Search NASA⌕ Search

SEARCH · Search NASA

Results for “mixed binding”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

35 records · Page 2

Human serum albumin crystals and method of preparation

Human serum albumin (HSA) crystals are provided in the form of tetragonal plates having the space groups P42(sub 1)2, the crystals being grown to sizes in excess of 0.5 mm in two dimensions and a thickness of 0.1 mm. Growth of the crystals is carried out by a hanging drop method wherein a precipitant solution containing polyethylene glycol (PEG) and a phosphate buffer is mixed with an HSA solution, and a droplet of mixed solution is suspended over a well of precipitant solution. Crystals grow to the desired size in 3 to 7 days. Concentration of reagents, pH and other parameters are controlled within prescribed limits. The resulting crystals exhibit a size and quality such as to allow performance of x ray diffraction studies and enable the conduct of drug binding studies as well as genetic engineering studies.

Carter, Daniel C.↗

Physics of Biocrystals and Their Growth

Recent results on binding between protein molecules in crystal lattice, crystal-solution surface energy, elastic properties and strength and spontaneous crystal cracking are reviewed and discussed in the first half of the paper (Sections 2-5). In the second part, some basic approaches to solubility of proteins is followed by overview on crystal nucleation and growth (Section 6). It is argued that variability of mixing in batch crystallization may be a source scattering of crystal number ultimately appearing in the batch (Section 7). Frequency at which new molecules join crystal lattice is related to the observable crystal growth rate. Numerical criteria to discriminate diffusion and kinetic limited growth are discussed on this basis in Section 8. In Section 9, creation of defects is discussed with the emphasis on the role of impurities and convection in macromolecular crystal perfection.

Chernov, A.↗

Protein Crystals and their Growth

Recent results on binding between protein molecules in crystal lattice, crystal-solution surface energy, elastic properties and strength and spontaneous crystal cracking are reviewed and discussed in the first half of this paper (Sea 2-4). In the second par&, some basic approaches to solubility of proteins are followed by overview on crystal nucleation and growth (Sec 5). It is argued that variability of mixing in batch crystallization may be a source for scattering of crystal number ultimately appearing in the batch. Frequency at which new molecules join crystal lattice is measured by kinetic coefficient and related to the observable crystal growth rate. Numerical criteria to discriminate diffusion and kinetic limited growth are discussed on this basis in Sec 7. In Sec 8, creation of defects is discussed with the emphasis on the role of impurities and convection on macromolecular crystal I;erfection.

Chernov, A. A.↗

Automated Fluidics Device for Extraction and Quantification of miRNA Biomarkers From Blood

