Search NASA⌕ Search

SEARCH · Search NASA

Results for “national ignition facility”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Alpha-heating analysis of burning plasma and ignition experiments on the National Ignition Facility

A recent experiment conducted on the National Ignition Facility (NIF) described in the study by Abu-Shawareb et al. achieved a fusion yield output of 1.3 MJ from ~ 220 kJ of x-ray energy absorbed by the capsule, demonstrating remarkable progress in the field of laser driven inertial confinement fusion. In the study by A. R. Christopherson [“Effects of charged particle heating on the hydrodynamics of inertially confined plasmas,” Ph.D. thesis (2020)], the plasma conditions needed to claim the onset of ignition and burn propagation were outlined and multiple criterion were provided to assess progress in inertial fusion experiments. In this work, we modify the metrics from A. R. Christopherson to accurately calculate performance metrics for indirect-drive experiments on the NIF. We also show that performance metric trends observed in NIF data are consistent with theory and simulations. This analysis indicates that all the identified criterion for ignition and burn propagation have been exceeded by experiment 210 808.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental achievement and signatures of ignition at the National Ignition Facility

An inertial fusion implosion on the National Ignition Facility, conducted on August 8, 2021 (N210808), recently produced more than a megajoule of fusion yield and passed Lawson's criterion for ignition [Phys. Rev. Lett. 129, 075001 (2022)]. Here we describe the experimental improvements that enabled N210808 and present the first experimental measurements from an igniting plasma in the laboratory. Ignition metrics like the product of hot-spot energy and pressure squared, in the absence of self-heating, increased by ~ 35%, leading to record values and an enhancement from previous experiments in the hot-spot energy (~ 3×), pressure (~ 2×), and mass (~ 2×). These results are consistent with self-heating dominating other power balance terms. The burn rate increases by an order of magnitude after peak compression, and the hot-spot conditions show clear evidence for burn propagation into the dense fuel surrounding the hot spot. These novel dynamics and thermodynamic properties have never been observed on prior inertial fusion experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Testing the optical components for the National Ignition Facility time-resolved soft x-ray opacity spectrometer (OpSpecTR)

Opacity measurements are being carried out at the Z-facility at Sandia National Laboratories and at the National Ignition Facility (NIF) at Lawrence Livermore National Laboratory. The current soft x-ray Opacity Spectrometer (OpSpec) used on the NIF uses two elliptically bent crystals in time-integrated mode on either an image plate or a film. Plans are under way to expand these opacity measurements into a mode of time-resolved detection, called OpSpecTR. Previously, considerations for the available hCMOS detector size and photometrics led to a crystal geometry redesign and the use of a grazing angle x-ray mirror. The mirror acts as a low-pass x-ray energy filter, reducing the contribution of higher energy x rays. The first tests of the mirror and the crystal for OpSpecTR are presented here. The size of the mirror reflection and the reflectivity is tested using a Manson x-ray source. The mirror coupled with the new elliptical crystal shape demonstrates OpSpecTR’s spectral coverage. Finally, the results from the x-ray optics performance testing are shown along with the intended design.

47 OTHER INSTRUMENTATION↗

A Functional Reference Architecture and Assessment Thereof for the National Ignition Facility Industrial Controls Systems

The Industrial Control System (ICS) at the National Ignition Facility (NIF) has an effective, well-established architecture based off a conventional cyclical software paradigm focused on maintainability and the identification of issues. This architecture exhibits scalability in ensuring expansions of the system conform to the existing architecture, modularity enough to allow relatively easy integrations of such expansions and works as a successful tool to introduce control system engineers new to the NIF ICS to the structure of the system at each layer. This architecture, like most software architectures, is object-oriented, lending itself to ease of understanding by control systems engineers and software engineers familiar with an object-oriented perspective. There are occasions, however, where engineers of other disciplines require insight into the functionality and structure of the ICS for the purposes of understanding fundamentally how their own system is or will be governed by the ICS, without the need for the details of operation of the ICS or the object-oriented view. For this reason, a functional architecture of the ICS could be a potent tool for communicating this insight. Even more powerful, a generalization of this proposed functional ICS architecture in the form of a National Ignition Facility and Photon Science (NIF & PS) Industrial Controls Reference Architecture could communicate this insight not just to systems governed by the ICS in the NIF proper, but across entirety of the NIF & PS Principal Associate Directorate (PAD), anywhere an instance of the ICS architecture is present, such as the approximately 40 “small labs” distributed across the directorate. Such a tool will provide an alternative means of understanding the implementation of these control systems, conducive to a larger variety of engineering and scientific disciplines.

