Search NASA⌕ Search

SEARCH · Search NASA

Results for “module cooling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Row spacing as a controller of solar module temperature and power output in solar farms

We report that when the temperature of solar photovoltaic modules rises, efficiency drops and module degradation accelerates. The spatial arrangement of solar modules can affect convective cooling and, consequently, module temperatures. However, the impact of row spacing on convective cooling in realistic solar farms has not yet been studied. Here, we develop six solar farm arrangements consisting of a fixed number of rows with varying streamwise row spacing. We model the flow and heat transfer of each solar farm using high-resolution large-eddy simulations. Results indicate that increasing row spacing can enhance convective cooling by 14.8%, which reduces module temperature by 6.6 °C and increases power output by 4.0% on average.

14 SOLAR ENERGY↗

Comparative Analysis of Direct and Indirect Cooling of Wide-Bandgap Power Modules and Performance Enhancement of Jet Impingement-Based Direct Substrate Cooling

With the development of high-power and high-torque machines, requirements for high-power density electronics are increasing. Thermal management of such systems requires high heat extraction. Conventional air cooling based heat sinks and cold plate based liquid cooling have their own benefits for various applications but has limitations for high power density applications. The current study explores a jet impingement based direct substrate cooling system that was implemented for a SiC based direct bonded Cu substrate for various power losses. Numerical comparison between jet impingement cooling and conventional horizontal/indirect cooling (pin fin heat sink and genetic algorithm-optimized heat sink) showed that the area weighted average of the heat transfer coefficient (HTC) is high for both horizontal cooling designs, and the local HTC is higher for jet impingement. Design iterations were undertaken to resolve the bottleneck of this cooling system. Increasing the number of nozzles helped to cover more area at the direct bonded Cu bottom plate, which drops the chip temperature considerably. With a constant flow rate, increasing the number of nozzles would decrease local jet velocity, which reduces the heat extraction by jet impingement. This issue can be addressed by reducing the diameter of nozzle but doing so results in a high pressure drop where the design constraint is 2 psi. A flared nozzle design is proposed, which has a higher spreading angle of the jet that increases the flow coverage and reduces the pressure drop of the coolant loop.

Barua, Himel↗

Thermal Studies of CMS High-Granularity Calorimeter (HGCAL) Cassettes for the HL-LHC Upgrade

The CMS High Granularity Calorimeter (HGCAL) is a key endcap upgrade for the High-Luminosity LHC, designed to operate in an environment of extreme radiation and high particle rates. Each HGCAL cassette integrates silicon and scintillator modules, front-end ASICs, and a copper cooling plate that provides both mechanical integrity and thermal coupling using two-phase CO₂ cooling. Stable and uniform temperature control is essential to ensure reliable performance of the front-end electronics and to limit radiation-induced leakage currents in the silicon sensors. We present results from thermal characterization studies of pre-series HGCAL cassettes assembled and tested at Fermilab. Embedded RTD/PT1000 temperature sensors were used to measure gradients across copper cooling plates, module layers, and cassette edges under powering conditions representative of operation. The measured thermal behavior demonstrates effective heat transport through the cassette stack and highlights small but systematic variations correlated with geometry and assembly tolerances. These results validate the cooling performance of HGCAL cassettes.

Wang, Jinglu [Northwestern U.]↗

A Comprehensive Numerical and Experimental Study for the Passive Thermal Management in Battery Modules and Packs

Cooling plates in battery packs of electric vehicles play critical roles in passive thermal management systems to reduce risks of catastrophic thermal runaway. In this work, a series of numerical simulations and experiments are carried out to unveil the role of cooling plates (both between cells and a bottom plate parallel to the cell stack) on the thermal behavior of battery modules and packs under nail penetrations. First, we investigated the role of side cooling plates on the thermal runaway propagation mitigation in battery modules (1S3P) and packs (3S3P) by varying the key parameters of the side cooling plates, such as plate thicknesses, thermal contact resistances, and materials. Then, three important factors for passive thermal management systems are identified: (i) thermal mass of side cooling plates, (ii) interfacial thermal contact resistances, and (iii) the effective heat transfer coefficients at exterior surfaces. The roles of bottom cooling plates on thermal runaway propagation mitigation in 1S3P and 1S5P battery modules are numerically investigated by comparing the thermal behavior of the modules with only side cooling plates and with both side and bottom cooling plates.

