Search NASA⌕ Search

SEARCH · Search NASA

Results for “net present value”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

DC-Connected Solar Plus Storage Modeling and Analysis for Behind-the-Meter Systems in the System Advisor Model

A detailed model for PV plus DC-connected batteries was developed. This model was compared to an existing ACconnected battery model in the System Advisor Model (SAM) tool using a hypothetical Honolulu residence with a PV plus storage system. The stand-alone PV system was shown to provide the most value; however due to the increased difficulty of PV systems being approved for grid interconnection in Hawaii, it is valuable to install an AC or DC connected battery to enable full PV self-consumption under a less restrictive interconnection option. In that case both battery systems enabled full PV selfconsumption at the residence, requiring no power to be exported to the grid. The DC-connected battery system captured energy from the PV array which would have also been clipped due to inverter limitations. For a PV system with DC/AC ratio of 1.23, the battery configurations produced net-present values within 1% of each other, but when the DC/AC ratio increased to 1.85, the DC-connected system increased the net-present value by 13%.

14 SOLAR ENERGY↗

DC-connected Solar Plus Storage Modeling and Analysis for Behind-The-Meter Systems in the System Advisor Model: Preprint

A detailed model for PV plus DC-connected batteries was developed. This model was compared to an existing AC connected battery model in the System Advisor Model (SAM) tool using a hypothetical Honolulu residence with a PV plus storage system. The stand-alone PV system was shown to provide the most value; however due to the increased difficulty of PV systems being approved for grid interconnection in Hawaii, it is valuable to install an AC or DC connected battery to enable full PV self-consumption under a less restrictive interconnection option. In that case both battery systems enabled full PV self consumption at the residence, requiring no power to be exported to the grid. The DC-connected battery system captured energy from the PV array which would have also been clipped due to inverter limitations. For a PV system with DC/AC ratio of 1.23, the battery configurations produced net-present values within 1% of each other, but when the DC/AC ratio increased to 1.85, the DC-connected system increased the net-present value by 13%.

14 SOLAR ENERGY↗

DC-Connected Solar Plus Storage Modeling for Behind-the-Meter Systems in SAM

A detailed model for PV plus DC-connected batteries was developed. This model was compared to an existing AC connected battery model in the System Advisor Model (SAM) tool using a hypothetical Honolulu residence with a PV plus storage system. The stand-alone PV system was shown to provide the most value; however due to the increased difficulty of PV systems being approved for grid interconnection in Hawaii, it is valuable to install an AC or DC connected battery to enable full PV self-consumption under a less restrictive interconnection option. In that case both battery systems enabled full PV self consumption at the residence, requiring no power to be exported to the grid. The DC-connected battery system captured energy from the PV array which would have also been clipped due to inverter limitations. For a PV system with DC/AC ratio of 1.23, the battery configurations produced net-present values within 1% of each other, but when the DC/AC ratio increased to 1.85, the DC-connected system increased the net-present value by 13%.

14 SOLAR ENERGY↗

Quantifying Occupant Health and Productivity for Deep Retrofits: Beyond Traditional IEQ Studies

As energy-efficiency standards for both new construction and existing building renovations become more stringent, further reductions become less tractable and more expensive. With increasing interest and rising investment in healthy built environments, integrating energy efficiency with improved occupant experience (i.e., health, comfort, and work performance) offers a new path to drive deep energy retrofits. However, the difficulty in quantifying and verifying health and productivity gains from building upgrades leads to lower valuation of human benefits in practice. Building codes and standards have progressive energy targets but often give minimum requirements to occupant health for factors such as ventilation and thermal comfort. State and federal laws in the United States that govern the energy service performance contract (ESPC) have no clear and consistent guidance on quantifying non-energy benefits and incorporating them into a formal cost-effectiveness analysis. This paper presents a methodology to measure a building’s potential performance improvement regarding occupant health based on existing evidence correlating IEQ to occupant outcomes. Health improvement measures are integrated with a building energy model to identify and measure the impact of holistic improvement strategies. The net present value of these measures is determined based on the investment costs required to attain those improvements, energy savings, and personnel gains. We will discuss results from one pilot building, which showed nearly $50 per square foot 20-year net present value using the integrated approach.

