Improving Module Temperature Measurements using Averaging Resistive Temperature Devices.
Abstract not provided.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided.
Cracks in crystalline silicon solar cells can lead to substantial power loss. While the cells' metal contacts can initially bridge these cracks and maintain electrical connections, the bridges are damaged by mechanical loads, including those due to temperature changes. We investigated the metallization bridges that form over cracks in encapsulated silicon solar cells. Microscopic characterization showed that the crack in the silicon can immediately propagate through the metal grid, but the grid can maintain electrical contact once the load is removed. We also quantified the movement of the cell fragments separated by a crack as a function of temperature. Cell fragments are free to move diagonally and to rotate, so the change in gap across the crack during a temperature change varies along the length of the crack. In one sample, we showed that a 10 degrees C temperature change, causing a 2 um increase in the separation of cell fragments, was sufficient to cause a reversible electrical disconnection of metallization bridging a crack.
Abstract Not Provided
Abstract Not Provided
Abstract not provided.
Water Power Calculator Temperature and Analog input/output Module Ambient Temperature Testing A series of three ambient temperature tests were conducted for the Water Power Calculator development using the INL Calibration Laboratory’s Tenney Environmental Chamber. The ambient temperature test results demonstrate that the Moore Industries Temperature Input Modules, Analog Input Module and Analog Output Module, ambient temperature response meet or exceed the manufactures specifications
This dataset contains over two years of 1-minute resolution data collected from four floating solar sites, as well as data from a land-based PV system co-located with one of the floating sites. The dataset includes highly granular module temperature measurements - five modules per floating site, with three sensors per module, totaling 15 module temperature sensors per floating site. In addition to the module temperature data, meteorological data collected at the floating sites is also included, along with traditional PV system-level parameters. The data is intended for analysis of solar energy production, efficiency, and performance degradation over time. For information about the data file usage see the "README" resource below. See "Metadata File" for information about individual files and other metadata information.
Although Soil and Water Assessment Tool (SWAT) has been widely used in temperate regions, the performance of its soil temperature module has not been extensively assessed. The aim of the present study was to evaluate the performance of the SWAT model’s built-in empirical soil temperature module and a physically-based soil temperature algorithm using four years of daily soil temperature measurements at three depths (i.e., 5, 10, and 50 cm) across 10 monitoring stations in and around the Choptank River watershed, Maryland, USA. Two versions of physically-based soil temperature module were considered: one was calibrated using parameter values adopted from previous studies, another one remained calibrated. Results show that the empirical soil temperature module and both versions of physically-based soil temperature module reproduce well variations of measured soil temperatures at 5 and 10 cm depths for all stations in non-winter seasons. However, the empirical and uncalibrated physically-based soil temperature modules tended to underestimate soil temperatures in non-winter seasons at the deeper soil layer (50 cm depth); they also severely underestimated soil temperatures in winter for soil surface layers (5 and 10 cm depths). Results indicate that the calibrated physically-based soil temperature module improved soil temperature simulation, especially for winter due to its accounting for insulation effect of crop residue on soil surface. This study suggested that when equipping a physically-based soil temperature module in a hydrological model, a better representation of surface residue was needed for applications in agricultural watersheds and assessing best management practices.
The Photovoltaic Systems Evaluation Laboratory (PSEL) at Sandia National Laboratories (SNL) in Albuquerque, NM has an extensive test site where PV modules and other system components are deployed and monitored for testing and evaluation. For this dataset PV Performance Labs has assembled one year of measurements from the Systems Long-Term Evaluation (SLTE) project (formerly known as PV Lifetime) providing the main variables needed to investigate and validate PV module operating temperature models: irradiance, ambient temperature, wind speed and back-of-module temperature. For use with more advanced thermal modeling, an estimate of down-welling long-wave radiation is also included.
