Search NASA⌕ Search

SEARCH · Search NASA

Results for “monodisperse particles”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Generation of monodisperse droplets by spontaneous condensation of flow in nozzles

Submicron size monodisperse particles are of interest in many industrial and scientific applications. These include the manufacture of ceramic parts using fine ceramic particles, the production of thin films by deposition of ionized clusters, monodisperse seed particles for laser anemometry, and the study of size dependence of cluster chemical and physical properties. An inexpensive and relatively easy way to generate such particles is by utilizing the phenomenon of spontaneous condensation. The phenomenon occurs when the vapor or a mixture of a vapor and a noncondensing gas is expanded at a high expansion rate. The saturation line is crossed with the supercooled vapor behaving like a gas, until all of a sudden at the so called Wilson point, condensation occurs, resulting in a large number of relatively monodisperse droplets. The droplet size is a function of the expansion rate, inlet conditions, mass fraction of vapor, gas properties, etc. Spontaneous condensation of steam and water vapor and air mixture in a one dimensional nozzle was modeled and the resulting equations solved numerically. The droplet size distribution at the exit of various one dimensional nozzles and the flow characteristics such as pressure ratio, mean droplet radius, vapor and droplet temperatures, nucleation flux, supercooling, wetness, etc., along the axial distance were obtained. The numerical results compared very well with the available experimental data. The effect of inlet conditions, nozzle expansion rates, and vapor mass fractions on droplet mean radius, droplet size distribution, and pressure ratio were examined.

Lai, Der-Shaiun↗

Method accurately measures mean particle diameters of monodisperse polystyrene latexes

Photomicrographic method determines mean particle diameters of monodisperse polystyrene latexes. Many diameters are measured simultaneously by measuring row lengths of particles in a triangular array at a glass-oil interface. The method provides size standards for electronic particle counters and prevents distortions, softening, and flattening.

Kubitschek, H. E.↗

Multi-Tiered Estimation for Correlation Spectroscopy in 3D (MTECS3D) v0.1

This innovative software estimates rotational diffusion coefficients of particles from X-ray photon correlation spectroscopy (XPCS) data of monodispersed particle systems. It is the first method capable of extracting rotational diffusion information from three-dimensional particle systems using XPCS. Using the angular-temporal cross-correlation of the XPCS images, this software is able to estimate the rotational diffusion coefficients with only a few percent relative errors while requiring minimal prior knowledge of particle structures. This software enhances XPCS analysis capabilities, allowing researchers to study translational and rotational Brownian dynamics of particles in suspension across various temporal and spatial scales.

Hu, Zixi↗

Measurements of Turbulence Attenuation by a Dilute Dispersion of Solid Particles in Homogeneous Isotropic Turbulence

This research addresses turbulent gas flows laden with fine solid particles at sufficiently large mass loading that strong two-way coupling occurs. By two-way coupling we mean that the particle motion is governed largely by the flow, while the particles affect the gas-phase mean flow and the turbulence properties. Our main interest is in understanding how the particles affect the turbulence. Computational techniques have been developed which can accurately predict flows carrying particles that are much smaller than the smallest scales of turbulence. Also, advanced computational techniques and burgeoning computer resources make it feasible to fully resolve very large particles moving through turbulent flows. However, flows with particle diameters of the same order as the Kolmogorov scale of the turbulence are notoriously difficult to predict. Some simple flows show strong turbulence attenuation with reductions in the turbulent kinetic energy by up to a factor of five. On the other hand, some seemingly similar flows show almost no modification. No model has been proposed that allows prediction of when the strong attenuation will occur. Unfortunately, many technological and natural two-phase flows fall into this regime, so there is a strong need for new physical understanding and modeling capability. Our objective is to study the simplest possible turbulent particle-laden flow, namely homogeneous, isotropic turbulence with a uniform dispersion of monodisperse particles. We chose such a simple flow for two reasons. First, the simplicity allows us to probe the interaction in more detail and offers analytical simplicity in interpreting the results. Secondly, this flow can be addressed by numerical simulation, and many research groups are already working on calculating the flow. Our detailed data can help guide some of these efforts. By using microgravity, we can further simplify the flow to the case of no mean velocity for either the turbulence or the particles. In fact the addition of gravity as a variable parameter may help us to better understand the physics of turbulence attenuation. The experiments are conducted in a turbulence chamber capable of producing stationary or decaying isotropic turbulence with nearly zero mean flow and Taylor microscale Reynolds numbers up to nearly 500. The chamber is a 410 mm cubic box with the corners cut off to make it approximately spherical. Synthetic jet turbulence generators are mounted in each of the eight corners of the box. Each generator consists of a loudspeaker forcing a plenum and producing a pulsed jet through a 20 mm diameter orifice. These synthetic jets are directed into ejector tubes pointing towards the chamber center. The ejector tubes increase the jet mass flow and decrease the velocity. The jets then pass through a turbulence grid. Each of the eight loudspeakers is forced with a random phase and frequency. The resulting turbulence is highly Isotropic and matches typical behavior of grid turbulence. Measurements of both phases are acquired using particle image velocimetry (PIV). The gas is seeded with approximately 1 micron diameter seeding particles while the solid phase is typically 150 micron diameter spherical glass particles. A double-pulsed YAG laser and a Kodak ES-1.0 10-bit PIV camera provide the PIV images. Custom software is used to separate the images into individual images containing either gas-phase tracers or large particles. Modern high-resolution PIV algorithms are then used to calculate the velocity field. A large set of image pairs are acquired for each case, then the results are averaged both spatially and over the ensemble of acquired images. The entire apparatus is mounted in two racks which are carried aboard NASA's KC-135 Flying Microgravity Laboratory. The rack containing the turbulence chamber, the laser head, and the camera floats freely in the airplane cabin (constrained by competent NASA personnel) to minimize g-jitter.

