Search NASA⌕ Search

SEARCH · Search NASA

Results for “multiplexed sensing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

All-digital Sensor System for Distributed Downhole Pressure Monitoring in Unconventional Fields

This project developed and validated (through field tests) a new low-cost all-digital pressure sensing technology for in situ distributed downhole pressure monitoring in unconventional oil and gas (UOG) fields. The all-digital sensing technology uses a built-in non-electric analog-to-digital converter (ADC) to transform the pressure information into a combination of binary (ON/OFF) states. As such, the system does not need downhole electronics for signal conditioning and telemetry. The all-digital sensors can be remotely logged over a long distance, and many sensors can be multiplexed for distributed sensing. Based on a review of unconventional wells in the Lower 48 states, the specification of the sensor is to measure pressure up to 69 MPa (10,000 psi) and temperature up to 250°C. A sensor with a helical bourdon sensing element and a digital signal decoder of 50 mm diameter and 109 mm length was constructed. The helical bourdon sensing element was made of 304L stainless steel and filled with motor oil. The digital converter was made up of 8 digital reading pads constructed of high-temperature epoxy with conductive inserts made of stainless steel. The sensor had a linear response to pressure with an accuracy of 0.14 MPa (20 psi). To withstand the high pressure, the sensor was enclosed in a stainless-steel pressure housing with a wall thickness of 5.5 mm, a diameter of 73 mm, and a length of 724 mm. In the laboratory tests, the sensor exhibited no temperature-related effects on the results. The sensor did not show drift over a 14-day test period at elevated pressure. A field test was conducted where the sensor was deployed in a test wellbore at the Quest drilling test facility to a depth of 0 feet over three weeks. The sensor was attached to the production rods, along with a downhole reference sensor of PPS27 type, which is a permanent downhole monitoring system. During the testing phase, the test well annular blow-out preventer was closed, and the well was pressurized at the surface to 11 MPa (1600 psi). The sensor read the elevated bottom hole pressure of 1500 psi. A multiplexing unit was created for the sensor to deploy multiple sensors on one data transmission line in a distributed approach. The multiplexing unit was tested in a simulated environment of 3048 m (10,000 ft) with five sensors distributed. The sensors were pressurized at different intervals. The multiplexed sensors recorded the correct pressure, and the multiplexing did not interfere with the readings. The proposed concept of an all-digital pressure sensor for harsh downhole environments was designed, manufactured, and tested in the laboratory and tested at the field to a up to 69 MPa and 250°C. This technology has high-temperature tolerance and has potential in downhole areas outside oil and gas, such as carbon capture and storage (CCS) and geothermal wells. The sensor concept has been proven in this project, but to create a commercially viable product, manufacturing a sensor with a smaller diameter needs to be performed.

02 PETROLEUM↗

TRANSENSOR: Transformer Real-time Assessment INtelligent System with Embedded Network of Sensors and Optical Readout. Final Report

Utilities across the world are wrestling with evolving market dynamics, population growth and climate change. Distributed Energy Resources (DERs) such as solar photovoltaics, distributed generators and energy storage systems are becoming important parts of the U.S. energy mix. These factors are driving an increasing need for low-cost grid asset monitoring. Aside from being costly, traditional utility monitoring systems are not sufficiently robust and do not provide real-time visibility into the condition of grid assets such as transformers. Lack of accurate real-time measurements on performance has resulted in the use of lagging indicators, such as oil sample analysis. To address this need, an innovative embedded optical sensing technology, Transformer Real-time Assessment Intelligent System (TRANSENSOR) was developed, validated and demonstrated in this project. To date, TRANSENSOR has focused on transformers but is extendable to other grid assets. In addition to the technology being embedded into new transformers during manufacturing, a retrofit configuration that can be installed on existing transformers in the field was also developed. It is anticipated that the ability to retrofit existing transformers will help accelerate adoption of the underlying TRANSENSOR technology. Phase 1 of the project focused on laboratory development and qualification of the technology. Following iterations and exploration of relevant optical sensing modalities and multiplexed configurations of interest for the transformer environment, an effective candidate configuration was agreed upon, down-selected and custom-designed for embedding into General Electric (GE) network transformers. Two new GE 500 kilovolt ampere (kVA), 27 kilovolt (kV) distribution network transformers were built with embedded fiber-optic (FO) sensors and successfully qualified per industry standards at GE’s Shreveport, Louisiana facility during Phase 1 of the project. Following the successful completion of Phase 1, the team proceeded to Phase 2, which focused on a field demonstration of the technology. Over Phase 2, the first new GE transformer built with embedded fiber-optic sensors was installed in an above-ground cage and connected to the grid at Con Edison’s Astoria facility. A second transformer equipped with TRANSENSOR was installed in an underground vault. Additionally, an older (1982 year model) GE transformer in an above-ground cage was retrofitted with fiber- optic sensors and reconnected to the grid at ConEd’s facility. Analysis of data acquired from the sensors showed interesting correlations with transformer loading. Additionally, key events such as transformer low-voltage network connection, primary-side energizing, and a pressure loss event from an oil sampling were detected by the TRANSENSOR system. Online data processing/feature extraction algorithms for the second transformer in the underground vault detected key features and event alerts that were transmitted through a wireless 4G connection. The remote deployment concept showed promising results with data collection running for a total of 8 months across the three (3) GE transformers instrumented for the Phase 2 field demonstration. This sets the stage well for further development and commercialization.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Flexible organic integrated electronics for self-powered multiplexed ocular monitoring

