Search NASA⌕ Search

SEARCH · Search NASA

Results for “non-destructive diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

29 records · Page 2

Virtual Diagnostic Suite for Electron Beam Prediction and Control at FACET-II

We discuss the implementation of a suite of virtual diagnostics at the FACET-II facility currently under commissioning at SLAC National Accelerator Laboratory. The diagnostics will be used for the prediction of the longitudinal phase space along the linac, spectral reconstruction of the bunch profile, and non-destructive inference of transverse beam quality (emittance) while using edge radiation at the injector dogleg and bunch compressor locations. These measurements will be folded into adaptive feedbacks and Machine Learning (ML)-based reinforcement learning controls to improve the stability and optimize the performance of the machine for different experimental configurations. In this paper we describe each of these diagnostics with expected measurement results that are based on simulation data and discuss progress towards implementation in regular operations.

Emma, Claudio (ORCID:0000000247191831)↗

Implementation of a 1550-nm laser system for beam characterization at the Argonne Wakefield Accelerator

Accurately recording an electron bunch’s longitudinal profile is an important diagnostic for wakefield accelerators employing shaped bunches to increase transformer ratios. Electro-optic sampling of terahertz radiation from the bunch is an attractive approach due to its non-destructive nature. In preparation for future characterization experiments, the Argonne Wakefield Accelerator test facility has recently installed a 1550 nm laser system, including the necessary support systems to synchronize with the photoinjector laser system at 81.25 MHz. We report here on the initial installation and synchronization demonstrations.

Ody, Alexander [Argonne, PHY]↗

Non-destructive identification of absorptive damage sites by photoluminescence brightening

We present a non-destructive photoluminescence (PL) imaging strategy for probing damage growth behavior in fused silica under laser irradiation. Transient wide-field PL image measurements were conducted at varying excitation intensities to investigate the dynamics of radiative defect generation and annihilation in laser-induced damage sites. Our results reveal that, while low excitation intensities predominantly induce PL quenching due to defect annihilation, high-intensity excitation (>0.3 GW/cm 2 at 532 nm) triggers pronounced PL brightening (PLB), indicative of radiative defect generation. Image analysis demonstrates that PLB events are strongly correlated with subsequent damage growth (10 J/cm 2 at 351 nm), whereas overall PL intensity is not. No optically detectable morphological changes were observed during PLB, confirming the non-destructive nature of the technique. We propose that PLB arises from defect-assisted absorption of multiple photons at pre-existing absorptive centers, which enhances local absorptivity and initiates further defect formation. These findings establish PLB monitoring as a sensitive diagnostic tool for identifying damage sites with elevated absorptivity, enabling targeted maintenance and improved laser damage management in optical materials.

Materials science↗

Diagnosing nuclear power plant pipe wall thinning due to flow accelerated corrosion using a passive, thermal non-destructive evaluation method: Feasibility assessment via numerical experiments

Flow accelerated corrosion (FAC) in nuclear power plant pipes is one of the leading causes of accidents, fatalities, damage and outages. Current FAC identification methods employ expensive sensing technology and are “active” methods, where the response of the piping system to an externally-generated thermal, mechanical or optical excitation must be measured. As a result, these techniques require a disruptive and time-consuming setup. Here we propose a method that utilizes pipe surface temperature measurements to passively monitor for FAC-induced pipe wall thinning without the need for expensive equipment or post-installation setup time. This diagnostic method utilizes a simulation data-driven diagnostic model to estimate the amount of thickness reduction in a pipe based on changes in measured steady-state pipe temperatures. In order to reduce the computational burden of generating large, simulation-based datasets, the behavior of the insulation of the pipe was modeled using a suitably calibrated heat transfer boundary parameter. Additionally, global sensitivity analysis was performed to determine system parameter(s), such as the temperature of water flowing inside the pipe, which significantly affect the steady state pipe wall temperature and could cause errors in diagnosis. Two diagnostic models, one using only the change in steady-state temperature as an indicator for FAC-induced pipe wall thinning and the other using water temperature as an additional diagnostic model input were evaluated for their ability to estimate thickness reductions in a pipe using simulated pipe wall temperature data. For the numerical experiments conducted in this work, both models estimated wall thickness with errors within 0.5 mm, indicating that the proposed technique can potentially be used as a low-cost, first-pass method for FAC monitoring.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Through-Thickness Microstructure Characterization in a Centrifugally Cast Austenitic Stainless Steel Nuclear Reactor Primary Loop Pipe Using Time-of-Flight Neutron Diffraction