25 ENERGY STORAGE↗

Design and Analysis of an Integrated Additively Manufactured Test Article for Plasma-Facing Components

Current plasma-facing components (PFCs) used in helium-cooled divertor modules are complex structures with tungsten tile, steel sleeve components, and cartridges, all assembled in a helium-cooled multiple jet (HEMJ) structure. The goal of this project is to simplify the complex PFC design using additive manufacturing techniques to create a single integrated tungsten test article. Apart from the flexibility this opens up in exploring a wide array of geometries for the article, having a single integrated article significantly reduces the number of joints and parts in the article, thus reducing chances of leaks. A process called electron beam melting has shown to produce very high-density samples and unique geometries, enabling HEMJ or similar designs. To validate and optimize this novel design, the model underwent a series of computational fluid dynamics and finite element analysis simulations to replicate steady-state heat flux in the divertors. The simulations presented in this study consider a steady-state base heat flux of 5 MW/m 2 , with water serving as the coolant. Future research will explore the use of helium as a coolant, simulate edge-localized-mode conditions, and include experimental validation. Since 3D-printed tungsten is anisotropic, the build direction versus build plane of the article are taken into consideration for the test article strength. Because of the high operating temperatures and low ductility of tungsten, thermal creep and brittle fracture are important failure mechanisms to consider. In conclusion, the cap is evaluated with various flow velocities and nozzle diameters, and an optimal design choice is made for which this cap will survive the divertor conditions with a conservative safety margin.

Divertor↗

Multiphysics Co-Optimization Design and Analysis of Double-Side Cooled Silicon Carbide-Based Power Module: Preprint

With the rapid growth of Electric Vehicles (EVs) and Hybrid Electric Vehicles (HEVs), much more rigorous design targets have been set for automotive power electronics, including high power density, high reliability, and low cost. Novel power module and inverter technologies based on wide bandgap (WEG) semiconductors have been developed to meet these design targets, while providing optimal power semiconductor operating temperature and promising thermomechanical performance. Compared with conventional cooling techniques which are normally applied only on one side of power module, double-side cooling approach is now believed to be the solution to enable high power density and low thermal resistance of WEG semiconductor-based power electronics. In this work, we develop a three-phase power module that is double-sided cooled using dielectric fluid jet impingement. In each phase, four silicon carbide (SiC) power semiconductors are bonded to copper busbars without electrical insulation layers. A finite element analysis (FEA) model is created for thermal and thermomechanical analysis. Based on FEA modeling results, we select particular dimensions for a parametric study to optimize thermal and mechanical performance. Using a multi-objective genetic algorithm (MOGA)-based optimization method, we have minimized the maximum junction temperature and thermal stresses within the power module. The multiphysics co-optimization approach has enabled an efficient design process of power modules with greatly reduced computational cost, as compared to conventional processes that rely on exhaustive numerical simulations and iterations.

ADVANCED PROPULSION SYSTEMS↗

Parameter extraction approaches for compact modeling of thermoelectric modules

Thermoelectric (TE) cooling has experienced rapid advancements with the foundational understanding of TE materials. TE modules, compact and lightweight devices, have become the prevalent approach for implementing TE technologies. Accurately quantifying TE physical parameters (Seebeck coefficient α, thermal conductivity κ, and thermal resistance ρ) is challenging due to the dynamic temperature changes in operation. Furthermore, extracting lumped property parameters is crucial for designing energy systems using TE modules. Existing research has several limitations, such as lack of comparative analysis between prevalent formulae, reliance on potentially inaccurate vendor-supplied data, disregard for fundamental assumptions, and absence of empirical measurements. Further, this study addresses these gaps by conducting TE material characterization, comparing three existing formulae using vendor datasheets, designing a laboratory test facility for model validation and refinement, and outlining a structured data extraction procedure. The study's novelty lies in multiple key contributions: (1) a detailed comparative analysis of existing formulae for extracting TE property parameter; (2) executing experimental work in a laboratory setting to validate the model and elucidate its limitations; (3) highlighting potential risks; (4) clarifying possible assumptions from both material and engineering perspectives; and (5) considering temperature differential impacts. This comprehensive approach addresses the current research gaps and provides valuable insights into the design and application of TE modules in various energy systems.