42 ENGINEERING↗

View factor estimation of hot spot velocities in inertial confinement fusion implosions at the National Ignition Facility

nertial confinement fusion (ICF) experiments at the National Ignition Facility (NIF) suffer from asymmetries in thex-ray drive that degrade capsule performance compared to expectations for a symmetric one-dimensional implosion.Mode 1, or pole-to-pole, drive asymmetry can reduce confinement and implosion efficiency, driving a bulk motion ofthe hot spot that is detectable with neutron diagnostics. Understanding and removing sources of mode 1 asymmetry inICF implosions is important for improving performance, and the three-dimensional nature of the problem makes high-resolution radiation-hydrodynamic modeling extremely computationally expensive. This work describes a reducedorder view factor model that calculates the drive asymmetry induced by beam-to-beam variations in laser delivery andhohlraum diagnostic windows along the equator. Capsule response is estimated by coupling to a Green’s function thatrelates final hot spot velocity to the applied time-varying mode 1 asymmetry. The model makes several predictionsabout the impact of mode 1 drivers such as laser delivery and target misalignment, and achieves good agreementin both magnitude and vector direction for several shots in three families of high-performance platforms. However,notable discrepancies suggest other potential sources of mode 1 asymmetry not captured by the model are also at play

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Single and Double Shell Ignition Targets for the National Ignition Facility at 527 nm

Converting and using the National Ignition Facility (NIF) to deliver 527 nm light instead of its current 351 nm would allow the laser to deliver more energy and power to ignition targets. We update previous 527 nm target design work to reflect more contemporary target designs using high-density carbon capsules and low density helium gas filled Hohlraums. We extend single shell capsule designs based on current experimental results to higher energy and power and also explore double shell capsules, both driven by green light. These studies were completed using detailed pulse shapes found for targets that converged with acceptable 2D implosion symmetries and then used the Lava Lamp II code to confirm their feasibility at NIF. A 1.2× dimensional scaleup of one tuned NIF target at the limit of its current 351 nm capabilities and shot 170827 uses 3.3 MJ, at the limit of the current NIF's 527 nm capability. With the less-structured pulse of a double shell target, 3.7 MJ could be delivered by the laser. Our LPI calculations do not preclude operation at 527 nm, particularly for low fill Hohlraums, and suggest that the stimulated Raman backscatter may be no worse than the small quantities seen in 170827; stimulated forward Raman scattering may be present. If Stimulated Brillouin Scattering is too great, the much greater laser bandwidth available at 527 nm could be used to decrease backscatter. These larger targets with higher energy and power may offer a better chance of achieving ignition with only modest changes to the NIF laser.

43 PARTICLE ACCELERATORS↗

Hydroscaling indirect-drive implosions on the National Ignition Facility

A goal of the laser-based National Ignition Facility (NIF) is to increase the liberated fusion energy “yield” in inertial confinement fusion experiments well past the ignition threshold and the input laser energy. One method of increasing the yield, hydrodynamic scaling of current experiments, does not rely on improving compression or implosion velocity, but rather increases the scale of the implosion to increase hotspot areal density and confinement time. Indirect-drive (Hohlraum driven) implosions carried out at two target sizes, 12.5% apart, have validated hydroscaling expectations. Moreover, extending comparisons to the best-performing implosions at five different capsule sizes shows that their performance also agrees well with hydroscaling expectations even though not direct hydroscales of one another. In the future, by switching to a reduced loss Hohlraum geometry, simulations indicate that we can drive 20% larger-scale implosions within the current power and energy limitations on the NIF. Finally, at the demonstrated compression and velocity of these smaller-scale implosions, these 1.2× hydroscaled implosions should put us well past the ignition threshold.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

