Search NASA⌕ Search

SEARCH · Search NASA

Results for “microsensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Development of a Multi-Gas Microsensor Array for the Exploration Portable Life Support System

The Portable Life Support System (PLSS) of the Exploration Extravehicular Mobility Unit (xEMU) requires sensors capable of measuring the major constituents of the gas stream. These major constituents include oxygen, carbon dioxide, and water vapor. The sensors must operate across a wide range of flow and pressure conditions and introduce very low pressure drop in the ventilation loop. The sensors must operate with low power and occupy a small volume. This paper reports the development of a compact, low power, multi-parameter astronaut life support sensor (M-PALSS). M-PALSS consists of an array of low-power chemical microsensors for oxygen, carbon dioxide, water vapor, and pressure. M-PALSS includes custom electronics to control the sensors and is packaged in a custom housing that meets the volume and shape requirements for service in the PLSS.

James Makel↗

Development of a Multi-Gas Microsensor Array for the Exploration Portable Life Support System

The Portable Life Support System (PLSS) of the Exploration Extravehicular Mobility Unit (xEMU) requires sensors capable of measuring the major constituents of the gas stream. These major constituents include oxygen, carbon dioxide, and water vapor. The sensors must operate across a wide range of flow and pressure conditions and introduce very low pressure drop in the ventilation loop. The sensors must operate with low power and occupy a small volume. This paper reports the development of a compact, low power, multi-parameter astronaut life support sensor (M-PALSS). M-PALSS consists of an array of low-power chemical microsensors for oxygen, carbon dioxide, water vapor, and pressure. M-PALSS includes custom electronics to control the sensors and is packaged in a custom housing that meets the volume and shape requirements for service in the PLSS.

James Makel↗

Development of a Multi-Gas Microsensor Array for the Exploration Portable Life Support System

The Portable Life Support System (PLSS) of the Exploration Extravehicular Mobility Unit (xEMU) requires sensors capable of measuring the major constituents of the gas stream. These major constituents include oxygen, carbon dioxide, and water vapor. The sensors must operate across a wide range of flow and pressure conditions and introduce very low pressure drop in the ventilation loop. The sensors must operate with low power and occupy a small volume. This paper reports the development of a compact, low power, multi-parameter astronaut life support sensor (M-PALSS). M-PALSS consists of an array of low-power chemical microsensors for oxygen, carbon dioxide, water vapor, and pressure. M-PALSS includes custom electronics to control the sensors and is packaged in a custom housing that meets the volume and shape requirements for service in the PLSS.

James Makel↗

Heat flux microsensor measurements and calibrations

A new thin-film heat flux gage has been fabricated specifically for severe high temperature operation using platinum and platinum-10 percent rhodium for the thermocouple elements. Radiation calibrations of this gage were performed at the AEDC facility over the available heat flux range (approx. 1.0 - 1,000 W/cu cm). The gage output was linear with heat flux with a slight increase in sensitivity with increasing surface temperature. Survivability of gages was demonstrated in quench tests from 500 C into liquid nitrogen. Successful operation of gages to surface temperatures of 750 C has been achieved. No additional cooling of the gages is required because the gages are always at the same temperature as the substrate material. A video of oxyacetylene flame tests with real-time heat flux and temperature output is available.

Terrell, James P.↗

Advances in microsensor development for gas and flow measurement in space power and propulsion systems

Emerging microelectromechanical sculpturing technology is presently extended, in conjunction with the use of deep semiconductor impurities having extreme flow sensitivities, small masses for shortest time response, and unconventional electrode schemes for elevated-temperature operation, for rocket-engine fuel flow sensing tasks. The radiation component of heat transfer is negligible, so that the device operates on the basis of conduction and convection loss.

Henderson, H. T.↗

Microsensor Hot-Film Anemometer

Improved hot-film anemometer developed for making high-bandwidth turbulence measurements in moderate-enthalpy supersonic and hypersonic flows (e.g., NASP inlets and control surfaces, HSCT jet exhaust). Features include low thermal inertia, ruggedness, and reduced perturbation of flow.

Mcginley, Catherine B.↗

Microsensors and Microinstruments for Space Science and Exploration

Most future NASA spacecraft will be small, low cost, highly integrated vehicles using advanced technology. This will also be true of planetary rovers. In order to maintain a high scientific value to these missions, the instruments, sensors and subsystems must be dramatically miniaturized without compromising their measurement capabilities. A rover must be designed to deliver its science package. In fact, the rover should be considered as the arms, legs and/or wheels that are needed to enable a mobile integrated scientific payload.

