Search NASA⌕ Search

SEARCH · Search NASA

Results for “nitrogen adsorption”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Alteration of an annealed and irradiated lunar fines sample by adsorbed water

Apollo 12 lunar fines sample 12070,403 was annealed at 1000 C and subsequently irradiated with a beam of 130 MeV Fe(9+) ions. Adsorptions of nitrogen and water were measured before and after the irradiation. Prior to the irradiation, the fines were nonporous and water had no effect on the physical characteristics of the lunar fines. In contrast, after the irradiation, the interaction with water caused an increase in the specific surface area and created a pore system. These results are definitive evidence that the interaction of water with damage tracks is the prime factor involved in the alteration of lunar fines by adsorbed water.

Holmes, H. F.↗

Surface properties of a north ray crater soil /Apollo 16/

Surface properties of lunar fines sample 67481 have been investigated by measuring the adsorptions of nitrogen (at -196 C) and water (at 20 C). Characteristics of this sample are similar to those of samples from other locations on the lunar surface and include the more typical alteration reaction with adsorbed water. Although their maturities are markedly different, the surface properties of 67481 are very much like those of the more mature 63341 from the adjacent station 13. These results indicate that the surface properties of lunar soils attain an equilibrium state faster than other properties used to indicate maturity.

Holmes, H. F.↗

A surface chemistry model for the altitude dependence of the N2 Lyman-Birge-Hopfield glow on spacecraft

Low-orbiting spacecraft have been observed to cause UV emission in the N2 Lyman-Birge-Hopfield bands. The chemical processes expected to underlie this emission are examined. Recombination between incident and adsorbed N atoms has been proposed as the source of radiating excited N2. However, the cubic dependence of the intensity, as N2 concentration cubed or N2 concentration squared x O concentration, has not been explained. It is suggested that this can be explained by a model where adsorption of nitrogen on the spacecraft surface is balanced mainly by the removal of N from the surface by atomic oxygen. On the basis of these assumptions a mathematical model for the production of excited N2 is constructed. It is shown that for large enough reaction efficiencies the model predicts a magnitude and altitude dependence for the emission which can explain the measurements reported by other investigators.

Cuthbertson, J. W.↗

A 99 percent purity molecular sieve oxygen generator

Molecular sieve oxygen generating systems (MSOGS) have become the accepted method for the production of breathable oxygen on military aircraft. These systems separate oxygen for aircraft engine bleed air by application of pressure swing adsorption (PSA) technology. Oxygen is concentrated by preferential adsorption in nitrogen in a zeolite molecular sieve. However, the inability of current zeolite molecular sieves to discriminate between oxygen and argon results in an oxygen purity limitations of 93-95 percent (both oxygen and argon concentrate). The goal was to develop a new PSA process capable of exceeding the present oxygen purity limitations. A novel molecular sieve oxygen concentrator was developed which is capable of generating oxygen concentrations of up to 99.7 percent directly from air. The process is comprised of four absorbent beds, two containing a zeolite molecular sieve and two containing a carbon molecular sieve. This new process may find use in aircraft and medical breathing systems, and industrial air separation systems. The commercial potential of the process is currently being evaluated.

Miller, G. W.↗

Fluids and their Effect on Measurements on Lunar Soil Particle size Distribution

From the late 1960s until now, lunar soil particle size distributions have typically been determined by sieving sometimes dry, and at other times with fluids such as water or Freon. Laser diffraction instruments allow rapid assessment of particle size distribution, and eventually may replace sieve measurements. However, when measuring lunar soils with laser diffraction instruments, care must be taken in choosing a carrier fluid that is compatible with lunar material. Distilled water is the fluid of choice for laser diffraction measurements of substances when there is no concern about adverse effects of water on the material being measured. When we began our analyses of lunar soils using laser diffraction, our first measurements were made with distilled water. Although the medians that we measured were comparable to earlier sieve data, the means tended to be significantly larger than expected. The effect of water vapor on lunar soil has been studied extensively. The particles interact strongly with water vapor, and subsequent adsorptions of nitrogen showed that the specific surface area increased as much as threefold after exposure to moisture. It was observed that significant porosity had been generated by this exposure to water vapor. The possibility of other physical changes in the surfaces of the grains was not studied.

