Search NASA⌕ Search

SEARCH · Search NASA

Results for “noninvasive”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Noninvasive acoustic time-of-flight measurements in heated, hermetically-sealed high explosives using a convolutional neural network

In this work, we present a data-driven technique for measuring the time-of-flight through material sealed within a container. Time-of-flight measurement provides a noninvasive means of quantifying the sound speed profile within a material by transmitting an acoustic burst and then measuring the time required for the burst to arrive at an opposing receiver. In a hermetically-sealed cylindrical container, a portion of the acoustic energy propagates through the material as a bulk wave, while the remainder of the acoustic energy propagates around the container walls as guided waves. As a result, interference from the guided waves obscures the bulk arrival, inhibiting measurement of the sound speed. The technique uses a Convolutional Neural Network (CNN) to identify critical features in the measured waveforms and identify bulk wave arrivals. We demonstrate this time-of-flight measurement technique on high explosive-filled containers as they are heated from room temperature to detonation. This is a particularly challenging application for acoustic time-of-flight measurements as the high explosives have significant sound speed gradients as they undergo heating, and they lead to significant attenuation of the bulk wave, as opposed to the guided waves, which do not suffer significant attenuation. We characterize the performance of the CNN as a function of the high explosive temperature and as a function of the CNN hyperparameters. We then provide physical insight into the error trends.

47 OTHER INSTRUMENTATION↗

Noninvasive interrogation of local flow phenomena in twisted tape swirled flow via positron emission particle tracking ($\mathrm{PEPT}$)

Twisted tape inserts are often used to enhance the performance of heat exchangers. Previous simulations suggest the existence of secondary vortices and modified axial velocity profiles in these swirled flows, with only limited experimental evidence for these predictions. Here in this work, positron emission particle tracking (PEPT) is used to interrogate turbulent twisted tape swirl flow in a pipe. PEPT is a noninvasive, radiotracer based flow measurement technique that does not require optical access, making it suitable for measurements in a number of engineering flow systems. The existence of the modified velocity profile and secondary flows is confirmed using PEPT, and flow is seen to still be developing 20 diameters downstream of the twisted channel entrance. Secondary vortices are further confirmed by the presence of increased vorticity in these regions, and turbulent fluctuations are seen to increase in magnitude near these flow structures. These results are in line with predictions and point to possible regions of reduced heat transfer and hot spots in twisted tape based heat exchangers. Suggestions are made for future experiments to investigate heated flows, utilizing the ability of PEPT to image flows in opaque systems for validating simulation of flows in engineering equipment, such as nuclear heat transport equipment.

42 ENGINEERING↗

Noninvasive liquid level sensing with laser generated ultrasonic waves

This article proposes a noninvasive liquid level sensing technique using laser-generated ultrasound waves for nuclear power plant applications. Liquid level sensors play an important role of managing the coolant system safely and stably in the plant structure. Current sensing techniques are mostly intrusive, performing inside the fluidic structure, which is disadvantageous in terms of the regular maintenance of the plant system. Furthermore, typical intrusive sensors do not perform stably under varying environmental conditions such as temperature and radiation. In this study, sensing units are attached to the outer surface of a liquid vessel to capture guided ultrasound waves in a nonintrusive manner. The signal intensity of the guided wave dissipates when the signal interacts with the internal liquid media. The sensing mechanism is mathematically expressed as an index value to correlate the liquid level with the sensor signal. For the acoustic wave generation, laser-generated ultrasound was adopted instead of using typical contact type transducers. Following the simulation validation of the proposed concept, the performance of the developed sensor was confirmed through experimental results under elevated liquid temperature conditions. Finally, the nonlinear multivariable regression exhibited the best-fit to the datasets measured under the variable liquid level and temperature conditions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Noninvasive THz-TDS measurements of plasma bounded and optically shielded by Hall thruster wall material

