Search NASA⌕ Search

SEARCH · Search NASA

Results for “minimum-B fields”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

28 records · Page 2

Helical plasma thruster

A new scheme of plasma thruster is proposed. It is based on axial acceleration of rotating magnetized plasmas in magnetic field with helical corrugation. The idea is that the propellant ionization zone can be placed into the local magnetic well, so that initially the ions are trapped. The E × B rotation is provided by an applied radial electric field that makes the setup similar to a magnetron discharge. Then, from the rotating plasma viewpoint, the magnetic wells of the helically corrugated field look like axially moving mirror traps. Specific shaping of the corrugation can allow continuous acceleration of trapped plasma ions along the magnetic field by diamagnetic forces. The accelerated propellant is expelled through the expanding field of magnetic nozzle. By features of the acceleration principle, the helical plasma thruster may operate at high energy densities but requires a rather high axial magnetic field, which places it in the same class as the VASIMR{sup ®} rocket engine.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The electron cyclotron resonance ion source with arc-shaped coils concept (invited)

The main limitation to further improve the performance of ECR ion sources is set by the magnet technology related to the multipole magnet field used for the closed minimum-B structure. The JYFL ion source group has sought different approaches to improve the strength of the minimum-B structure required for the production of highly charged ion beams. It was found out that such a configuration can be realized with arc shaped coils. The first prototype, electron cyclotron resonance ion source with arc-shaped coils (ARC-ECRIS), was constructed and tested at JYFL in 2006. It was confirmed that such an ion source can be used for the production of highly charged ion beams. Regardless of several cost-driven compromises such as extraction mirror ratio of 1.05-1.2, microwave frequency of 6.4 GHz, and beam line with limited capacity, Ar{sup 4+} beam intensity of up to 2 {mu}A was measured. Subsequent design study has shown that the ARC-ECRIS operating at the microwave frequency above 40 GHz could be constructed. This specific design would be based on NbTi-wires and it fulfills the experimental magnetic field scaling laws. In this article, the ARC-ECRIS concept and its potential applications will be described.

43 PARTICLE ACCELERATORS↗

Propagation of shear Alvén waves in two-ion species plasmas confined by a nonuniform magnetic field

Ray tracing calculations are performed for shear Alfvén waves in two-ion species plasmas in which the magnetic field varies with position. Three different magnetic topologies of contemporary interest are explored: a linear magnetic mirror, a pure toroidal field, and a tokamak field. The wave frequency is chosen to lie in the upper propagation band, so that reflection at the ion-ion hybrid frequency can occur for waves originally propagating along the magnetic field direction. Calculations are performed for a magnetic well configuration used in recent experiments [S. T. Vincena et al., Geophys. Res. Lett. 38, L11101 (2011) and S. T. Vincena et al., Phys. Plasmas 20, 012111 (2013)] in the Large Plasma Device (LAPD) related to the ion-ion hybrid resonator. It is found that radial spreading cannot explain the relatively low values of the resonator quality factor (Q) measured in those experiments, even when finite ion temperature is considered. This identifies that a damping mechanism is present that is at least an order of magnitude larger than dissipation due to radial energy loss. Calculations are also performed for a magnetic field with pure toroidal geometry, without a poloidal field, as in experiments being planned for the Enormous Toroidal Plasma Device. In this case, the effects of field-line curvature cause radial reflections. A poloidal field is included to explore a tokamak geometry with plasma parameters expected in ITER. When ion temperature is ignored, it is found that the ion-ion hybrid resonator can exist and trap waves for multiples bounces. The effects of finite ion temperature combine with field line curvature to cause the reflection point to move towards the tritium cyclotron frequency when electron temperature is negligible. However, for ITER parameters, it is shown that the electrons must be treated in the adiabatic limit to properly describe resonator phenomena.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fusion neutron generation computations in a stellarator-mirror hybrid with neutral beam injection

In the paper [Moiseenko V.E., Noack K., Agren O. 'Stellarator-mirror based fusion driven fission reactor' J Fusion Energy 29 (2010) 65.], a version of a fusion driven system (FDS), i.e. a sub-critical fast fission assembly with a fusion plasma neutron source, is proposed. The plasma part of the reactor is based on a stellarator with a small mirror part. Hot ions with high perpendicular energy are assumed to be trapped in the magnetic mirror part. The stellarator part which connects to the mirror part and provides confinement for the bulk (deuterium) plasma. In the magnetic well of the mirror part, fusion reactions occur from collisions between a of hot ion component (tritium) with cold background plasma ions. RF heating is one option to heat the tritium. A more conventional method to sustain the hot ions is neutral beam injection (NBI), which is here studied numerically for the above-mentioned hybrid scheme. For these studies, a new kinetic code, KNBIM, has been developed. The code takes into account Coulomb collisions between the hot ions and the background plasma. The geometry of the confining magnetic field is arbitrary for the code. It is accounted for via a numerical bounce averaging procedure. Along with the kinetic calculations the neutron generation intensity and its spatial distribution are computed.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

