Search NASA⌕ Search

SEARCH · Search NASA

Results for “miniature specimen”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

ORNL Post-irradiation Examination (LAMDA) Final Report on Characterization of Irradiated Grade 92 Ferritic-Martensitic Steels

Irradiation effects on ferritic-martensitic steel Grade 92 were investigated in this project. Samples from two heats of Grade 92, i.e., G92-2b and NF616, were selected, which were irradiated in the High Flux Isotope Reactor (HFIR) and the Advanced Test Reactor (ATR), respectively. Samples from two heats of ferriticmartensitic steel T91, irradiated in the ATR, were also selected as references for the Grade 92 samples. The selected G92-2b samples were irradiated to 0.5–14.7 displacements per atom (dpa) at two temperature regimes: 400–497 °C and 683–720°C. The selection of the high irradiation temperatures up to ~720°C is to test the performance at such upper bound temperatures, which would provide insights for the upper bound applicable temperature for Grade 92. The selected NF616 and T91 samples were irradiated to 3–8.2 dpa at 292–448°C. Except for T91 heat2 samples in 3-mm diameter discs, all the other selected samples are of type SS-J2 miniature tensile specimens. Two Nuclear Science User Facilities (NSUF), i.e., the Irradiated Materials Examination and Testing (IMET) hot cell facility and the Low Activation Materials Design and Analysis (LAMDA) facility, were used in the Post-Irradiation Examination (PIE) activities for the selected samples, which include: Tensile tests at room temperature (IMET); Fractography of the tensile fracture surfaces (LAMDA: scanning electron microscopy and energy; dispersive spectroscopy); Vickers hardness measurements (LAMDA); and Microstructural characterization (LAMDA: electron backscatter diffraction, focused-ion beam, and transmission electron microscopy).

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Mechanical Properties of Additively Manufactured 316L Stainless Steel Before and After Neutron Irradiation (FY21)

This report presents the materials property data of additively manufactured (AM) 316L stainless steel (SS) accumulated for the assessment of core materials in the Transformational Challenge Reactor (TCR) program. The TCR manufacturing approach includes using the laser powder bed fusion (LPBF) method for metallic (316L and Inconel 718) components. To assess the mechanical performance of printed components in reactor-relevant conditions and build a property database for the AM materials, mechanical tests and evaluations were performed before and after neutron irradiation. Miniature tensile specimens were irradiated in the High Flux Isotope Reactor to 0.2, 2, 8, and 10 dpa at target temperatures of 300 and 600°C. Postirradiation evaluation for the 0.2 and 2 dpa specimens was performed during FY20 and FY21, and the results are presented and discussed in this document.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Mechanical Properties of Additively Manufactured 316L Stainless Steel Before and After Neutron Irradiation–FY23

This report presents the observed mechanical behavior of the additively manufactured (AM) 316L stainless steel (SS) before and after neutron irradiation. In the Advanced Materials and Manufacturing Technologies (AMMT) program, a variety of mechanical and physical property data are generated and accumulated to assess the AM austenitic alloy for nuclear reactor applications. The testing and evaluation task in the FY 2023 focused on elucidating the effects of sampling location and build size on the mechanical properties of AM 316L SS (in stress-relieved condition) before and after neutron irradiation. The laser powder bed fusion (LPBF) process produced 316L plates of three distinct sizes from which SS-J3 miniature tensile specimens were machined from six different locations. The tensile specimens were irradiated in the High Flux Isotope Reactor (HFIR) normally to 2 and 10 dpa at the target temperatures of 300 °C and 600 °C. Post-irradiation tensile testing was performed at room temperature, 300 °C, and 600 °C. The mechanical properties of AM 316L SS were significantly influenced by the characteristic microstructures of printed materials, which include fine grains and high-density dislocations. Compared with the traditional 316L SS, AM 316L showed higher initial strength and lower ductility. Regardless of sampling location, the AM 316L steel retained relatively high strength and ductility to the highest irradiation dose. A prompt necking at yield (with little uniform ductility) was observed after irradiation at 300 °C but no embrittlement was observed up to 10 dpa. Ductilization by irradiation–the radiation-induced increase of ductility–was observed for the 600 °C irradiation only and it occurred in low dose range only. The neutron irradiation increased the data variation in many tensile property datasets, particularly after 600 °C irradiation, and no clear dependence of tensile properties on build thickness or sampling location was observed.