We experimentally demonstrate the capability of terahertz time-domain spectroscopy (THz-TDS) to noninvasively measure the electron density and collision frequency of plasma bounded and optically shielded by Hall thruster wall material. This paper augments the standard THz-TDS plasma diagnostic theory to account for plasma boundaries, presents THz optical property measurements of three different wall materials (grades M, M26, and HP boron nitride composite), and provides electron density and collision frequency measurements of an inductively coupled plasma bounded and optically shielded by each wall material. We find that the electron density measurement capability is weakly impacted by the boundaries, whereas the electron collision frequency measurement capability is strongly reduced by the boundaries. Here, the bounded plasma electron density trends deviate substantially from those of the unbounded plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Noninvasive mid-circuit measurement and reset on atomic qubits

Mid-circuit measurement and reset of subsets of qubits are crucial ingredients of quantum error correction and many quantum information applications. Measurement of atomic qubits is accomplished through resonant fluorescence, which typically disturbs neighboring atoms due to photon scattering. We propose and prototype a scheme for measurement and reset that provides both spatial and spectral isolation by using tightly focused laser beams and narrow atomic transitions. The unique advantage of this scheme is that all operations are applied exclusively to the read-out qubit, with little overhead and negligible disturbance to the other qubits of the same species. In this paper, we pave the way for noninvasive and high-fidelity mid-circuit measurement and demonstrate all key building blocks on a single trapped barium ion.

atomic systems↗

Noninvasive Imaging of a Liquid Jet

Liquid jets are found in many applications, from printing to manufacturing to entertainment. Herein this study uses three different noninvasive imaging modalities to compare resulting images of a liquid jet operating at three Reynolds numbers that cover laminar, transitional, and turbulent flow. Selected measurement quantities from each image type are also compared. High-speed backlit (BL) imaging is a simple imaging technique found in many laboratories, and this is compared to two high-speed X-ray imaging techniques, white beam (WB) imaging and focused beam (FB) radiography. BL imaging can provide a wide field of view and is easy to implement, but it only shows the presence or absence of liquid. WB imaging can show detailed contours on the surface of the liquid jet, but the imaging region is much smaller. FB radiography produces a point-source measurement and can provide the quantitative, instantaneous local liquid path length, termed the equivalent path length (EPL). All three techniques provide similar measures of jet thickness, with the FB measurements having less variation. FB measurements can also provide detailed cross sections of the average liquid jet thickness at high spatial resolutions.

42 ENGINEERING↗

Noninvasive measurements of spin transport properties of an antiferromagnetic insulator

Antiferromagnetic insulators (AFIs) are of substantial interest because of their potential in the development of next-generation spintronic devices. One major effort in this emerging field is to harness AFIs for long-range spin information communication and storage. Here, we report a noninvasive method to optically access the intrinsic spin transport properties of an archetypical AFI α-Fe 2 O 3 via nitrogen-vacancy (NV) quantum spin sensors. By NV relaxometry measurements, we successfully detect the frequency-dependent dynamic fluctuations of the spin density of α-Fe 2 O 3 along the Néel order parameter, from which an intrinsic spin diffusion constant of α-Fe 2 O 3 is experimentally measured in the absence of external spin biases. Our results highlight the significant opportunity offered by NV centers in diagnosing the underlying spin transport properties in a broad range of high-frequency magnetic materials such as two-dimensional magnets, spin liquids, and magnetic Weyl semimetals, which are challenging to access by the conventional measurement techniques.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Cardiocirculatory responses to exercise - Physiologic study by noninvasive techniques.

The changes from rest to exercise were determined for certain phases of the cardiac cycle in ten healthy male subjects who underwent submaximal, physiologically paced bicycle ergometry. ECGs, phonocardiograms, and carotid pu lse tracings were recorded. The preejection period and isovolumic contraction time decreased with exercise. Changes in left ventricular ejection time appeared to depend on the severity or the duration of stress. Pulse transmission time did not change significantly. The data obtained in the study and comparison of these results to those obtained by invasive methods indicate that noninvasive techniques, when used in the manner suggested, are appropriate means for detecting a variety of cardiocirculatory changes during exercise.