Eaton, John↗

Large-size monodisperse latexes as a commercial space product

Proposed spacelab production of large-size (2-40 micron diameter) monodispersed latexes is discussed. Explanations are given for the present lack of monodisperse particles in this size range. The four main topics discussed are: (1) the potential uses of these large particle size latexes, (2) why it is necessary for the particles to have a very narrow size distribution, (3) why large amounts of these monodisperse latexes are needed, and (4) why it is necessary to go to microgravity to prepare these latexes.

Kornfeld, D. M.↗

Particle charge distributions in the effluent of a flow-through atmospheric pressure low temperature plasma

Atmospheric pressure low-temperature plasmas are often utilized to perform particle synthesis, treatment, and removal. It is well-known that dust particles are highly negatively charged in these plasmas; however, little is known about dust particle charging behavior as particles leave the plasma volume and pass through the spatial afterglow region. In this work, monodisperse particles of various sizes and work functions were introduced into an atmospheric pressure radiofrequency capacitively coupled flow-through plasma. Dust particle electrical mobility distributions downstream of the flow-through plasma were measured utilizing a differential mobility analyzer in conjunction with a condensation particle counter at various gas flow velocities. Charge distributions were determined from the measured electrical mobility distributions. Experiments confirm that particles become less negatively charged, and even net-positively charged after leaving the plasma volume, with a distribution that follows a shifted Boltzmann charge distribution. Additionally, particle charge in the effluent of the flow-through plasma is negligibly dependent on work function but highly size and flow velocity dependent. Larger particles were shown to have a higher magnitude of charge under all studied conditions; however, particle polarity was switchable by varying gas flow velocity. The charging dynamics were simulated utilizing a constant number Monte Carlo model that accounts for electron temperature decay and the transition from ambipolar to free diffusion of electrons and ions in the spatial afterglow. Simulation results also suggest that, at the same flow velocity, larger particles obtain a greater magnitude of charge, negative or positive. Furthermore, the decrease in electron mobility and the difference between ion and electron convective loss rates create an ion-rich region in the plasma effluent that promotes ion–particle collisions and drives particle charge removal and even reversal of polarity. Larger particles more favorably collide with energetic species in these environments, which results in higher charge states.

atmospheric pressure low temperature plasma↗

Sizing Accuracy of Low-Cost Optical Particle Sensors Under Controlled Laboratory Conditions

Low-cost particulate matter sensors have seen increased use for monitoring at personal and local levels due to their affordability, ease of operation, and high time resolution. However, the quality of data reported by these sensors can be questionable, and a thorough evaluation of their performance is necessary. This study evaluated the particle sizing accuracy of several commonly used optical sensors, including the Alphasense optical particle counter (OPC), TSI DustTrak DRX aerosol monitor, Plantower PMS5003 sensor, and Sensirion SPS30 sensor, using laboratory-generated monodisperse particles. The OPC and DRX agreed partially with reference instruments and showed promise in detecting coarse-size particles. However, the PMS5003 and SPS30 did not correctly size fine and coarse particles. Furthermore, their reported mass distributions do not directly correspond to their number distribution. Despite these limitations, field measurements involving a dust storm period showed that the SPS30 correlated reasonably well with reference instruments for both PM2.5 and PM10, though the regression slopes differed significantly. These findings underscore the need for caution when interpreting data from low-cost optical sensors, particularly for coarse particles. Recommendations for improving the performance of these sensors are also provided.

