Search NASASearch

SEARCH · Search NASA

Results for “mirror assembly”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Design of a compliant passive magnetic bearing for use in SIRTF's Tertiary Mirror Assembly

A proposed baseline design for the Space Infrared Telescope Facility includes a Tertiary Mirror Assembly (TMA) which selectively redirects the telescope's converging science beam to each of several instruments. The TMA's mirror rotates on an axis coincident with the beam's axis, and is held steady during observation by a kinematic mount. A bearing has been designed whose compliance causes minimal interference with the precision of the kinematic mount, and which is well suited to the particular requirements of a cryogenic satellite such as SIRTF. The bearing suspends its rotor by taking advantage of the repulsion between a superconductor and a magnet. It potentially eliminates problems associated with mechanical bearings that arise in similar applications, such as lubricant loss or failure, bearing wear, and sensitivity to particulates, and does so without imposing the thermal load of a bearing heater or active magnetic bearing. The bearing shows promise of offering an alternative to ball bearings in cryogenic applications where some compliance is acceptable or advantageous.

Cannon, David M.

Thermal Model Development for an X-Ray Mirror Assembly

Space-based x-ray optics require stringent thermal environmental control to achieve the desired image quality. Future x-ray telescopes will employ hundreds of nearly cylindrical, thin mirror shells to maximize effective area, with each shell built from small azimuthal segment pairs for manufacturability. Thermal issues with these thin optics are inevitable because the mirrors must have a near unobstructed view of space while maintaining near uniform 20 C temperature to avoid thermal deformations. NASA Goddard has been investigating the thermal characteristics of a future x-ray telescope with an image requirement of 5 arc-seconds and only 1 arc-second focusing error allocated for thermal distortion. The telescope employs 135 effective mirror shells formed from 7320 individual mirror segments mounted in three rings of 18, 30, and 36 modules each. Thermal requirements demand a complex thermal control system and detailed thermal modeling to verify performance. This presentation introduces innovative modeling efforts used for the conceptual design of the mirror assembly and presents results demonstrating potential feasibility of the thermal requirements.

x ray optics

Contamination analyses of technology mirror assembly optical surfaces

Automated electron microprobe analyses were performed on tape lift samples from the Technology Mirror Assembly (TMA) optical surfaces. Details of the analyses are given, and the contamination of the mirror surfaces is discussed. Based on the automated analyses of the tape lifts from the TMA surfaces and the control blank, we can conclude that the particles identified on the actual samples were not a result of contamination due to the handling or sampling process itself and that the particles reflect the actual contamination on the surface of the mirror.

Germani, Mark S.

Design of a prototype secondary mirror assembly for the Space Infrared Telescope Facility

The design of a liquid helium temperature prototype secondary mirror assembly (PSMA) under development for the NASA Space Infrared Telescope Facility (SIRTF) program is described. The SIRTF assembly must operate below 4 K and provide the functions of highly precise two-axis periodic tilting ('chopping') in addition to the conventional functions of focus and collimation adjustment. The PSMA design employs a fused quartz mirror kinematically attached at its center to an aluminum cruciform. The mirror/cruciform assembly is driven in tilt about its combined center of mass using an aluminum flexure pivot of unique design and a four-actuator control system with feedback provided by pairs of differential position sensors. The voice coil actuators are mounted on a second flexure-pivoted mass to enhance servosystem stability and isolate the telescope from vibration-induced disturbances. The mirror/cruciform and reaction mass are attached to opposite sides of an aluminum mounting plate whose position relative to the outer housing is controlled by a six-degree-of-freedom focus and centering mechanism using pivoted actuation levers driven by lead screw/harmonic drive/stepper motor assemblies.

Stier, Mark T.

Cryogenic performance of the SIRTF prototype secondary mirror assembly

Results are presented of the first liquid helium temperature testing of the Space Infrared Telescope Facility (SIRTF) prototype Secondary Mirror Assembly (PSMA). Attention is given to the key requirements of PSMA, its design, and the test instrumentation and procedures. Results of preliminary tests completed to date showed that the design of the PSMA forms a very strong basis for meeting the SIRTF requirements.

Stier, M. T.