36 MATERIALS SCIENCE↗

Quality concerns caused by quality control — deformation of silicon strip detector modules in thermal cycling tests

The ATLAS experiment at the Large Hadron Collider (LHC) is currently preparing to replace its present Inner Detector (ID) with the upgraded, all-silicon Inner Tracker (ITk) for its High-Luminosity upgrade (HL-LHC). The ITk will consist of a central pixel tracker and the outer strip tracker, consisting of about 19,000 strip detector modules. Each strip module is assembled from up to two sensors, and up to five flexes (depending on its geometry) in a series of gluing, wirebonding and quality control steps. During detector operation, modules will be cooled down to temperatures of about -35 °C (corresponding to the temperature of the support structures on which they will be mounted) after being initially assembled and stored at room temperature. In order to ensure compatibility with the detector's operating temperature range, modules are subjected to thermal cycling as part of their quality control process. Ten cycles between -35 °C and +40 °C are performed for each module, with full electrical characterisation tests at each high and low temperature point. As part of an investigation into the stress experienced by modules during cooling, it was observed that modules generally showed a change in module shape before and after thermal cycling. This paper presents a summary of the discovery and understanding of the observed changes, connecting them with excess module stress, as well as the resulting modifications to the module thermal cycling procedure.

47 OTHER INSTRUMENTATION↗

Single-Phase Dielectric Fluid Thermal Management for Power-Dense Automotive Power Electronics

This paper describes the design and performance of a dielectric fluid cooling concept for automotive power electronics. The concept combines a low-thermal-resistance package (which eliminates metalized ceramic substrates) with a high-performance convective cooling strategy (slot jets impinging on finned surfaces). Modeling was first used to design the cooling system to maximize thermal performance and minimize pumping power. Additionally, a prototype was then fabricated, and experiments were conducted to validate the model predictions using three fluids at various fluid flow rates (16.7 cm 3 /s [1 L/min] to 68.3 cm 3 /s [4.1 L/min]) and inlet temperatures (30C and 70C). The final design was compact (120-cm 3 total volume, including heat exchanger and conceptual power modules) and cooled 12 devices (e.g., silicon carbide). The validated model was then used to predict the junction-to-fluid thermal resistance and pumping power for various conditions, including 40C fluid temperature. The results predict thermal resistance values as low as 19 mm 2 K/W are possible using the dielectric fluid cooling approach. The dielectric fluid cooling system is predicted to provide thermal resistance and pumping power values that are approximately 56% and 90% lower, respectively, compared to an automotive power electronics cooling system.

30 DIRECT ENERGY CONVERSION↗

Single and Double-Sided Jet Impingement Cooling for SiC-Based Power Modules

Efficient thermal management of power electronics systems is crucial for higher reliability. With the miniaturization of systems, high-loss-density electronics require cooling systems that can extract a large amount of heat. This study explored a liquid-jet-impingement-based direct substrate cooling system for single-sided and double-sided cooling to improve heat extraction efficiency and improve the power density by reducing the volume and mass. The cooling system was implemented for a SiC-based direct bonded copper substrate. Numerical simulations were performed to determine the effects of nozzle diameter, the number of nozzles, and nozzle array orientation on single-sided cooling and thermal performance gain over double-sided cooling. A novel manifold design was proposed that reduced the volume and mass of the manifold and still achieved the target power density. The performance of the proposed design was compared with the pin-fin-based cooling system used in the BMW I3 module, and a comparative analysis was done.