The US code of Federal Regulations mandates regular inspection of centrifugally cast austenitic stainless steel pipe, commonly used in primary cooling loops in light-water nuclear power plants. These pipes typically have a wall thickness of ~8 cm. Unfortunately, inspection using conventional ultrasonic techniques is not reliable as the microstructure strongly attenuates ultrasonic waves. Work is ongoing to simulate the behavior of acoustic waves in this microstructure and ultimately develop an acoustic inspection method for reactor inspections. In order to account for elastic anisotropy in the material, the texture in the steel was measured as a function of radial distance though the pipe wall. Experiments were conducted on two 10 × 12.7 × 80 mm radial sections of a cast pipe using neutron diffraction scans of 2 mm slices using the HIPPO time-of-flight neutron diffractometer at the Los Alamos Neutron Science Center (LANSCE, Los Alamos, NM, USA). Strong textures dominated by a small number of austenite grains with their (100) direction aligned in the radial direction of the pipe were observed. ODF analysis indicated that up to 70% of the probed volume was occupied by just three single-grain orientations, consistent with grain sizes of almost 1 cm. Texture and phase fraction of both ferrite and austenite phases were measured along the length of the samples. These results will inform the development of a more robust diagnostic tool for regular inspection of this material.

42 ENGINEERING↗

Comprehensive defect evaluation of advanced nuclear fuels using high-resolution acoustic signals and optimized sensor separation

Graphite pebble composite structures based on TRistructural-ISOtropic (TRISO) particles are being developed as core nuclear fuels in advanced power reactors, promising safe operation at increased temperatures. Ensuring the structural integrity of these nuclear fuels requires comprehensive and accurate non-destructive evaluation (NDE) techniques to characterize defects and damage in the pebbles. However, traditional acoustic evaluation methods face limitations in defect characterization due to the highly attenuative, and geometrically and compositionally complex nature of these structures. This study proposes an improved acoustic NDE technique for accurate detection and classification of anticipated relevant defects and damage in graphite pebbles using high-resolution acoustic signals and optimized transmit-receive sensor networks. The proposed approach utilizes a triangular three-sensor network as the base unit, comprising three transmit-receive sensors. The sensor separation distance, as well as acoustic excitation center frequency, pulse-width, and bandwidth are optimized to enhance spatial resolution and improve signal-to-noise ratio, enabling effective characterization of the smallest size and widest range of defects in pebbles. Furthermore, the use of the triangular sensor configuration instead of a more conventional transmit-receive sensor pair expands the inspection region from a one-dimensional linear path to a two-dimensional area, increasing spatial coverage. To mitigate challenges associated with processing of complex acoustic signals arising from high-frequency, high-bandwidth excitation in these structures, a machine-learning-based signal processing algorithm is integrated with the sensor network. In the machine-learning-based algorithm, multi-domain features are extracted from the acoustic signals to capture intricate signal characteristics, significantly improving defect identification and classification compared to traditional approaches. The proposed acoustic NDE technique offers considerable promise for practical and reliable defect/damage diagnostics of advanced nuclear pebble fuels.

42 ENGINEERING↗

FTIR imaging identifies alterations in lung tissue structure and biochemical composition in human idiopathic pulmonary fibrosis

Idiopathic Pulmonary Fibrosis (IPF) is a chronic, progressive, and fatal lung disease characterized by damage to the epithelial tissue and a reduced ability of the alveoli to repair themselves. This impaired repair process leads to abnormal accumulation of extracellular matrix (ECM), resulting in scarring and stiffening of lung tissue. Fourier transform infrared imaging (FTIRI) is a promising technique for imaging the biochemical changes related to fibrotic changes in a label-free and non-destructive manner, which can be analyzed to mark the progression of IPF. In this study, FTIRI was used to image human lung tissue biopsies with IPF and control biopsies without disease. In-depth spectral analyses were performed to observe the biochemical changes in the tissue composition using FTIRI. The parameters that were analyzed included collagen structure, total lipid content, lipid chain length, and phospholipids. Results showed a significant increase in lipid content in IPF compared to control, where long chain lipids dominated and phospholipids were reduced. Minor changes in collagen structure were also observed in IPF, likely attributed to the excess formation of extracellular matrix in the disease. These findings indicate that FTIRI has the potential to be a promising diagnostic technique to understand the molecular changes during IPF, as analysis of infrared data can reveal detailed biochemical information regarding disease progression and provide spatial insights on the molecular changes across the IPF lung tissue.