Encapsulant browning is one of the most common degradation modes found in crystalline silicon field-aged photovoltaic modules. Browning, usually undetected unless severe, reduces the short-circuit current (Isc) produced by a module. Therefore, field-aged browned modules have been subjected to accelerated UV testing to obtain true end-of-life activation energy for the encapsulant browning mechanism. A novel time- and resource-saving accelerated UV exposure testing method simultaneously allowing multiple module temperatures to be maintained in a single chamber run is presented. Six field-aged crystalline silicon modules of glass/backsheet construction (three each from BP Solar/Solarex MSX 60 and Siemens M55) with similar glass and encapsulant formulation were exposed to a UV dosage of 450 kWh/m2 . Through passive heating, the average module temperatures for the BP Solar/Solarex modules were 60 degrees C, 77 degrees C, and 85 degrees C and those of Siemens M55 were 75 degrees C, 80 degrees C, and 837 degrees C. To study UV browning, the modules were intermittently characterized through visual imaging, UV fluorescence imaging, electroluminescence imaging, quantum efficiency measurements, module, and cell-level light I-V measurements. An Isc decrease corroborated the increased extent of browning with increased module temperature. For the BP Solar/Solarex modules, the Low T, Mid T, and the High T modules showed a 1.37%, 2.48%, and 3.26% Isc drop, respectively. The Siemens modules showed a 4.11%, 5.65%, and 6.95% Isc drop. The multiple cell-level Isc data points obtained for each module temperature increased provided statistical significance. Activation energy for encapsulant browning was calculated as 0.44 and 0.72 eV for MSX 60 and M55 modules, respectively.
Explore the source record for details and available documents.
Domestic hot water (DHW) heating is the second largest energy end use in U.S. buildings, exceeded only by space conditioning. Recirculation systems consisting of a pump and piping loop(s) are commonly used in multifamily buildings to reduce wait time for hot water at faucets; however, constant pumping increases energy consumption by exposing supply and return line piping to continuous heat loss, even during periods when there is no demand for hot water. In this study, ARIES installed and tested two types of recirculation controls in a pair of buildings in order to evaluate their energy savings potential. Demand control, temperature modulation controls, and the simultaneous operation of both were compared to the baseline case of constant recirculation. Additionally, interactive effects between DHW control fuel reductions and space conditioning (heating and cooling) were estimated in order to make more realistic predictions of the payback and financial viability of retrofitting DHW systems with these controls. Results showed that DHW fuel consumption reduced by 7% after implementing the demand control technique, 2% after implementing temperature modulation, and 15% after implementing demand control and temperature modulation techniques simultaneously; recirculation pump runtime was reduced to 14 minutes or less per day. With space heating and cooling interactions included, the estimated annual cost savings were 8%, 1%, and 14% for the respective control techniques. Possible complications in the installation, commissioning and operation of the controls were identified and solutions offered.
Domestic hot water (DHW) heating is the second largest energy end use in U.S. buildings, exceeded only by space conditioning. Recirculation systems consisting of a pump and piping loop(s) are commonly used in multifamily buildings to reduce wait time for hot water at faucets; however, constant pumping increases energy consumption by exposing supply and return line piping to continuous heat loss, even during periods when there is no demand for hot water. In this study, ARIES installed and tested two types of recirculation controls in a pair of buildings in order to evaluate their energy savings potential. Demand control, temperature modulation controls, and the simultaneous operation of both were compared to the baseline case of constant recirculation. Additionally, interactive effects between DHW control fuel reductions and space conditioning (heating and cooling) were estimated in order to make more realistic predictions of the payback and financial viability of retrofitting DHW systems with these controls. Results showed that DHW fuel consumption reduced by 7% after implementing the demand control technique, 2% after implementing temperature modulation, and 15% after implementing demand control and temperature modulation techniques simultaneously; recirculation pump runtime was reduced to 14 minutes or less per day. With space heating and cooling interactions included, the estimated annual cost savings were 8%, 1%, and 14% for the respective control techniques. Possible complications in the installation, commissioning and operation of the controls were identified and solutions offered.