Absolute Effective Area of the Chandra High-Resolution Mirror Assembly

The Chandra X-ray Observatory was launched in July 1999, and is returning exquisite sub-arcsecond x-ray images of star groups, supernova remnants, galaxies, quasars, and clusters of galaxies. In addition to being the premier X-ray observatory in terms of angular and spectral resolution, Chandra is the best calibrated X-ray facility ever flown. We discuss here the calibration of the effective area of the High Resolution Mirror Assembly. Because we do not know the absolute X-ray flux density of any celestial source, this must be based primarily on ground measurements and on modeling. In particular, we must remove the calibrated modeled responses of the detectors and gratings to obtain the mirror area. For celestial sources which may be assumed to have smoothly varying spectra, such as the Crab Nebula, we may verify the continuity of the area calibration as a function of energy. This is of significance in energy regions such as the Ir M-edges, or near the critical grazing angle cutoff of the various mirror shells.

Schwartz, D. A.

Experimental evaluation of the ring focus test for X-ray telescopes using AXAF's technology mirror assembly, MSFC CDDF Project No. H20

A test method particularly suited for X-ray telescopes was evaluated experimentally. The method makes use of a focused ring formed by an annular aperture when using a point source at a finite distance. This would supplement measurements of the best focus image which is blurred when the test source is at a finite distance. The telescope used was the Technology Mirror Assembly of the Advanced X-ray Astrophysis Facility (AXAF) program. Observed ring image defects could be related to the azimuthal location of their sources in the telescope even though in this case the predicted sharp ring was obscured by scattering, finite source size, and residual figure errors.

Zissa, D. E.

Performance of The Far Ultraviolet Spectroscopic Explorer Mirror Assemblies

The Far Ultraviolet Spectroscopic Explorer is a NASA astrophysics satellite which produces high-resolution spectra in the far-ultraviolet (90.5-118.7 nm bandpass) using a high effective area and low background detectors. The observatory was launched on its three-year mission from Cape Canaveral Air Station on 24 June 1999. The instrument contains four coaligned, normal incidence, off-axis parabolic mirrors which illuminate separate Rowland circle spectrograph channels equipped with holographically ruled diffraction gratings and delay line microchannel plate detectors. The telescope mirrors have a 352 x 387 mm aperture and 2245 mm focal length and are attached to actuator assemblies, which provide on-orbit, tip, tilt, and focus control. Two mirrors are coated with silicon carbide (SiC) and two are coated with lithium fluoride over aluminum (Al:LiF). We describe mirror assembly in-flight optical and mechanical performance. On-orbit measurements of the far-ultraviolet point spread function associated with each mirror are compared to expectations based on pre-flight laboratory measurements and modeling using the Optical Surface Analysis Code and surface metrology data. On-orbit imaging data indicate that the mirrors meet their instrument-level requirement of 50 percent and 95 percent slit transmission for the high- and mid-resolution spectrograph entrance slits, respectively. The degradation of mirror reflectivity during satellite integration and test is also discussed. The far-ultraviolet reflectivity of the SiC- and AlLiF-coated mirrors decreased about six percent and three percent, respectively, between coating and launch. Each mirror is equipped with three actuators, which consist of a stepper motor driving a ball screw via a two-stage planetary gear train. We also discuss the mechanical performance of the mirror assemblies, including actuator performance and thermal effects.

Ohi, Raymond G.

Magnetic Interface for Segmented Mirror Assembly

Newly developed magnetic devices are used to create an interface between adjacent mirror segments so that once assembled, aligned, and phased, the multiple segments will behave functionally equivalent to a monolithic aperture mirror. One embodiment might be a kinematic interface that is reversible so that any number of segments can be pre-assembled, aligned, and phased to facilitate fabrication operations, and then disassembled and reassembled, aligned, and phased in space for operation. The interface mechanism has sufficient stiffness, force, and stability to maintain phasing. The key to producing an interface is the correlated magnetic surface. While conventional magnets are only constrained in one direction -- the direction defined by their point of contact (they are in contact and cannot get any closer) -- correlated magnets can be designed to have constraints in multiple degrees of freedom. Additionally, correlated magnetic surfaces can be designed to have a limited range of action.

Stahl, H.

Torque-while-turnaround scan mirror assembly

Mechanical aspects in the development of an oscillating scan mirror mechanism were reviewed, that featured a remarkably low level of structural vibration for the impact energies involved in mirror oscillation. Another feature was that energy lost during impact was returned to the mirror by applying torque only during the instant of impact. Because the duration of impact was only about 0.010 second, it was critical that energy losses be minimal because there was not much time to restore them.

Starkus, C. J.

