Search NASA⌕ Search

SEARCH · Search NASA

Results for “molecular scattering”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Exploring a New Regime of Molecular Orbital Physics in 4⁢d Cluster Magnets with Resonant Inelastic X-Ray Scattering

Molecular orbital systems with clusters of heavy transition metal (TM) ions are one of the most important classes of model materials for studying the interplay between local physics and effects of itinerancy. Despite a large number of candidates identified in the family of 4⁢d TM materials, an understanding of their physics from competing microscopic energy scales is still missing. Here, we bridge this gap by reporting the first resonant inelastic x-ray scattering (RIXS) measurement on a well-known series of Ru cluster magnets with a 6⁢H-perovskite structure Ba 3 ⁢M⁢Ru 2 ⁢O 9 (M 3+ = In 3+ , Y 3+ , La 3+ ) comprised of Ru dimers. In addition to providing a microscopic explanation for their anomalous magnetic properties, our RIXS measurements combined with theoretical modeling uncover a new regime of molecular orbital physics where the combined effect of large hopping and small spin-orbit coupling results in highly fragile electronic states in the Ru-dimer compounds directly manifested as an abrupt change in the RIXS spectrum accompanying a tiny change in the local structure tuned by the M-site ion. This unique combination of energy scales found only in the 4⁢d but not the 5⁢d cluster magnets highlights the value of these materials as a new platform for studying quantum phase transition involving molecular orbitals.

36 MATERIALS SCIENCE↗

Polarization Calibration Using Solar Radiation Background Signal Scattered from Dense Cirrus Clouds in the Visible and Ultraviolet Wavelength Regimes

In this presentation we describe the application of a previously developed technique that is now being used to correct the daytime polarization calibration of the CALIPSO lidar. The technique leverages the fact that the solar radiation background signals from dense cirrus clouds are largely unpolarized due to the internal multiple reflections within the non-spherical ice particles and the multiple scattering that occurs among these particles. Therefore, the ratio of polarization components of the cirrus background signals provides a good estimate for the polarization gain ratio (PGR) of the lidar. Using airborne backscatter lidar measurements, this technique was demonstrated to work well in the infrared regime. However, in the visible and ultraviolet regime, the molecular contribution is too large to be ignored, and thus corrections must be applied to account for the highly polarizing characteristics of the molecular scattering. Ignoring molecular scattering contributions can cause PGR errors of 2-3% at 532 nm, where the CALIPSO lidar makes its depolarization measurement. Because of the wavelength dependence of -4 of the molecular scattering, the PGR error can be even larger at the 355 nm wavelength that will be used by ESA’s EarthCARE lidar. To correct the molecular scattering contributions to the lidar received solar background signal, a look-up table has been created using a polarization-sensitive radiative transfer model. This presentation describes the theory and implementation of the molecular scattering correction.

Zhaoyan Liu↗

Molecular beam scattering from C-13 enriched Kapton and correlation with the EOIM-3 carousel experiment

Mass spectra of products emerging from identical samples of a C-13-enriched polyimide polymer (chemically equivalent to Kapton) under atomic oxygen bombardment in space and in the laboratory were collected. Reaction products unambiguously detected in space were CO-13, NO, (12)CO2, and (13)CO2. These reaction products and two others, H2O and CO-12, were detected in the laboratory, along with inelastically scattered atomic and molecular oxygen. Qualitative agreement was seen in the mass spectra taken in space and in the laboratory; the agreement may be improved by reducing the fraction of O2 in the laboratory molecular beam. Both laboratory and space data indicated that CO and CO2 products come preferentially from reaction with the imide component of the polymer chain, raising the possibility that the either component may degrade in part by the 'evaporation' of higher molecular weight fragments. Laboratory time-of-flight distributions showed: (1) incomplete energy accommodation of impinging O and O2 species that do not react with the surface; and (2) both hyperthermal and thermal CO and CO2 products, suggesting two distinct reaction mechanisms with the surface.

Minton, Timothy K.↗

Ultraviolet Molecular Rayleigh Scattering Used to Measure Velocity in High-Speed Flow

