Search NASA⌕ Search

SEARCH · Search NASA

Results for “net zero codes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

High Performance Walls in Hot-Dry Climates

High performance walls represent a high priority measure for moving the next generation of new homes to the Zero Net Energy performance level. The primary goal in improving wall thermal performance revolves around increasing the wall framing from 2x4 to 2x6, adding more cavity and exterior rigid insulation, achieving insulation installation criteria meeting ENERGY STAR's thermal bypass checklist, and reducing the amount of wood penetrating the wall cavity.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Scalable Method for Decarbonizing Modular Building Solutions: Preprint

The decarbonization movement emphasizes the shift in focus from energy efficiency to directly reducing global-warming impact. Blokable, LLC, a vertically integrated modular builder with an all-electric portfolio, worked with NREL on a roadmap to decarbonize its high-performance building product at a relative cost advantage by utilizing the learning curves of mass production. Previous decarbonization literature focused on either i) lifecycle assessments, or ii) efficiency measures. These decarbonization exercises were bespoke to individual building projects and did not consider positive feedback loops of builder experience or process repetition. Vertically integrated, prefab builders possess the unique ability to leverage learning and repetition to decarbonize their design-build-operate process. This collaboration between Blokable and NREL resulted in a decarbonization strategy utilizing the company's scaling and production efficiencies, on-site renewable energy and storage, and the projected evolution of building components over time based on trends and emerging legislation. The method developed here encompasses a growing business model, lifecycle carbon assessment, and projected changes in product and grid emissions over time due to existing trends and emerging legislation. This methodology incorporates learning-curve efficiencies gleaned from scaled manufacturing, as well as open-source tools integration for energy and carbon accounting. The output projects and compares cost and carbon savings per modular unit as production increases to 10,000 dwelling units annually over 15 years. The resulting roadmap illustrates a path to roughly 60% carbon savings and beyond-net-zero-energy performance at no incremental cost by 2030. The methodology can be mapped to other integrated or productized builders for methodical decarbonization.

affordable housing↗

A Scalable Method for Decarbonizing Modular Building Solutions

The decarbonization movement emphasizes the shift in focus from energy efficiency to directly reducing global-warming impact. Blokable, LLC, a vertically integrated modular builder with an all-electric portfolio, worked with NREL on a roadmap to decarbonize its high-performance building product at a relative cost advantage by utilizing the learning curves of mass production. Previous decarbonization literature focused on either i) lifecycle assessments, or ii) efficiency measures. These decarbonization exercises were bespoke to individual building projects and did not consider positive feedback loops of builder experience or process repetition. Vertically integrated, prefab builders possess the unique ability to leverage learning and repetition to decarbonize their design-build-operate process. This collaboration between Blokable and NREL resulted in a decarbonization strategy utilizing the company's scaling and production efficiencies, on-site renewable energy and storage, and the projected evolution of building components over time based on trends and emerging legislation. The method developed here encompasses a growing business model, lifecycle carbon assessment, and projected changes in product and grid emissions over time due to existing trends and emerging legislation. This methodology incorporates learning-curve efficiencies gleaned from scaled manufacturing, as well as open-source tools integration for energy and carbon accounting. The output projects and compares cost and carbon savings per modular unit as production increases to 10,000 dwelling units annually over 15 years. The resulting roadmap illustrates a path to roughly 60% carbon savings and beyond-net-zero-energy performance at no incremental cost by 2030. The methodology can be mapped to other integrated or productized builders for methodical decarbonization.

