Search NASA⌕ Search

SEARCH · Search NASA

Results for “microwave filters”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

In-Band Scattering and Absorption of Infrared Blocking Foam Filters for Millimeter-wave Cameras

Expanded closed-cell polymer foams are widely used as thermal infrared (IR) blocking filters in millimeter-wave cameras, particularly for Cosmic Microwave Background observations. Precise knowledge of their millimeter-wave properties is essential for optimizing sensitivity. We present broadband (150 GHz - 2 THz) transmittance spectroscopy of Styroace-II and several Zotefoam filters, fitting their spectra with a radiative transfer model incorporating dielectric absorption and Rayleigh, Mie, and higher-order scattering. For a typical 5~cm thick filter stack at 280~GHz, Styroace-II exhibits ${\sim}10\%$ scattering with absorption estimated as ${\lesssim}5\%$ by effective-medium theory, while Zotefoam HD30 offers superior performance at ${\sim}3\%$ scattering and absorption likewise bounded to ${{\lesssim}0.3\%}$. Each model component is constrained at the ${\sim}0.1\%$ transmittance level for millimeter wavelengths. We observe batch-to-batch scattering variability of up to 2 percentage points in foams with multiple tested batches. Less commonly used Zotefoam formulations (LD15 and LD24) can further reduce in-band scattering to ${<}1\%$ while maintaining negligible in-band absorption and likely comparable IR blocking due to shared polyethylene absorption features and similar cell sizes. Based on this work, a filter constructed from the best measured LD24 batch has replaced the Styroace-II filter in a Simons Observatory 220/280 GHz Small Aperture Telescope.

Thomas, Alex [Chicago U., Astron. Astrophys. Ctr.;↗

The gravitational lensing imprints of DES Y3 superstructures on the CMB: a matched filtering approach

Low-density cosmic voids gravitationally lens the cosmic microwave background (CMB), leaving a negative imprint on the CMB convergence |$\kappa$|⁠. This effect provides insight into the distribution of matter within voids, and can also be used to study the growth of structure. We measure this lensing imprint by cross-correlating the Planck CMB lensing convergence map with voids identified in the Dark Energy Survey Year 3 (DES Y3) data set, covering approximately 4200 deg|$^2$| of the sky. We use two distinct void-finding algorithms: a 2D void-finder that operates on the projected galaxy density field in thin redshift shells, and a new code, Voxel, which operates on the full 3D map of galaxy positions. We employ an optimal matched filtering method for cross-correlation, using the Marenostrum Institut de Ciències de l’Espai N-body simulation both to establish the template for the matched filter and to calibrate detection significances. Using the DES Y3 photometric luminous red galaxy sample, we measure |$A_\kappa$|⁠, the amplitude of the observed lensing signal relative to the simulation template, obtaining |$A_\kappa = 1.03 \pm 0.22$| (⁠|$4.6\sigma$| significance) for Voxel and |$A_\kappa = 1.02 \pm 0.17$| (⁠|$5.9\sigma$| significance) for 2D voids, both consistent with Lambda cold dark matter expectations. We additionally invert the 2D void-finding process to identify superclusters in the projected density field, for which we measure |$A_\kappa = 0.87 \pm 0.15$| (⁠|$5.9\sigma$| significance). The leading source of noise in our measurements is Planck noise, implying that data from the Atacama Cosmology Telescope, South Pole Telescope and CMB-S4 will increase sensitivity and allow for more precise measurements.

79 ASTRONOMY AND ASTROPHYSICS↗

The 140 GHz notch filter development for millimeter-wave diagnostics protection on the stellarator Wendelstein 7-X

The notch filter plays a crucial role as a protective component in microwave diagnostics, primarily by addressing issues related to catastrophic interference. Designed for millimeter-wave diagnostics on the stellarator Wendelstein 7-X (W7-X), a WR-6 waveguide-based notch filter has been successfully developed to effectively isolate leakage from auxiliary heating gyrotrons operating at 140 GHz. The filter incorporates cylindrical cavities resonating at 140 GHz for the TE11p mode, with coupling structures that are designed and optimized for high-efficiency coupling. This configuration simplifies fabrication, thereby ensuring high-yield production. Experimental fabrication and in-house characterization confirm the notch filter's exceptional performance, with over 60 dB rejection in the vicinity of 140 GHz and low insertion loss (< 2 dB) above and below the notch frequency across a broad frequency bandwidth (121–138 GHz, 142–163 GHz). Furthermore, the utilization of this high-frequency structure fabrication technology can be applied to millimeter-wave diagnostics on other machines. In addition to the design elements of the notch filter, this paper also provides a detailed discussion of the fabrication process and methodology.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