Gautam, Prakash↗

Comparison of UNL laser imaging and sizing system and a phase/Doppler system for analyzing sprays from a NASA nozzle

Aerosol spray characterization was done using a P/DPA and a laser imaging/video processing system on a NASA MOD-1 air-assist nozzle being evaluated for use in aircraft icing research. Benchmark tests were performed on monodispersed particles and on the NASA MOD-1 nozzle under identical laboratory operating conditions. The laser imaging/video processing system and the P/DPA showed agreement on calibration tests in monodispersed aerosol sprays of + or - 2.6 microns with a standard deviation of + or - 2.6 microns. Tests were performed on the NASA MOD-1 nozzle on the centerline and radially at one-half inch increments to the outer edge of the spray plume at a distance two feet (0.61 m) downstream from the exit of the nozzle. Comparative results at two operating conditions of the nozzle are presented for the two instruments. For the first case, the deviation in arithmetic mean diameters determined by the two instruments was in a range of 0.1 to 2.8 microns, and the deviation in Sauter mean diameters varied from 0 to 2.2 microns. Operating conditions in the second case were more severe which resulted in the arithmetic mean diameter deviating from 1.4 to 7.1 microns and the deviation in the Sauter mean diameters ranging from 0.4 to 6.7 microns.

Alexander, Dennis R.↗

Comparison of UNL laser imaging and sizing system and a phase Doppler system for analyzing sprays from a NASA nozzle

Research was conducted on characteristics of aerosol sprays using a P/DPA and a laser imaging/video processing system on a NASA MOD-1 air assist nozzle being evaluated for use in aircraft icing research. Benchmark tests were performed on monodispersed particles and on the NASA MOD-1 nozzle under identical lab operating conditions. The laser imaging/video processing system and the P/DPA showed agreement on a calibration tests in monodispersed aerosol sprays of + or - 2.6 micron with a standard deviation of + or - 2.6 micron. Benchmark tests were performed on the NASA MOD-1 nozzle on the centerline and radially at 0.5 inch increments to the outer edge of the spray plume at a distance 2 ft downstream from the exit nozzle. Comparative results at two operation conditions of the nozzle are presented for the two instruments. For the 1st case studied, the deviation in arithmetic mean diameters determined by the two instruments was in a range of 0.1 to 2.8 micron, and the deviation in Sauter mean diameters varied from 0 to 2.2 micron. Severe operating conditions in the 2nd case resulted in the arithmetic mean diameter deviating from 1.4 to 7.1 micron and the deviation in the Sauter mean diameters ranging from 0.4 to 6.7 micron.

Alexander, Dennis R.↗

Performance Evaluation of Particle Sampling Probes for Emission Measurements of Aircraft Jet Engines

Considerable attention has been recently received on the impact of aircraft-produced aerosols upon the global climate. Sampling particles directly from jet engines has been performed by different research groups in the U.S. and Europe. However, a large variation has been observed among published data on the conversion efficiency and emission indexes of jet engines. The variation results surely from the differences in test engine types, engine operation conditions, and environmental conditions. The other factor that could result in the observed variation is the performance of sampling probes used. Unfortunately, it is often neglected in the jet engine community. Particle losses during the sampling, transport, and dilution processes are often not discussed/considered in literatures. To address this issue, we evaluated the performance of one sampling probe by challenging it with monodisperse particles. A significant performance difference was observed on the sampling probe evaluated under different temperature conditions. Thermophoretic effect, nonisokinetic sampling and turbulence loss contribute to the loss of particles in sampling probes. The results of this study show that particle loss can be dramatic if the sampling probe is not well designed. Further, the result allows ones to recover the actual size distributions emitted from jet engines.