affordable housing↗

Effects of the U.S. inflation reduction act on SMR economics

The U.S. Inflation Reduction Act (IRA) of 2022 provides a wide array of tax credits and other incentives for low-carbon energy. The technology-neutral clean generation production tax credit (PTC) (Section 45Y of the U.S. Internal Revenue Code) and the technology-neutral investment tax credit (ITC) (Section 48E) lower the net cost of new electricity generation projects with zero or negative greenhouse gas emission rates. We evaluate the impact of the IRA legislation—specifically the PTC and ITC—on the cost-competitiveness of small modular reactors (SMRs). We use the Argonne Low-carbon Energy Analysis Framework (A-LEAF) model to calculate the capacity factor of an SMR with a range of hypothetical variable operating and maintenance (O&M) costs in the Electric Reliability Council of Texas (ERCOT) electricity market. We selected ERCOT for market modeling because of its competitive structure, available data, and extensive use in prior literature. We use a discounted cash flow model to calculate the SMR’s net present value based on the market prices and capacity factors from A-LEAF, hypothetical ranges of capital and variable O&M costs, and other input parameters, with or without the IRA tax credits. We determine the SMR owner’s optimal choice of PTC or ITC for the hypothetical ranges of capital and variable O&M costs. We also evaluate potential shifts in the SMR owner’s optimal choice of PTC or ITC based on historical patterns of nuclear capital cost overruns in the United States. We also assess the sensitivity of our results to longer PTC period and electricity prices from the New England market, which tend to be higher than electricity prices in ERCOT. We find that even with the IRA tax credits, only SMRs with low capital and variable O&M costs would be economically feasible in the low-price ERCOT market scenario modeled. A longer PTC period and higher-price market such as New England, however, would significantly expand the economic feasibility of SMRs in the United States.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

High Performance Walls in Hot-Dry Climates

High performance walls represent a high priority measure for moving the next generation of new homes to the Zero Net Energy performance level. The primary goal in improving wall thermal performance revolves around increasing the wall framing from 2x4 to 2x6, adding more cavity and exterior rigid insulation, achieving insulation installation criteria meeting ENERGY STAR's thermal bypass checklist. To support this activity, in 2013 the Pacific Gas & Electric Company initiated a project with Davis Energy Group (lead for the Building America team, Alliance for Residential Building Innovation) to solicit builder involvement in California to participate in field demonstrations of high performance wall systems. Builders were given incentives and design support in exchange for providing site access for construction observation, cost information, and builder survey feedback. Information from the project was designed to feed into the 2016 Title 24 process, but also to serve as an initial mechanism to engage builders in more high performance construction strategies. This Building America project utilized information collected in the California project.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Technology Solutions Case Study: High-Performance Walls in Hot-Dry Climates

In this project,the Alliance for Residential Building Innovation (ARBI) team worked with builders in California to implement wall assemblies meeting a U-value lower than 0.050 Btu/h-ft2-°F. ARBI and its project team members helped builders identify preferred wall designs that met the requirements of their architects, structural engineers, and purchasing agents and that were acceptable to their subcontractors. Construction methods were observed and documented and construction costs obtained from builders were used to inform cost estimates for a range of advanced wall system types and insulation types. Wall framing types of 2 × 6 (16- and 24-in. on center [o.c.]) and double stud were modeled in Building Energy Optimization (BEopt™) software with cavity insulation levels ranging from R-19 to R-33 (double stud) and exterior rigid insulation of R-4, R-6, and R-8.

ARBI↗

Equilibrium β-limits in classical stellarators

Here, a numerical investigation is carried out to understand the equilibrium β-limit in a classical stellarator. The stepped-pressure equilibrium code is used in order to assess whether or not magnetic islands and stochastic field-lines can emerge at high β. Two modes of operation are considered: a zero-net-current stellarator and a fixed-iota stellarator. Despite the fact that relaxation is allowed, the former is shown to maintain good flux surfaces up to the equilibrium β-limit predicted by ideal-magnetohydrodynamics (MHD), above which a separatrix forms. The latter, which has no ideal equilibrium β-limit, is shown to develop regions of magnetic islands and chaos at sufficiently high β, thereby providing a ‘non-ideal β-limit’. Perhaps surprisingly, however, the value of β at which the Shafranov shift of the axis reaches a fraction of the minor radius follows in all cases the scaling laws predicted by ideal-MHD. We compare our results to the High-Beta-Stellarator theory of Freidberg and derive a new prediction for the non-ideal equilibrium β-limit above which chaos emerges.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Numerical studies of new stellarator concepts

