27 records · Page 2

Resonance testing of space shuttle thermoacoustic structural specimen

The resonance testing of a structural specimen related to the space shuttle vehicle is described. The specimen consisted of a thin aluminum skin reinforced by hat-section stringers and supported by two ribs or bulkheads of corrugated web. A representative section of the space shuttle thermal protection system was bonded to the outer surface of the skin. The tests were completed by using miniature accelerometers to collect vibration data from locations forming a predetermined mesh over the tiles and base structure. The signals were recorded on FM magnetic tape and subsequently analyzed on a modal analysis system.

Abrahamson, A. L.↗

Precision Subsampling System for Mars Surface Missions

The ability to analyze heterogeneous rock samples at fine spatial scales would represent a powerful addition to our planetary in situ analytical toolbox. This is particularly true for Mars, where the signatures of past environments and, potentially, habitability are preserved in chemical and morphological variations across sedimentary layers and among mineral pr.ases in a given rock specimen. On Earth, microbial life often associates with surfaces at the interface of chemical nutrients, and ultimately retains sub-millimeter to millimeter-scale layer confinement in fossilization. On Mars, and possibly other bodies, trace chemical markers (elemental, organic/molecular, isotopic, chiral, etc.) and fine-scale morphological markers (e.g., micro-fossils) may he too subtle, degraded, or ambiguous to be detected, using miniaturized instrumentation, without some concentration or isolation. This is because (i) instrument sensitivity may not be high enough to detect trace markers in bulk averages; and (ii) instrument s~lectiviry may not be sufficient to distinguish such markers from interfering/counteracting signals from the bulk. Moreover from a fundamental chemostratigraphic perspective there would be a great benefit to assessing specific chemical and stable isotopic gradients, over millimeter-to-centimeter scales and beyond, with higher precision than currently possible in situ. We have developed a precision subsampling system (PSS) that addresses this need while remaining relatively flexible to a variety of instruments that may take advantage of the capability on future missions. The PSS is relevant to a number of possible lander/rover missions, especially Mars Sample Return. Our specific PSS prototype is undergoing testing under Mars ambient conditions, on a variety of natural analog rocks and rock drill cores, using a set of complementary flight-compatible measurement techniques. The system is available for testing with other contact instruments that may benefit from precision sampling.

Mahaffy, P. R.↗

A sub-cm micromachined electron microscope

A new approach for fabricating macroscopic (approximately 10x10x10 mm(exp 3)) structures with micron accuracy has been developed. This approach combines the precision of semiconductor processing and fiber optic technologies. A (100) silicon wafer is anisotropically etched to create four orthogonal v-grooves and an aperture on each 10x12 mm die. Precision 308 micron optical fibers are sandwiched between the die to align the v-grooves. The fiber is then anodically bonded to the die above and below it. This procedure is repeated to create thick structures and a stack of 5 or 6 die will be used to create a miniature scanning electron microscope (MSEM). Two die in the structure will have a segmented electrode to deflect the beam and correct for astigmatism. The entire structure is UHV compatible. The performance of an SEM improves as its length is reduced and a sub-cm 2 keV MSEM with a field emission source should have approximately 1 nm resolution. A low voltage high resolution MSEM would be useful for the examination of biological specimens and semiconductors with a minimum of damage. The first MSEM will be tested with existing 6 micron thermionic sources. In the future a micromachined field emission source will be used. The stacking technology presented in this paper can produce an array of MSEMs 1 to 30 mm in length with a 1 mm or larger period. A key question being addressed by this research is the optimum size for a low voltage MSEM which will be determined by the required spatial resolution, field of view, and working distance.

Feinerman, A. D.↗

Enhanced Imaging of Corrosion in Aircraft Structures with Reverse Geometry X-ray(registered tm)

The application of Reverse Geometry X-ray to the detection and characterization of corrosion in aircraft structures is presented. Reverse Geometry X-ray is a unique system that utilizes an electronically scanned x-ray source and a discrete detector for real time radiographic imaging of a structure. The scanned source system has several advantages when compared to conventional radiography. First, the discrete x-ray detector can be miniaturized and easily positioned inside a complex structure (such as an aircraft wing) enabling images of each surface of the structure to be obtained separately. Second, using a measurement configuration with multiple detectors enables the simultaneous acquisition of data from several different perspectives without moving the structure or the measurement system. This provides a means for locating the position of flaws and enhances separation of features at the surface from features inside the structure. Data is presented on aircraft specimens with corrosion in the lap joint. Advanced laminographic imaging techniques utilizing data from multiple detectors are demonstrated to be capable of separating surface features from corrosion in the lap joint and locating the corrosion in multilayer structures. Results of this technique are compared to computed tomography cross sections obtained from a microfocus x-ray tomography system. A method is presented for calibration of the detectors of the Reverse Geometry X-ray system to enable quantification of the corrosion to within 2%.