2nd and 3rd order spectral energy corrections with penumbral de-blurring methodology for opacity platform used on the National Ignition Facility

The Opacity Spectrometer (OpSpec) used in the National Ignition Facility’s opacity experiments measures x-ray spectra from 0.9 to 2.1 keV from the different experimental regions: the backlight source, emission source, and the absorption region with the transmission calculated from these regions. The OpSpec designs have gone through several iterations to help improve the signal-to-noise ratio, remove alternate crystal plane reflections, and improve spectral resolution, which helps to increase the validity of the opacity measurements. However, the source spans well outside the current working spectral range, and higher-order reflections are intrinsic to the crystal, which increases the overall signal seen in the data regions. The recorded data are the convolution of 1st order transmission, higher-order reflections, and the penumbra blurring. In conclusion, this work represents the details for deconvolving the 2nd and 3rd order spectral energy corrections with a penumbral de-blurring to correct the relative measurement of x-ray intensity of different spectral energies and further analysis of datasets relevant to the opacity experiments.

47 OTHER INSTRUMENTATION↗

Simulated impact of fill tube geometry on recent high-yield implosions at the National Ignition Facility

Inertial confinement fusion capsules fielded at the National Ignition Facility are filled with deuterium and tritium fuel by means of a fill tube. The fill tube introduces a low-density pathway into the fuel region of the capsule that allows high Z contaminant to invade the hot spot during the course of the implosion. A recent series of nominally identical high-yield implosions on the NIF has exhibited significant variability in performance. We evaluate the impact of the fill tube in these implosions computationally to determine whether variations in fill tube geometry could have contributed to this variability. The main contrast between the fill tube geometry in the six shots was the outer diameter of the capsule bore hole, a conical hole into which the fill tube is inserted. In our simulations, the geometry of the bore hole can play a significant role in the development of nonlinear flows seeded by the fill tube. Additionally, we find that the amount of space between the bore hole and the fill tube is the primary factor that determines the amount of contaminant jetted into the hot spot by the fill tube and, in turn, the level of yield reduction due to the fill tube in our simulations. As a consequence, some capsules with 5 μm fill tubes are predicted to outperform capsules with 2 μm fill tubes. We also find that micrometer-scale changes to bore hole size can impact fusion yields by up to four times near the ignition threshold. Nevertheless, simulation trends do not reproduce experimental yield trends, suggesting that the fill tube geometry was not the primary factor contributing to the observed variability in performance and that the fill tube could be masking sensitivity to other asymmetries such as other micrometer-scale capsule defects like voids that were not included in our simulations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Constraining the 3He + 3He Gamow energy probed in high energy density plasmas at the National Ignition Facility

Polar-direct-drive implosions at the National Ignition Facility generated large plasma volumes to study the 3He + 3He fusion reaction. The ion temperature, which determines the Gamow peak energy, was constrained by isolating the thermal contribution to the D3He-proton spectral width in a 3He plasma doped with deuterium. X-ray penumbral imaging was used to measure electron temperature, density, and hotspot volume, which was subsequently used to model the spectral broadening from plasma stopping power. Results showed 30% of the D3He-proton spectral width was due to stopping power, with residual flows contributing ≈10%. The 3He temperature was determined as T3He = 12.4 ± 3.2 keV, corresponding to a Gamow energy of 95 ± 14 keV. These experiments achieved the lowest Gamow energy to date for studying 3He + 3He fusion in high energy density plasma, approaching conditions in the Sun.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A dual high-energy radiography platform with 15 μ m resolution at the National Ignition Facility

To study matter at extreme densities and pressures, we need mega laser facilities such as the National Ignition Facility as well as creative methods to make observations during timescales of a billionth of a second. To facilitate this, we developed a platform and diagnostic to characterize a new point-projection radiography configuration using two micro-wires irradiated by a short pulse laser system that provides a large field of view with up to 3.6 ns separation between images. In this work, we used tungsten-carbide solid spheres as reference objects and inferred characteristics of the back-lighter source using a forward-fitting algorithm. The resolution of the system is inferred to be 15 μm (using 12.5 μm diameter wires). The bremsstrahlung temperature of the source is 70–300 keV, depending on laser energy and coupling efficiency. By adding the images recorded on multiple stacked image plates, the signal-to-noise of the system is nearly doubled. The imaging characterization technique described here can be adapted to most point-projection platforms where the resolution, spectral contrast, and signal-to-noise are important.