Radiation Assessment DuRing Exposure And long-Duration Spaceflight (RADREADS) demonstrates space-compatible point-of-care technology for quantitative biological monitoring of blood miRNA biomarkers in response to long-term low dose radiation exposure. This individualized monitoring approach will inform targeted treatment strategies to maximize medical resource utilization by accounting for individual susceptibility to radiation-related illnesses. As human spaceflight progresses beyond Earth’s magnetic shielding, radiation exposure poses a significant risk to astronaut health and safety. Extended operation in this environment comes with an increased risk of radiation exposure, leading to higher risks of radiation sickness, cancer, central nervous system effects, and degenerative diseases. While conventional physical dosimetry techniques capture radiation dose, individualistic susceptibility to radiation damage is varied. Multiple characteristics, including age, body weight, sex, genetics, and immune status, have been found to influence radiosensitivity (Liu et al. 2011, and Bouffler 2016). This differential response necessitates individualized monitoring and targeted treatment strategies to maximize medical resource utilization; however, a practical diagnostic platform for quantifying long-term, low dose radiation-induced tissue damage does not currently exist. MicroRNAs (miRNAs) are a class of small, non-coding RNAs that regulate gene expression by mediating the degradation of messenger RNA. The levels of particular miRNAs are influenced by biological processes such as inflammation and serve as biomarkers for a variety of conditions including cancer (Singh et al. 2017). MicroRNAs are found in various bodily fluids and are amenable to collection via liquid biopsies, providing a minimally invasive and easily quantifiable readout for a variety of radiosensitive reporters. A preliminary signature of 15 spaceflight sensitive miRNA has been identified in rodent and human studies, including miR-21-5p, miR-24-3p, miR-92a-3p, miR-17-5p, miR-16a-3p, miR-34a-3p, and miR-223-3p. These targets generally increased expression with radiation dose and linear energy transfer, though variation between individuals is not yet described. Current gaps in the field include a lack of understanding of longitudinal biological responses to long-term, low dose radiation exposure and the absence of space-compatible point-of-care technology for quantitative biological monitoring. In this body of work, we aim to develop an automated bleed-to-read system to process whole blood for the detection of miRNA biomarkers in order to monitor individualistic responses to radiation exposure. This will be achieved via separating serum (or plasma) from whole blood, followed by extraction, amplification, and quantification of the miRNA using a RT-qPCR reaction. Previously, the WetLab-2 hardware enabled execution of a RT-qPCR reaction aboard ISS; however, it is a manual system that requires crew manipulation and bulky components (Parra et al. 2017). To address these issues, automated fluid handling hardware was developed for each stage of sample preparation. Extraction of total RNA is achieved by sequentially pumping reagents through an off-the-shelf nucleic acid binding column (miRNeasy Serum/Plasma Advanced Kit, Qiagen). This approach eliminates several manual pipetting and centrifuging steps and limits the use of toxic chemicals commonly found in other sample processing techniques. The resulting elution will then be automatically dispensed for RT-qPCR analysis using a compact rotary qPCR (Mic qPCR Cycler, Bio Molecular Systems) that will improve spaceflight compatibility by removing bubbles from the detection region, another challenge highlighted by WetLab-2 (Parra et al. 2017). Efforts are also being made to simplify the RT-qPCR reaction to a 1-step air-dryable mix to improve long-term reagent stability at room temperature and reduce system complexity. By automating the RT-qPCR processes via microfluidic manipulation, RADREADS will reduce crewmember hands-on time and enable the personalized detection of radiation-induced tissue damage during long duration missions. Minimally invasive, longitudinal monitoring of individual’s response to radiation exposure will inform how the physiological system responds to long-term low dose space radiation and enables development of targeted countermeasures by the medical team. Ultimately, this portable technology will require minimal technical expertise and can also be used to monitor miRNA biomarkers associated with other diseases.

Tristen Head↗

FRET-Aptamer Assays for Bone Marker Assessment, C-Telopeptide, Creatinine, and Vitamin D

Astronauts lose 1.0 to 1.5% of their bone mass per month on long-duration spaceflights. NASA wishes to monitor the bone loss onboard spacecraft to develop nutritional and exercise countermeasures, and make adjustments during long space missions. On Earth, the same technology could be used to monitor osteoporosis and its therapy. Aptamers bind to targets against which they are developed, much like antibodies. However, aptamers do not require animal hosts or cell culture and are therefore easier, faster, and less expensive to produce. In addition, aptamers sometimes exhibit greater affinity and specificity vs. comparable antibodies. In this work, fluorescent dyes and quenchers were added to the aptamers to enable pushbutton, one-step, bind-and-detect fluorescence resonance energy transfer (FRET) assays or tests that can be freeze-dried, rehydrated with body fluids, and used to quantitate bone loss of vitamin D levels with a handheld fluorometer in the spacecraft environment. This work generated specific, rapid, one-step FRET assays for the bone loss marker C-telopeptide (CTx) when extracted from urine, creatinine from urine, and vitamin D congeners in diluted serum. The assays were quantified in nanograms/mL using a handheld fluorometer connected to a laptop computer to convert the raw fluorescence values into concentrations of each analyte according to linear standard curves. DNA aptamers were selected and amplified for several rounds against a 26- amino acid form of CTx, creatinine, and vitamin D. The commonalities between loop structures were studied, and several common loop structures were converted into aptamer beacons with a fluorophore and quencher on each end. In theory, when the aptamer beacon binds its cognate target (CTx bone peptide, creatinine, or vitamin D), it is forced open and no longer quenched, so it gives off fluorescent light (when excited) in proportion to the amount of target present in a sample. This proportional increase in fluorescence is called a "lights on" FRET response. The vitamin D aptamer beacon gives a "lights off" or inversely proportional fluorescence response to the amount of vitamin D present in diluted serum. These FRET-aptamer assays are rapid (<30 minutes), sensitive (low ng/mL detection limits), and quite easy to carry out (add sample, mix, and detect in the handheld reader). Benefits include the speed of the assays as well as the small amount of space taken up by the handheld reader and cuvette assays. The aptamer DNA sequences represent novel additional features of the existing (patent-pending) FRET-aptamer assay platform.