Keene, Kevin M.↗

Hydro-frac monitoring using ground time-domain electromagnetics: Hydro-frac monitoring using ground time-domain EM

& Engineers. As motivation for considering new electromagnetic techniques for hydraulic fracture monitoring, we develop a simple financial model for the net present value offered by geophysical characterization to reduce the error in stimulated reservoir volume calculations. Additionally, this model shows that even a 5% improvement in stimulated reservoir volume for a 1 billion barrel (bbl) field results in over 1 billion U.S. dollars (US$) in net present value over 24 years for US$100/bbl. oil and US$0.5 billion for US$50/bbl. oil. The application of conductivity upscaling, often used in electromagnetic modeling to reduce mesh size and thus simulation runtimes, is shown to be inaccurate for the high electrical contrasts needed to represent steel-cased wells in the earth. Fine-scale finite-difference modeling with 12.22-mm cells to capture the steel casing and fractures shows that the steel casing provides a direct current pathway to a created fracture that significantly enhances the response compared with neglecting the steel casing. We consider conductively enhanced proppant, such as coke-breeze-coated sand, and a highly saline brine solution to produce electrically conductive fractures. For a relatively small frac job at a depth of 3 km, involving 5,000 bbl. of slurry and a source midpoint to receiver separation of 50 m, the models show that the conductively enhanced proppant produces a 15% increase in the electric field strength (in-line with the transmitter) in a 10-Ωm background. In a 100-Ωm background, the response due to the proppant increases to 213%. Replacing the conductive proppant by brine with a concentration of 100,000-ppm NaCl, the field strength is increased by 23% in the 100-Ωm background and by 2.3% in the 10-Ωm background. Finally, all but the 100,000-ppm NaCl brine in a 10-Ωm background produce calculated fracture-induced electric field increases that are significantly above 2%, a value that has been demonstrated to be observable in field measurements. © 2015 European Association of Geoscientists

58 GEOSCIENCES↗

Economic Analysis Case Studies of Battery Energy Storage with SAM

Interest in energy storage has continued to increase as states like California have introduced mandates and subsidies to spur adoption. This energy storage includes customer sited behind-the-meter storage coupled with photovoltaics (PV). This paper presents case study results from California and Tennessee, which were performed to assess the economic benefit of customer-installed systems. Different dispatch strategies, including manual scheduling and automated peak-shaving were explored to determine ideal ways to use the storage system to increase the system value and mitigate demand charges. Incentives, complex electric tariffs, and site specific load and PV data were used to perform detailed analysis. The analysis was performed using the free, publically available System Advisor Model (SAM) tool. We find that installation of photovoltaics with a lithium-ion battery system priced at $300/kWh in Los Angeles under a high demand charge utility rate structure and dispatched using perfect day-ahead forecasting yields a positive net-present value, while all other scenarios cost the customer more than the savings accrued. Different dispatch strategies, including manual scheduling and automated peak-shaving were explored to determine ideal ways to use the storage system to increase the system value and mitigate demand charges. Incentives, complex electric tariffs, and site specific load and PV data were used to perform detailed analysis. The analysis was performed using the free, publically available System Advisor Model (SAM) tool. We find that installation of photovoltaics with a lithium-ion battery system priced at $300/kWh in Los Angeles under a high demand charge utility rate structure and dispatched using perfect day-ahead forecasting yields a positive net-present value, while all other scenarios cost the customer more than the savings accrued.