A three-dimensional computer code has been developed to study the magnetohydrodynamic equilibrium and stability of a diffuse or sharp boundary plasma in toroidal geometry. It is shown how equilibria with net toroidal current identically zero can be determined and how growth rates of instabilities can be calculated. Applications are made to an l = 2, 3 stellarator configuration that offers the possibility of achieving a critical value as high as 10% for the plasma parameter

Bauer, F.↗

Simulation of Thermal Stratification in BWR Suppression Pools with One Dimensional Modeling Method

The suppression pool in a boiling water reactor (BWR) plant not only is the major heat sink within the containment system, but also provides the major emergency cooling water for the reactor core. In several accident scenarios, such as a loss-of-coolant accident and extended station blackout, thermal stratification tends to form in the pool after the initial rapid venting stage. Accurately predicting the pool stratification phenomenon is important because it affects the peak containment pressure; the pool temperature distribution also affects the NPSHa (available net positive suction head) and therefore the performance of the Emergency Core Cooling System and Reactor Core Isolation Cooling System pumps that draw cooling water back to the core. Current safety analysis codes use zero dimensional (0-D) lumped parameter models to calculate the energy and mass balance in the pool; therefore, they have large uncertainties in the prediction of scenarios in which stratification and mixing are important. While three-dimensional (3-D) computational fluid dynamics (CFD) methods can be used to analyze realistic 3-D configurations, these methods normally require very fine grid resolution to resolve thin substructures such as jets and wall boundaries, resulting in a long simulation time. For mixing in stably stratified large enclosures, the BMIX++ code (Berkeley mechanistic MIXing code in C++) has been developed to implement a highly efficient analysis method for stratification where the ambient fluid volume is represented by one-dimensional (1-D) transient partial differential equations and substructures (such as free or wall jets) are modeled with 1-D integral models. This allows very large reductions in computational effort compared to multi-dimensional CFD modeling. One heat-up experiment performed at the Finland POOLEX facility, which was designed to study phenomena relevant to Nordic design BWR suppression pool including thermal stratification and mixing, is used for validation. Comparisons between the BMIX++, GOTHIC, and CFD calculations against the POOLEX experimental data are discussed in detail.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A cost comparison of various hourly-reliable and net-zero hydrogen production pathways in the United States

Hydrogen (H 2 ) as an energy carrier may play a role in various hard-to-abate subsectors, but to maximize emission reductions, supplied hydrogen must be reliable, low-emission, and low-cost. Here, we build a model that enables direct comparison of the cost of producing net-zero, hourly-reliable hydrogen from various pathways. To reach net-zero targets, we assume upstream and residual facility emissions are mitigated using negative emission technologies. For the United States (California, Texas, and New York), model results indicate next-decade hybrid electricity-based solutions are lower cost ($2.02-$2.88/kg) than fossil-based pathways with natural gas leakage greater than 4% ($2.73-$5.94/kg). These results also apply to regions outside of the U.S. with a similar climate and electric grid. However, when omitting the net-zero emission constraint and considering the U.S. regulatory environment, electricity-based production only achieves cost-competitiveness with fossil-based pathways if embodied emissions of electricity inputs are not counted under U.S. Tax Code Section 45V guidance.

08 HYDROGEN↗

Finite-temperature topological order in two-dimensional topological color codes

In this work the topological order at finite temperature in two-dimensional color code is studied. The topological entropy is used to measure the behavior of the topological order. Topological order in color code arises from the colored string-net structures. By imposing the hard constrained limit the exact solution of the entanglement entropy becomes possible. For finite size systems, by raising the temperature, one type of string-net structure is thermalized and the associative topological entropy vanishes. In the thermodynamic limit the underlying topological order is fragile even at very low temperatures. Taking first the thermodynamic limit and then the zero-temperature limit and vice versa does not commute, and their difference is related only to the topology of regions. The contribution of the colors and symmetry of the model in the topological entropy is also discussed. It is shown how the gauge symmetry of the color code underlies the topological entropy.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Recent progress in microscale modeling of RF sheaths