Winfree, William P.↗

Development of a Point of Care Technology for Military Medical Applications in Austere Environments

NASA, Lawrence Livermore National Laboratory (LLNL) and the Department of Defense (DoD) share a common interest in compact medical diagnostic technologies—also known as “point of care testing” (POCT) technologies. For NASA, the need is to take care of astronauts on deep space missions. For LLNL, the focus is on technologies needed to support homeland security applications. For DoD, the need is to support warfighters in military theaters of operation, especially for prolonged field care and en route care. A recently patented technology, “Portable Medical Diagnosis Instrument” (U.S. Patent 9824870), co-invented by NASA and LLNL, is being developed further in a partnership between NASA, LLNL and Travis Air Force Base, with a focus on military applications. This instrument, the NASA-LLNL Medical Tricorder, can be used for a wide range of clinical samples including breath, saliva and blood. One component of the Tricorder is the NASA E-Nose, a carbon nanotube-based chemical sensor, integrated into a hand-held smart phone, that can detect and measure “breath biomarkers” in the gas phase of exhaled breath. The response of the NASA E-Nose is rapid, which makes it possible to detect various gas-phase substances in real time. The NASA E-Nose, with modification, can also be used for breath condensate analysis. Another component of the Tricorder is a miniaturized microfluidic analyzer, under development by LLNL, that does not require any pumps. The microfluidic analyzer can detect and measure biomarkers in liquid samples, such as blood, saliva and breath condensate. This microfluidic system requires small quantities of liquid sample and can perform analysis very rapidly (seconds to minutes), which makes it possible to detect relevant biomarkers in near real time in the field. The Clinical Investigation Facility (CIF) at Travis Air Force Base is currently conducting research with the goal to develop improved field-able technologies and procedures for the emergency response to life threatening injuries soldiers may receive in theater. This work includes experimental large animal systems and comprehensive collection of clinical specimens and physiological data. NASA and LLNL are partnering with Travis to test and further develop the Tricorder technology for high priority military applications, initially focused on lung injury models and traumatic brain injury.

Loftus, David J.↗

Miniature Variable Pressure Scanning Electron Microscope for In-Situ Imaging and Chemical Analysis

NASA Marshall Space Flight Center (MSFC) is leading an effort to develop a Miniaturized Variable Pressure Scanning Electron Microscope (MVP-SEM) for in-situ imaging and chemical analysis of uncoated samples. This instrument development will be geared towards operation on Mars and builds on a previous MSFC design of a mini-SEM for the moon (funded through the NASA Planetary Instrument Definition and Development Program). Because Mars has a dramatically different environment than the moon, modifications to the MSFC lunar mini-SEM are necessary. Mainly, the higher atmospheric pressure calls for the use of an electron gun that can operate at High Vacuum, rather than Ultra-High Vacuum. The presence of a CO2-rich atmosphere also allows for the incorporation of a variable pressure system that enables the in-situ analysis of nonconductive geological specimens. Preliminary testing of Mars meteorites in a commercial Environmental SEM(Tradmark) (FEI) confirms the usefulness of lowcurrent/low-accelerating voltage imaging and highlights the advantages of using the Mars atmosphere for environmental imaging. The unique capabilities of the MVP-SEM make it an ideal tool for pursuing key scientific goals of NASA's Flagship Mission Max-C; to perform in-situ science and collect and cache samples in preparation for sample return from Mars.