14 SOLAR ENERGY↗

Methodology for Outdoor Water Savings Model and Spreadsheet Tool for U.S. and Selected States

Green lawns and landscaping are archetypical of the populated American landscape, and typically require irrigation, which corresponds to a significant fraction of residential, commercial, and institutional water use. In North American cities, the estimated portion of residential water used for outdoor purposes ranges from 22-38% in cooler climates up to 59-67% in dry and hot environments, while turfgrass coverage within the United States spans 11.1-20.2 million hectares (Milesi et al. 2009). One national estimate uses satellite and aerial photography data to develop a relationship between impervious surface and lawn surface area, yielding a conservative estimate of 16.4 (± 3.6) million hectares of lawn surface area in the United States—an area three times larger than that devoted to any irrigated crop (Milesi et al. 2005). One approach that holds promise for cutting unnecessary outdoor water use is the increased deployment of “smart” irrigation controllers to increase the water efficiency of irrigation systems. This report describes the methodology and inputs employed in a mathematical model that quantifies the effects of the U.S. Environmental Protection Agency’s WaterSense labeling program for one such type of controller, weather-based irrigation controllers (WBIC). This model builds off that described in “Methodology for National Water Savings Model and Spreadsheet Tool–Outdoor Water Use” and uses a two-tiered approach to quantify outdoor water savings attributable to the WaterSense program for WBIC, as well as net present value (NPV) of that savings. While the first iteration of the model assessed national impacts using averaged national values, this version begins by evaluating impacts in three key large states that make up a sizable portion of the irrigation market: California, Florida, and Texas. These states are considered to be the principal market of “smart” irrigation controllers that may result in the bulk of national savings. Modeled water savings and net present value for these three states should be more accurate and representative than the averaged national values given state-specific inputs such as lot size, water price, and housing stock. To complete the picture of national impacts, the remaining WBIC shipments not assigned to these three states are assessed using the original methodology based on the averaged national values.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Screening Tool for Equitable Adoption and Deployment of Solar (STEADy Solar)

The Screening Tool for Equitable Adoption and DeploYment of Solar (STEADy Solar) is a database and mapping tool designed to promoting clean energy investments for low-income communities across the United States. The tool indicates locations that may be eligible for the Investment Tax Credit bonus adders defined in the 2022 Inflation Reduction Act (IRA) and combines this information with demographics, social vulnerability, solar technical potential, solar economics (modeled net present value), and building counts by use-type. It can be used by states, municipalities, community-based organizations, developers, and researchers to identify sites where solar projects may be economical and where federal incentives may be available to support equitable adoption of solar. Specific values include: Areas eligible for the Energy Communities Tax Credit Bonus Program (including brownfield site counts) Areas eligible for the Low Income Communities Bonus Credit Program (including Tribal Lands, and covered affordable housing project counts) Areas categorized as disadvantaged by Justice40 Commercial and Residential Solar economics characterized by the Net Present Value and Simple Payback Period Total Population, Race, and Ethnicity Median Household Income, Poverty rate, Household Tenure Social Vulnerability Count of buildings, developable rooftop solar capacity (in kWdc) and estimated annual generation potential (in kWh) on four building types: Government General Services, Government Emergency Response, Grade Schools, and Colleges/Universities. The linked report describes the STEADy dataset metadata and presents high level insights from the data. The downloadable and formatted excel dataset makes it easy for users to gain insights for their locations. Supporting .csv and shapefiles provide users with the full data to run their own analyses on equitable solar siting.

14 SOLAR ENERGY↗

A cost-benefit analysis of landfill mining and material recycling in China

Highlights: • Assessing the economic feasibility of landfill mining. • We applied a cost-benefit analysis model for landfill mining. • Four material cycling and energy recovery scenarios were designed. • We used net present value to evaluate the cost-benefit efficiency. - Abstract: Landfill mining is an environmentally-friendly technology that combines the concepts of material recycling and sustainable waste management, and it has received a great deal of worldwide attention because of its significant environmental and economic potential in material recycling, energy recovery, land reclamation and pollution prevention. This work applied a cost-benefit analysis model for assessing the economic feasibility, which is important for promoting landfill mining. The model includes eight indicators of costs and nine indicators of benefits. Four landfill mining scenarios were designed and analyzed based on field data. The economic feasibility of landfill mining was then evaluated by the indicator of net present value (NPV). According to our case study of a typical old landfill mining project in China (Yingchun landfill), rental of excavation and hauling equipment, waste processing and material transportation were the top three costs of landfill mining, accounting for 88.2% of the total cost, and the average cost per unit of stored waste was 12.7 USD ton{sup −1}. The top three benefits of landfill mining were electricity generation by incineration, land reclamation and recycling soil-like materials. The NPV analysis of the four different scenarios indicated that the Yingchun landfill mining project could obtain a net positive benefit varying from 1.92 million USD to 16.63 million USD. However, the NPV was sensitive to the mode of land reuse, the availability of energy recovery facilities and the possibility of obtaining financial support by avoiding post-closure care.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Stochastic Simplex Approximate Gradient for Robust Life-cycle Production Optimization: Applied to Brugge Field