Conceptual support design of the high resolution mirror assembly for the Advanced X-ray Astrophysics Facility (AXAF)

The performance goals of the Advanced X-ray Astrophysics Facility (AXAF) require that the Wolter I optics support system be insensitive to temperature fluctuations and the effects of gravity during ground testing. Previous work has shown that acceptable concepts are achievable but require much attention to design details. This paper discusses a new support system wherein each optic is held by a single circumfererential ring near its center of mass rather than a multipoint support as previously analyzed. The thermal sensitivity of this system is considerably lower than any concept yet studied. This advanced support concept allows the use of a wider variety of mateials and simple design details. Structural analysis utilizing the finite element method and optical ray-trace analysis are used to predict the system performance.

Cohen, L. M.

The effects of epoxy shrinkage on the Advanced X-ray Astrophysics Facility Technology Mirror Assembly

A method is shown analytically which reduces the effects of epoxy shrinkage for an ultra-high precision X-ray telescope to within the system error budget. The three-dimensional shrinkage effects are discussed with reference to this telescope. The results of the analysis point to the use of an interrupted rather than continuous bond line as the best solution. Discussion of the finite element modelling techniques is included.

Cohen, L. M.

Opto-Mechanics of the Constellation-X SXT Mirrors: Challenges in Mounting and Assembling the Mirror Segments

The Constellation-X Spectroscopy X-Ray Telescopes consists of segmented glass mirrors with an axial length of 200 mm, a width of up to 400 mm, and a thickness of 0.4 mm. To meet the requirement of less than 15 arc-second half-power diameter with the small thickness and relatively large size is a tremendous challenge in opto-mechanics. How shall we limit distortion of the mirrors due to gravity in ground tests, that arises from thermal stress, and that occurs in the process of mounting, affixing and assembling of these mirrors? In this paper, we will describe our current opto-mechanical approach to these problems. We will discuss, in particular, the approach and experiment where the mirrors are mounted vertically by first suspending it at two points.

Chan, Kai-Wing

NASA James Webb Space Telescope Engineering of the Primary Mirror Segment Assemblies (PMSA) and the Primary Mirror Backplane Support Structure (PMBSS)

The design, engineering tests of the PMSAs PMBSS show that we have a robust system that not only meets but exceeds (better than) the design requirements for these components. In the next 2 years the Telescope Observatory will be subjected to a simulated launch environment (sine vibeacoustics) and operations tests at cryogenic temperatures. Launch is schedule for the last quarter of 2018.

PMBSS

James Webb Space Telescope Primary and Secondary Mirror Segment Assemblies Cleaning: a Quantitative Assessment

The James Webb Space Telescope Primary Mirror Segment Assemblies (PMSAs) and Secondary Mirror Assembly (SMA) were cleaned at the Johnson Space Center (JSC) in January 2018. In order to quantify the effectiveness of the cleaning, the same cleaning process was performed on the PMSA and SMA traveling witness wafers. These wafers have accompanied their respective mirror segments from their arrival at the Goddard Space Flight Center, through transport to JSC, and ultimately their exposure in Chamber A for cryogenic testing. The traveling wafers were analyzed using an Image Analysis automated microscope both prior to and after the cleaning. The resulting data showed that the PMSA wafers' Percent Area Coverage (PAC) reduced by 83.5% on average, from 0.1524 PAC to 0.0251 PAC. The SMA wafer's PAC decreased by 97.2%, from 0.1194 PAC to 0.0034 PAC. Further analysis of the particle size bins was completed in order to calculate their particle distribution slopes. The slope of the PMSA wafers increased by 0.025 on average, and the SMA wafer slope increased by 0.066. This indicates that the ratio of large to small particles slightly increased after the cleaning across all mirror segments. Visual inspections of the wafers and the flight PMSAs and SMA showed considerable and comparable particulate coverage improvements, thus leading to the conclusion that the average PAC on the PMSAs and SMA improved by the same factor as their respective wafers.

mirror

Point Relay Scanner Utilizing Ellipsoidal Mirrors

A scanning system uses a polygonal mirror assembly with each facet of the polygon having an ellipsoidal mirror located thereon. One focal point of each ellipsoidal mirror is located at a common point on the axis of rotation of the polygonal mirror assembly. As the mirror assembly rotates. a second focal point of the ellipsoidal mirrors traces out a scan line. The scanner can be utilized for scanned output display of information or for scanning information to be detected.

Manhart, Paul K.