59 BASIC BIOLOGICAL SCIENCES↗

Femtosecond Reflectance Spectroscopy for Energetic Material Diagnostics

Understanding the fundamental mechanisms underpinning shock initiation is critical to predicting energetic material (EM) safety and performance. Currently, the timescales and pathways by which shock-excited lattice modes transfer energy into specific chemical bonds remains an open question. Towards understanding these mechanisms, our group has previously measured the vibrational energy transfer (VET) pathways in several energetic thin films using broadband, femtosecond transient absorption spectroscopy. However, new technologies are needed to move beyond these thin film surrogates and measure broadband VET pathways in realistic EM morphologies. Herein, we describe a new broadband, femtosecond, attenuated total reflectance spectroscopy apparatus. Performance of the system is benchmarked against published data and the first VET results from a pressed EM pellet are presented. This technology enables fundamental studies of VET dynamics across sample configurations and environments (pressure, temperature, etc .) and supports the potential use of VET studies in the non-destructive surveillance of EM components.

42 ENGINEERING↗

Methods for estimating X-ray machine output through measurement and simulation

We report ball grid arrays are increasingly being applied in the electronics industry and may require X-ray inspection to ensure the integrity and correct placement of solder pins. However, as the architecture of integrated circuits continues to narrow while simultaneously growing more complex, the risk of electronic failure due to radiation damage increases. While medical X-ray devices have been held to high standards and are repeatedly shown to be well characterized, devices used for electronic inspection are often lacking detailed characterization. This study presents unique methods to solve for important properties in X-ray inspection devices such as source to object distance and energy spectrum. This information can then be applied to Monte Carlo models to achieve better overall dose estimates to electronics, which will lead to superior manufactured products. Since X-ray devices can vary greatly in source characteristics, this work investigates spectral measurement and Monte Carlo representation of three X-ray devices. For a Philips SRO 33 100 medical diagnostic device, the spectral output followed expected trends given by the prediction software SpekCalc and Spektr. For the Dage XD7500NT, direct measurement showed a spectral artifact that through the use of Gafchromic films, was shown to be a contributing effect in the dose output. For the Rad Source RS1800, a high powered irradiation device, direct spectral measurement was not achieved. However, a Monte Carlo model using an assumed spectra was found to match ion chamber measurements to a high degree.

47 OTHER INSTRUMENTATION↗

Bridging Nano- and Microscale X-Ray Tomography for Battery Research by Leveraging Artificial Intelligence

X-ray computed tomography (CT) is a non-destructive imaging technique in which contrast originates from the materials' absorption coefficient. The recent development of laboratory nanoscale CT (nano-CT) systems has pushed the spatial resolution for battery material imaging to voxel sizes of 50 nm, a limit previously achievable only with synchrotron facilities. Given the non-destructive nature of CT, in situ and operando studies have emerged as powerful methods to quantify morphological parameters, such as tortuosity factor, porosity, surface area and volume expansion, during battery operation or cycling. Combined with artificial intelligence and machine learning analysis techniques, nano-CT has enabled the development of predictive models to analyse the impact of the electrode microstructure on cell performances or the influence of material heterogeneities on electrochemical responses. In this Review, we discuss the role of X-ray CT and nano-CT experimentation in the battery field, discuss the incorporation of artificial intelligence and machine learning analyses and provide a perspective on how the combination of multiscale CT imaging techniques can expand the development of predictive multiscale battery behavioural models.

diagnostics↗

In situ nanoscale imaging of moiré superlattices in twisted van der Waals heterostructures

Abstract Direct visualization of nanometer-scale properties of moiré superlattices in van der Waals heterostructure devices is a critically needed diagnostic tool for study of the electronic and optical phenomena induced by the periodic variation of atomic structure in these complex systems. Conventional imaging methods are destructive and insensitive to the buried device geometries, preventing practical inspection. Here we report a versatile scanning probe microscopy employing infrared light for imaging moiré superlattices of twisted bilayers graphene encapsulated by hexagonal boron nitride. We map the pattern using the scattering dynamics of phonon polaritons launched in hexagonal boron nitride capping layers via its interaction with the buried moiré superlattices. We explore the origin of the double-line features imaged and show the mechanism of the underlying effective phase change of the phonon polariton reflectance at domain walls. The nano-imaging tool developed provides a non-destructive analytical approach to elucidate the complex physics of moiré engineered heterostructures.

77 NANOSCIENCE AND NANOTECHNOLOGY↗