In oil and gas production industry, production optimization is a viable technique to maximize the oil/gas production or net present value (NPV). Robust optimization is one type of production optimization techniques where the geological uncertainty of reservoir is considered. When well operating conditions, e.g., well flow rates and bottom-hole pressures, are the optimization variables, ensemble-based optimization (EnOpt) is the most popular ensemble-based algorithm for robust life-cycle production optimization. Recently, however, a superior algorithm, stochastic simplex approximate gradient (StoSAG), was proposed. Finally, the purpose of this study is to provide a theoretical discussion on why StoSAG is generally superior to EnOpt and provide reasonable example (Brugge field) where StoSAG generates estimates of optimal well controls that give a life-cycle net present value (NPV) significantly higher than the NPV obtained from EnOpt.

02 PETROLEUM↗

A Method for the Selection of Exploration Areas for Unconformity Uranium Deposits

The method we propose employs two analyses: (1) exploration simulation and risk valuation and (2) portfolio optimization. The first analysis, implemented by the investment worth system (IWS), uses Monte Carlo simulation to integrate a wide spectrum of uncertain and varied components to a relative frequency histogram for net present value of the exploration investment, which is converted to a risk-adjusted value (RAV). Iterative rerunning of the IWS enables the mapping of the relationship of RAV to magnitude of exploration expenditure, X. The second major analysis uses RAV vs. X maps to identify that subset (portfolio) of areas that maximizes the RAV of the firm's multiyear exploration budget. The IWS, which is demonstrated numerically, consists of six components based on the geologic description of a hypothetical basin and project area (PA) and a mix of hypothetical and actual conditions of an unidentified area. The geology is quantified and processed by Bayesian belief networks to produce the geology-based inputs required by the IWS. An exploration investment of $60 M produced a highly skewed distribution of net present value (NPV), having mean and median values of $4,160 M and $139 M, respectively. For hypothetical mining firm Minex, the RAV of the exploration investment of $60 M is only $110.7 M. An RAV that is less than 3% of mean NPV reflects the aversion by Minex to risk as well as the magnitude of risk implicit to the highly skewed NPV distribution and the probability of 0.45 for capital loss. Potential benefits of initiating exploration of a portfolio of areas, as contrasted with one area, include increased marginal productivity of exploration as well as reduced probability for nondiscovery. For an exogenously determined multiyear exploration budget, a conceptual framework for portfolio optimization is developed based on marginal RAV exploration products for candidate PAs. PORTFOLIO, a software developed to implement optimization, allocates exploration to PAs so that the RAV of the exploration budget is maximized. Moreover, PORTFOLIO provides a means to examine the impact of magnitude of budget on the composition of the exploration portfolio and the optimum allocation of exploration to PAs that comprise the portfolio. Using fictitious data for five PAs, a numerical demonstration is provided of the use of PORTFOLIO to identify those PAs that comprise the optimum exploration portfolio and to optimally allocate the multiyear budget across portfolio PAs.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Economic Evaluation of a Coupled Nuclear Power Plant and Hydrogen Production Facility: A Case Study