Smart contact lens has drawn extensive research interests due to the noninvasive real-time detection of the human body to provide biomedical information for health management. However, it has been difficult to accurately measure the physiological signals in tears, and the use of external power source has also hindered the future applications. Here, we demonstrated an organic electrochemical transistor based multiplexed sensors self-powered by the organic solar cells (OSCs). The integrated device was fabricated via simple process including solution blade-coating and thermal evaporation. OSCs were optimized to provide optimal operation voltage for the sensors that exhibit semilog-linear response to the glucose and calcium ions in tear fluids without any peripheral circuits. The sensing signals can be transmitted to the laptop wirelessly through a near filed communication unit. This integrated self-powered multiplexed sensing device will provide real-time monitoring of the biomarkers in tears, prospected to be installed on the smart contact lens for the early detection and diagnosis of diabetes.

36 MATERIALS SCIENCE↗

Highly multiplexed design of an allosteric transcription factor to sense new ligands

Allosteric transcription factors (aTF) regulate gene expression through conformational changes induced by small molecule binding. Although widely used as biosensors, aTFs have proven challenging to design for detecting new molecules because mutation of ligand-binding residues often disrupts allostery. Here, we develop Sensor-seq, a high-throughput platform to design and identify aTF biosensors that bind to non-native ligands. We screen a library of 17,737 variants of the aTF TtgR, a regulator of a multidrug exporter, against six non-native ligands of diverse chemical structures – four derivatives of the cancer therapeutic tamoxifen, the antimalarial drug quinine, and the opiate analog naltrexone – as well as two native flavonoid ligands, naringenin and phloretin. Sensor-seq identifies biosensors for each of these ligands with high dynamic range and diverse specificity profiles. The structure of a naltrexone-bound design shows shape-complementary methionine-aromatic interactions driving ligand specificity. To demonstrate practical utility, we develop cell-free detection systems for naltrexone and quinine. Sensor-seq enables rapid and scalable design of new biosensors, overcoming constraints of natural biosensors.

