. No correlations were observed between genomic or functional traits and bacteriome diversity, but the abundance of some bacterial genera correlated with fungal virulence or posaconazole susceptibility. The observed endobacteriome may play functional roles, for example, nitrogen fixation. Our study emphasises the existence of complex interactions between fungi and endohyphal bacteria, possibly impacting the phenotype of the fungal host, including virulence.

Environmental Sciences & Ecology↗