This study optimized the design sizes and operation of a power-to-hydrogen-to-power integrated energy system to allow a baseload power plant to operate flexibly in the energy market. In collaboration with a utility industry partner, the system, consisting of an electrolyzer, compressors, storage tank, and fuel cell, was optimized under conditions specific to the proposed project at the site of a nuclear power plant. The Design Integration and Synthesis Platform to Advance Tightly Coupled Hybrid Energy Systems (DISPATCHES) maximized net present value by optimizing sizing of components and dispatch decisions. Revenues included sale of electricity, capacity payments typical of the New York Independent System Operator, and the section 45V hydrogen production tax credit of the Inflation Reduction Act of 2022 (the tax credit was assumed to be available to legacy plants in the absence of clear guidance at present). Under default assumptions which excluded many capital expenditures, the base case optimized solution had a net present value of $\$$1.4 million over a 30 year lifetime, with a 0.365 MW fuel cell operating nearly continuously and 85% of revenues supplied by the hydrogen production tax credit (which was counted as a revenue regardless of profit, thus assuming credit monetization or offset of taxes within the larger firm was possible in all years). Beyond the base case, a sensitivity study elucidated drivers of the economics as capacity payment rate and hydrogen production tax credit rate vary. Additional sensitivity studies also extended results to variation of other, previously fixed parameters, including the fuel cell capital cost, and to imposition of further constraints. Optimization was also repeated for the default assumptions but recognizing tax credits upon use of hydrogen rather than upon its production, producing no change in the optimal solution. Most notably, capacity payments above $\$$15/kW-month drove optimal fuel cells multiple times larger than those with the default estimated capacity payment of $\$$2.5/kW-month (approaching 11 vs. 0.365 MW), and these larger fuel cells operated rarely (capacity factors of ~0.03). Furthermore, when the hydrogen production tax credit was provided for only 10 years, under the specific assumptions of this study (e.g., neither site preparation costs nor electrolyzer capital cost counted), the optimal solution avoided economic loss by ceasing system operation after the 10th year. Viewed broadly, this study demonstrated the capabilities of DISPATCHES, which can be user-adapted to serve other industrial case studies.

08 HYDROGEN↗

Analysis of Minimum Efficiency Performance Standards for Residential General Service Lighting in Chile

Minimum Efficiency Performance Standards (MEPS) have been chosen as part of Chile's national energy efficiency action plan. As a first MEPS, the Ministry of Energy has decided to focus on a regulation for lighting that would ban the sale of inefficient bulbs, effectively phasing out the use of incandescent lamps. Following major economies such as the US (EISA, 2007) , the EU (Ecodesign, 2009) and Australia (AS/NZS, 2008) who planned a phase out based on minimum efficacy requirements, the Ministry of Energy has undertaken the impact analysis of a MEPS on the residential lighting sector. Fundacion Chile (FC) and Lawrence Berkeley National Laboratory (LBNL) collaborated with the Ministry of Energy and the National Energy Efficiency Program (Programa Pais de Eficiencia Energetica, or PPEE) in order to produce a techno-economic analysis of this future policy measure. LBNL has developed for CLASP (CLASP, 2007) a spreadsheet tool called the Policy Analysis Modeling System (PAMS) that allows for evaluation of costs and benefits at the consumer level but also a wide range of impacts at the national level, such as energy savings, net present value of savings, greenhouse gas (CO2) emission reductions and avoided capacity generation due to a specific policy. Because historically Chile has followed European schemes in energy efficiency programs (test procedures, labelling program definitions), we take the Ecodesign commission regulation No 244/2009 as a starting point when defining our phase out program, which means a tiered phase out based on minimum efficacy per lumen category. The following data were collected in order to perform the techno-economic analysis: (1) Retail prices, efficiency and wattage category in the current market, (2) Usage data (hours of lamp use per day), and (3) Stock data, penetration of efficient lamps in the market. Using these data, PAMS calculates the costs and benefits of efficiency standards from two distinct but related perspectives: (1) The Life-Cycle Cost (LCC) calculation examines costs and benefits from the perspective of the individual household; and (2) The National Perspective projects the total national costs and benefits including both financial benefits, and energy savings and environmental benefits. The national perspective calculations are called the National Energy Savings (NES) and the Net Present Value (NPV) calculations. PAMS also calculate total emission mitigation and avoided generation capacity. This paper describes the data and methodology used in PAMS and presents the results of the proposed phase out of incandescent bulbs in Chile.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Economic assessment of a multistage surface-heated vacuum membrane distillation process for the treatment of hypersaline produced water