The effect of magnetic topography on high-latitude radio emission at Neptune

Occultation by a local elevation on the surface of constant magnetic field is proposed as a new interpretation for the unusual properties of Neptune high-latitude emission. Abrupt changes in intensity and polarization of this broadband smooth radio emission were observed as the Voyager 2 spacecraft passed near the north magnetic pole before closest approach. The observed sequence of cutoffs with polarization reversal would not occur during descent of the spacecraft through regular surfaces of increasing magnetic field. The sequence can be understood in terms of constant-frequency (constant-field) surfaces that are not only offset from the planet center but are locally highly distorted by an elevation that occults the outgoing extraordinary-mode beam. The required occulter is similar to the field enhancement observed directly by the magnetometer team when Voyager reached lower altitude farther to the west. Evidence is presented that the sources of the high-altitude emission are located near the longitude of the minimum-B anomaly associated with the dipole offset and that the local elevation of constant-B surfaces extends eastward from the longitude where it is directly measured by the magnetometer to the longitude where occultation of the remote radio source is observed. Together, the radio and magnetometer experiments indicate that the constant-frequency surfaces are distorted by an elevation that extends 0.3 rad in the longitudinal direction.

Sawyer, C. B.↗

Limitations of electron cyclotron resonance ion source performances set by kinetic plasma instabilities

Electron cyclotron resonance ion source (ECRIS) plasmas are prone to kinetic instabilities due to anisotropy of the electron energy distribution function stemming from the resonant nature of the electron heating process. Electron cyclotron plasma instabilities are related to non-linear interaction between plasma waves and energetic electrons resulting to strong microwave emission and a burst of energetic electrons escaping the plasma, and explain the periodic oscillations of the extracted beam currents observed in several laboratories. It is demonstrated with a minimum-B 14 GHz ECRIS operating on helium, oxygen, and argon plasmas that kinetic instabilities restrict the parameter space available for the optimization of high charge state ion currents. The most critical parameter in terms of plasma stability is the strength of the solenoid magnetic field. It is demonstrated that due to the instabilities the optimum B{sub min}-field in single frequency heating mode is often ≤0.8B{sub ECR}, which is the value suggested by the semiempirical scaling laws guiding the design of modern ECRISs. It is argued that the effect can be attributed not only to the absolute magnitude of the magnetic field but also to the variation of the average magnetic field gradient on the resonance surface.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cyclotron instability in the afterglow mode of minimum-B ECRIS

It was shown recently that cyclotron instability in non-equilibrium plasma of a minimum-B electron cyclotron resonance ion source (ECRIS) causes perturbation of the extracted ion current and generation of strong bursts of bremsstrahlung emission, which limit the performance of the ion source. The present work is devoted to the dynamic regimes of plasma instability in ECRIS operated in pulsed mode. Instability develops in decaying plasma shortly after heating microwaves are switched off and manifests itself in the form of powerful pulses of electromagnetic emission associated with precipitation of high energy electrons. Time-resolved measurements of microwave emission bursts are presented. It was found that even in various gases (helium and oxygen were studied) and at different values of magnetic field and heating power, the dynamic spectra demonstrate common features: decreasing frequency within a single burst as well as from one burst to another.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An electron cyclotron resonance plasma configuration for increasing the efficiency in the yield of nitrogen endohedral fullerenes

Efficiently yielding a nitrogen-atom endohedral fullerene (N-C{sub 60}) is demonstrated for the first time using an electron cyclotron resonance (ECR) plasma source with a minimum-B mirror configuration realized by hexapole permanent magnets. Since electrons are effectively confined around a bottom of the minimum-B mirror in the ECR region, the high-temperature electrons can be generated there, and as a result, the dissociation degree of the nitrogen molecules increases drastically. This highly dissociated nitrogen plasma has a number of nitrogen-atom radicals and ions, thus permitting an enhancement of N-C{sub 60} yield.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Convectively stable pressure profile in magnetic confinement systems with internal rings

A convectively stable pressure profile in a long multiple-mirror (corrugated) magnetic confinement system with internal current-carrying rings is calculated. The plasma energy content in the axial region can be increased by using an internal ring that reverses the on-axis magnetic field direction and gives rise to an average magnetic well near the axis. The pressure profile in the outer region-outside the magnetic well-is considered in detail. It is shown that, in the radial pressure profile, a pedestal can be formed that leads to a higher pressure drop between the center and the plasma edge. The pressure profile is calculated from the Kruskal-Oberman criterion-a necessary and sufficient condition for the convective stability of a collisionless plasma. The revealed pedestal arises near the boundary of the average magnetic well in the region of the smallest but alternating-sign curvature of the magnetic field lines due to a break in the convectively stable pressure profile. Such a shape of the stable pressure profile can be attributed to the stabilizing effect of the alternating-sign curvature of the field lines in the multiple-mirror magnetic confinement systems under consideration.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Alternative approaches to plasma confinement

The paper discusses 20 plasma confinement schemes each representing an alternative to the tokamak fusion reactor. Attention is given to: (1) tokamak-like devices (TORMAC, Topolotron, and the Extrap concept), (2) stellarator-like devices (Torsatron and twisted-coil stellarators), (3) mirror machines (Astron and reversed-field devices, the 2XII B experiment, laser-heated solenoids, the LITE experiment, the Kaktus-Surmac concept), (4) bumpy tori (hot electron bumpy torus, toroidal minimum-B configurations), (5) electrostatically assisted confinement (electrostatically stuffed cusps and mirrors, electrostatically assisted toroidal confinement), (6) the Migma concept, and (7) wall-confined plasmas. The plasma parameters of the devices are presented and the advantages and disadvantages of each are listed.

Roth, J. R.↗