The microscale properties of RF sheaths in the ion cyclotron range of frequencies (ICRF) are investigated by means of analytical theory, nonlinear fluid and particle-in-cell (PIC) code modeling. Previous work that parametrized RF sheath properties, specifically the RF sheath impedance and the rectified (DC) sheath potential, is generalized to include the effect of net DC current flow through the sheath. Analytical results are presented in the low frequency limit where the displacement current is negligible, and tested against results from a fluid numerical model. Here, it is shown that when the sheath draws DC electron current, the voltage rectification is reduced from the zero current case, and the electron admittance is increased. In separate but related work on the microscale model, selected cases have been simulated with PIC codes to validate, further illuminate and extend fluid model results and their parametrizations. Quantitative agreement in trends for voltage rectification and sheath admittance vs. RF driving voltage is found.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Operational Energy Life Cycle Data Development for the National Institute of Standards And Technology (NIST) Building Industry Reporting and Design for Sustainability (BIRDS) Neutral Environmental Software Tool (NEST)

For this analysis, regionalized life cycle assessment (LCA) results for environmental impacts (using the Tool for Reduction and Assessment of Chemicals and Other Environmental Impacts [TRACI] 2.1) and cumulative energy demand (using the Federal Life Cycle Analysis Commons Elementary Flow List [FEDEFL] Inventory Methods v1.0.0) were evaluated for the production and utilization of electricity, natural gas, fuel oil, and propane as commodities within residential and commercial buildings. These results can used as a framework for future research into net zero, high-performance buildings, such as done here for the Building Industry Reporting and Design for Sustainability (BIRDS) database by the National Institute of Standards and Technology (NIST) Engineering Laboratory. The geographical results were assigned to each United States (U.S.) Zone Improvement Plan (ZIP) code based on the ZIP code location and corresponding Balancing Authority Area, natural gas basin, and Petroleum Administration for Defense Districts (PADDs). Additionally, previously developed models were utilized to develop future life cycle profiles. Projections were based on data available from the U.S. Energy Information Administration Annual Energy Outlook 2022 through 2050 (AEO 2022). Electricity LCA models were updated based on AEO 2022 projected annual generation mixes, while the natural gas baseline model was updated based on projected shares of natural gas types (conventional, shale, tight, and coalbed methane). Projections of crude oil production rates and export rates were applied to the petroleum baseline model in five-year increments to investigate their effects on the life cycle profile of fuel oil and propane. While only 100-year Global Warming Potential (GWP-100) with climate carbon feedback (CC-FB) and Cumulative Energy Demand are shown in Section 4: Results, the complete results, including Acidification Potential, Eutrophication Potential, Freshwater Ecotoxicity Potential, GWP-100 without inclusion of CC-FB, Human Health Impacts Potentials (Cancer, Non-Cancer), Ozone Depletion Potential, Particulate Matter Formation Potential, and Photochemical Smog Formation Potential, are tabulated for each ZIP code in the Excel worksheets that accompany this analysis. For the Excel spreadsheet tools associated with this report, please go to https://www.netl.doe.gov/energy-analysis/details?id=f8890fac-be55-44ac-aaa9-e2888bfabe93

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

EUI Benchmarks for Net-Zero Energy Buildings in India

In our study we present EUI benchmarks for NZEBs for six building types across residential and non-residential typologies and for India's five climate zones. This approach is similar to the simulation-based benchmarks used by the B3 program in Minnesota, the Cal-Arch methodology in California, and the US Solar Decathlon approach, which combine simulations with actual building data. Of the six building types we explore one in detail with a range of operation scenarios, specifically narrowing down the EUI benchmarks for mixed-mode building operation and for variable temperature set-points as prescribed in the National Building Code of India.The contribution of this work is to provide rigorous end-use level EUI benchmarks for six building types, and to describe a method for simulation-based EUI benchmarks for mixed-mode operation with variable setpoints to highlight the difference between the standard approach used for the five building types and the On-Site Construction Worker Housing which additionally has the mixed-mode variable setpoint approach.On-Site Construction Worker Housings are typically poorly constructed temporary structures, without adequate thermal comfort, It is critical to provide adequate thermal comfort to protect people from the warming effects of climate change, and to discover super efficient and cost-effective ways to do so.The methodology used for the On-Site Construction Worker Housing (CWH) results in an 80% acceptability according to the India Model for Adaptive Comfort in the National Building Code of India. EUIs of all six buildings are 60% lower than the minimum compliance with India's Energy Conservation Building Codes, providing benchmarks for efficiency levels. The end-use level EUI benchmarks are now provided to over 1800 Solar Decathlon India participants so that they can compare the performance of their NZEB designs.In particular, the CWH results provide an insight into the importance of the mixed-mode operation with variable temperature set-points. The results from the simulation study show that for an NZEB target, the EUI with standard thermal comfort model and without mixed operation is 58.26 kWh/m2*year, while that with the variable set-points of the adaptive model with mixed mode operation is 24.23 kWh/m2*year. This is a 58% reduction in EUI. Given that many building types including residential, and non-residential operate in mixed mode, it is important to take this work further to develop mixed-mode operation NZEB benchmarks so that the carbon intensity of these buildings could be lower than the standard thermal comfort model approach.