In situ electric-field control of ferromagnetic resonance in the low-loss organic-based ferrimagnet V[TCNE] x ∼2

We demonstrate indirect electric-field control of ferromagnetic resonance (FMR) in devices that integrate the low-loss, molecule-based, room-temperature ferrimagnet vanadium tetracyanoethylene (V[TCNE]x∼2) mechanically coupled to PMN-PT piezoelectric transducers. Upon straining the V[TCNE]x films, the FMR frequency is tuned by more than 6 times the resonant linewidth with no change in Gilbert damping for samples with α = 6.5 × 10−5. We show this tuning effect is due to a strain-dependent magnetic anisotropy in the films and find the magnetoelastic coefficient |λs| ∼ (1–4.4) ppm, backed by theoretical predictions from density-functional theory calculations and magnetoelastic theory. Noting the rapidly expanding application space for strain-tuned FMR, we define a new metric for magnetostrictive materials, magnetostrictive agility, given by the ratio of the magnetoelastic coefficient to the FMR linewidth. This agility allows for a direct comparison between magnetostrictive materials in terms of their comparative efficacy for magnetoelectric applications requiring ultra-low loss magnetic resonance modulated by strain. With this metric, we show V[TCNE]x is competitive with other magnetostrictive materials, including YIG and Terfenol-D. This combination of ultra-narrow linewidth and magnetostriction, in a system that can be directly integrated into functional devices without requiring heterogeneous integration in a thin film geometry, promises unprecedented functionality for electric-field tuned microwave devices ranging from low-power, compact filters and circulators to emerging applications in quantum information science and technology.

Materials Science↗

Optimal filters for the moving lens effect

We assess the prospects for detecting the moving lens effect using cosmological surveys. The bulk motion of cosmological structure induces a small-scale dipolar temperature anisotropy of the cosmic microwave radiation, centered around halos and oriented along the transverse velocity field. We introduce a set of optimal filters for this signal and forecast that a high significance detection can be made with upcoming experiments. We discuss the prospects for reconstructing the bulk transverse velocity field on large scales using matched filters, finding good agreement with previous work using quadratic estimators.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Simulation-based Method for Correcting Mode Coupling in CMB Angular Power Spectra

Modern cosmic microwave background (CMB) analysis pipelines regularly employ complex time-domain filters, beam models, masking, and other techniques during the production of sky maps and their corresponding angular power spectra. However, these processes can generate couplings between multipoles from the same spectrum and from different spectra, in addition to the typical power attenuation. Within the context of pseudo-C ℓ based, MASTER-style analyses, the net effect of the time-domain filtering is commonly approximated by a multiplicative transfer function, F ℓ , that can fail to capture mode mixing and is dependent on the spectrum of the signal. To address these shortcomings, we have developed a simulation-based spectral correction approach that constructs a two-dimensional transfer matrix, ${J}_{{\ell }{\ell }^{\prime} }$, which contains information about mode mixing in addition to mode attenuation. We demonstrate the application of this approach on data from the first flight of the Spider balloon-borne CMB experiment.

79 ASTRONOMY AND ASTROPHYSICS↗

Advances in Processing, Manufacturing, and Applications of Magnetic Materials

Magnetic materials are increasingly important for many green energy technologies. Probably, the best known of these are permanent magnets. They are used to supply a magnetic field and are widely used in actuators, motors, generators, data storage, and sensors. These are “hard magnets,” meaning that they retain a large permanent magnetization (difficult to be demagnetized), which is what makes them so useful in motors where an opposing magnetic field can be used to push against them. A coercivity (resistance to demagnetization) of ~400 Oe (32,000 A/m) or more is typically the threshold value for a hard magnet and is typical of isotropic sintered ferrite (SrFe 12 O 19 ) such as found in many “refrigerator magnets.” Comparably important soft magnets are useful for directing magnetic fields and can be very easily (de)magnetized. As such, they typically have a coercivity < 12.5 Oe (1000 A/m), and specialized very soft magnets can have coercivities < 0.00125 Oe (1 A/m). Some common applications include coil cores, transformer cores, and magnetic shielding. Additionally, they are important for many AC electrical applications such as inductors, filters, and resonators, particularly at high frequencies up to and including microwaves.