Lee, Poshin↗

Rainbow Fourier Transform

We present a novel technique for remote sensing of cloud droplet size distributions. Polarized reflectances in the scattering angle range between 135deg and 165deg exhibit a sharply defined rainbow structure, the shape of which is determined mostly by single scattering properties of cloud particles, and therefore, can be modeled using the Mie theory. Fitting the observed rainbow with such a model (computed for a parameterized family of particle size distributions) has been used for cloud droplet size retrievals. We discovered that the relationship between the rainbow structures and the corresponding particle size distributions is deeper than it had been commonly understood. In fact, the Mie theory-derived polarized reflectance as a function of reduced scattering angle (in the rainbow angular range) and the (monodisperse) particle radius appears to be a proxy to a kernel of an integral transform (similar to the sine Fourier transform on the positive semi-axis). This approach, called the rainbow Fourier transform (RFT), allows us to accurately retrieve the shape of the droplet size distribution by the application of the corresponding inverse transform to the observed polarized rainbow. While the basis functions of the proxy-transform are not exactly orthogonal in the finite angular range, this procedure needs to be complemented by a simple regression technique, which removes the retrieval artifacts. This non-parametric approach does not require any a priori knowledge of the droplet size distribution functional shape and is computationally fast (no look-up tables, no fitting, computations are the same as for the forward modeling).

Alexandrov, Mikhail D.↗

Direct numerical simulations of activation and deactivation in turbulent atmospheric clouds

Significant knowledge gaps remain in our understanding of turbulence–cloud–aerosol interactions in the Earth's atmosphere, and direct numerical simulation (DNS) has increasingly become an indispensable tool to fill such critical knowledge gaps. Here, this study is an extension of our previous DNS model [Gao et al., J. Geophys. Res.: Atmos., 123(4), 2194–2214 (2018)], with a focus on the activation of aerosol particles into cloud droplets and deactivation of cloud droplets into aerosol particles in a microscale cloud environment. The effects of turbulence intensity, particle curvature, and solute, as well as the initial distributions of the aerosol particles (monodisperse or polydisperse) are investigated. The governing equations for the flow of air, temperature, and water vapor mixing ratio are solved numerically in the Eulerian fashion, assuming homogeneous and isotropic turbulence. The dynamics of the aerosol and cloud particles are calculated with the Lagrangian particle tracking method. The results show that the deviations of the thermodynamic variables from their respective means are significantly reduced, the activation process appears to be delayed, and the deactivation process occurs more rapidly, as the turbulence intensity is increased. The inclusion of particle curvature and solute effects, as well as polydispersity, tends to retard the activation of aerosols into cloud droplets. It is also observed that fluctuations in supersaturation broaden the spread of particle radii, and the broadening is followed by a narrowing as turbulent homogenization reduces thermodynamic fluctuations over time.

54 ENVIRONMENTAL SCIENCES↗

High-purity silica reflecting heat shield development

A high-purity, fused-silica reflecting heat shield for the thermal protection of outer-planet probes was developed. Factors that strongly influence the performance of a silica heat shield were studied. Silica-bonded silica configurations, each prepared by a different technique, were investigated and rated according to its relative merits. Slip-casting was selected as the preferred fabrication method because it produced good reflectivity and good strength, and is relatively easy to scale up for a full-size outer-planet probe. The slips were cast using a variety of different particle sizes: continuous particle-size slips; monodisperse particle-size slips; and blends of monodisperse particle-size slips were studied. In general, smaller particles gave the highest reflectance. The monodisperse slips as well as the blend slips gave a higher reflectance than the continuous particle-size slips. An upgraded and fused natural quartz was used to study the effects of microstructure on reflectance and as the baseline to ascertain the increase in reflectance obtained from using a higher-purity synthetic material.

Congdon, W. M.↗

NCSU HTDMA data

NCSU HTDMA data Data Level b1: QC checks applied to measurements Data Format: CSV Description: See "instrument description Site: Houston, TX; Tracking Aerosol Convection interactions ExpeRiment (HOU) Location: Houston, TX; AMF1 (main site for TRACER) Facility Code: M1 Category: Aerosol Properties Data Type: PI Data Source Instrument/Data: Humidified Tandem Differential Mobility Analyzer; 2 Differential Mobility Analyzers (DMA1 and DMA2). Start Date: 2022-06-01 End Date: 2022-09-26 Contact PI: Markus Petters (mdpetter@ncsu.edu) Funding Source: DOE ASR award US Department of Energy, Office of Science, Biological and Environment Research (grant no. DE-SC 0021074) Instrument description The NCSU HTDMA was operated at a sheath-to-sample flow ratio of 5:1 L min−1. The HTDMA was configured to measure hygroscopic growth factors of dry particles with mobility diameters of D = 15, 20, 30, 40, and 50 nm at RH ~ 70%. A complete cycle for all diameters took ~30 minutes. A sample line brought aerosol inside the trailer at 2.5 L min-1, where it was distributed between NCSU RDMA (1.5 L min-1) and NCSU HTDMA (1 L min-1) lines. The sample line was dried with three silica-gel driers in series, and then neutralized with X-ray neutralizer. The sample line entered DMA1 (operated as an electrostatic classifier). Monodisperse particles with certain fractions were humidified with temperature controlled Nafion membrane immersed in water before entering DMA2 (operated in scanning mobility particle sizer). Please contact mdpetter@ncsu.edu for further information.