59 BASIC BIOLOGICAL SCIENCES↗

Flexible Electronics toward Wearable Sensing

Wearable sensors play a crucial role in realizing personalized medicine, as they can continuously collect data from the human body to capture meaningful health status changes in time for preventive intervention. However, motion artifacts and mechanical mismatches between conventional rigid electronic materials and soft skin often lead to substantial sensor errors during epidermal measurement. Because of its unique properties such as high flexibility and conformability, flexible electronics enables a natural interaction between electronics and the human body. Here, we summarize our recent studies on the design of flexible electronic devices and systems for physical and chemical monitoring. Material innovation, sensor design, device fabrication, system integration, and human studies employed toward continuous and noninvasive wearable sensing are discussed. A flexible electronic device typically contains several key components, including the substrate, the active layer, and the interface layer. The inorganic-nanomaterials-based active layer (prepared by a physical transfer or solution process) is shown to have good physicochemical properties, electron/hole mobility, and mechanical strength. Flexible electronics based on the printed and transferred active materials has shown great promise for physical sensing. For example, integrating a nanowire transistor array for the active matrix and a conductive pressure-sensitive rubber enables tactile pressure mapping; tactile-pressure-sensitive e-skin and organic light-emitting diodes can be integrated for instantaneous pressure visualization. Such printed sensors have been applied as wearable patches to monitor skin temperature, electrocardiograms, and human activities. In addition, liquid metals could serve as an attractive candidate for flexible electronics because of their excellent conductivity, flexibility, and stretchability. Liquid-metal-enabled electronics (based on liquid-liquid heterojunctions and embedded microchannels) have been utilized to monitor a wide range of physiological parameters (e.g., pulse and temperature). Despite the rapid growth in wearable sensing technologies, there is an urgent need for the development of flexible devices that can capture molecular data from the human body to retrieve more insightful health information. We have developed a wearable and flexible sweat-sensing platform toward real-time multiplexed perspiration analysis. An integrated iontophoresis module on a wearable sweat sensor could enable autonomous and programmed sweat extraction. A microfluidics-based sensing system was demonstrated for sweat sampling, sensing, and sweat rate analysis. Roll-to-roll gravure printing allows for mass production of high-performance flexible chemical sensors at low cost. These wearable and flexible sweat sensors have shown great promise in dehydration monitoring, cystic fibrosis diagnosis, drug monitoring, and noninvasive glucose monitoring. Future work in this field should focus on designing robust wearable sensing systems to accurately collect data from the human body and on large-scale human studies to determine how the measured physical and chemical information relates to the individual's specific health conditions. Further research in these directions, along with the large sets of data collected via these wearable and flexible sensing technologies, will have a significant impact on future personalized healthcare.

47 OTHER INSTRUMENTATION↗

Epidermal Impedance Sensing Sheets for Precision Hydration Assessment and Spatial Mapping

This paper presents a class of hydration monitor that uses ultrathin, stretchable sheets with arrays of embedded impedance sensors for precise measurement and spatially multiplexed mapping. The devices contain miniaturized capacitive electrodes arranged in a matrix format, capable of integration with skin in a conformal, intimate manner due to the overall skin-like physical properties. These “epidermal” systems noninvasively quantify regional variations in skin hydration, at uniform or variable skin depths. Experimental results demonstrate that the devices possess excellent uniformity, with favorable precision and accuracy. Theoretical models capture the underlying physics of the measurement and enable quantitative interpretation of the experimental results. Furthermore, these devices are appealing for applications ranging from skin care and dermatology, to cosmetology and health/wellness monitoring, with the additional potential for combined use with other classes of sensors for comprehensive, quantitative physiological assessment via the skin.

42 ENGINEERING↗

Robust Ceramic Coaxial Cable Down-Hole Sensors for Long-Term In Situ Monitoring of Geologic CO 2 Injection and Storage

Energy generation by use of fossil fuels produces large volumes of CO 2 and other greenhouse gases, whose accumulation in the atmosphere is widely seen as undesirable. CO 2 Capture followed by sequestration has been identified as the solution. Subsurface geologic formations offer a potential location for long-term storage of CO 2 because of their requisite size. Unfortunately, the inaccessibility and complexity of the subsurface, the wide range of scales of variability, and the coupled nonlinear processes, impose tremendous challenges to determine the transport and predict the fate of the stored CO 2 . Among the various monitoring approaches, in situ down-hole monitoring of the various state parameters provides critical and direct data points that can be used to validate the models, optimize the injection, detect leakage and track the CO 2 plume. However, down-hole sensors that can withstand the harsh conditions and operate over decades of the project lifecycle remain unavailable. Given that the widespread of carbon capture and storage will be the necessity and reality in the future, fundamental and applied research is required to address the significant challenges and technological gaps in lack of long-term reliable down-hole sensors This project focused on the development and demonstration of a novel, low-cost, distributed, robust ceramic coaxial cable sensor platform for in situ down-hole monitoring of geologic CO 2 injection and storage with high spatial and temporal resolutions. The coaxial cable Fabry-Perot interferometer (CCFPI) has been studied as a general sensor platform for in situ, long-term, measurement of temperature, pressure and strain, which are critical to CO 2 injection and storage. A novel signal processing scheme has been developed and demonstrated for dense multiplexing of the sensors for low-cost distributed sensing with high spatial resolution. The developed temperature, pressure and strain sensors have been extensively tested under laboratory conditions that are similar to the downhole CO 2 storage environment, showing excellent capability for in situ monitoring the various parameters that are important to model, optimize the injection, detect leakage and track the CO 2 plume. In addition, the interactions between the sensor datum and the geological models have been investigated in details for the purposes of model validation, guiding sensor installation/placement, enhancement of model prediction capability and optimization of the injection processes. This project has resulted in the successful development of new ceramic coaxial cable based sensor systems that can monitor directly the changes in pressure, temperature, and strain caused by increased reservoir pressure and reduced reservoir temperature due to the supercritical CO 2 injection. Integrated with geological models, the sensors and measurement data can improve the possibility to identify plume movement and leakage in the cap rock and wells with higher precision and more accuracy. The low cost, ease of deployment, small size and dense multiplexing features of the new sensing technology will allow a large number of sensors to be deployed to address the objective to demonstrate that 99% of the CO 2 remains in the injection zone.