Kukkonen, C. A.↗

Wireless Subsurface Microsensors for Health Monitoring of Thermal Protection Systems on Hypersonic Vehicles

Health diagnostics is an area where major improvements have been identified for potential implementation into the design of new reusable launch vehicles in order to reduce life cycle costs, to increase safety margins, and to improve mission reliability. NASA Ames is leading the effort to develop inspection and health management technologies for thermal protection systems. This paper summarizes a joint project between NASA Ames and SRI International to develop 'SensorTags,' radio frequency identification devices coupled with event-recording sensors, that can be embedded in the thermal protection system to monitor temperature or other quantities of interest. Two prototype SensorTag designs containing thermal fuses to indicate a temperature overlimit are presented and discussed.

Milos, Frank S.↗

Advanced Opto-Electronics (LIDAR and Microsensor Development)

Our overall intent in this aspect of the project were to establish a collaborative effort between several departments at Montana State University for developing advanced optoelectronic technology for advancing the state-of-the-art in optical remote sensing of the environment. Our particular focus was on development of small systems that can eventually be used in a wide variety of applications that might include ground-, air-, and space deployments, possibly in sensor networks. Specific objectives were to: 1) Build a field-deployable direct-detection lidar system for use in measurements of clouds, aerosols, fish, and vegetation; 2) Develop a breadboard prototype water vapor differential absorption lidar (DIAL) system based on highly stable, tunable diode laser technology developed previously at MSU. We accomplished both primary objectives of this project, in developing a field-deployable direct-detection lidar and a breadboard prototype of a water vapor DIAL system. Paper summarizes each of these accomplishments.

Vanderbilt, Vern C.↗

Heat flux instrumentation for Hyflite thermal protection system

Using Thermal Protection Tile core samples supplied by NASA, the surface characteristics of the FRCI, TUFI, and RCG coatings were evaluated. Based on these results, appropriate methods of surface preparation were determined and tested for the required sputtering processes. Sample sensors were fabricated on the RCG coating and adhesion was acceptable. Based on these encouraging results, complete Heat Flux Microsensors were fabricated on the RCG coating. The issue of lead attachment was addressed with the annnealing and welding methods developed at NASA Lewis. Parallel gap welding appears to be the best method of lead attachment with prior heat treatment of the sputtered pads. Sample Heat Flux Microsensors were submitted for testing in the NASA Ames arc jet facility. Details of the project are contained in two attached reports. One additional item of interest is contained in the attached AIAA paper, which gives details of the transient response of a Heat Flux Microsensors in a shock tube facility at Virginia Tech. The response of the heat flux sensor was measured to be faster than 10 micro-s.

Diller, T. E.↗

Measurement of a surface heat flux and temperature

The Heat Flux Microsensor is a new sensor which was recently patented by Virginia Tech and is just starting to be marketed by Vatell Corp. The sensor is made using the thin-film microfabrication techniques directly on the material that is to be measured. It consists of several thin-film layers forming a differential thermopile across a thermal resistance layer. The measured heat flux q is proportional to the temperature difference across the resistance layer q= k(sub g)/delta(sub g) x (t(sub 1) - T(sub 2)), where k(sub g) is the thermal conductivity and delta (sub g) is the thickness of the thermal resistance layer. Because the gages are sputter coated directly onto the surface, their total thickness is less than 2 micrometers, which is two orders of magnitude thinner than previous gages. The resulting temperature difference across the thermal resistance layer (delta is less than 1 micrometer) is very small even at high heat fluxes. To generate a measurable signal many thermocouple pairs are put in series to form a differential thermopile. The combination of series thermocouple junctions and thin-film design creates a gage with very attractive characteristics. It is not only physically non-intrusive to the flow, but also causes minimal disruption of the surface temperature. Because it is so thin, the response time is less than 20 microsec. Consequently, the frequency response is flat from 0 to over 50 kHz. Moreover, the signal of the Heat Flux Microsensor is directly proportional to the heat flux. Therefore, it can easily be used in both steady and transient flows, and it measures both the steady and unsteady components of the surface heat flux. A version of the Heat Flux Microsensor has been developed to meet the harsh demands of combustion environments. These gages use platinum and platinum-10 percent rhodium as the thermoelectric materials. The thermal resistance layer is silicon monoxide and a protective coating of Al2O3 is deposited on top of the sensor. The superimposed thin-film pattern of all six layers is presented. The large pads are for connection with pins used to bring the signal out the back of the ceramic. In addition to the heat flux measurement, the surface temperature is measured with a platinum resistance layer (RTS). The resistance of this layer increases with increasing temperature. Therefore, these gages simultaneously measure the surface temperature and heat flux. The demonstrated applications include rocket nozzles, SCRAM jet engines, gas turbine engines, boiling heat transfer, flame experiments, basic fluid heat transfer, hypersonic flight, and shock tube testing. The laboratory involves using one of these sensors in a small combustion flame. The sensor is made on a 2.5 cm diameter piece of aluminum nitride ceramic.