47 OTHER INSTRUMENTATION↗

Crystal response measurement of the x-ray transmission crystals used by the Imaging Spectroscopy Snout at the National Ignition Facility

The Imaging Spectroscopy Snout (ISS) used at the National Ignition Facility is able to simultaneously collect neutron pinhole images, 1D spatially resolved x-ray spectra, and time resolved x-ray pinhole images. To measure the x-ray spectra, the ISS can be equipped with up to four different transmission crystals, each offering different energy ranges from ∼7.5 to ∼12 keV and different resolutions. Characterizing and calibrating such instruments is of paramount importance in order to extract meaningful results from experiments. More specifically, we characterized different ISS transmission-type alpha-Quartz crystals by measuring their responses as a function of photon energy, from which we inferred the angle-integrated reflectivity for each crystal’s working reflections. These measurements were made at the Lawrence Livermore National Laboratory calibration station dedicated to the characterization of x-ray spectrometers. The sources used covered a wide x-ray range—from a few to 30 keV; the source diameter was ∼0.6 mm. The experimental results are discussed alongside theoretical calculations using the pyTTE model.

Dozieres, M. (ORCID:0000000286401459)↗

Density measurements for the National Ignition Facility (NIF) opacity platform

The Opacity Platform on the National Ignition Facility (NIF) has been developed to measure opacities at varying densities and temperatures relevant to the solar interior and thermal cooling rates in white dwarf stars. The typical temperatures reached at NIF range between 150 and 210 eV, which allow these measurements to be performed experimentally. The captured opacities are crucial to validating radiation-hydrodynamic models that are used in astrophysics. The NIF opacity platform has a unique new capability that allows in situ measurement of the sample expansion. The sample expansion data are used to better understand the plasma conditions in our experiments by inferring the sample density throughout the duration of the laser drive. Here, we present the details of the density measurement technique, data analysis, and recent results for Fe and MgO.

47 OTHER INSTRUMENTATION↗

The colliding planar shocks platform to study warm dense matter at the National Ignition Facility

We have developed an experimental platform at the National Ignition Facility that employs colliding planar shocks to produce warm dense matter with uniform conditions and enable high-precision equation of state measurements. The platform uses simultaneous x-ray Thomson scattering and x-ray radiography to measure the density, electron temperature, and ionization state in warm dense matter. The experimental platform is designed to create a large volume of uniform plasma (approximately 700×700×150μm 3 ) at pressures approaching 100 Mbar and minimize the distribution of plasma conditions in the x-ray scattering volume, significantly improving the precision of the measurements. Here, in this study, we present the experimental design of the platform and compare hydrodynamic simulations to x-ray radiography data from initial experiments studying hydrocarbons, producing uniform densities within ±25% of the average probed condition. We show that the platform creates a homogeneous plasma that can be characterized using x-ray Thomson scattering. Thus, the new platform enables accurate measurements of plasma conditions necessary to test models for the equation of state and ionization potential depression in the warm dense matter regime.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

National Ignition Facility Opacity Time Resolved Spectrometer Systems Engineering Final Project