54 ENVIRONMENTAL SCIENCES↗

Concentration and Velocity Gradients in Fluidized Beds

In this work we focus on the height dependence of particle concentration, average velocity components, fluctuations in these velocities and, with the flow turned off, the sedimentation velocity. The latter quantities are measured using Particle Imaging Velocimetry (PIV). The PIV technique uses a 1-megapixel camera to capture two time-displaced images of particles in the bed. The depth of field of the imaging system is approximately 0.5 cm. The camera images a region with characteristic length of 2.6 cm for the small particles and 4.7 cm. for the large particles. The local direction of particle flow is determined by calculating the correlation function for sub-regions of 32 x 32 pixels. The velocity vector map is created from this correlation function using the time between images (we use 15 to 30 ms). The software is sensitive variations of 1/64th of a pixel. We produce velocity maps at various heights, each consisting of 3844 velocities. We break this map into three vertical zones for increased height information. The concentration profile is measured using an expanded (1 cm diameter) linearly polarized HeNe Laser incident on the fluidized bed. A COHU camera (gamma=1, AGC off) with a lens and a polarizer images the transmitted linearly polarized light to minimize the effects of multiply scattered light. The intensity profile (640 X 480 pixels) is well described by a Gaussian fit and the height of the Gaussian is used to characterize the concentration. This value is compared to the heights found for known concentrations. The sedimentation velocity is estimated using by imaging a region near the bottom of the bed and using PIV to measure the velocity as a function of time. With a nearly uniform concentration profile, the time can be converted to height information. The stable fluidized beds are made from large pseudo-monodisperse particles (silica spheres with radii (250-300) microns and (425-500) microns) dispersed in a glycerin/water mix. The Peclet number is sufficiently large that Brownian motion of the particles can be ignored and the Reynolds number sufficiently small that particle inertia is negligible. A packed particle bed is used to randomize and disperse the flowing fluid introduced by a peristaltic pump. The bed itself is a rectangular glass cell 8 cm wide (x), 0.8 cm deep and a height of 30.5 cm (z). The depth of field of the camera is approximately 0.5 cm so depth information is averaged. Over flow fluid is returned to the reservoir making a closed loop system. In these experiments the particles form a sediment approximately 5.7 cm high with the pump off and expand to 22 cm with the pump on. For the smaller particles the pump velocity is .5 millimeters per second and 1.1 millimeters per second for the large particles. At this concentration the bed has a very well defined top where particle concentration rapidly drops to zero.

