Search NASA⌕ Search

SEARCH · Search NASA

Results for “neutron transmission”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Neutron-Resonance Transmission Analysis with a Compact Deuterium-Tritium Neutron Generator

Neutron Resonance Transmission Analysis (NRTA) is a spectroscopic technique which uses the resonant absorption of neutrons in the epithermal range to infer the isotopic composition of an object. This spectroscopic technique has relevance in many traditional fields of science and nuclear security. NRTA in the past made use of large, expensive accelerator facilities to achieve precise neutron beams, significantly limiting its applicability. Here, we describe a series of NRTA experiments where we use a compact, low-cost deuterium-tritium (DT) neutron generator to produce short neutron beams (2.6 m) along with a 6 Li-glass neutron detector. The time-of-flight spectral data from five elements – silver, cadmium, tungsten, indium, and 238 U – clearly show the corresponding absorption lines in the 1-30 eV range. The experiments show the applicability of NRTA in this simplified configuration, and prove the feasibility of this compact and low-cost approach. This could significantly broaden the applicability of NRTA, and make it practical and applicable in many fields, such as material science, nuclear engineering, and arms control.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

LANL-TAMUS Graduate Fellowship Report

The goal of this project is to conduct analysis of 147 Sm neutron transmission (n,tot) data at DICER alongside previously collected neutron capture (n,γ) data and report updated resonance parameters and spins. Measurement and analysis of neutron-capture data, without neutron transmission data, has been conducted before and showed that the gamma widths, Γ γ , and neutron widths, Γn, both deviate from the distributions predicted by well-established theory. Γ γ is expected to follow a narrow Gaussian distribution independent of energy but instead a broadening of the distribution around 350 eV incident neutron energy was observed (P. E. Koehler et al. Phys. Rev. C 108, 142502 (2012)). Γ n is predicted to follow a chi-squared distribution with one degree of freedom known as the Porter-Thomas distribution but this prediction also failed above 350 eV incident neutron energy (P. E. Koehler et al. Phys. Rev. C 76, 025804 (2007)). This project seeks to reassess this past measurement by including neutron transmission data and simultaneously analyzing them alongside the neutron capture data to extract the most accurate measure of Γ γ and Γ n ever taken for the resonances of 147 Sm and see if theory holds or fails under a more refined measurement with newer data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Neutron resonance transmission analysis prototype system for thorium fuel cycle safeguards

Emerging thorium-based reactor designs and fuel cycles present challenges to traditional non-destructive assay techniques used in international safeguards. Specifically, assaying the masses of 233 U and 235 U when they are present together in samples with high gamma ray backgrounds is difficult because of similar passive neutron signatures and relatively weak gamma-ray emissions of 233 U. The Pacific Northwest National Laboratory (PNNL) and the Massachusetts Institute of Technology (MIT) are developing a compact neutron resonance transmission analysis (NRTA) system as one potential solution to these challenges. The NRTA technique provides isotopic information for a sample via neutron time-of-flight (TOF) measurements that exploit a sample’s epithermal neutron resonance cross-sections. A recently developed portable NRTA system uses a commercially available, pulsed deuterium-tritium neutron generator with a ~2 m flight path and a GS20 lithium glass scintillator detector. Finally, this paper describes the prototype NRTA system design, a refined radiation transport model of the system, preliminary measurements with thorium and uranium sources, and demonstration of a quantitative isotopic estimation algorithm.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

3D isotope density measurements by energy-resolved neutron imaging

Abstract Tools for three-dimensional elemental characterization are available on length scales ranging from individual atoms, using electrons as a probe, to micrometers with X-rays. However, for larger volumes up to millimeters or centimeters, quantitative measurements of elemental or isotope densities were hitherto only possible on the surface. Here, a novel quantitative elemental characterization method based on energy-resolved neutron imaging, utilizing the known neutron absorption cross sections with their ‘finger-print’ absorption resonance signatures, is demonstrated. Enabled by a pixilated time-of-flight neutron transmission detector installed at an intense short-pulsed spallation neutron source, for this demonstration 3.25 million state-of-the-art nuclear physics neutron transmission analyses were conducted to derive isotopic densities for five isotopes in 3D in a volume of 0.25 cm 3 . The tomographic reconstruction of the isotope densities provides elemental maps similar to X-ray microprobe maps for any cross section in the probed volume. The bulk isotopic density of a U-20Pu-10Zr-3Np-2Am nuclear transmutation fuel sample was measured, agrees well with mass-spectrometry and is evidence of the accuracy of the method.