Bruno, John G.↗

Phylogenetic perspective and the search for life on earth and elsewhere

Any search for microbial life on Mars cannot rely upon cultivation of indigenous organisms. Only a minority of even terrestrial organisms that are observed in mixed, naturally-occurring microbial populations can be cultivated in the laboratory. Consequently, methods are being developed for analyzing the phylogenetic affiliations of the constituents of natural microbial populations without the need for their cultivation. This is more than an exercise in taxonomy, for the extent of phylogenetic relatedness between unknown and known organisms is some measure of the extent of their biochemical commonalities. In one approach, total DNA is isolated from natural microbial populations and 16S rRNA genes are shotgun cloned for rapid sequence determinations and phylogenetic analyses. A second approach employs oligodeoxynucleotide hybridization probes that bind to phylogenetic group-specific sequences in 16S rRNA. Since each actively growing cell contains about 104 ribosomes, the binding of the diagnostic probes to single cells can be visualized by radioactivity or fluorescence. The application of these methods and the use of in situ cultivation techniques is illustrated using submarine hydrothermal vent communities. Recommendations are made regarding planning toward future Mars missions.

Pace, Norman R.↗

The physical and infrared spectral properties of CO2 in astrophysical ice analogs

Results of measurements of the infrared spectroscopic and condensation-vaporization properties of CO2 in pure and mixed ices are presented. Detailed examination of five infrared CO2 bands, 2.20, 2.78, 4.27, 15.2, and 4.39 microns, shows that the peak position, FWHM, and profile of the bands provide important information about the composition, formation, and subsequent thermal history of the ices. Absorption coefficients and their temperature dependence for all five CO2 bands are determined. The temperature dependence variation is found to be less than 15 percent from 10 to 150 K, i.e., the temperature at which H2O ice sublimes. The number of parameters associated with the physical behavior of CO2 in CO2- and H2O-rich ices, including surface binding energies, and condensation and sublimation temperatures, are determined under experimental conditions. The implications of the data obtained for cometary models are considered.

Sandford, S. A.↗

Application of a mixed metal oxide catalyst to a metallic substrate

A method for applying a mixed metal oxide catalyst to a metallic substrate for the creation of a robust, high temperature catalyst system for use in decomposing propellants, particularly hydrogen peroxide propellants, for use in propulsion systems. The method begins by forming a prepared substrate material consisting of a metallic inner substrate and a bound layer of a noble metal intermediate. Alternatively, a bound ceramic coating, or frit, may be introduced between the metallic inner substrate and noble metal intermediate when the metallic substrate is oxidation resistant. A high-activity catalyst slurry is applied to the surface of the prepared substrate and dried to remove the organic solvent. The catalyst layer is then heat treated to bind the catalyst layer to the surface. The bound catalyst layer is then activated using an activation treatment and calcinations to form the high-activity catalyst system.

Sevener, Kathleen M.↗

The adsorption and reaction of adenine nucleotides on montmorillonite

The binding of AMP to Zn(2+)-montmorillonite is investigated in the presence of salts and Good's zwitterion buffers, PIPES and MES. The initial concentrations of nucleotide and the percent adsorbtion are used to calculate the adsorption isotherms, and the Langmuir adsorption equation is used for the analysis of data. The adsorption coefficient was found to be three times greater in the presence of 0.2 M PIPES than in its absence. In addition, basal spacings measured by X-ray diffraction were increased by the buffer. These results are interpreted in terms of a model in which the adsorption of AMP is mediated by a Zn(2+) complex of PIPES in different orientations in the interlamellar region of the montmorillonite. Mixed ligand complexes of this type are reminiscent of the complexes observed between metal ions and biological molecules in living systems.