Here, the treatment and disposal of hypersaline produced water remains a challenge, particularly for oil and gas producers in the Permian basin where production wells generate significant amounts of wastewater, and the traditional method of injecting wastewater into disposal wells is coming under increasing scrutiny. Here we investigate the viability of using solar energy to power a multi-stage, surface heated, vacuum membrane distillation (SHVMD) with energy recovery to treat hypersaline produced wastewater from Midland, Texas. Membrane distillation is a process that can desalinate waters with high total dissolved solids concentration, and when incorporated into a system with surface heating and energy recovery can achieve high water recovery rates. Model results show that a 6-stage SHVMD system with a 54.4 % water recovery rate and a gained output ratio (GOR) of 3.28 has the potential to be economically viable when used to treat hypersaline produced water in the Permian basin. Assuming energy costs of $\$0.03$/kWh thermal and $\$0.12$kWh electric , we estimate a project net present value (NPV) of $\$225,525$ and an internal rate of return (IRR) of 13.5 % when an air cooled condensor is used to cool the distillate and a NPV of $\$570,791$ and IRR of 24.52 % when a liquid coooling source is available.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Cost-Benefit Analysis For Indonesia Building Sector: Whole-Building Cooling Solutions

The Net Zero World (NZW) Initiative Collaborative Work Program with the Government of Indonesia (GoI) includes technical assistance and investment mobilization facilitation to accelerate deployment of energy efficiency technologies and solutions for the building sector. A February 2023 U.S.–Indonesia Joint Workshop on Decarbonizing the Building Sector yielded a NZW Indonesia Building Decarbonization Working Group (NZW IBDWG) with four sub-working groups (SWG): SWG-A National Center, SWG-B Capacity Building, SWG-C Investment and Financing, and SWG-D Pilot Projects. Technical analysis of whole-building cooling solutions for tropical climates of Indonesia was conducted by SWG-A to quantify energy savings, carbon dioxide reductions, and comfort improvements offered by 12 passive or low-energy cooling strategies: ceiling fans with and without thermostat setbacks; cool roofs; cool walls; exterior awnings; exterior shades; interior shades; insulated roofs; insulated walls; low-e windows; solar window films; and natural ventilation. Leveraging the results from SWG-A, cost-benefit analysis (CBA) was conducted by SWG-C to assess the consumer and national costs and impacts associated with these 12 cooling solutions. The evaluation involved estimating life-cycle costs (LCC), payback period (PBP), net present values (NPV), annual electricity burden change for low-income households, and reduced national annual power-sector generation demand by 2030, 2040, 2050, and 2060. This evaluation can help guide Indonesia’s Just Energy Transition Partnership (JETP) investments in policies and programs to advance research, development, deployment, and commercial adoption (RDDCA) of efficient residential building sector cooling technologies and solutions in Indonesia. Four key energy conservation measures (ECM) have been identified to reduce air-conditioning (AC) energy demand in single-family housing in Indonesia: ceiling fan with temperature setback (to 28.1 °Celcius from 25 °C); insulated walls; insulated roof; and cool roof. This study found that low-income households with AC installations in Indonesia currently face a high energy cost burden of approximately 10%. However, by implementing a ceiling fan with temperature setback, this burden could decrease to 2.5% today and further reduce to 1.3% by the year 2060. The PBP for a ceiling fan with temperature setback is one year, indicating one of the lowest LCC and best NPV. In the planned upcoming phase of CBA, a series of building cooling improvement scenarios can be further defined, incorporating more than one ECM in combination with socio-economic factors evaluated in the initial CBA phase. Additionally, the analysis of ECM effects in multifamily housing can be expanded. This broader national analysis aims to encompass a holistic and comprehensive system-level perspective, including factors such as avoided power sector infrastructure investments, domestic job creation, domestic manufacturing job creation, and gross domestic product (GDP) growth.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Solid-State Transformer and Hybrid Transformer With Integrated Energy Storage in Active Distribution Grids: Technical and Economic Comparison, Dispatch, and Control