Molecular Rayleigh scattering offers a means to measure gas flow parameters including density, temperature, and velocity. No seeding of the flow is necessary. The Rayleigh scattered power is proportional to the gas density, the spectral width is related to the gas temperature, and the shift in the frequency of the spectral peak is proportional to one component of the fluid velocity. Velocity measurements based on Rayleigh scattering are more suitable for high-speed flow, where the bulk fluid velocity is on the order of, or larger than, the molecular thermal velocities. Use of ultraviolet wavelengths for Rayleigh scattering diagnostics is attractive for two reasons. First, the Rayleigh scattering cross section is proportional to the inverse 4th power of the wavelength. And second, the reflectivity of metallic surfaces is generally less than it is at longer wavelengths. This is of particular interest in confined flow situations, such as in small wind tunnels and aircraft engine components, where the stray laser light scattered from the windows and internal surfaces in the test facility limits the application of Rayleigh scattering diagnostics. In this work at the NASA Lewis Research Center, molecular Rayleigh scattering of the 266-nm fourth harmonic of a pulsed, injection seeded Nd:YAG (neodymium:yttriumaluminum- garnet) laser was used to measure velocity in a supersonic free air jet with a 9.3- mm exit diameter. The frequency of the Rayleigh scattered light was analyzed with a planar mirror Fabry-Perot interferometer used in a static imaging mode, with the images recorded on a cooled, high-quantum-efficiency charge-coupled discharge (CCD) camera. In addition, some unshifted light from the same laser pulse was imaged through the interferometer to generate a reference. Data were obtained with single laser pulses at velocities up to Mach 1.3. The measured velocities were in good agreement with velocities calculated from isentropic flow relations. Our conclusion from this study was that ultraviolet Rayleigh scattering is preferable in confined flow situations because of the increase in the ratio of Rayleigh scattering signal to stray laser light. On the other hand, in open flows, such as free jets and larger wind tunnels where stray laser light can be controlled, visible Rayleigh scattering is preferable.

Seasholtz, Richard G.↗

Time-Average Measurement of Velocity, Density, Temperature, and Turbulence Using Molecular Rayleigh Scattering

Measurement of time-averaged velocity, density, temperature, and turbulence in gas flows using a nonintrusive, point-wise measurement technique based on molecular Rayleigh scattering is discussed. Subsonic and supersonic flows in a 25.4-mm diameter free jet facility were studied. The developed instrumentation utilizes a Fabry-Perot interferometer to spectrally resolve molecularly scattered light from a laser beam passed through a gas flow. The spectrum of the scattered light contains information about velocity, density, and temperature of the gas. The technique uses a slow scan, low noise 16-bit depth CCD camera to record images of the fringes formed by Rayleigh scattered light passing through the interferometer. A kinetic theory model of the Rayleigh scattered light is used in a nonlinear least squares fitting routine to estimate the unknown parameters from the fringe images. The ability to extract turbulence information from the fringe image data proved to be a challenge since the fringe is broadened by not only turbulence, but also thermal fluctuations and aperture effects from collecting light over a range of scattering angles. Figure 1 illustrates broadening of a Rayleigh spectrum typical of flow conditions observed in this work due to aperture effects and turbulence for a scattering angle, chi(sub s), of 90 degrees, f/3.67 collection optics, mean flow velocity, u(sub k), of 300 m/s, and turbulent velocity fluctuations, sigma (sub uk), of 55 m/s. The greatest difficulty in processing the image data was decoupling the thermal and turbulence broadening in the spectrum. To aid in this endeavor, it was necessary to seed the ambient air with smoke and dust particulates; taking advantage of the turbulence broadening in the Mie scattering component of the spectrum of the collected light (not shown in the figure). The primary jet flow was not seeded due to the difficulty of the task. For measurement points lacking particles, velocity, density, and temperature information could reliably be recovered, however the turbulence estimates contained significant uncertainty. Resulting flow parameter estimates are presented for surveys of Mach 0.6, 0.95, and 1.4 jet flows. Velocity, density, and temperature were determined with accuracies of 5 m/s, 1.5%, and 1%, respectively, in flows with no particles present, and with accuracies of 5 m/s, 1-4%, and 2% in flows with particles. Comparison with hotwire data for the Mach 0.6 condition demonstrated turbulence estimates with accuracies of about 5 m/s outside the jet core where Mie scattering from dust/smoke particulates aided in the estimation of turbulence. Turbulence estimates could not be recovered with any significant accuracy for measurement points where no particles were present.

Mielke, Amy F.↗

Rayleigh scattering

The physical phenomena of molecular scattering are examined with the objective of redefining the confusing terminology currently used. The following definitions are proposed: molecular scattering consists of Rayleigh and vibrational Raman scattering; the Rayleigh scattering consists of rotational Raman lines and the central Cabannes line; the Cabannes line is composed of the Brillouin doublet and the central Gross or Landau-Placzek line. The term 'Rayleigh line' should never be used.