Pigott, V. M.↗

Noninvasive measurement of central venous pressure

A technique for the noninvasive measurement of CVP in man was developed. The method involves monitoring venous velocity at a point in the periphery with a transcutaneous Doppler ultrasonic velocity meter while the patient performs a forced expiratory maneuver. The idea is the CVP is related to the value of pressure measured at the mouth which just stops the flow in the vein. Two improvements were made over the original procedure. First, the site of venous velocity measurement was shifted from a vein at the antecubital fossa (elbow) to the right external jugular vein in the neck. This allows for sensing more readily events occurring in the central veins. Secondly, and perhaps most significantly, a procedure for obtaining a curve of relative mean venous velocity vs mouth pressure was developed.

Webster, J. G.↗

Postural effects on the noninvasive baselines of ventricular performance

The effects of posture on time-based noninvasive measurements were determined utilizing the sequence supine-sitting-standing in a formal protocol in which observer biases were eliminated by blinding the measurement and calculation phases. Compared to the supine posture, the sitting and standing postures produced significant increases in heart rate, isovolumic contraction time, pre-ejection period and pre-ejection period/left-ventricular ejection time and significant decreases in ejection time and ejection time index. The response patterns are consistent with the hemodynamic correlates cited in the literature which show increased adrenergic activity and decreased venous return in the sitting and standing postures, the effect on venous return being dominant.

Lance, V. Q.↗

Noninvasive aortic bloodflow by Pulsed Doppler Echocardiography (PDE) compared to cardiac output by the direct Fick procedure

Left ventricular stroke volume was estimated from the systolic velocity integral in the ascending aorta by pulsed Doppler Echocardiography (PDE) and the cross sectional area of the aorta estimated by M mode echocardiography on 15 patients with coronary disease undergoing right catheterization for diagnostic purposes. Cardiac output was calculated from stroke volume and heart volume using the PDE method as well as the Fick procedure for comparison. The mean value for the cardiac output via the PDE method (4.42 L/min) was only 6% lower than for the cardiac output obtained from the Fick procedure (4.69 L/min) and the correlation between the two methods was excellent (r=0.967, p less than .01). The good agreement between the two methods demonstrates that the PDE technique offers a reliable noninvasive alternative for estimating cardiac output, requiring no active cooperation by the subject. It was concluded that the Doppler method is superior to the Fick method in that it provides beat by beat information on cardiac performance.

Source record↗

Noninvasive estimation of fluid shifts between body compartments by measurement of bioelectric characteristics

Previous research has established that bioelectrical characteristics of the human body reflect fluid status to some extent. It has been previously assumed that changes in electrical resistance (R) and reactance (X) are associated with changes in total body water (TBW). The purpose of the present pilot investigation was to assess the correspondence between body R and X and changes in estimated TBW and plasma volume during a period of bedrest (simulated weightlessness). R and X were measured pre-, during, and post- a 13 day bedrest status. Although a clear relationship was not elucidated, evidence was found suggesting that R and X reflect plasma volume rather than TBW. Indirect evidence provided by previous studies which investigated other aspects of the electrical/fluid relationship, also suggests the independence of TBW and electrical properties. With further research, a bioelectrical technique for noninvasively tracking fluid changes consequent to space flight may be developed.

Bishop, Phillip A.↗

Evaluation of noninvasive cardiac output methods during exercise

Noninvasive techniques to estimate cardiac output (Qc) will be used during future space flight. This retrospective literature survey compared the Qc techniques of carbon dioxide rebreathing (CO2-R), CO2 single breath (CO2-S), Doppler (DOP), impedance (IM), and inert gas (IG: acetylene or nitrous oxide) to direct (DIR) assessments measured at rest and during exercise.