Davis, R. M.↗

Health Monitoring Technology for Thermal Protection Systems on Reusable Hypersonic Vehicles

Integrated subsystem health diagnostics is an area where major improvements have been identified for potential implementation into the design of new reusable launch vehicles (RLVs) in order to reduce life cycle costs, to increase safety margins, and to improve mission reliability. This talk summarizes a joint effort between NASA Ames and industry partners to develop rapid non-contact diagnostic tools for health and performance monitoring of thermal protection systems (TPS) on future RLVs. The specific goals for TPS health monitoring are to increase the speed and reliability of TPS inspections for improved operability at lower cost. The technology being developed includes a 3-D laser scanner for examining the exterior surface of the TPS, and a subsurface microsensor suite for monitoring the health and performance of the TPS. The sensor suite consists of passive overlimit sensors and sensors for continuous parameter monitoring in flight. The sensors are integrated with radio-frequency identification (RFID) microchips to enable wireless communication of-the sensor data to an external reader that may be a hand-held scanner or a large portal. Prototypes of the laser system and both types of subsurface sensors have been developed. The laser scanner was tested on Shuttle Orbiter Columbia and was able to dimension surface chips and holes on a variety of TPS materials. The temperature-overlimit microsensor has a diameter under 0.05 inch (suitable for placement in gaps between ceramic TPS tiles) and can withstand 700 F for 15 minutes.

Milos, Frank S.↗

Heat Flux Sensor

A heat flux microsensor developed under a NASP Small Business Innovation Research (SBIR) has a wide range of potential commercial applications. Vatell Corporation originally designed microsensors for use in very high temperatures. The company then used the technology to develop heat flux sensors to measure the rate of heat energy flowing in and out of a surface as well as readings on the surface temperature. Additional major advantages include response to heat flux in less than 10 microseconds and the ability to withstand temperatures up to 1,200 degrees centigrade. Commercial applications are used in high speed aerodynamics, supersonic combustion, blade cooling, and mass flow measurements, etc.

Source record↗

Multimodality stereotactic brain tissue identification: the NASA smart probe project

Real-time tissue identification can benefit procedures such as stereotactic brain biopsy, functional neurosurgery and brain tumor excision. Optical scattering spectroscopy has been shown to be effective at discriminating cancer from noncancerous conditions in the colon, bladder and breast. The NASA Smart Probe extends the concept of 'optical biopsy' by using neural network techniques to combine the output from 3 microsensors contained within a cannula 2. 7 mm in diameter (i.e. the diameter of a stereotactic brain biopsy needle). Experimental data from 5 rats show the clear differentiation between tissues such as brain, nerve, fat, artery and muscle that can be achieved with optical scattering spectroscopy alone. These data and previous findings with other modalities such as (1) analysis of the image from a fiberoptic neuroendoscope and (2) the output from a microstrain gauge suggest the Smart Probe multiple microsensor technique shows promise for real-time tissue identification in neurosurgical procedures. Copyright 2000 S. Karger AG, Basel.

Non-programmatic↗

Cutting Edge Technologies Presentation: An Overview of Developing Sensor Technology Directions and Possible Barriers to New Technology Implementation

The aerospace industry requires the development of a range of chemical sensor technologies for such applications as leak detection, emission monitoring, fuel leak detection, environmental monitoring, and fire detection. A range of chemical sensors are being developed based on micromachining and microfabrication technology to fabricate microsensors with minimal size, weight, and power consumption; and the use of nanomaterials and structures to develop sensors with improved stability combined with higher sensitivity, However, individual sensors are limited in the amount of information that they can provide in environments that contain multiple chemical species. Thus, sensor arrays are being developed to address detection needs in such multi-species environments. These technologies and technical approaches have direct relevance to breath monitoring for clinical applications. This presentation gives an overview of developing cutting-edge sensor technology and possible barriers to new technology implementation. This includes lessons learned from previous microsensor development, recent work in development of a breath monitoring system, and future directions in the implementation of cutting edge sensor technology.

Hunter, Gary W.↗

Processing Nanostructured Sensors Using Microfabrication Techniques

Standard microfabrication techniques can be implemented and scaled to help assemble nanoscale microsensors. Currently nanostructures are often deposited onto materials primarily by adding them to a solution, then applying the solution in a thin film. This results in random placement of the nanostructures with no controlled order, and no way to accurately reproduce the placement. This method changes the means by which microsensors with nanostructures are fabricated. The fundamental advantage to this approach is that it enables standard microfabrication techniques to be applied in the repeated manufacture of nanostructured sensors on a microplatform.

Hunter, Gary W.↗