Ferris, James P.↗

Detection of Only Viable Bacterial Spores Using a Live/Dead Indicator in Mixed Populations

This method uses a photoaffinity label that recognizes DNA and can be used to distinguish populations of bacterial cells from bacterial spores without the use of heat shocking during conventional culture, and live from dead bacterial spores using molecular-based methods. Biological validation of commercial sterility using traditional and alternative technologies remains challenging. Recovery of viable spores is cumbersome, as the process requires substantial incubation time, and the extended time to results limits the ability to quickly evaluate the efficacy of existing technologies. Nucleic acid amplification approaches such as PCR (polymerase chain reaction) have shown promise for improving time to detection for a wide range of applications. Recent real-time PCR methods are particularly promising, as these methods can be made at least semi-quantitative by correspondence to a standard curve. Nonetheless, PCR-based methods are rarely used for process validation, largely because the DNA from dead bacterial cells is highly stable and hence, DNA-based amplification methods fail to discriminate between live and inactivated microorganisms. Currently, no published method has been shown to effectively distinguish between live and dead bacterial spores. This technology uses a DNA binding photoaffinity label that can be used to distinguish between live and dead bacterial spores with detection limits ranging from 109 to 102 spores/mL. An environmental sample suspected of containing a mixture of live and dead vegetative cells and bacterial endospores is treated with a photoaffinity label. This step will eliminate any vegetative cells (live or dead) and dead endospores present in the sample. To further determine the bacterial spore viability, DNA is extracted from the spores and total population is quantified by real-time PCR. The current NASA standard assay takes 72 hours for results. Part of this procedure requires a heat shock step at 80 degC for 15 minutes before the sample can be plated. Using a photoaffinity label would remove this step from the current assay as the label readily penetrates both live and dead bacterial cells. Secondly, the photoaffinity label can only penetrate dead bacterial spores, leaving behind the viable spore population. This would allow for rapid bacterial spore detection in a matter of hours compared to the several days that it takes for the NASA standard assay.

Behar, Alberto E.↗

Automated, Miniaturized Instrument for Measuring Gene Expression in Space

To facilitate astrobiological studies on the survival and adaptation of microorganisms and mixed microbial cultures to space environment, we have been developing a fully automated, miniaturized system for measuring their gene expression on small spacecraft. This low-cost, multi-purpose instrument represents a major scientific and technological advancement in our ability to study the impact of the space environment on biological systems by providing data on cellular metabolism and regulation orders of magnitude richer than what is currently available. The system supports growth of the organism, lyse it to release the expressed RNA, label the RNA, read the expression levels of a large number of genes by microarray analysis of labeled RNA and transmit the measurements to Earth. To measure gene expression we use microarray technology developed by CombiMatrix, which is based on electrochemical reactions on arrays of electrodes on a semiconductor substrate. Since the electrical integrity of the microarray remains intact after probe synthesis, the circuitry can be employed to sense nucleic acid binding at each electrode. CombiMatrix arrays can be sectored to allow multiple samples per chip. In addition, a single array can be used for several assays. The array has been integrated into an automated microfluidic cartridge that uses flexible reagent blisters and pinch pumping to move liquid reagents between chambers. The proposed instrument will help to understand adaptation of terrestrial life to conditions beyond the planet of origin, identify deleterious effects of the space environment, develop effective countermeasures against these effects, and test our ability to sustain and grow in space organisms that can be used for life support and in situ resource utilization during long-duration space exploration. The instrument is suitable for small satellite platforms, which provide frequent, low cost access to space. It can be also used on any other platform in space, including the ISS. It can be replicated and used with only small modifications in multiple biological experiments with a broad range of goals in mind.

Pohorille, A.↗

Emissions Relationships Among Western Forest Fire Plumes: II. Plume Typing for Sources of Ozone and Aerosol Absorption