01 COAL, LIGNITE, AND PEAT↗

Application of Frequency Division Multiplexing and Neural Networks in the Operation and Diagnosis of the Stator Current and Shaft Position Sensors Used in Electric/Hybrid Vehicles

Fast, precise and robust sensing of currents and motor shaft angle is essential for the excellent performance of electric and hybrid vehicles (EV/HEV). Multiplexing techniques are commonly applied in data acquisition systems (DAQs) to digitize the signals sensed in EV/HEV drives. Frequency-division multiplexing (FDM) applied to get the signals from current sensors and resolver angular position sensor has advantages over conventional multiplexing approaches. However, problems such as aging and mechanical imperfections distort the outputs of those sensors, producing measurement errors of the angular position and currents. Conventional techniques designed to compensate for those errors cannot be applied in signals multiplexed in frequency. This paper proposes online techniques to detect and compensate for the distortions in the resolver sensor and current sensors. The demultiplexing process was adjusted to allow distortion detection and compensation. An auto-associative neural network (ANN) compensates for the current measurement error, while an energy-based technique is applied to compensate for the distortions in the resolver outputs. The obtained results show that the distortions were compensated, allowing a more accurate estimation of stator currents and angular position when FDM is applied in EV/HEV DAQs.

Pereira Pinto, Joao↗

Physical and Chemical Sensing With Electronic Skin

This paper reviews current progress on flexible and stretchable transistors and sensors for the next-generation multiplex electronics (commonly referred to as 'electronics skin' or 'e-skin') that is capable of simultaneous detection of multiple information from a variety of surfaces including human skin. Flexible chemical sensors for sweat analysis as well as physical sensors for detecting tactile force, bending, and temperature will be discussed, with emphasis on materials, detection mechanisms, and device demonstration to realize multiplex human-interactive devices. System integration enabling the real-time monitoring of health conditions is also demonstrated as a proof of concept. Finally, perspectives on e-skin for moving toward realizing practical wearable electronics in the market are discussed. This paper targets the translation of the nano- and flexible technologies from academic innovations to industrial practical applications with high-impact breakthroughs.

42 ENGINEERING↗

Total Internal Reflection of Two Lasers in a Single Planar Optical Waveguide

Multiplex biomarker quantitation is ideal for tracking the progression of a disease, but sensitive, specific, and quantitative multiplex biosensing remains challenging. We achieved total internal reflection with two lasers in a single planar optical waveguide by coupling 532 nm laser light into the diffraction grating of a waveguide and 635 nm laser light directly into the thin film of the same waveguide. We confirmed that the evanescent fields generated in the waveguide can excite two fluorescent dyes (Alexa Fluor 532 and Alexa Fluor 647) held to the surface of the waveguide through biotin-streptavidin chemistry. This sensing concept holds significant potential as a platform for multiplex biomarker detection.