36 MATERIALS SCIENCE↗

Post-Irradiation Examination to Quantify Irradiation-Induced Bowing of SiGA® Silicon Carbide Composite Structures (Final CRADA Report – NFE-23-09937)

As part of the SiC-based material development at General Atomics Electromagnetic Systems (GA-EMS), this project involved the first-of-a-kind experimental post-irradiation examination of the irradiation-induced bowing response in SiC composite structures under a neutron flux gradient. The SiC composite miniature channel specimen was provided by GA-EMS for the irradiation experiment. To quantify the irradiation-induced bowing of the channel specimen, a series of visual and dimensional inspections were conducted using the unique capabilities at Oak Ridge National Laboratory (ORNL), including a custom profilometry rig. The post-irradiation examination results of this project will assist GA-EMS in validating their fuel performance model for SiC-based core structures in neutron irradiation environments.

36 MATERIALS SCIENCE↗

Analysis of Deformation and Fracture Mechanisms in the Harvested High-Dose Baffle-Former Bolt with Stress-Corrosion Cracks Formed While in Service

This report presents the results of advanced mechanical testing conducted on miniature tensile specimens excised from an irradiated baffle-former bolt, a commercial pressurized water reactor component. The specimens were extracted from the midsection of the bolt shank, where the estimated damage dose reached 23 displacements per atom. The mechanical testing included the following tests: (1) conventional tensile testing at room temperature, augmented by digital image correlation (DIC) to enable noncontact strain measurements, and (2) in situ tensile testing within a scanning electron microscopy (SEM) instrument equipped with energy-dispersive x-ray spectroscopy (EDS) and electron backscatter diffraction (EBSD) detectors to evaluate active deformation and fracture mechanisms. Additionally, SEM fractographic analysis revealed alterations in the fracture mechanism from a predominantly ductile fracture in nonirradiated steel to a mixed fracture mode (still dominating ductile and minor cleavage spots) in irradiated specimens derived from the baffle bolts. The findings indicate a complex strain localization behavior for in-service irradiated steel specimens. Beyond conventional necking at the macro scale and defect-free channel formation at the micro scale, DIC results identified the presence of deformation bands approximately 100 μm in width. These bands consist of chains of grains exhibiting elevated local strain levels and may be considered an intermediate or mesoscale level of strain localization. These bands become discernible near the yield stress as localized hot spots, areas of elevated strain, persisting throughout most of the experiment. The formation of mesoscale deformation bands as a strain localization mechanism may exacerbate the defect-free channel formation in irradiated materials, further promoting irradiation-assisted stress corrosion crack initiation.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Analysis of Deformation Mechanisms, Strain Localization, and Fracture in Highly Irradiated Austenitic Steels – Light-Water Reactor Core Materials – via Advanced inSEM Techniques

The present report describes the establishing of an advanced experimental approach – high-resolution digital image correlation or µDIC – for testing miniature irradiated specimens in the ORNL’s Low Activation Materials Development and Analysis (LAMDA) facility. As expected, the µDIC approach will allow for studying strain localization inside grains, for instance, during dislocation channel-grain boundary interaction processes. This information is of high importance for understanding degradation processes in irradiated austenitic steels – in-core materials of Light Water Reactors. The Level 4 report provides a brief introduction, lists materials designated for µDIC testing and delivered in LAMDA this FY, discusses methodical concerns and preliminary observations.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Demonstrate embedding of sensors in a relevant microreactor component

This report describes the first successful embedding of sensors in stainless steel pipe specimens and a miniature hex block to support structural health monitoring of microreactor components during electrically heated testing in non-nuclear testbed facilities. Sensors were embedded with an ultrasonic additive manufacturing process that uses a combination of downward pressure and an ultrasonic scrubbing motion to bond stainless steel foils to underlying materials. After placing sensors within cavities that have been machined to the size of the sensors, the ultrasonic bonding process fills the gaps around the sensors and embeds them within the part. Both Type K thermocouples and spatially distributed fiber-optic strain sensors were successfully embedded within two pipe specimens and a miniature hex block. After the fiber-optic sensors were embedded, they were interrogated and found to have minimal signal attenuation within the embedded region—a significant improvement compared to previous trials. This is likely because of the low-bend-loss fiber that was used, which greatly reduces microbending losses that occur after the embedding process. In addition to showing minimal signal attention, the fibers also showed adequate compressive strain, which is a strong indication that the sensors are physically embedded in the parts as opposed to simply being loosely contained inside the machined cavities. The embedded fibers were able to capture the strain induced in one of the pipe specimens while the pipe was actively heated with a moving heat source.