36 MATERIALS SCIENCE↗

Droplet Number Concentration Value-Added Product

The ndrop_mfrsr value-added product (VAP) provides an estimate of the cloud droplet number concentration of overcast water clouds retrieved from cloud optical depth from the multi-filter rotating shadowband radiometer (MFRSR) instrument and liquid water path (LWP) retrieved from the microwave radiometer (MWR). When cloud layer information is available from vertically pointing lidar and radars in the Active Remote Sensing of Clouds (ARSCL) product, the VAP also provides estimates of the adiabatic LWP and an adiabatic parameter (beta) that indicates how divergent the LWP is from the adiabatic case. quality control (QC) flags (qc_drop_number_conc), an uncertainty estimate (drop_number_conc_toterr), and a cloud layer type flag (cloud_base_type) are useful indicators of the quality and accuracy of any given value of the retrieval. Examples of these major input and output variables are given in sample plots in section 6.0.

97 MATHEMATICS AND COMPUTING↗

On-Chip Single-Layer Integration of Diamond Spins with Microwave and Plasmonic Channels

On-chip scalable integration represents a major challenge for practical quantum devices. One particular challenge is to implement on-chip optical readout of spins in diamond. This readout requires simultaneous application of optical and microwave fields along with the efficient collection of fluorescence. These requirements are typically met using bulk optical components and dedicated microwave lines. Here, we experimentally demonstrate an on-chip integrated interface for diamond nitrogen vacancy (NV) spin-state preparation and readout, implemented in a planar single layer with only one patterning step. A nanodiamond with NV centers is positioned inside a v-groove waveguide milled in a thick gold film. The gold film carries the microwave control signal, while the v-groove acts as a fluorescence collector and, potentially, as an integrated pump filter. Hence, the device dimensions and fabrication complexity are substantially reduced. Our approach fosters further development of ultracompact nanoscale quantum sensors and quantum information processing devices on a monolithic platform.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Planck 2018 results - VIII. Gravitational lensing

We present measurements of the cosmic microwave background (CMB) lensing potential using the final Planck 2018 temperature and polarization data. Using polarization maps filtered to account for the noise anisotropy, we increase the significance of the detection of lensing in the polarization maps from 5σ to 9σ. Combined with temperature, lensing is detected at 40σ. We present an extensive set of tests of the robustness of the lensing-potential power spectrum, and construct a minimum-variance estimator likelihood over lensing multipoles 8 ≤ L ≤ 400 (extending the range to lower L compared to 2015), which we use to constrain cosmological parameters. We find good consistency between lensing constraints and the results from the Planck CMB power spectra within the ΛCDM model. Combined with baryon density and other weak priors, the lensing analysis alone constrains σ 8 Ωm 0.25 = 0.589 ± 0.020 (1σ errors). Also combining with baryon acoustic oscillation data, we find tight individual parameter constraints, σ8 = 0.811 ± 0.019, H0 = 67.9-1.3+1.2 km s -1 Mpc -1 , and Ω m = 0.303 -0.018 +0.016 . Combining with Planck CMB power spectrum data, we measure σ 8 to better than 1% precision, finding σ 8 = 0.811 ± 0.006. CMB lensing reconstruction data are complementary to galaxy lensing data at lower redshift, having a different degeneracy direction in σ 8 - Ω m space; we find consistency with the lensing results from the Dark Energy Survey, and give combined lensing-only parameter constraints that are tighter than joint results using galaxy clustering. Using the Planck cosmic infrared background (CIB) maps as an additional tracer of high-redshift matter, we make a combined Planck-only estimate of the lensing potential over 60% of the sky with considerably more small-scale signal. We additionally demonstrate delensing of the Planck power spectra using the joint and individual lensing potential estimates, detecting a maximum removal of 40% of the lensing-induced power in all spectra. The improvement in the sharpening of the acoustic peaks by including both CIB and the quadratic lensing reconstruction is detected at high significance.

79 ASTRONOMY AND ASTROPHYSICS↗

Characterization of Two Fast-Turnaround Dry Dilution Refrigerators for Scanning Probe Microscopy

Low-temperature scanning probe microscopes (SPMs) are critical for the study of quantum materials and quantum information science. Due to the rising costs of helium, cryogen-free cryostats have become increasingly desirable. However, they typically suffer from comparatively worse vibrations than cryogen-based systems, necessitating the understanding and mitigation of vibrations for SPM applications. Here, in this work, we demonstrate the construction of two cryogen-free dilution refrigerator SPMs with minimal modifications to the factory default and we systematically characterize their vibrational performance. We measure the absolute vibrations at the microscope stage with geophones and use both microwave impedance microscopy and a scanning single-electron transistor to independently measure tip-sample vibrations. Additionally, we implement customized filtering and thermal anchoring schemes and characterize the cooling power at the scanning stage and the tip electron temperature. This work serves as a reference to researchers interested in cryogen-free SPMs, as such characterization is not standardized in the literature or available from manufacturers.