Moore, Alan D.↗

Noninvasive Optical Probe Of Ferroelectric Films

Thin films of ferroelectric materials probed by near-field, noninvasive mapping of photoresponse from film to obtain high-spatial-resolution information on distribution of polarization domains within film. Photoresponse technique yields data on microscopic structure of electric fields in ferroelectric material, without disturbing structure.

Thakoor, Sarita↗

Microemulsion characterization by the use of a noninvasive backscatter fiber optic probe

This paper demonstrates the utility of a noninvasive backscatter fiber optic probe for dynamic light-scattering characterization of a microemulsion comprising sodium dodecyl sulfate/1-butanol/ brine/heptane. The fiber probe, comprising two optical fibers precisely positioned in a stainless steel body, is a miniaturized and efficient self-beating dynamic light-scattering system. Accuracy of particle size estimation is better than +/- 2 percent.

Ansari, Rafat R.↗

Validation of Spectral Analysis as a Noninvasive Tool to Assess Autonomic Regulation of Cardiovascular Function

A major focus of our program has been to develop a sensitive noninvasive procedure to quantify early weightlessness-induced changes in cardiovascular function or potential dysfunction. Forty studies of healthy young volunteers (10 men and 10 women, each studied twice) were conducted to determine changes in the sympatho-vagal balance of autonomic control of cardiovascular regulation during graded headward and footward blood volume shifts. Changes in sympatho-vagal balance were classified by changes in the mean levels and spectral content of cardiovascular variables and verified by changes in circulating levels of catecholamines and pancreatic polypeptide. Possible shifts in intra/extravascular fluid were assessed from changes in hematocrit and plasma mass density while changes in the stimulus to regulate plasma volume were determined from Plasma Renin Activity (PRA). Autonomic blockade was used to unmask the relative contribution of sympathetic and parasympathetic efferent influences in response to 10 min each of 0, 20 and 40 mmHg Lower Body Negative Pressure (LBNP) and 15 and 30 mmHg Positive Pressure (LBPP). The combination of muscarinic blockade with graded LBNP and LBPP was used to evoke graded increases and decreases in sympathetic activity without parasympathetic contributions. The combination of beta blockade with graded LBNP and LBPP was used to produce graded increases and decreases in parasympathetic activity without beta sympathetic contributions. Finally, a combination of both beta and muscarinic blockades with LBNP and LBPP was used to determine the contribution from other, primarily alpha adrenergic, sources. Mean values, spectral analyses and time frequency analysis of R-R interval (HR), Arterial Pressure (AP), peripheral blood flow (RF), Stroke Volume (SV) and peripheral resistance (TPR) were performed for all phases of the study. Skin blood Flow (SF) was also measured in other studies and similarly analyzed. Spectra were examined for changes in three frequency regions (low 0.006 - 0.005 Hz (LF), mid 0.05 - 0.15 Hz (W), and high 0.15 - 0.45 Hz (EF)). The primary objective of the study was to indicate which changes in the mean values and/or spectra of cardiovascular variables consistently correlated with changes in sympatho-vagal balance in response to headward and footward fluid shifts. A secondaey objective was to quantify the vascular and extravascular fluid shifts evoked by LBNP and LBPP. The principal hypothesis being tested was that headward fluid shifts would evoke an increase in parasympathetic activity and footward fluid shifts would evoke an increase in sympathetic activity both of which would be detected by spectral analysis and verified by circulating hormones. Hematocrit (HCT), plasma mass density and plasma renin activity increased with muscarinic blockade and with LBNP, a response indicative of a plasma shift to extravascular spaces. Beta blockade alone or after muscarinic blockade had no effect on HCT or plasma mass density. With respect to intravascular fluid volume distribution, LBNP and LBPP produced sufficient upper body vascular fluid shifts to evoke appropriate autonomic regulatory responses.

Knapp, Charles F.↗