Previous studies of emission factors from biomass burning are prone to largeerrors since they ignore the interplay of mixing and varying pre-fire backgroundCO2 levels. Such complications severely affected our studies of 446 forest fireplume samples measured in the Western US by the science teams of NASAs SEAC4RS and ARCTAS airborne missions. Consequently we propose a MixedEffects Regression Emission Technique (MERET) to check techniques like theNormalized Emission Ratio Method (NERM), where use of sequentialobservations cannot disentangle emissions and mixing. We also evaluate asimpler consensus technique. All techniques relate emissions to fuel burnedusing Cburn Ctot added to the fire plume, where Ctot (CO2 + CO). Mixed-effectsregression can estimate pre-fire background values of Ctot (indexed byobservation j) simultaneously with emissions factors indexed by individualspecies i, xi (Cburn )i,j., MERET and consensus require more than twoemissions indicators. Our studies excluded samples where exogenous CO orCH4 might have been fed into a fire plume, mimicking emission.We sought to let the data on 13 gases and particulate properties suggest clustersof variables and plume types, using non-negative matrix factorization (NMF).While samples were mixtures, the NMF unmixing suggested purer burn types.Particulate properties (bscat, babs, SSA, AE) and gas-phase emissions were interrelated.Finally, we sought a simple categorization useful for modeling ozone productionin plumes. Two kinds of fires produced high ozone: those with large fuel nitrogenas evidenced by remnant CH3CN in the plumes, and also those from veryintense large burns. Fire types with optimal ratios of delta-NOydelta-HCHO associate with the highest additional ozone per unit Cburn, Perhaps theseplumes exhibit limited NOx binding to reactive organics. Perhaps these plumesexhibit limited NOx binding to reactive organics.

ozone↗

Emissions Relationships Among Western Forest Fire Plumes: I. Emission Factors Free from Mixing Errors

Previous studies of emission factors from biomass burning are prone to largeerrors since they ignore the interplay of mixing and varying pre-fire backgroundCO2 levels. Such complications severely affected our studies of 446 forest fireplume samples measured in the Western US by the science teams of NASAsSEAC4RS and ARCTAS airborne missions. Consequently we propose a MixedEffects Regression Emission Technique (MERET) to check techniques like theNormalized Emission Ratio Method (NERM), where use of sequentialobservations cannot disentangle emissions and mixing. We also evaluate asimpler consensus technique. All techniques relate emissions to fuel burnedusing C burn = Δ Ctot added to the fire plume, where ≈ Ctot (CO2 + CO). Mixed-effectsregression can estimate pre-fire background values of Ctot (indexed byobservation j) simultaneously with emissions factors indexed by individual species i, δέλτα-xi (Cburn )i,j., MERET and consensus require more than twoemissions indicators. Our studies excluded samples where exogenous CO orCH4 might have been fed into a fire plume, mimicking emission.We sought to let the data on 13 gases and particulate properties suggest clustersof variables and plume types, using non-negative matrix factorization (NMF).While samples were mixtures, the NMF unmixing suggested purer burn types.Particulate properties (bscat, babs, SSA, AÅE) and gas-phase emissions were interrelated.Finally, we sought a simple categorization useful for modeling ozone productionin plumes. Two kinds of fires produced high ozone: those with large fuel nitrogenas evidenced by remnant CH3CN in the plumes, and also those from veryintense large burns. Fire types with optimal ratios of delta-NOydelta-HCHO associate with the highest additional ozone per unit Cburn, Perhaps theseplumes exhibit limited NOx binding to reactive organics. Perhaps these plumesexhibit limited NOx binding to reactive organics.

plumes↗

Techniques for Estimating Emissions Factors from Forest Burning: ARCTAS and SEAC4RS Airborne Measurements Indicate Which Fires Produce Ozone

Previous studies of emission factors from biomass burning are prone to large errors since they ignore the interplay of mixing and varying pre-fire background CO2 levels. Such complications severely affected our studies of 446 forest fire plume samples measured in the Western US by the science teams of NASA's SEAC4RS and ARCTAS airborne missions. Consequently we propose a Mixed Effects Regression Emission Technique (MERET) to check techniques like the Normalized Emission Ratio Method (NERM), where use of sequential observations cannot disentangle emissions and mixing. We also evaluate a simpler "consensus" technique. All techniques relate emissions to fuel burned using C(sub burn) = delta C(sub tot) added to the fire plume, where C(sub tot) approximately equals (CO2 + CO). Mixed-effects regression can estimate pre-fire background values of Ctot (indexed by observation j) simultaneously with emissions factors indexed by individual species i, delta epsilon lambda tau alpha−x(sub i)/(C(sub burn))i,j., MERET and "consensus" require more than two emissions indicators. Our studies excluded samples where exogenous CO or CH4 might have been fed into a fire plume, mimicking emission. We sought to let the data on 13 gases and particulate properties suggest clusters of variables and plume types, using non-negative matrix factorization (NMF). While samples were mixtures, the NMF unmixing suggested purer burn types. Particulate properties (bscat, babs, SSA, AAE) and gas-phase emissions were interrelated. Finally, we sought a simple categorization useful for modeling ozone production in plumes. Two kinds of fires produced high ozone: those with large fuel nitrogen as evidenced by remnant CH3CN in the plumes, and also those from very intense large burns. Fire types with optimal ratios of delta-NOy/delta- HCHO associate with the highest additional ozone per unit Cburn, Perhaps these plumes exhibit limited NOx binding to reactive organics. Perhaps these plumes exhibit limited NOx binding to reactive organics.