42 ENGINEERING↗

Irradiation-assisted Stress Corrosion Cracking of PWRirradiated Type 347 Stainless Steel (NSUF CINR 19-16567)

This document serves as the final report for NSUF Project 19-16567 (Reference 1) and its supporting contracts (References 2 and 3). It documents completion of testing of specimens fabricated as previously described in Reference 4. At a high level, the purpose of the testing is to generate data to support continued operation of light water reactors (LWR) and provide further understanding of irradiation-assisted stress corrosion crack (IASCC) initiation in baffle-former bolt materials. Baffle-former bolts that had been extracted from commercial pressurized water reactors (PWRs) were machined into miniature 4-point bend specimens and TEM samples at the Westinghouse Churchill Site hot cell facility. These samples were then shipped to the University of Michigan to undergo IASCC initiation testing in simulated PWR primary coolant containing either LiOH or KOH additions. Overall, 15 samples were tested, 8 in water with KOH additions and 7 in water with LiOH additions, until indications of cracking were observed. Crack initiation stress was similar in both water environments at 50-60% of the irradiated yield stress. Post-test examination of the cracking sites, including scanning electron microscopy and transmission electron microscopy, demonstrated that the crack initiation mechanism and crack initiation rates were similar between the two different water chemistries. A grain boundary oxidation and oxide fracture mechanism was observed to be responsible for crack initiation.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Process–Property–Performance Mapping of Additively Manufactured 316H Stainless Steel Components

The Advanced Materials and Manufacturing Technologies Program is focused on accelerating the development of advanced materials and components fabricated via additive manufacturing, and is using laser powder bed fusion (LPBF) of 316H stainless steel as an initial case study. In the previous fiscal year, miniature high-throughput specimens were printed on multiple LPBF systems to provide initial processing windows to minimize porosity and limit epitaxial grain growth during prints. This fiscal year, scaled builds were completed on three different LPBF systems at ORNL: a GE Concept Laser M2, a Renishaw AM400, and an EOS M290. Builds on the Concept Laser were conducted on multiple powder lots and processing parameter ranges to provide microstructure effects on time-independent and time-dependent mechanical properties. Builds on the Renishaw were produced using Oak Ridge National Laboratory (ORNL)-optimized printing parameters and Argonne National Laboratory (ANL)-optimized printing parameters to compare outcomes of parallel process optimization efforts at different national laboratories on the same LPBF system. Similarly, the build completed on the EOS M290 replicated the processing parameters of builds completed at Los Alamos National Laboratory (LANL). Optical microscopy and electron backscatter diffraction characterization was completed on all builds. In addition to the general round robin characterization, this work-package generated time-independent data, including tensile and fracture toughness test data on scaled Concept Laser builds as a function of processing parameters and post-build heat treatment. This analysis is complimentary to work in parallel work packages aiming to establish heat treatment and processing effects on time-dependent properties. It was found that although the stress-relief heat treatment provides the highest strength at lower-temperatures, tensile strength begins to converge at higher temperatures regardless of heat treatment condition. In addition, the more rigorous solution annealing and hot-isostatic pressing post-build heat treatments result in higher fracture toughness than the stress-relieved condition. The root-causes of the lower fracture toughness of the stress-relieved LPBF 316H material was informed via a stress-relief optimization study on a scaled concept laser print, where it was found that although dislocation recovery was largely complete after only a couple hours at 650°C, the extended hold of the current 24h heat treatment employed on scaled builds likely caused increased carbide volume fractions along the LPBF 316H grain boundaries, thereby deteriorating crack propagation resistance. This trend was seen to become more deleterious with additional increases of stress-relief temperature to 750°C or 850°C. These results have helped inform a new optimal stress-relief annealing condition for LPBF 316H for future campaign testing (650°C for 2h).