Gaskin, Jessica A.↗

A magnetic field measurement technique using a miniature transducer

The development, fabrication, and application of a magnetometer are described. The magnetometer has a miniature transducer and is capable of automatic scanning. The magnetometer described here is capable of detecting static magnetic fields as low as 1.6 A/m and its transducer has an active area 0.64 mm by 0.76 mm. Thin and rugged, the transducer uses wire, 0.05 mm in diameter, which is plated with a magnetic film, enabling measurement of transverse magnetic fields as close as 0.08 mm from a surface. The magnetometer, which is simple to operate and has a fast response, uses an inexpensive clip-on milliammeter (commonly found in most laboratories) for driving and processing the electrical signals and readout. A specially designed transducer holding mechanism replaces the XY recorder ink pen; this mechanism provides the basis for an automatic scanning technique. The instrument has been applied to the measurements of magnetic fields arising from remanent magnetization in experimental plated-wire memory planes and regions of magnetic activity in geological rock specimens.

Fales, C. L., Jr.↗

NASA Tech Briefs, November 2006

Topics include: Simulator for Testing Spacecraft Separation Devices; Apparatus for Hot Impact Testing of Material Specimens; Instrument for Aircraft-Icing and Cloud-Physics Measurements; Advances in Measurement of Skin Friction in Airflow; Improved Apparatus for Testing Monoball Bearings; High-Speed Laser Scanner Maps a Surface in Three Dimensions; Electro-Optical Imaging Fourier-Transform Spectrometer; Infrared Instrument for Detecting Hydrogen Fires; Modified Coaxial Probe Feeds for Layered Antennas; Detecting Negative Obstacles by Use of Radar; Cryogenic Pound Circuits for Cryogenic Sapphire Oscillators; PixelLearn; New Software for Predicting Charging of Spacecraft; Conversion Between Osculating and Mean Orbital Elements; Generating a 2D Representation of a Complex Data Structure; Making Activated Carbon by Wet Pressurized Pyrolysis; Composite Solid Electrolyte Containing Li+- Conducting Fibers; Electrically Conductive Anodized Aluminum Surfaces; Rapid-Chill Cryogenic Coaxial Direct-Acting Solenoid Valve; Variable-Tension-Cord Suspension/Vibration- Isolation System; Techniques for Connecting Superconducting Thin Films; Versatile Friction Stir Welding/Friction Plug Welding System; Thermal Spore Exposure Vessels; Enumerating Spore-Forming Bacteria Airborne with Particles; Miniature Oxidizer Ionizer for a Fuel Cell; Miniature Ion-Array Spectrometer; Promoted-Combustion Chamber with Induction Heating Coil; Miniature Ion-Mobility Spectrometer; Mixed-Salt/Ester Electrolytes for Low-Temperature Li+ Cells; Miniature Free-Space Electrostatic Ion Thrusters; Miniature Bipolar Electrostatic Ion Thruster; Holographic Plossl Retroreflectors; Miniature Electrostatic Ion Thruster With Magnet; Using Apex To Construct CPM-GOMS Models; Sequence Detection for PPM Optical Communication With ISI; Algorithm for Rapid Searching Among Star-Catalog Entries; Expectation-Based Control of Noise and Chaos; Radio Heating of Lunar Soil to Release Gases; Using Electrostriction to Manipulate Ullage in Microgravity; Equations for Scoring Rules When Data Are Missing; Insulating Material for Next-Generation Spacecraft; and Pseudorandom Switching for Adding Radar to the AFF Sensor.

Source record↗

Onorbit electron beam welding experiment definition

The proposed experiment design calls for six panels to be welded, each having unique characteristics selected to yield specific results and information. The experiment is completely automated and the concept necessitated the design of a new, miniaturized, self-contained electron beam (EB) welding system, for which purpose a separate IR and D was funded by the contractor, Martin Marietta Corporation. Since future tasks beyond the proposed experiment might call for astronauts to perform hand-held EB gun repairs or for the gun to be interfaced with a dexterous robot such as the planned flight telerobotic servicer (FTS), the EB gun is designed to be dismountable from the automated system. In the experiment design, two separate, identical sets of weld panels will be welded, one on earth in a vacuum chamber and the other onorbit in the aft cargo bay of an orbiter. Since the main objective of the experiment is to demonstrate that high quality welds can be achieved under onorbit conditions, the welds produced will be subjected to a wide range of discriminating non-destructive Q.C. procedures and destructive physical tests. However, advantage will be taken of the availability of a fairly large quantity of welded material in the two series of welded specimens to widen the circle of investigative talent by providing material to academic and scientific institutions for examination.

William H. Hooper↗