Cooper, B. L.↗

Xplo-SA9T: Optimization of Sorbent Technology With Existing and New Amine Variants for Carbon Dioxide Removal and Humidity Control

Scrubbing of the spacesuit air stream to control humidity and regulate carbon dioxide (CO 2 ) relies on amine-loaded resins, colloquially known as sorbents. The efficacy of Rapid Cycle Amine technology relies on the propensity of nitrogens toward adsorption of CO 2 while simultaneously offering regenerative properties under vacuum or positive pressure. The commonly utilized sorbent, SA9T, was recreated and evaluated further to increase stability and serve as a benchmark comparison for newly synthesized amine sorbent technologies. Ongoing storage studies with eight different environments will allow the development of applicable storage protocols and provide insight into possible ammonia generation pathways. Attempts to alleviate the known issues with SA9T included the alteration of the primary amine (tetraethylenepentamine), the choice of resin, and the particle size distribution. In-house CO 2 breakthrough experiments were conducted using a specialized apparatus that can simulate spacesuit conditions, offering high-quality triplicate capacity analysis affording direct comparison to known adsorbents in the literature. Thermo-Desorption Gas Chromatography Mass Spectrometry studies on the synthesized materials revealed any reagent or solvent offgassing while Nuclear Magnetic Resonance spectroscopy tracked the stability of the bound amine. Scanning Electron Microscope images of sieved materials provided a more accurate size interpretation facilitating synthetic design and pressure drop elimination. All efficient sorbents were synthesized to a commercial batch scale subsequent to evaluation including Xplo-SA9T.

John R Tidwell↗

Fractionation of nitrogen isotopic on Mars: The role of the regolith as a buffer

We have measured the adsorption of molecular nitrogen (N2) on palagonite, and modeled the adsorbed nitrogen inventory on the martian regolith. We were motivated by the fact that models of isotopic evolution predict stronger N2 fractionation than reported by Viking. Possible scenarios for reconciling models with the observation include a heavy CO2 atmosphere early in the planet's history, continued outgassing of N2 throughout the history of Mars, or a substantial adsorbed inventory. In this paper we investigate the plausibility of the last explanation. We find that the regolith reservoir of adsorbed N2 is inadequate by itself to buffer the atmospheric isotopic composition, but may play a role depending on the total regolith surface area available.

Zent, A. P.↗

Advanced optical smoke meters for jet engine exhaust measurement

Smoke meters with increased sensitivity, improved accuracy, and rapid response are needed to measure the smoke levels emitted by modern jet engines. The standard soiled tape meter in current use is based on filtering, which yields long term averages and is insensitive to low smoke levels. Two new optical smoke meter techniques that promise to overcome these difficulties have been experimentally evaluated: modulated transmission (MODTRAN) and photothermal deflection spectroscopy (PDS). Both techniques are based on light absorption by smoke, which is closely related to smoke density. They are variations on direct transmission measurements which produce a modulated signal that can be easily measured with phase sensitive detection. The MODTRAN and PDS techniques were tested on low levels of smoke and diluted samples of NO2 in nitrogen, simulating light adsorption due to smoke. The results are evaluated against a set of ideal smoke meter criteria that include a desired smoke measurement range of 0.1 to 12 mg cu.m. (smoke numbers of 1 to 50) and a frequency response of 1 per second. The MODTRAN instrument is found to be inaccurate for smoke levels below 3 mg/cu.m. and is able to make a only about once every 20 seconds because of its large sample cell. The PDS instrument meets nearly all the characteristics of an ideal smoke meter: it has excellent sensitivity over a range of smoke levels from 0.1 to 20 mg/cu.m. (smoke numbers of 1 to 60) and good frequency response (1 per second).

Pitz, R. W.↗

The oxidation of titanium films saturated with nitrogen at 300 K

In a two-chamber system designed for physical adsorption studies, a titanium film was deposited and exposed to nitrogen. Oxygen was then admitted into the system. However, the presence of oxygen could not be detected by the mass spectrometer during the first 300 seconds of oxygen admission. On the basis of the data it is assumed that the capture probability of the nitrogen-saturated titanium film for oxygen is very nearly 1. Based on this assumption, the titanium film adsorbed approximately 3 monolayers of oxygen.

Outlaw, R. A.↗

Adsorption of H2, Ne, and N2 on Activated Charcoal

9-page report presents measured adsorption isotherms of hydrogen, neon, and nitrogen on activated charcoal for temperatures from 77 to 400 K and pressures from 1 to 80 atmospheres (0.1 to 8.1 MPa). Heats of adsorption calculated from isotherms also presented. Report gives expressions, based on ideal-gas law, which show relationship between different definitions of volume of gas adsorbed and used in describing low-pressure isotherms.

Chang, C. K.↗

CO2 Acquisition Membrane (CAM)