36 MATERIALS SCIENCE↗

Process–Property–Performance Mapping of Additively Manufactured 316H Stainless Steel Components

The Advanced Materials and Manufacturing Technologies Program is focused on accelerating the development of advanced materials and components fabricated via additive manufacturing, and is using laser powder bed fusion (LPBF) of 316H stainless steel as an initial case study. In the previous fiscal year, miniature high-throughput specimens were printed on multiple LPBF systems to provide initial processing windows to minimize porosity and limit epitaxial grain growth during prints. This fiscal year, scaled builds were completed on three different LPBF systems at ORNL: a GE Concept Laser M2, a Renishaw AM400, and an EOS M290. Builds on the Concept Laser were conducted on multiple powder lots and processing parameter ranges to provide microstructure effects on time-independent and time-dependent mechanical properties. Builds on the Renishaw were produced using Oak Ridge National Laboratory (ORNL)-optimized printing parameters and Argonne National Laboratory (ANL)-optimized printing parameters to compare outcomes of parallel process optimization efforts at different national laboratories on the same LPBF system. Similarly, the build completed on the EOS M290 replicated the processing parameters of builds completed at Los Alamos National Laboratory (LANL). Optical microscopy and electron backscatter diffraction characterization was completed on all builds. In addition to the general round robin characterization, this work-package generated time-independent data, including tensile and fracture toughness test data on scaled Concept Laser builds as a function of processing parameters and post-build heat treatment. This analysis is complimentary to work in parallel work packages aiming to establish heat treatment and processing effects on time-dependent properties. It was found that although the stress-relief heat treatment provides the highest strength at lower-temperatures, tensile strength begins to converge at higher temperatures regardless of heat treatment condition. In addition, the more rigorous solution annealing and hot-isostatic pressing post-build heat treatments result in higher fracture toughness than the stress-relieved condition. The root-causes of the lower fracture toughness of the stress-relieved LPBF 316H material was informed via a stress-relief optimization study on a scaled concept laser print, where it was found that although dislocation recovery was largely complete after only a couple hours at 650°C, the extended hold of the current 24h heat treatment employed on scaled builds likely caused increased carbide volume fractions along the LPBF 316H grain boundaries, thereby deteriorating crack propagation resistance. This trend was seen to become more deleterious with additional increases of stress-relief temperature to 750°C or 850°C. These results have helped inform a new optimal stress-relief annealing condition for LPBF 316H for future campaign testing (650°C for 2h).

36 MATERIALS SCIENCE↗

In situ synchrotron tensile investigations on ultrasonic additive manufactured (UAM) zirconium

The microstructure evolution during room temperature uniaxial tensile straining of ultrasonic additive manufactured (UAM) zirconium was evaluated using the Advanced Photon Source (APS) facility. Miniature dog-bone tensile specimens of two orientations were cut from a UAM-fabricated zirconium bar for in situ synchrotron tensile tests. Wide-angle X-ray scattering (WAXS) scanning was used to unveil the changes in microstructure of the entire gauge regions throughout the straining. A series of WAXS data analysis methods were utilized to quantify both elastic and plastic deformation mechanisms within the strained specimens. Stress concentrations were identified during early stages of plastic deformation, which become candidate necking positions and eventually lead to failure. Additionally, fracture surface analysis implied that these stress concentration locations may be correlated to the fabrication defects, providing insightful guidance for future improvements of the UAM zirconium fabrication process.

36 MATERIALS SCIENCE↗

In Situ Synchrotron Tensile Investigations on Ultrasonic Additive Manufactured (UAM) Zirconium

The microstructure evolution of ultrasonic additive manufactured (UAM) zirconium under room temperature uniaxial tensile straining is reported. Miniature dog-bone tensile specimens of two orientations were cut from a UAM zirconium bar for in situ synchrotron tensile tests. Wide-angle X-ray scattering (WAXS) scanning at the Advanced Photon Source (APS) at Argonne National Laboratory was used to unveil the changes in microstructure of the entire gauge regions throughout the straining. A series of WAXS data analysis methods were utilized to quantify both elastic and plastic deformation mechanisms within the strained specimens. Stress concentrations were identified during early stage of plastic deformation, which become candidate necking positions and eventually lead to failure. Fracture surface analysis implied that these stress concentration locations may be correlated to the fabrication defects, providing insightful guidance for future improvement of the UAM zirconium process.