McClymer, James P.↗

Dynamic, Adaptive, Systems and Materials: Complex, Simple and Emergent Behaviors

This program has been funded by DoE/BES for twenty years. It has moved into and out of various subjects as it has developed, but it has retained its focus on complexity and complex systems. The project has evolved in the following way: Self-Assembly and Biomimetic Self-Assembly: All self-assembling systems depend upon a minimum of two types of interaction: a repulsion and an attraction. For the familiar molecular systems, attractive interactions are typically hydrogen bonds and electrostatic interactions. Repulsive interactions include steric effects, hydrophobic effects (in biological systems), and charge-charge repulsion. We have expanded this repertoire to include surface interactions, magnetic interactions, and others. I list these systems in the order in which we have explored them: i) A key emphasis in current work is in understanding how the movement of ions in a magnetic field (the Lorentz effect) interacts with catalytic systems. We have demonstrated that an acceleration in rate of reduction of CO 2 to CO can be accomplished by applying an external magnetic field. This acceleration is largely due to the application of the Lorentz effect on mass transport at the catalyst’s surface. ii) We have also extensively explored the influence of electrostatics, as exhibited in self-assembling systems, by tribocharging. iii) Another key system involves surface tension effects; examples include interactions between heavy particles floating at a liquid-air interface, and interacting by changes in surface area; interactions of bubbles and bubble rafts, behaviors of bubble trains in microfluidic networks, and behaviors of microorganisms in constraining environments. iv) This work has intentionally de-emphasized biological systems; but it does include some work on protein-ligand interactions and interactions among microorganisms. v) We have also explored applications of some of these effects, these explorations include bubble rafts as diffraction gratings, exploration of the structures that can be obtained by tribocharging and uses of these structures in exploring nucleation and melting of crystals. vi) Although not a major focus of this work, several other topics have emerged and offer opportunities for future work. These include the behavior of bubble trains and bubble rafts in microfluidic systems. A particularly interesting example is the formation of bubble trains that repeat in the alteration of large and small bubbles according to rules we do not presently understand, but are uniquely large-period oscillating systems. These systems offer a new route into understanding the instabilities of the type represented by oscillations. vii) We have also begun exploratory projects on magnetic levitation (especially to determine molecular density), and information storage (in molecules). Magnetic Levitation: Self-assembling and biomimetic systems require both attraction and repulsion. We have used electrostatics (tribocharging), interfacial free-energies (surface tension and related forces) and others. Potential uses include reconfigurable diffraction gratings and liquid lenses; exploration of mechanisms in tribocharging; tunneling in EGaIn junctions; and bubble trains (especially in micro-fluidic systems). Examples of systems representing these topics is included in the following papers: Complexity: Disks rotating at a water-air interface; Benard-Marangoni effects; Vortex-Crystals from spinning magnetic disks (Marangoni effects); EGaIn Electrode to study quantum tunneling; Self-Assembly of electrostatically-charged metallic spheres (electrets); Dynamically reconfigurable lens; Using computational designs of ligands for enzymes; Electrostatic self-assembly by tribocharging; Monodisperse bubble trains in microchannel systems; Inverted dripping faucet; Flames; Printing of micro-organisms to regenerate the “ink” of printing device; Using micro-organisms to move loads (“microoxen”); Motion of bacterial swarms near surfaces; Making monodisperse particles in microfluidic systems; Coding/decoding of information stored in droplet trains in microfluidic networks; Magnetic levitation; and Information storage. i) Tribocharging. The change in focus of this work on electrets from the fundamentals of charging to applications of these materials in studying self-assembly using electrostatic interactions. ii) Bubbles in Microchannels. The realization that systems of bubbles in microchannels represented a major opportunity to study complexity in a very tractable system, and the development of a semi-quantitative theory of this subject. iii) Flames. The growth of “flames” remains an exploratory subject for the research, although their currently relatively little active work involving it ongoing. iv) Systems with Microorganisms. The removal of work in biological systems from this project. Based on work supported in this program, we now have a significant project on the development of microfluidic tools for studying C. elegans (a nematode), but this work was not appropriate for a program focused on complexity, and we developed separate support for it. (It is, however, an example of successful seeding of a new area by BES.) The work on electrets has gone through a period in which a part of the program was the subject of a MURI; the focus of this work was to develop materials that did not charge electrostatically on friction or contact. The MURI is now over, and the work on dynamic self-assembly (supported by BES) is the major focus. “Flames” has also enjoyed synergistic support, in terms of a project supported by DARPA on flame suppression (in the absence of extinguishing agents, using acoustic and electrostatic interactions). This work was helpful in understanding some of the basics of flames, but is entirely distinct from the BES focus in complexity. A growing interest is in the Lorentz effect. The Lorentz effect is the force exerted on charged particles (electrons, ions, charged molecules) when they move through a perpendicular magnetic field. The Lorentz effect is almost ubiquitous in modern technology: examples of applications include electric motors, dynamos, cathode ray tubes, many batteries, and most systems that control electrical currents with magnetic forces. We have begun to explore the Lorentz effect in electrochemical systems and heterogeneous catalytic systems involving charged organic species and inorganic ions. This work is still at an early stage, but initial studies that Lorentz effects can be large when ions move through magnetic fields, or magnetic fields move in the presence of ions.

36 MATERIALS SCIENCE↗

Pulse height response of an optical particle counter to monodisperse aerosols

The pulse height response of a right angle scattering optical particle counter has been investigated using monodisperse aerosols of polystyrene latex spheres, di-octyl phthalate and methylene blue. The results confirm previous measurements for the variation of mean pulse height as a function of particle diameter and show good agreement with the relative response predicted by Mie scattering theory. Measured cumulative pulse height distributions were found to fit reasonably well to a log normal distribution with a minimum geometric standard deviation of about 1.4 for particle diameters greater than about 2 micrometers. The geometric standard deviation was found to increase significantly with decreasing particle diameter.

Wilmoth, R. G.↗