Young, A. T.↗

Evaporation and Molecular Beam Scattering from a Flat Liquid Jet

An experimental setup for molecular beam scattering from flat liquid sheets has been developed, with the goal of studying reactions at gas–liquid interfaces for volatile liquids. Specifically, a crossed molecular beam instrument that can measure angular and translational energy distributions of scattered products has been adapted for liquid jet scattering. A microfluidic chip is used to create a stable flat liquid sheet inside vacuum from which scattering occurs, and both evaporation and scattering from this sheet are characterized using a rotatable mass spectrometer that can measure product time-of-flight distributions. This article describes the instrument and reports on the first measurements of evaporation of dodecane and Ne from a Ne-doped dodecane flat jet, as well as scattering of Ne from a flat jet of pure dodecane.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Molecular beam scattering from flat jets of liquid dodecane and water

Abstract Molecular beam experiments in which gas molecules are scattered from liquids provide detailed, microscopic perspectives on the gas–liquid interface. Extending these methods to volatile liquids while maintaining the ability to measure product energy and angular distributions presents a significant challenge. The incorporation of flat liquid jets into molecular beam scattering experiments in our laboratory has allowed us to demonstrate their utility in uncovering dynamics in this complex chemical environment. Here, we summarize recent work on the evaporation and scattering of Ne, CD 4 , ND 3 , and D 2 O from a dodecane flat liquid jet and present first results on the evaporation and scattering of Ar from a cold salty water jet. In the evaporation experiments, Maxwell–Boltzmann flux distributions with a cos θ angular distribution are observed. Scattering experiments reveal both impulsive scattering (IS) and trapping followed by thermal desorption (TD). Super‐specular scattering is observed for all four species scattered from dodecane and is attributed to anisotropic momentum transfer to the liquid surface. In the IS channel, rotational excitation of the polyatomic scatterers is a significant energy sink, and these species accommodate more readily on the dodecane surface compared to Ne. Our preliminary results on cold salty water jets suggest that Ar atoms undergo some vapor‐phase collisions when evaporating from the liquid surface. Initial scattering experiments characterize the mechanisms of Ar interacting with an aqueous jet, allowing for comparison to dodecane systems. Key Points Molecular beam scattering from flat liquid jets is a powerful technique to elucidate mechanistic detail at the gas–liquid interface. Previous dodecane scattering experiments have uncovered angularly‐resolved thermal desorption fractions and energy transfer at the interface for several small molecule scatterers. Preliminary results on scattering from cold salty water reveal mechanisms of interaction between argon and an aqueous jet.

Yang, Walt↗

Molecular beam scattering of neon from flat jets of cold salty water

Molecular beam scattering experiments are carried out to study collisions between Ne atoms (E i = 24.3 kJ mol-1) and the surface of a cold salty water (8 m LiBr(aq), 230 K) flat jet. Translational energy distributions are collected as a function of scattering angle using a rotatable mass spectrometer. Impulsive scattering and thermal desorption contribute to the overall scattering distributions, but impulsive scattering dominates at all three incidence angles explored. Highly super-specular scattering is observed in the impulsive scattering channel that is attributed to anisotropic momentum transfer to the liquid surface. The thermal desorption channel exhibits a cos θ angular distribution. Compared to Ne scattering from dodecane, fractional energy loss in the impulsive scattering channel is much larger across a wide range of deflection angles. A soft-sphere model is applied to investigate the kinematics of energy transfer between the scatterer and liquid surface. Fitting to this model yields an effective surface mass of 250-60 +100 amu and internal excitation of 11.8 ± 1.6 kJ mol-1, both of which are considerably larger than for Ne/dodecane. It thus appears that energy transfer to cold salty water is more efficient than to a dodecane liquid surface, a result attributed to the extensive hydrogen-bonded network of liquid water and roughness of the liquid surface.

Yang, Walt↗

Molecular Rayleigh Scattering Diagnostic for Dynamic Temperature, Velocity, and Density Measurements

A molecular Rayleigh scattering technique is developed to measure dynamic gas temperature, velocity, and density in unseeded turbulent flows at sampling rates up to 16 kHz. A high power CW laser beam is focused at a point in an air jet plume and Rayleigh scattered light is collected and spectrally resolved. The spectrum of the light, which contains information about the temperature and velocity of the flow, is analyzed using a Fabry-Perot interferometer. The circular interference fringe pattern is divided into four concentric regions and sampled at 1 and 16 kHz using photon counting electronics. Monitoring the relative change in intensity within each region allows for measurement of gas temperature and velocity. Independently monitoring the total scattered light intensity provides a measure of gas density. A low speed heated jet is used to validate the measurement of temperature fluctuations and an acoustically excited nozzle flow is studied to validate velocity fluctuation measurements. Power spectral density calculations of the property fluctuations, as well as mean and fluctuating quantities are presented. Temperature fluctuation results are compared with constant current anemometry measurements and velocity fluctuation results are compared with constant temperature anemometry measurements at the same locations.

Mielke, Amy R.↗

Multiple Point Dynamic Gas Density Measurements Using Molecular Rayleigh Scattering

A nonintrusive technique for measuring dynamic gas density properties is described. Molecular Rayleigh scattering is used to measure the time-history of gas density simultaneously at eight spatial locations at a 50 kHz sampling rate. The data are analyzed using the Welch method of modified periodograms to reduce measurement uncertainty. Cross-correlations, power spectral density functions, cross-spectral density functions, and coherence functions may be obtained from the data. The technique is demonstrated using low speed co-flowing jets with a heated inner jet.

Seasholtz, Richard↗