fires↗

Techniques for Estimating Emissions Factors from Forest Burning: ARCTAS and SEAC4RS Airborne Measurements Indicate which Fires Produce Ozone

Previous studies of emission factors from biomass burning are prone to large errors since they ignore the interplay of mixing and varying pre-fire background CO2 levels. Such complications severely affected our studies of 446 forest fire plume samples measured in the Western US by the science teams of NASA's SEAC4RS and ARCTAS airborne missions. Consequently we propose a Mixed Effects Regression Emission Technique (MERET) to check techniques like the Normalized Emission Ratio Method (NERM), where use of sequential observations cannot disentangle emissions and mixing. We also evaluate a simpler "consensus" technique. All techniques relate emissions to fuel burned using C(burn) = delta C(tot) added to the fire plume, where C(tot) approximately equals (CO2 = CO). Mixed-effects regression can estimate pre-fire background values of C(tot) (indexed by observation j) simultaneously with emissions factors indexed by individual species i, delta, epsilon lambda tau alpha-x(sub I)/C(sub burn))I,j. MERET and "consensus" require more than emissions indicators. Our studies excluded samples where exogenous CO or CH4 might have been fed into a fire plume, mimicking emission. We sought to let the data on 13 gases and particulate properties suggest clusters of variables and plume types, using non-negative matrix factorization (NMF). While samples were mixtures, the NMF unmixing suggested purer burn types. Particulate properties (b scant, b abs, SSA, AAE) and gas-phase emissions were interrelated. Finally, we sought a simple categorization useful for modeling ozone production in plumes. Two kinds of fires produced high ozone: those with large fuel nitrogen as evidenced by remnant CH3CN in the plumes, and also those from very intense large burns. Fire types with optimal ratios of delta-NOy/delta- HCHO associate with the highest additional ozone per unit Cburn, Perhaps these plumes exhibit limited NOx binding to reactive organics. Perhaps these plumes exhibit limited NOx binding to reactive organics

ozone↗

NASA Tech Briefs, August 2012

Topics covered include: Mars Science Laboratory Drill; Ultra-Compact Motor Controller; A Reversible Thermally Driven Pump for Use in a Sub-Kelvin Magnetic Refrigerator; Shape Memory Composite Hybrid Hinge; Binding Causes of Printed Wiring Assemblies with Card-Loks; Coring Sample Acquisition Tool; Joining and Assembly of Bulk Metallic Glass Composites Through Capacitive Discharge; 670-GHz Schottky Diode-Based Subharmonic Mixer with CPW Circuits and 70-GHz IF; Self-Nulling Lock-in Detection Electronics for Capacitance Probe Electrometer; Discontinuous Mode Power Supply; Optimal Dynamic Sub-Threshold Technique for Extreme Low Power Consumption for VLSI; Hardware for Accelerating N-Modular Redundant Systems for High-Reliability Computing; Blocking Filters with Enhanced Throughput for X-Ray Microcalorimetry; High-Thermal-Conductivity Fabrics; Imidazolium-Based Polymeric Materials as Alkaline Anion-Exchange Fuel Cell Membranes; Electrospun Nanofiber Coating of Fiber Materials: A Composite Toughening Approach; Experimental Modeling of Sterilization Effects for Atmospheric Entry Heating on Microorganisms; Saliva Preservative for Diagnostic Purposes; Hands-Free Transcranial Color Doppler Probe; Aerosol and Surface Parameter Retrievals for a Multi-Angle, Multiband Spectrometer LogScope; TraceContract; AIRS Maps from Space Processing Software; POSTMAN: Point of Sail Tacking for Maritime Autonomous Navigation; Space Operations Learning Center; OVERSMART Reporting Tool for Flow Computations Over Large Grid Systems; Large Eddy Simulation (LES) of Particle-Laden Temporal Mixing Layers; Projection of Stabilized Aerial Imagery Onto Digital Elevation Maps for Geo-Rectified and Jitter-Free Viewing; Iterative Transform Phase Diversity: An Image-Based Object and Wavefront Recovery; 3D Drop Size Distribution Extrapolation Algorithm Using a Single Disdrometer; Social Networking Adapted for Distributed Scientific Collaboration; General Methodology for Designing Spacecraft Trajectories; Hemispherical Field-of-View Above-Water Surface Imager for Submarines; and Quantum-Well Infrared Photodetector (QWIP) Focal Plane Assembly.