The National Ignition Facility (NIF) is the world’s largest and most energetic laser facility. The NIF system is designed to produce high energy density (temperature and pressure) conditions through the application of its 192 laser beams. One of the users of NIF is the opacity platform developed to study the opacities at temperatures and densities relevant to the solar interior and stellar evolution. The platform was developed to study iron (Fe) opacity at temperatures relevant to the solar interior. The opacity campaign uses spectrometers to gather data. Spectrometers utilize crystals to produce x-ray spectra that are recorded on time-integrated and time-resolved detectors. The opacity spectrometer (OpSpec) currently fielded and in use at NIF uses a time integrated film channel to collect data. The opacity spectrometer time resolved (OpSpecTR) will utilize novel hCMOS detectors to capture time resolved images of spectra of interest. The key stakeholders identified for OpSpecTR included the physicists responsible for OpSpec and OpSpecTR, the Target Area Science and Engineering (TASE) department at NIF, the NIF and Photon Science (NIF & PS) Opacity program, the Nevada National Security Site (NNSS) Physics and Engineering program, the Sandia hCMOS manufacturing and testing program, and the Los Alamos National Laboratory (LANL) program sponsor. The Target and Experimental Operations (TEXOPS) was identified as a key stakeholder because the group includes the individuals that will physically interact with the OpSpecTR system as it participates in NIF experiments. The opacity platform collects data in a unique orientation relative to the existing diagnostics fielded at NIF. The existing infrastructure at NIF uses a diagnostic manipulator (DIM) to insert the diagnostic near the target chamber center to collect data during a NIF shot. Existing diagnostics collect data through the center line of the DIM axis and collect relevant data perpendicular to this axis. The opacity platform requires crystals mounted in a specific orientation which requires data collection parallel to the DIM axis. This deviation from standard NIF practices was a key factor in developing requirements.

42 ENGINEERING↗

Top-level physics requirements and simulated performance of the MRSt on the National Ignition Facility

The time-resolving Magnetic Recoil Spectrometer (MRSt) for the National Ignition Facility (NIF) has been identified by the US National Diagnostic Working Group as one of the transformational diagnostics that will reshape the way inertial confinement fusion (ICF) implosions are diagnosed. The MRSt will measure the time-resolved neutron spectrum of an implosion, from which the time-resolved ion temperature, areal density, and yield will be inferred. Top-level physics requirements for the MRSt were determined based on simulations of numerous ICF implosions with varying degrees of alpha heating, P2 asymmetry, and mix. Synthetic MRSt data were subsequently generated for different configurations using Monte–Carlo methods to determine its performance in relation to the requirements. The system was found to meet most requirements at current neutron yields at the NIF. This work was supported by the DOE and LLNL.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Top-level physics requirements and simulated performance of the MRSt on the National Ignition Facility

The time-resolving Magnetic Recoil Spectrometer (MRSt) for the National Ignition Facility (NIF) has been identified by the US National Diagnostic Working Group as one of the transformational diagnostics that will reshape the way inertial confinement fusion (ICF) implosions are diagnosed. The MRSt will measure the time-resolved neutron spectrum of an implosion, from which the time-resolved ion temperature, areal density, and yield will be inferred. Top-level physics requirements for the MRSt were determined based on simulations of numerous ICF implosions with varying degrees of alpha heating, P2 asymmetry, and mix. Synthetic MRSt data were subsequently generated for different configurations using Monte–Carlo methods to determine its performance in relation to the requirements. The system was found to meet most requirements at current neutron yields at the NIF. This work was supported by the DOE and LLNL.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modeling ablator defects as a source of mix in high-performance implosions at the National Ignition Facility

Recent indirect drive inertial confinement fusion implosions on the National Ignition Facility (NIF) [Spaeth et al., Fusion Sci. Technol. 69, 25 (2016)] have crossed the threshold of ignition. However, performance has been variable due to several factors. One of the leading sources of variability is the quality of the high-density carbon (HDC) shells used as ablators in these experiments. In particular, these shells can have a number of defects that have been found to correlate with the appearance of ablator mix into the hot spot and a degradation in nuclear yield. These defects include pits on the ablator surface, voids in the ablator bulk, high-Z debris from the Hohlraum wall that adheres to the capsule surface, and finally the inherent granular micro-structure of the crystalline HDC itself. This paper summarizes high-resolution modeling of each of these mix sources in two recent high-performance NIF implosion experiments. The simulated impact from a range of individual capsule defects is found to be broadly consistent with the trends seen in experiment, lending credence to the modeling results and the details of the mixing process that they reveal. Interestingly, modeling of the micro-structure inherent to HDC shows that this perturbation source results in considerable mixing of the deuterium–tritium fuel with ablator material during the implosion. The reduction in fuel compression from this mix results in an approximately factor of two reduction in neutron yield in current implosions and emphasizes the importance of mitigating this significant performance degradation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