47 OTHER INSTRUMENTATION↗

Scalable Parallel Measurement of Individual Nitrogen-Vacancy Centers

The nitrogen-vacancy (NV) center in diamond is a solid-state spin defect that has been widely adopted for quantum sensing and quantum information processing applications. Typically, experiments are performed either with a single isolated NV center or with an unresolved ensemble of many NV centers, resulting in a trade-off between measurement speed and spatial resolution or control over individual defects. In this work, we introduce an experimental platform that bypasses this trade-off by addressing multiple optically resolved NV centers in parallel. We perform charge- and spin-state manipulations selectively on multiple NV centers from within a larger set, and we manipulate and measure the electronic spin states of over 100 NV centers in parallel. We show that the high signal-to-noise ratio of the measurements enables the detection of shot-to-shot pairwise correlations between the spin states of 108 NV centers, corresponding to the simultaneous measurement of 5778 unique correlation coefficients. We discuss how our platform can be scaled to parallel experiments with thousands of individually resolved NV centers. These results enable parallelized high-throughput sensing experiments that retain the spatial resolution of single defects and will, thereby, help to unlock advances in applications such as single-molecule NMR and characterization of integrated circuits. In addition, our approach to multiplexing provides a natural platform for the application of recently developed correlated sensing techniques.

NV centers↗

Label-Free Anti-Brownian Trapping of Single Nanoparticles in Solution

Today, biomolecular nanoparticles are prevalent as diagnostic tools and molecular delivery carriers, and it is particularly useful to examine individuals within a sample population to quantify the variations between objects and directly observe the molecular dynamics involving these objects. Using interferometric scattering as a highly sensitive label-free detection scheme, we recently developed the interferometric scattering anti-Brownian electrokinetic (ISABEL) trap to hold a single nanoparticle in solution for extended optical observation. In this perspective, we describe how we implemented this trap, how it extends the capabilities of previous ABEL traps, and how we have begun to study individual carboxysomes, a fascinating biological carbon fixation nanocompartment. By monitoring single nanocompartments for seconds to minutes in the ISABEL trap using simultaneous interferometric scattering and fluorescence spectroscopy, we have demonstrated single-compartment mass measurements, cargo-loading trends, and redox sensing inside individual particles. These experiments benefit from rich multiplexed correlative measurements utilizing both scattering and fluorescence with many exciting future capabilities within reach.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Distributed Fiber Optic Gas Sensing for Harsh Environment

This report summarizes work to develop a novel distributed fiber-optic micro-sensor that is capable of detecting common fossil fuel gases in harsh environments. During the 32-month research and development (R&D) program, GE Global Research successfully synthesized sensing materials using two techniques: sol-gel based fiber surface coating and magnetron sputtering based fiber micro-sensor integration. Palladium nanocrystalline embedded silica matrix material (nc-Pd/Silica), nanocrystalline palladium oxides (nc-PdO{sub x}) and palladium alloy (nc-PdAuN{sub 1}), and nanocrystalline tungsten (nc-WO{sub x}) sensing materials were identified to have high sensitivity and selectivity to hydrogen; while the palladium doped and un-doped nanocrystalline tin oxide (nc-PdSnO{sub 2} and nc-SnO{sub 2}) materials were verified to have high sensitivity and selectivity to carbon monoxide. The fiber micro-sensor comprises an apodized long-period grating in a single-mode fiber, and the fiber grating cladding surface was functionalized by above sensing materials with a typical thickness ranging from a few tens of nanometers to a few hundred nanometers. GE found that the morphologies of such sensing nanomaterials are either nanoparticle film or nanoporous film with a typical size distribution from 5-10 nanometers. nc-PdO{sub x} and alloy sensing materials were found to be highly sensitive to hydrogen gas within the temperature range from ambient to 150 C, while nc-Pd/Silica and nc-WO{sub x} sensing materials were found to be suitable to be operated from 150 C to 500 C for hydrogen gas detection. The palladium doped and un-doped nc-SnO{sub 2} materials also demonstrated sensitivity to carbon monoxide gas at approximately 500 C. The prototyped fiber gas sensing system developed in this R&D program is based on wavelength-division-multiplexing technology in which each fiber sensor is identified according to its transmission spectra features within the guiding mode and cladding modes. The interaction between the sensing material and fossil fuel gas results in a refractive index change and optical absorption in the sensing layer. This induces mode coupling strength and boundary conditions changes and thereby shifts the central wavelengths of the guiding mode and cladding modes propagation. GE's experiments demonstrated that such an interaction between the fossil fuel gas and sensing material not only shifts the central wavelengths of the guide mode and cladding modes propagation, but also alters their power loss characteristics. The integrated fiber gas sensing system includes multiple fiber gas sensors, fiber Bragg grating-based temperature sensors, fiber optical interrogator, and signal processing software.

08 HYDROGEN↗