36 MATERIALS SCIENCE↗

Screening and qualification methodology for SiC end plug processing methods

Deployment of SiC-ceramic-based fuel cladding for light water reactors requires a hermetic end plug–to–cladding joint that can withstand neutron irradiation during normal operation and maintain integrity during design-basis accidents. Reactor experiments have shown that some SiC composite tubes with SiC end plugs can retain hermeticity after irradiation. However, achieving consistent joint performance under irradiation remains a key challenge. Resolving this issue is essential to enable integral irradiation testing and to demonstrate fuel integrity under commercial-reactor irradiation conditions. This report aims to: (1) provide guidance for designing radiation-tolerant end plug joints for SiC cladding; (2) demonstrate experimental methods to detect processing defects that are unstable under neutron irradiation at light-water-reactor-relevant temperatures and doses; and (3) outline a step-by-step approach for designing and conducting reactor experiments to screen joining methods. The resulting data will be used to improve joint processing and to define critical defect types and sizes that must be detected and eliminated through non-destructive evaluation for quality assurance. Based on prior irradiation experiments at the High Flux Isotope Reactor, differential swelling among the cladding, bonding layer, and end plug was identified as an underlying mechanism for irradiation-induced joint degradation. Accordingly, this effect must be considered in the design of radiation-tolerant joining techniques. In this work, miniature SiC end plug joint specimens irradiated during the previous project were analyzed using X-ray computed tomography to characterize the joint microstructure. Digital volume correlation of the tomography data quantified radiation-induced microstructural changes and enabled evaluation of defect-related risks. Finally, ongoing neutron irradiation efforts using larger specimen volumes are presented. These efforts aim to statistically assess joint performance and to build a microstructure–performance (e.g., leak-tightness) dataset to inform processing improvements and quality control.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

HFIR SiC Bowing Test Ready to Insert

This report describes the successful assembly of a High Flux Isotope Reactor (HFIR) irradiation experiment designed to assess radiation-induced lateral bowing of silicon carbide fiber–reinforced, silicon carbide matrix composite (SiC/SiC) components under a radial fast neutron flux gradient. Excessive bowing of a SiC/SiC channel box in a boiling water reactor could potentially interfere with control blade movements. Similar concerns exist for SiC/SiC fuel cladding in light water reactors. The experiment described herein will provide experimental validation of the structural response of a miniature SiC/SiC channel box and tube specimens with pressurized water reactor diameters during irradiation. The significant radial fast neutron flux gradients that exist in the permanent reflector of HFIR were characterized using detailed three-dimensional neutronic calculations. The three-dimensional displacement damage dose rate profile and the resulting volumetric swelling in SiC were used as inputs to structural analyses that predicted the deformation and stresses in the channel box specimen. The specimens were thoroughly characterized prior to irradiation using traditional dimensional inspection and surface profilometry so that these measurements can later be compared with similar measurements that will be made post-irradiation to determine radiation-induced deformations. Furthermore, fine engraving markers were inscribed along all outer surfaces of the specimen and mapped using a digital microscope and a three-dimensional stage. This technique allowed for accurate measurements of the marker spacings, which can be compared with similar measurements that will be made post-irradiation to provide local radiation-induced strain mapping. The experiment was successfully assembled and is scheduled for insertion during HFIR cycle 492, which is currently scheduled to run from May 25, 2021 to June 18, 2021.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Initial development of an in-situ, passive material surveillance test article for monitoring high temperature reactor structural components

This report describes the development of a family of passively-actuated surveillance test articles, suitable for use in an in-situ reactor test program monitoring the degradation in structural material properties caused by the reactor environment. The test articles apply creep-fatigue-type cyclic load to a test section driven by changes in the reactor coolant temperature converted to mechanical force by differential thermal expansion. The report describes three types of test articles, all of which apply the load to a 316H test section using Alloy 617 as the driver material. The three types of specimens each serve a unique purpose: (1) initial proof-of-concept, (2) validation of the models used to size the specimens to achieve a given strain range, and (3) demonstration that the articles can be miniaturized for use in an actual operating reactor. In addition to the specimen design, fabrication, and testing, this report describes the outline of two types of in-situ monitoring programs, using the test article. Monitoring programs such as these could be a critical component in gaining regulator acceptance for Molten Salt Reactor (MSR) designs using structural materials for which there is little long-term experimental environmental testing or operating experience available for calibrating the component structural design.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Size effect in stainless steel thin wires under tension