Source record↗

Computational Modeling to Limit the Impact Displays and Indicator Lights Have on Habitable Volume Operational Lighting Constraints

NASA has demonstrated an interest in improving astronaut health and performance through the installment of a new lighting countermeasure on the International Space Station. The Solid State Lighting Assembly (SSLA) system is designed to positively influence astronaut health by providing a daily change to light spectrum to improve circadian entrainment. Unfortunately, existing NASA standards and requirements define ambient light level requirements for crew sleep and other tasks, yet the number of light-emitting diode (LED) indicators and displays within a habitable volume is currently uncontrolled. Because each of these light sources has its own unique spectral properties, the additive lighting environment ends up becoming something different from what was planned or researched. Restricting the use of displays and indicators is not a solution because these systems provide beneficial feedback to the crew. The research team for this grant used computer-based computational modeling and real-world lighting mockups to document the impact that light sources other than the ambient lighting system contribute to the ambient spectral lighting environment. In particular, the team was focused on understanding the impacts of long-term tasks located in front of avionics or computer displays. The team also wanted to understand options for mitigating the changes to the ambient light spectrum in the interest of maintaining the performance of a lighting countermeasure. The project utilized a variety of physical and computer-based simulations to determine direct relationships between system implementation and light spectrum. Using real-world data, computer models were built in the commercially available optics analysis software Zemax Optics Studio(c). The team also built a mockup test facility that had the same volume and configuration as one of the Zemax models. The team collected over 1200 spectral irradiance measurements, each representing a different configuration of the mockup. Analysis of the data showed a measurable impact on ambient light spectrum. This data showed that obvious design techniques exist that can be used to bind the ambient light spectrum closer to the planned spectral operating environment for the observer's eye point. The following observations should be considered when designing an operational environment that is dominated by computer displays. When more light is directed into the field of view of the observer, the greater the impact it will make on various human factors issues that depend on spectral shape and intensity. Because viewing angle has a large part to play in the amount of light flux on the crewmember's retina, beam shape, combined with light source location is an important factor for determining percent probable incident flux on the observer from any combination of light sources. Computer graphics design and display lumen output are major factors influencing the amount of spectrally intense light projected into the environment and in the viewer's direction. Use of adjustable white point display software was useful only if the predominant background color was white and if it matched the ambient light system's color. Display graphics that used a predominantly black background had the least influence on unplanned spectral energy projected into the environment. Percent reflectance makes a difference in total energy reflected back into an environment, and within certain architectural geometries, reflectance can be used to control the amount of a light spectrum that is allowed to perpetuate in the environment. Data showed that room volume and distance from significant light sources influence the total spectrum in a room. Smaller environments had a homogenizing effect on total light spectrum, whereas light from multiple sources in larger environments was less mixed. The findings indicated above should be considered when making recommendations for practice or standards for architectural systems. The ambient lighting system, surface reflectance, and display and indicator implementation all factor into the users' spectral environment. A variety of low-cost solutions exist to mitigate the impact of light from non-architectural lighting systems, and much potential for system automation and integration of display systems with the ambient environment. This team believes that proper planning can be used to avoid integration problems and also believes that human-in-the-loop evaluations, real-world test and measurement, and computer modeling can be used to determine how changes to a process, display graphics, and architecture will help maintain the planned spectral operating lighting environment.

Clark, T. A.↗