36 MATERIALS SCIENCE↗

Constraining the nuclear spin distribution using improved 197 Au neutron resonance parameters

New neutron transmission data at resonance energies using a 197 Au sample were measured using an early version of the Device for Indirect Capture Experiments on Radionuclides (DICER), which is under development at the Los Alamos Neutron Science Center (LANSCE). These data were combined with previous neutron transmission and capture data in a simultaneous R-matrix analysis to extract improved neutron resonance parameters for this nuclide. As a result, total radiation widths, Γ γ , were obtained for 33 J=1 and 44 J=2 197 Au+n resonances. Γ γ distributions for these two spins states were compared to distributions calculated according to the nuclear statistical model using published nuclear level density (NLD) and photon strength functions (PSF) measured using the Oslo technique. The calculated distributions were found to be narrower and the average values for the two spins states closer together than the data. The calculation can be brought into agreement with the data by substantial modifications to the spin distribution in 198 Au as a function of excitation energy. As far as we know, the spin distribution currently is otherwise poorly constrained. The modified spin distribution changes the shapes of the NLD and PSF extracted using the Oslo technique and so could have broad implications.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Bragg edge imaging (BEI) of B12W and M8N socket sections of the Arecibo telescope

From neutron user principal investigator: We kindly request the public release of three neutron imaging datasets through ONCat. All datasets were collected from two forensic specimens, B12W and M8N, sectioned from zinc-filled steel-wire sockets recovered from the collapsed Arecibo Telescope. The dataset titled “Neutron radiographs of B12W and M8N socket sections of the Arecibo telescope” contains normalized two-dimensional (2D) neutron radiographs of the specimens, showing the geometry and spatial distribution of the steel wires embedded within the zinc matrix, as well as internal features such as voids and cracks. The dataset titled “Neutron computed tomography of B12W and M8N socket sections of the Arecibo telescope” contains normalized 2D neutron projection images acquired over a range of specimen rotation angles for one selected region of each specimen. These projection images were used to reconstruct three-dimensional (3D) tomographic volumes that reveal the embedded-wire geometry and internal defects. The dataset titled “Bragg edge imaging (BEI) of B12W and M8N socket sections of the Arecibo telescope” contains six time-of-flight (TOF) neutron imaging datasets, three from each specimen, acquired at regions of interest selected based on the radiographs. The spatially resolved 2D TOF images show the zinc matrix and embedded steel wires, and the wavelength-dependent neutron transmission data were used to characterize crystallographic texture within the zinc. All components and their condition are in the public domain as they are the property of the National Science Foundation (NSF). The neutron imaging data, part geometries, and detailed forensic information have been widely published in the Arecibo Telescope Collapse Forensic Report by Thornton Tomasetti Engineers and others (NASA report and NASEM report).

Bilheux, Hassina↗

New capability for indirect neutron capture measurements: The DICER instrument at LANSCE

The Device for Indirect Capture on Radionuclides (DICER) implements a new indirect technique for (n,γ) studies in which the neutron capture rate is determined from analysis of resonance neutron transmission data. The DICER instrument and associated radionuclide production at the Isotope Production Facility (IPF), both at the Los Alamos Neutron Science Center (LANSCE), as well radioactive sample fabrication, have been under development in the last few years. First measurements on a radioactive sample ( 88 Zr, t ½ =83.4 days), which was recently reported to have an extremely large thermal neutron capture cross section and resonance integral, are planned for the winter of 2021. A performance overview, brief details on the 88Zr fabrication and proof of good operation results will be presented.

47 OTHER INSTRUMENTATION↗

Time-Resolved Neutron Imaging for Hydrogen Uptake in Subsurface Lithologies

Geologic hydrogen production and underground storage are increasingly important for meeting rising energy demands while providing clean-combustion advantages. However, hydrogen’s high diffusivity and propensity for leakage through porous media necessitate direct evaluation of its transport behavior in subsurface materials. Whereas X-ray microcomputed tomography (μCT) studies often employ contrast agents or surrogate gases, this study leverages neutron transmission radiography/CT to observe hydrogen migration in situ. This work represents the first demonstration of real-time neutron radiography of hydrogen migration in reservoir and caprock lithologies. Cylindrical cores of Indiana limestone, Amherst Gray sandstone, and Tumey shale were subjected to constant-pressure hydrogen charging and scanned in real time using high-resolution neutron radiography. Results indicate immediate hydrogen infiltration in sandstone and limestone, with homogeneous distribution detected throughout their pore structure. In contrast, hydrogen remained largely absent from fine-grained shale under the same pressure, except in an apparently localized fracture zone, where neutron signatures confirmed the presence of hydrogen. Subsequent neutron CT of the sandstone sample, using image subtraction against an uncharged reference, corroborated hydrogen distribution patterns. Even under lowpressure, single-phase conditions, distinct neutron imaging signatures of hydrogen were achieved. These preliminary findings underscore the potential of neutron imaging for advancing subsurface hydrogen migration research.