Barua, Himel↗

pyJSPEC - A Python Module for IBS and Electron Cooling Simulation

The intrabeam scattering is an important collective effect that can deteriorate the property of a high-intensity beam and electron cooling is a method to mitigate the IBS effect. JSPEC (JLab Simulation Package on Electron Cooling) is an open-source C++ program developed at Jefferson Lab, which simulates the evolution of the ion beam under the IBS and/or the electron cooling effect. The Python wrapper of the C++ code, pyJSPEC, for Python 3.x environment has been recently developed and released. It allows the users to run JSPEC simulations in a Python environment. It also makes it possible for JSPEC to collaborate with other accelerator and beam modeling programs as well as plentiful python tools in data visualization, optimization, machine learning, etc. In this paper, we will introduce the features of pyJSPEC and demonstrate how to use it with sample codes and numerical results.

Zhang, H.↗

A Smart Silicon Carbide Power Module With Pulse Width Modulation Over Wi-Fi and Wireless Power Transfer-Enabled Gate Driver, Featuring Onboard State of Health Estimator and High-Voltage Scaling Capabilities: Preprint

A wide range of utility applications require controllable switches with features such as high-voltage (HV) blocking and high-current carrying capacity especially at high pulse width modulation (PWM) frequency. Low and medium voltage utility applications such as motor drives and flexible AC transmission systems (FACTS) as well as solid state transformers (SST) could also benefit from a low-cost HV switching module. Wide band gap (WBG) semiconductors such as SiC and GaN MOSFETs are considered to be the present and next generation device choices, although they have their own limitations. For relatively HV applications with demanding thermal management, SiC is still the only choice, and GaN dominates the low voltage regime. This manuscript proposes a new half bridge power MOSFET module that is suitable for conventional H-bridge of multilevel configurations used in HV applications. Constructed from bare SiC dies, this half bridge module takes advantage of (1) optimized MOSFET placement inside the module, (2) customized heat exchanger, manifold and cooling, (3) integrated gate driver module with PWM over wi-fi to eliminate the need for low voltage signals, (4) wireless power transfer (WPT) enabled gate driver and other ancillary circuits, (5) and the option to incorporate an onboard state of health (SOH) estimator module onboard. The entire architecture has been designed and built at National Renewable Energy Laboratory (NREL), Golden, CO.

baseplate design↗

Advanced Fuel Cycle Cost Basis Report: Module D1-4 and Module D1-5 Ceramic Pelletized Sodium-Cooled Fast Reactor (SFR) Fuel Fabrication Ceramic Vibrocompacted Fuel Fabrication

This is a cost module that is part of the Advanced Fuel Cycle -- Cost Basis Report. Module D1-4: Nature of this module update (Rev 1) from previous advanced fuel cycle cost basis reports (AFCCBRs): new life cycle cost data on U,Pu SFR mixed oxide (MOX) fuels is derived from the Nonproliferation Assessment Systems Analysis Program (NASAP) conducted in the late 1970s. Highassay low-enriched uranium (HALEU) ceramic fuel is also discussed in more detail compared to earlier AFC-CBRs, since some advanced SFR concepts currently under development will require this HALEU fuel type for startup. Module D1-5: Nature of this FY-21 module update from previous AFC-CBRs: this module includes a few new references and a somewhat expanded discussion of vibrocompaction fuel fabrication technology. The WIT values for VIPAC are pegged directly to those for conventional LWR and SFR pelletized U,Pu MOX (note that this module now includes VIPAC MOX fuel for LWRs in addition to SFRs). Based on information from Russia, where VIPAC has been studied extensively, the unit costs are expressed as a percentage of those in the new updated Module D1-2 (pelletized U,Pu MOX) and new updated Module D1-4 (pelletized U,Pu MOX) for large NOAK fabrication facilities of the same production capacity. Since both ceramic pelletized MOX Modules D1-2 and D1-4 benefitted from analysis of 1970s NASAP data, by extension this Module D1-5 also benefits.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Combustion Performance and Emissions Optimization Through Integration of a Miniaturized High-Temperature Multi Process Monitoring System