The objective of CAM is to develop, test, and analyze thin film membrane materials for separation and purification of carbon dioxide (CO2) from mixtures of gases, such as those found in the Martian atmosphere. The membranes are targeted toward In Situ Resource Utilization (ISRU) applications that will operate in extraterrestrial environments and support future unmanned and human space missions. A primary application is the Sabatier Electrolysis process that uses Mars atmosphere CO2 as raw material for producing water, oxygen, and methane for rocket fuel and habitat support. Other applications include use as an inlet filter to collect and concentrate Mars atmospheric argon and nitrogen gases for habitat pressurization, and to remove CO2 from breathing gases in Closed Environment Life Support Systems (CELSS). CAM membrane materials include crystalline faujasite (FAU) zeolite and rubbery polymers such as silicone rubber (PDMS) that have been shown in the literature and via molecular simulation to favor adsorption and permeation of CO2 over nitrogen and argon. Pure gas permeation tests using commercial PDMS membranes have shown that both CO2 permeance and the separation factor relative to other gases increase as the temperature decreases, and low (Delta)P(Sub CO2) favors higher separation factors. The ideal CO2/N2 separation factor increases from 7.5 to 17.5 as temperature decreases from 22 C to -30 C. For gas mixtures containing CO2, N2, and Ar, plasticization decreased the separation factors from 4.5 to 6 over the same temperature range. We currently synthesize and test our own Na(+) FAU zeolite membranes using standard formulations and secondary growth methods on porous alumina. Preliminary tests with a Na(+) FAU membrane at 22 C show a He/SF6 ideal separation factor of 62, exceeding the Knudsen diffusion selectivity by an order of magnitude. This shows that the membrane is relatively free from large defects and associated non-selective (viscous flow) transport mechanisms. The Membrane Test Facility (MTF) has been developed to measure membrane permeance over a wide range of temperature and pressure. The facility uses two volume compartments separated by the membrane that are instrumented to measure temperature, delta pressure across the membrane, and gas composition. A thermal shroud supports and encloses the membrane, and provides temperature control. Methods were developed to determine membrane permeance using the first order decay of the pressure difference between the sealed compartments, using the total pressure for pure gases, and partial pressure of each species in gas mixtures. The technique provides an end-to-end measurement of gas permeance that includes concentration polarization effects. Experiments have shown that in addition to membrane permeance properties, the geometry and design of associated structures play an important role in how membrane systems will function on Mars.

Mason, Larry W.↗

Some surface characteristics and gas interactions of Apollo 14 fines and rock fragments.

Comprehensive survey of the physical surface characteristics of Apollo 14 fines, two fragments of a breccia (14321), and a crystalline rock (14310). The survey was carried out with optical and both scanning and transmission electron microscopy and by studying the adsorption of a variety of gases including nitrogen, hydrogen, and water vapor. Our objective in the optical microscope study was to relate the visible geological and petrological features to the surface properties. Electron microscopy particularly helped relate surface roughness and particle fusion to gas adsorption and pore structure. The fine sample (14163,111) had a surface area of 0.210 sq m/g and a helium density of 2.9 g/cc. Similar values have been observed with breccia fragments. Other observations include physical adsorption of molecular hydrogen at low temperatures and of water vapor at ambient temperatures. It is concluded that these particular lunar materials, while capable of adsorbing water vapor, do not retain it for any significant time at low pressures, nor, under lunar conditions, is there any indication of absorption or penetration.

Cadenhead, D. A.↗

Experimental and Numerical Investigation of Adsorption/Desorption in Packed Sorption Beds Under Ideal and Non-Ideal Flows

The importance of the wall effect on packed beds in the adsorption and desorption of carbon dioxide, nitrogen, and water on molecular sieve 5A of 0.127 cm in radius is examined experimentally and with one-dimensional computer simulations. Experimental results are presented for a 22.5-cm long by 4.5-cm diameter cylindrical column with concentration measurements taken at various radial locations. The set of partial differential equations are solved using finite differences and Newman's method. Comparison of test data with the axial-dispersed, non-isothermal, linear driving force model suggests that a two-dimensional model (submitted to Separation Science and Technology) is required for accurate simulation of the average column breakthrough concentration. Additional comparisons of test data with the model provided information on the interactive effects of carrier gas coadsorption with CO2, as well as CO2-H2O interactions.

Mohamadinejad, H.↗

Performance of Adsorption - Based CO2 Acquisition Hardware for Mars ISRU

Chemical processing of the dusty, low-pressure Martian atmosphere typically requires conditioning and compression of the gases as first steps. A temperature-swing adsorption process can perform these tasks using nearly solid-state hardware and with relatively low power consumption compared to alternative processes. In addition, the process can separate the atmospheric constituents, producing both pressurized CO2 and a buffer gas mixture of nitrogen and argon. To date we have developed and tested adsorption compressors at scales appropriate for the near-term robotic missions that will lead the way to ISRU-based human exploration missions. In this talk we describe the characteristics, testing, and performance of these devices. We also discuss scale-up issues associated with meeting the processing demands of sample return and human missions.

Finn, John E.↗

Co-Adsorption of Carbon Dioxide on Zeolite 13X in the Presence of Preloaded Water

Background: Carbon Dioxide removal is a key aspect of Life Support for long-duration missions - Need to improve Mass, Power, and Volume of systems; Cabin air has three major constituents - Oxygen and Nitrogen, Carbon dioxide (CO2), Water Vapor; The mechanism for strong CO2 adsorption in zeolites (and many sorbents) is also the same mechanism for H2O - Water vapor is selectively adsorbed over CO2.

Cmarik, Gregory E.↗