36 MATERIALS SCIENCE↗

Low-loss Si-based Dielectrics for High Frequency Components of Superconducting Detectors

Silicon-based dielectric is crucial for many superconducting devices, including high-frequency transmission lines, filters, and resonators. Defects and contaminants in the amorphous dielectric and at the interfaces between the dielectric and metal layers can cause microwave losses and degrade device performance. Optimization of the dielectric fabrication, device structure, and surface morphology can help mitigate this problem. We present the fabrication of silicon oxide and nitride thin film dielectrics. We then characterized them using Scanning Electron Microscopy, Atomic Force Microscopy, and spectrophotometry techniques. The samples were synthesized using various deposition methods, including Plasma-Enhanced Chemical Vapor Deposition and magnetron sputtering. The film's morphology and structure were modified by adjusting the deposition pressure and gas flow. The resulting films were used in superconducting resonant systems consisting of planar inductors and capacitors. Measurements of the resonator properties, including their quality factor, were performed.

low-loss dielectrics↗

Silicon nitride stress-optic microresonator modulator for optical control applications

Modulation-based control and locking of lasers, filters and other photonic components is a ubiquitous function across many applications that span the visible to infrared (IR), including atomic, molecular and optical (AMO), quantum sciences, fiber communications, metrology, and microwave photonics. Today, modulators used to realize these control functions consist of high-power bulk-optic components for tuning, sideband modulation, and phase and frequency shifting, while providing low optical insertion loss and operation from DC to 10s of MHz. In order to reduce the size, weight and cost of these applications and improve their scalability and reliability, modulation control functions need to be implemented in a low loss, wafer-scale CMOS-compatible photonic integration platform. The silicon nitride integration platform has been successful at realizing extremely low waveguide losses across the visible to infrared and components including high performance lasers, filters, resonators, stabilization cavities, and optical frequency combs. Yet, progress towards implementing low loss, low power modulators in the silicon nitride platform, while maintaining wafer-scale process compatibility has been limited. Here we report a significant advance in integration of a piezo-electric (PZT, lead zirconate titanate) actuated micro-ring modulation in a fully-planar, wafer-scale silicon nitride platform, that maintains low optical loss (0.03 dB/cm in a 625 µm resonator) at 1550 nm, with an order of magnitude increase in bandwidth (DC - 15 MHz 3-dB and DC - 25 MHz 6-dB) and order of magnitude lower power consumption of 20 nW improvement over prior PZT modulators. The modulator provides a >14 dB extinction ratio (ER) and 7.1 million quality-factor (Q) over the entire 4 GHz tuning range, a tuning efficiency of 162 MHz/V, and delivers the linearity required for control applications with 65.1 dB·Hz 2/3 and 73.8 dB·Hz 2/3 third-order intermodulation distortion (IMD3) spurious free dynamic range (SFDR) at 1 MHz and 10 MHz respectively. We demonstrate two control applications, laser stabilization in a Pound-Drever Hall (PDH) lock loop, reducing laser frequency noise by 40 dB, and as a laser carrier tracking filter. This PZT modulator design can be extended to the visible in the ultra-low loss silicon nitride platform with minor waveguide design changes. This integration of PZT modulation in the ultra-low loss silicon nitride waveguide platform enables modulator control functions in a wide range of visible to IR applications such as atomic and molecular transition locking for cooling, trapping and probing, controllable optical frequency combs, low-power external cavity tunable lasers, quantum computers, sensors and communications, atomic clocks, and tunable ultra-low linewidth lasers and ultra-low phase noise microwave synthesizers.