08 HYDROGEN↗

Polarized neutron measurements of the internal magnetization of a ferrimagnet across its compensation temperature

We present the first polarized neutron transmission image of a model Néel ferrimagnetic material, polycrystalline terbium iron garnet (Tb 3 Fe 5 O 12 , TbIG for short), as it is taken through its compensation temperature T comp where the macroscopic magnetization vanishes. Our polarized neutron imaging data and the additional supporting measurements using neutron spin echo spectroscopy and SQUID magnetometry are all consistent with a vanishing internal magnetization at T comp .

Ferrimagnetism↗

Update on NNL TSL Validation Efforts [Slides]

This presentation covers how a new sub-thermal neutron transmission capability at RPI LINAC is now in use to help validate TSL evaluations. Additionally, NNL has contributed multiple material evaluations to ENDF/B-VIII.1. Lastly, this presentation covers new methods to improve TSL physics and accuracy are being formulated.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Update on NNL TSL Validation Efforts [Slides]

A new sub-thermal neutron transmission capability at RPI LINAC has been used to validate Be (metal). NNL transmission measurements validated NCSU Be and Be+Sd TSLs for ENDF/B-VIII.1 and showed improvements WRT ENDF/B-VII.1 and ENDF/B-VIII.0. Amplitude differences highlighted the importance of sample characterization. Additional measurement is in progress for CY2022. PNDA is being developed as an alternative to critical experiment validation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

New Measurements to Resolve Discrepancies in Evaluated Model Parameters of 181 Ta

To resolve discrepancies in evaluated cross sections among major nuclear data libraries, energy-differential neutron transmission and radiative capture yield of 181 Ta were measured from 0.15 to 100 keV using multiple sample thicknesses. The new measurements provide resolution such that the resolved resonance region (RRR) can be evaluated up to at least 2.5 keV and the unresolved resonance region can be evaluated up to at least 100 keV. The transmission and capture yield measurements were modeled using resonance parameters from three major libraries to assess the predictive capability of each. It was found that JENDL-5.0 performed best in the RRR. Because of the poor performance of the U.S. ENDF/B evaluation, it is recommended that ENDF/B be reevaluated for 181 Ta.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

3D Tomography and Image Processing Using Fast Neutrons Final Report

This document is the final report for project OR16-ML-3DTomography-PD3Jb, “3D Tomography and Image Processing Using Fast Neutrons.” This project was motivated by the availability of three-dimensional (3D) tomographic neutron transmission and induced-reaction data following the development of associated-particle imaging (API) systems with two-dimensional (2D) or “area” neutron detectors such as the Advanced Portable Neutron Imaging System, which is capable of simultaneous measurement of transmission and induced-reaction neutrons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A novel compact end-loaded piston cylinder cell for high pressure neutron scattering up to 5 GPa

Here, a miniature sized end-loaded piston cylinder cell with radial side windows for neutron scattering experiments is described. The principle of the bicone-shaped cylinders used was first presented by McWhan in 1974. The present cell is of compact portable design yet significantly enlarges the scattering angles. Its small size allows neutron scattering experiments at low temperatures. The bicone-shaped cylinders are made from various ceramics or a highly neutron-transmissive Ni-free Cr–Mo–V steel. Successful neutron scattering experiments up to 5 GPa have been demonstrated on the CORELLI single-crystal diffractometer and the VISION vibrational spectrometer of the Spallation Neutron Source at the Oak Ridge National Laboratory.

Neutrons↗

Temperature-dependent transmission and self-indication measurements upon depleted U in the unresolved region

Neutron transmission and self-indication ratio measurements have been carried out at the RPI LINAC on depleted U up to 100 KeV in order to investigate the temperature dependence of resonance self-shielding. These measurements were performed at three sample temperatures (77 deg k, 295 deg k, and 973 deg k) and with sample thicknesses ranging from 0.0076 to 0.0621 atom/barn. Both stochastic sampling and analytical methods have been used to interpret these data. Average resonance parameters have been obtained and temperature dependence as well as sample thickness dependence of the data have been extensively studied.

Byoun, T. Y.↗

Iterative Reconstruction for Multimodal Neutron Tomography

Here, we describe a unified framework for model-based iterative 3-D reconstruction of multimodal neutron transmission, hydrogen-scatter, and induced-fission images from low resolution data recorded using 14.1-MeV neutrons and the associated-particle imaging (API) technique. The framework, which was developed to facilitate use in challenging field-deployment scenarios, is centered around physics-based system models and a total variation (TV) constrained implementation of the simultaneous iterative reconstruction technique (SIRT). Modified to solve a statistically weighted least squares (WLS) problem, the SIRT algorithm is accelerated using ordered subsets and Nesterov’s momentum for which we derive a near-optimal value of the governing Lipschitz constant. The approach enables the reconstruction of images that are high resolution compared to the acquired data and is robust to both limited statistics and a limited number of projection angles. Moreover, the framework is fast enough to be practical. Example images are provided that demonstrate both the ability to perform fast-neutron imaging of high-atomic-number materials with low radiation dose and the benefit of multimodal neutron imaging to identify key materials.

Hydrogen scatter↗