Domestic hot water (DHW) heating is the second largest energy end use in U.S. buildings, exceeded only by space conditioning. Recirculation systems consisting of a pump and piping loop(s) are commonly used in multifamily buildings to reduce wait time for hot water at faucets; however, constant pumping increases energy consumption by exposing supply and return line piping to continuous heat loss, even during periods when there is no demand for hot water. In this study, ARIES installed and tested two types of recirculation controls in a pair of buildings in order to evaluate their energy savings potential. Demand control, temperature modulation controls, and the simultaneous operation of both were compared to the baseline case of constant recirculation. Additionally, interactive effects between DHW control fuel reductions and space conditioning (heating and cooling) were estimated in order to make more realistic predictions of the payback and financial viability of retrofitting DHW systems with these controls. Results showed that DHW fuel consumption reduced by 7% after implementing the demand control technique, 2% after implementing temperature modulation, and 15% after implementing demand control and temperature modulation techniques simultaneously; recirculation pump runtime was reduced to 14 minutes or less per day. With space heating and cooling interactions included, the estimated annual cost savings were 8%, 1%, and 14% for the respective control techniques. Possible complications in the installation, commissioning and operation of the controls were identified and solutions offered.
Domestic hot water (DHW) heating is the second largest energy end use in U.S. buildings, exceeded only by space conditioning. Recirculation systems consisting of a pump and piping loop(s) are commonly used in multifamily buildings to reduce wait time for hot water at faucets; however, constant pumping increases energy consumption by exposing supply and return line piping to continuous heat loss, even during periods when there is no demand for hot water. In this study, ARIES installed and tested two types of recirculation controls in a pair of buildings in order to evaluate their energy savings potential. Demand control, temperature modulation controls, and the simultaneous operation of both were compared to the baseline case of constant recirculation. Additionally, interactive effects between DHW control fuel reductions and space conditioning (heating and cooling) were estimated in order to make more realistic predictions of the payback and financial viability of retrofitting DHW systems with these controls. Results showed that DHW fuel consumption reduced by 7 percent after implementing the demand control technique, 2 percent after implementing temperature modulation, and 15 percent after implementing demand control and temperature modulation techniques simultaneously; recirculation pump runtime was reduced to 14 minutes or less per day. With space heating and cooling interactions included, the estimated annual cost savings were 8 percent, 1 percent, and 14 percent for the respective control techniques. Possible complications in the installation, commissioning and operation of the controls were identified and solutions offered.
When photovoltaic (PV) modules are installed on rooftops, the module temperature depends primarily on the geographic location and the mounting configuration. If the mounting structure does not provide sufficient airflow in a hot environment, the 98th percentile temperature will exceed 70°C, which according to IEC TS 63126 ED. 1, requires higher levels of thermal stability testing. However, there is no clear way to determine the temperature level needed for a particular location and system design. Here, in this work, we identify a relationship between the module standoff to the rooftop and the module temperature and propose methods to describe a minimum standoff for typical PV modules in a simple mounting configuration installed in a given location. For more complex system designs, we show how to determine an equivalent “effective standoff” that can be applied to generic calculations. Lastly, we show measurements and calculations from several systems to demonstrate how this method could work.
ICRF (ion cyclotron range of frequencies) heating experiments were performed in D-H plasmas at various H concentrations on ASDEX Upgrade. The rf power was modulated to measure the electron power deposition profile from electron temperature modulation. To minimize the contribution from indirect collisional heating and the effect of radial transport, the rf power was modulated at 50 Hz. However, peaking of electron temperature modulation was still observed around the hydrogen cyclotron resonance indicating collisional heating contribution. Time dependent simulation of the hydrogen distribution function was performed for the discharges, using the full-wave code AORSA (E.F. Jaeger, et al., Phys. Plasmas, Vol. 8, page 1573 (2001)) coupled to the Fokker-Planck code CQL3D (R.W. Harvey, et al., Proc. IAEA (1992)). In the present experimental conditions, it was found that modulation of the collisional heating was comparable to that of direct wave damping. Impact of radial transport was also analyzed and found to appreciably smear out the modulation profile and reduce the phase delay.