benchmarking↗

Gravito-turbulence and dynamo in poorly ionized protostellar discs – I. Zero-net-flux case

In their early stages, protoplanetary discs are sufficiently massive to undergo gravitational instability (GI). This instability is thought to be involved in mass accretion, planet formation via gas fragmentation, the generation of spiral density waves, and outbursts. A key and very recent area of research is the interaction between the GI and magnetic fields in young protoplanetary discs, in particular whether this instability is able to sustain a magnetic field via a dynamo. We conduct 3D, stratified shearing-box simulations using two independent codes, PLUTO and Athena++, to characterize the GI dynamo in poorly ionized protostellar discs subject to ambipolar diffusion. We find that the dynamo operates across a large range of ambipolar Elssaser number Am (which characterizes the strength of ambipolar diffusion) and is particularly strong in the regime Am = 10–100, with typical magnetic to thermal energy ratios of order unity. The dynamo is only weakly dependent on resolution (at least for Am ≲ 100), box size, and cooling law. The magnetic field is produced by the combination of differential rotation and large-scale vertical roll motions associated with spiral density waves. Our results have direct implications for the dynamo process in young protoplanetary discs and possibly some regions of active galactic nucleus discs.

79 ASTRONOMY AND ASTROPHYSICS↗

Phase field-volumetric lattice Boltzmann model of ion uptake in porous nuclear waste form materials under continuous flow

The flow field within the mesopores of sorbent particles plays a crucial role in radionuclide diffusion and ion uptake kinetics, thus, impacting the overall performance of porous nuclear waste form materials. To fundamentally understand the influence of microstructures and material properties on the radionuclide absorption and retention processes requires a coupled multi-physics model that considers the advection and diffusion within the flow field, the reaction at liquid-solid interfaces, and finally, the solid-state diffusion within a complex nanoporous medium. Here, this study employs the volumetric lattice Boltzmann method (VLBM) to accurately and efficiently calculate the steady state velocity field inside the mesopores of sorbent particles. The obtained velocity field is then utilized to calculate the advection of ions in the steady flow. A phase field (PF) model of ion uptake is used to describe the reaction occurring at the solid-liquid interface and diffusion inside the porous medium. The integrated PF-VLBM model is verified in terms of the mass conservation and numerical efficiency and validated qualitatively with experimental observation data. Then, it is applied to study the influence of thermodynamic and kinetic properties, as well as flow field conditions on the ion uptake kinetics. The numerical results demonstrate that the ion uptake kinetics in porous particles has three distinct stages, which is in agreement with the observations in continuous flow experiments. In the first stage, the kinetics is predominantly controlled by the flow field and ion diffusivity in the liquid phase. The kinetics in the second stage is primarily governed by ion diffusivity in the solid phase. In the third stage the system reaches a dynamic equilibrium with a net zero uptake flux at the interface. It is also found that porous structures significantly affect the efficiency and capacity of ion uptake. The simulation results can help to understand the physics behind the observed ion uptake kinetics in experiments and to facilitate the development of constitutive equations that can account for heterogeneous microstructures in engineering performance codes.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