Solid-state transformer (SST) and hybrid transformer (HT) are promising alternatives to the line-frequency transformer (LFT) in smart grids. The SST features medium-frequency isolation, full controllability for voltage regulation, reactive power compensation, and the capability of battery energy storage system (BESS) integration with multiport configuration. The HT has a partially-rated converter for fractional controllability and can integrate a small BESS. Fast grid-edge voltage fluctuations from increased solar photovoltaic (PV) and electric vehicle (EV) penetration are difficult to manage for mechanical load tap changers. Hence, along with the trend towards more BESS in the grid, the controllability and the storage integration capability of the SST and HT are of strong interest. However, a review of literature shows existing SST and HT research is mostly at converter level, while system-level assessments are scarce. Assessing technical and economic impacts is critical to understanding the benefits and role of the SST and HT to guide future research, which is presented for the first time in this article. Experimental results from medium-voltage (MV) SST and MV HT prototypes are shown to confirm equipment-level feasibility, where the voltage controllability waveforms of a MV HT prototype are reported for the first time. Comparative simulations are performed on a modified IEEE 34-bus system. Here, a grid-model-less decentralized grid-edge voltage control method and a day-ahead BESS dispatch method are proposed for the SST and HT. The simulations show that the SST and HT with integrated storage can host more PV, achieve peak shaving, mitigate voltage fluctuation and reverse power flow, and support energy arbitrage for operational cost reduction, as compared to the LFT. Moreover, comprehensive analyses of net present value (NPV) and internal rate of return (IRR) are performed under different installed PV capacities, HT’s partial converter ratings, and BESS capacities. Sensitivities to future cost reductions of the PV and BESS are studied. Although the NPV and IRR are currently negative, 60% capital cost reduction or 150% revenue increase will make the SST and HT economically viable in the use case studied.

14 SOLAR ENERGY↗

Future impacts of ozone driven damages on agricultural systems

Current ozone (O 3 ) concentration levels entail significant damages in crop yields around the world. The reaction of the emitted precursors (mostly methane and nitrogen oxides) with solar radiation contribute to O 3 levels that exceed established thresholds for crop damage. This paper shows current and projected (up to 2080) relative yield losses (RYLs) driven by O 3 exposure for different crops and the associated economic damages applying dynamic crop production and prices that are calculated per region and period. We adjust future crop yields in the Global Change Assessment Model (GCAM) to reflect the RYLs and analyze the effects on agricultural markets. We find that the changes (generally reductions) in O 3 precursor emissions in a reference scenario would reduce the agricultural damages, compared to present, for most of the regions, with a few exceptions including India, where higher future O3 concentrations have large negative impacts on crop yields. The annual economic impact of O3 driven losses from 2010-2080 are, in billion US dollars at 2015 prices ($B), 5.0-6.0, 9.8-18.8, 6.7-10.6 and 10.4-12.5 for corn, soybeans, rice and wheat, respectively, with the large losses for wheat and soybeans driven by their comparatively high responses to O 3 . When O 3 effects are explicitly modelled as exogenous yield shocks in future periods, there is a direct impact in future agricultural markets. Therefore, the aggregated net present value (NPV) of crop production would be reduced around by $90.8B at a global level. However, these changes are not distributed evenly across regions, and the net present market value of the crops would increase by up to $118.2B (India) or decrease by up to $59.2B (China).

54 ENVIRONMENTAL SCIENCES↗

PV O&M Cost Model and Cost Reduction

This is a presentation on PV O&M cost model and cost reduction for the annual Photovoltaic Reliability Workshop (2017), covering estimating PV O&M costs, polynomial expansion, and implementation of Net Present Value (NPV) and reserve account in cost models.

14 SOLAR ENERGY↗