Miniaturization of modern devices drives the exploration into how materials behave in small dimensions. However, the mechanical behaviors of micro-scale specimens under varied loading conditions are still challenging to characterize and predict. In this work, specimen size-dependent weakening effect was experimentally revealed in 316L stainless steel thin wires under tension with wire diameter decreasing from 200 μm down to 61 μm. The underlying mechanisms were primarily associated with surface grain softening and strain localization, which were largely dependent on the number of grains across wire diameter. Through an analog composite model with surface and interior grains that follows the Hall-Petch relation, the extent of surface grain softening was found to coincide with the flow stress reduction due to lack of boundary strengthening. Further using elasto-plastic self-consistent polycrystal modeling, the stress-strain behaviors of interior and surface grains were well described in analogy to those of bulk materials with similar-size grains and extremely large grains, respectively. Subsequently, the analog composite model well simulated the specimen size-dependent weakening effect under tension. This article provided more insights into the size effect exploration and proposed a practical model for describing size-dependent mechanical behaviors of small-scale materials to be applied to miniaturized devices.

316L stainless steel↗

Miniature Beryllium Split-Hopkinson Pressure Bars for Extending the Range of Achievable Strain-Rates

Conventional Split Hopkinson Pressure Bars (SHPB) or “Kolsky” bars are often used for determining the high-rate compressive yield and failure strength of materials. However, for experiments generating very high strain-rates (>10 3 /s) miniaturization of the setup is often required for minimizing the effects of elastic wave dispersion in order to enable the inference of decreasingly short loading events from the data. Miniature aluminum and steel bars are often sufficient for meeting these requirements. However, for high enough strain-rates, miniaturization of steel or aluminum Kolsky bars may require prohibitively small diameter bars and test specimens that could become inappropriate for inferring representative properties of materials with large grain size relative to the test specimen size. The use of a beryllium Kolsky bar setup is expected to enable high rates to be accessible with larger diameter bars/specimen combinations due to the inherent physical properties of beryllium, which are expected to minimize the effects of elastic wave dispersion. For this reason, a series of beryllium Kolsky bars have been developed, and, in this paper, the dispersion characteristics of these bars are measured and compare the data with those of similarly sized 7075-T6 aluminum and C350 maraging steel. The results, which agree well with the theory, show no appreciable frequency dependence of the elastic wavespeed in the data from the beryllium bars, demonstrating its advantage over aluminum and steel in application to Kolsky bars.

36 MATERIALS SCIENCE↗

Radiation-induced bowing of SiC/SiC composites under neutron flux gradients—integral experimental data for model validation

Here, the radiation-induced swelling of SiC and its composites, including strong dependencies on temperature and dose, can drive significant lateral bowing in the presence of temperature and/or dose gradients. In recent years, simulations have been performed to assess the extent of bowing in SiC composite light-water reactor (LWR) fuel cladding and boiling water reactor (BWR) channel boxes. However, to date, no integral experimental data exist to validate these models. This work provides the first experimental bowing evaluation of three ∼380 mm long SiC composite specimens irradiated under varying neutron dose gradients (∼50°C–60°C, 0.03–0.06 dpa): two tubes (∼9.8 mm diameter) and a miniature BWR channel box (∼30 mm square). The measured radiation-induced length swelling (∼0.3%–0.7% linear) was consistently 10%–21% higher than values obtained from 3D finite element structural analyses with inputs from 3D radiation transport calculations. This discrepancy could be at least partially explained by differences in dose rate (∼10 -8 dpa/s) compared to the literature data (∼10-6 dpa/s) used to establish the dose-to-swelling correlations in the model. Nevertheless, the modeled bowing magnitudes (<2 mm) obtained from finite element analyses and simple analytical equations were within the bounds of the experimental measurements for all specimens. With improved confidence in the ability to predict the structural response and measure the macroscopic deformations, future experiments will target transient bowing under neutron flux gradients at representative LWR temperatures and assess whether grid spacers can mitigate the tens of millimeters of bowing that would otherwise be expected in ∼4 m long LWR components.

bowing↗