The main objective of this research program is to design, manufacture, and demonstrate a miniaturized, multi-process, monitoring system (mMPMS) for boiler condition management and easy system deployment to obtain a higher spatial resolution. This system will facilitate a Condition-Based Maintenance (CBM) philosophy that actively monitors the health of assets to predict and prevent failures and maximize availability and generating capacity at a reduced cost. CBM systems can provide boiler data that the advanced process control (APC) system can utilize for plant performance optimization, which is increasingly relevant as coal power plants shift from predominantly base-load operation to predominantly transient operation involving large load swings. The mMPMS is based on an electrochemical sensor that provides a real-time indication of the risk of damage to key locations in the radiant or convective section of a coal-fired boiler such as metal loss rates, heat flux, metal surface temperature, and deposit thickness. These indications can be utilized to optimize boiler performance as well as improve boiler availability in conjunction with corresponding operating conditions. This monitoring system was developed and tested in the high-temperature regions of coal-fired utility boilers in this project but can be applied to many other industries and applications as well. This project leveraged the existing electrochemical noise-based monitoring system and the new sensor design is small enough to be installed through the webbing of the waterwalls without the need for long shut-downs to bend tubes and to make it feasible to obtain high spatial resolution in the boiler. Data is transferred to the plant distributed control system (DCS) and any other control system. The sensor body that houses the sensor assembly was designed to ensure good conductive contact with boiler tubes to ensure the sensor is held at an identical temperature to the tube surface temperature. The data acquisition and signal conditioning modules were redesigned into a small footprint with optimized cooling of the module. System software was developed specifically for the new signal conditioning module and is compatible with plant PLCs. After the preliminary testing at a pilot-scale facility, five mMPMS were installed at a full-scale pulverized coal-fired plant, Basin Electric Power Cooperative’s Leland Olds Unit 1. The systems were demonstrated over a 6-week period during typical operation. Sensor measurements of deposit thickness were validated during the demonstration and subsequently leveraged to determine sensor-based boiler cleaning strategies. These strategies have the benefit of reduced thermal stresses on boiler tubes from over-cleaning and improved boiler water management. At the end of the project, continued development of the sensor technology was carried out at PacifiCorp’s Hunter Station. REI leveraged the permanent installation of the mMPMS in Unit 3 made possible by DOE funding on a separate program. The work at Hunter Plant focused on application of machine learning and artificial intelligence-based models for integration of sensor signals into control and optimization of Hunter Unit 3 processes.

Advanced Sensors, Corrosion, Ash Deposition, Optim↗

Combustion Performance and Emissions Optimization through Integration of Miniaturized High Temperature Multi Process Monitoring System