Wang, Jiawei (ORCID:0000000257965220)↗

BEYONDPLANCK II. CMB mapmaking through Gibbs sampling

We present a Gibbs sampling solution to the mapmaking problem for cosmic microwave background (CMB) measurements that builds on existing destriping methodology. Gibbs sampling breaks the computationally heavy destriping problem into two separate steps: noise filtering and map binning. Considered as two separate steps, both are computationally much cheaper than solving the combined problem. This provides a huge performance benefit as compared to traditional methods and it allows us, for the first time, to bring the destriping baseline length to a single sample. Here, we applied the Gibbs procedure to simulated Planck 30 GHz data. We find that gaps in the time-ordered data are handled efficiently by filling them in with simulated noise as part of the Gibbs process. The Gibbs procedure yields a chain of map samples, from which we are able to compute the posterior mean as a best-estimate map. The variation in the chain provides information on the correlated residual noise, without the need to construct a full noise covariance matrix. However, if only a single maximum-likelihood frequency map estimate is required, we find that traditional conjugate gradient solvers converge much faster than a Gibbs sampler in terms of the total number of iterations. The conceptual advantages of the Gibbs sampling approach lies in statistically well-defined error propagation and systematic error correction. This methodology thus forms the conceptual basis for the mapmaking algorithm employed in the BEYONDPLANCK framework, which implements the first end-to-end Bayesian analysis pipeline for CMB observations.

79 ASTRONOMY AND ASTROPHYSICS↗

The XFaster Power Spectrum and Likelihood Estimator for the Analysis of Cosmic Microwave Background Maps

We present the XFaster analysis package, XFaster is a fast, iterative angular power spectrum estimator based on a diagonal approximation to the quadratic Fisher matrix estimator. XFaster uses Monte Carlo simulations to compute noise biases and filter transfer functions and is thus a hybrid of both Monte Carlo and quadratic estimator methods. In contrast to conventional pseudo-C ℓ based methods, the algorithm described here requires a minimal number of simulations, and does not require them to be precisely representative of the data to estimate accurate covariance matrices for the bandpowers. The formalism works with polarization-sensitive observations and also data sets with identical, partially overlapping, or independent survey regions. The method was first implemented for the analysis of BOOMERanG data (Netterfield et al. 2002; Jones et al. 2006), and also used as part of the Planck analysis (Rocha et al. 2011). Here, we describe the full, publicly available analysis package, written in Python, as developed for the analysis of data from the 2015 flight of the SPIDER instrument (SPIDER Collaboration 2021). The package includes extensions for self-consistently estimating null spectra and for estimating fits for Galactic foreground contributions. We show results from the extensive validation of XFaster using simulations, and its application to the SPIDER data set.

79 ASTRONOMY AND ASTROPHYSICS↗

Microwave radiometer, sun-photometer and GNSS multi-comparison of integrated water vapor in Southwestern Europe

This work presents a comparison of integrated water vapor (IWV) data recorded from microwave radiometer (MWR) and sun-photometer (SP) using global navigation satellite system (GNSS) IWV as reference in five mid-latitude sites of Portugal and Spain (2003–2021). A very high correlation is obtained for both instruments (R2 between 0.94 and 0.98), although, while MWR shows a wet bias, SP exhibits a dry one. In addition, a dependence of mean bias error (MBE) and standard deviation (SD) on IWV has been observed, increasing (larger discrepancies) both indices as IWV increases. The solar zenith angle (SZA) dependence is also studied, finding slightly larger discrepancies for the MWR than for SP in comparison with GNSS for very high values of SZA. Finally, a marked seasonal dependence is observed for SP-GNSS differences, modulated by the IWV dependence explained above. In contrast, the seasonal dependence for MWR is quite weaker than it is for SP. Therefore, in spite of the excellent agreement found among the different instruments, it is recommended that: i) the dependence with IWV be studied and corrected to further increase the performance of the instruments, and ii) metadata be used to filter out situations in which the instrument cannot operate properly.

54 ENVIRONMENTAL SCIENCES↗

Bicep/Keck XV: The Bicep3 Cosmic Microwave Background Polarimeter and the First Three-year Data Set

Abstract We report on the design and performance of the B icep3 instrument and its first three-year data set collected from 2016 to 2018. B icep3 is a 52 cm aperture refracting telescope designed to observe the polarization of the cosmic microwave background (CMB) on degree angular scales at 95 GHz. It started science observation at the South Pole in 2016 with 2400 antenna-coupled transition-edge sensor bolometers. The receiver first demonstrated new technologies such as large-diameter alumina optics, Zotefoam infrared filters, and flux-activated SQUIDs, allowing ∼10× higher optical throughput compared to the Keck design. B icep3 achieved instrument noise equivalent temperatures of 9.2, 6.8, and 7.1 μ K CMB s and reached Stokes Q and U map depths of 5.9, 4.4, and 4.4 μ K arcmin in 2016, 2017, and 2018, respectively. The combined three-year data set achieved a polarization map depth of 2.8 μ K arcmin over an effective area of 585 square degrees, which is the deepest CMB polarization map made to date at 95 GHz.

79 ASTRONOMY AND ASTROPHYSICS↗