The main objective of this research program is to design, manufacture, and demonstrate a miniaturized, multi-process, monitoring system (mMPMS) for boiler condition management and easy system deployment to obtain a higher spatial resolution. This system will facilitate a Condition-Based Maintenance (CBM) philosophy that actively monitors the health of assets to predict and prevent failures and maximize availability and generating capacity at a reduced cost. CBM systems can provide boiler data that the advanced process control (APC) system can utilize for plant performance optimization, which is increasingly relevant as coal power plants shift from predominantly base-load operation to predominantly transient operation involving large load swings. The mMPMS is based on an electrochemical sensor that provides a real-time indication of the risk of damage to key locations in the radiant or convective section of a coal-fired boiler such as metal loss rates, heat flux, metal surface temperature, and deposit thickness. These indications can be utilized to optimize boiler performance as well as improve boiler availability in conjunction with corresponding operating conditions. This monitoring system was developed and tested in the high-temperature regions of coal-fired utility boilers in this project but can be applied to many other industries and applications as well. The new sensor design, leveraging the existing electrochemical noise-based monitoring system, is small enough to be installed through the webbing of the waterwalls without the need for long shut-downs to bend tubes and to make it feasible to obtain high spatial resolution in the boiler. Data can be transferred to the plant distributed control system (DCS) and any other control system. The sensor body that houses the sensor assembly was designed to ensure good conductive contact with boiler tubes to ensure the sensor is held at an identical temperature to the tube surface temperature. The data acquisition and signal conditioning modules were redesigned into a small footprint with optimized cooling of the module. System software was developed specifically for the new signal conditioning module and is compatible with plant PLCs. After the preliminary testing at a pilot-scale facility, five mMPMS were installed at a full-scale pulverized coal-fired plant, Basin Electric Power Cooperative’s Leland Olds Unit 1. The systems were demonstrated over a 6-week period during typical operation. Sensor measurements of deposit thickness were validated during the demonstration and subsequently leveraged to determine sensor-based boiler cleaning strategies. These strategies have the benefit of reduced thermal stresses on boiler tubes from over-cleaning and improved boiler water management. At the end of the project, continued development of the sensor technology was carried out at PacifiCorp’s Hunter Station. REI leveraged the permanent installation of the mMPMS in Unit 3 made possible by DOE funding on a separate program. The work at Hunter Plant focused on application of machine learning and artificial intelligence-based models for integration of sensor signals into control and optimization of Hunter Unit 3 processes.

Advanced Sensors, Corrosion, Ash Deposition, Optim↗

Combustion Performance and Emissions Optimization Through Integration of a Miniaturized High-Temperature Multi Process Monitoring System

The main objective of this research program is to design, manufacture, and demonstrate a miniaturized, multi-process, monitoring system (mMPMS) for boiler condition management and easy system deployment to obtain a higher spatial resolution. This system will facilitate a Condition-Based Maintenance (CBM) philosophy that actively monitors the health of assets to predict and prevent failures and maximize availability and generating capacity at a reduced cost. CBM systems can provide boiler data that the advanced process control (APC) system can utilize for plant performance optimization, which is increasingly relevant as coal power plants shift from predominantly base-load operation to predominantly transient operation involving large load swings. The mMPMS is based on an electrochemical sensor that provides a real-time indication of the risk of damage to key locations in the radiant or convective section of a coal-fired boiler such as metal loss rates, heat flux, metal surface temperature, and deposit thickness. These indications can be utilized to optimize boiler performance as well as improve boiler availability in conjunction with corresponding operating conditions. This monitoring system was developed and tested in the high-temperature regions of coal-fired utility boilers in this project but can be applied to many other industries and applications as well. The new sensor design, leveraging the existing electrochemical noise-based monitoring system, is small enough to be installed through the webbing of the waterwalls without the need for long shut-downs to bend tubes and to make it feasible to obtain high spatial resolution in the boiler. Data can be transferred to the plant distributed control system (DCS) and any other control system. The sensor body that houses the sensor assembly was designed to ensure good conductive contact with boiler tubes to ensure the sensor is held at an identical temperature to the tube surface temperature. The data acquisition and signal conditioning modules were redesigned into a small footprint with optimized cooling of the module. System software was developed specifically for the new signal conditioning module and is compatible with plant PLCs. After the preliminary testing at a pilot-scale facility, five mMPMS were installed at a full-scale pulverized coal-fired plant, Basin Electric Power Cooperative’s Leland Olds Unit 1. The systems were demonstrated over a 6-week period during typical operation. Sensor measurements of deposit thickness were validated during the demonstration and subsequently leveraged to determine sensor-based boiler cleaning strategies. These strategies have the benefit of reduced thermal stresses on boiler tubes from over-cleaning and improved boiler water management. At the end of the project, continued development of the sensor technology was carried out at PacifiCorp’s Hunter Station. REI leveraged the permanent installation of the mMPMS in Unit 3 made possible by DOE funding on a separate program. The work at Hunter Plant focused on application of machine learning and artificial intelligence-based models for integration of sensor signals into control and optimization of Hunter Unit 3 processes.

Advanced Sensors, Corrosion, Ash Deposition, Optim↗