Search NASA⌕ Search

SEARCH · Search NASA

Results for “nuclear explosion monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Applying Compression-Based Metrics to Seismic Data in Support of Global Nuclear Explosion Monitoring

The analysis of seismic data for evidence of possible nuclear explosion testing is a critical global security mission that relies heavily on human expertise to identify and mark seismic signals embedded in background noise. To assist analysts in making these determinations, we adapted two compression distance metrics for use with seismic data. First, we demonstrated that the Normalized Compression Distance (NCD) metric can be adapted for use with waveform data and can identify the arrival times of seismic signals. Then we tested an approximation for the NCD called Sliding Information Distance (SLID), which can be computed much faster than NCD. We assessed the accuracy of the SLID output by comparing it to both the Akaike Information Criterion (AIC) and the judgments of expert seismic analysts. Our results indicate that SLID effectively identifies arrival times and provides analysts with useful information that can aid their analysis process.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

The history and outlook for seismic monitoring of nuclear explosions in the context of the Comprehensive Nuclear-Test-Ban Treaty

Modern methods of nuclear-explosion monitoring are vastly more capable than they were when underground nuclear testing began in the late 1950s, in part because a cycle of improvements in explosion monitoring in the 1960–80 period led to improvements in monitoring for earthquakes and other phenomena, which then led to a general growth in monitoring assets that in turn has been applied back to explosion monitoring. Practical experiences in nuclear-explosion monitoring, acquired during the era of active testing prior to finalization of the CTBT text in 1996, laid the basis for monitoring in support of this arms-control initiative. This article elaborates on the future of nuclear-test-monitoring technology, which can build upon an additional and remarkable growth of general monitoring assets that began in the 1990s, largely unrelated to the specifics of nuclear-test monitoring. A new cycle of improvements in earthquake monitoring is likely to improve monitoring for explosions. While it is not easy to quantify the degree of monitoring improvement afforded by such new assets, an example from North Korea indicates the improvement can be substantial.

99 GENERAL AND MISCELLANEOUS↗

135 Xe measurements with a two-element CZT-based radioxenon detector for nuclear explosion monitoring

Measurement of elevated concentrations of xenon radioisotopes ( 131m Xe, 133m Xe, 133 Xe and 135 Xe) in the atmosphere has been shown to be a very powerful method for verifying whether or not a detected explosion is nuclear in nature. These isotopes are among the few with enough mobility and with half-lives long enough to make their detection at long distances realistic. Existing radioxenon detection systems used by the Comprehensive Nuclear-Test-Ban Treaty Organization (CTBTO) suffer from problems such as complexity, need for high maintenance and memory effect. To study the response of CdZnTe (CZT) detectors to xenon radioisotopes and investigate whether it is capable of mitigating the afore-mentioned issues with the current radioxenon detection systems, a prototype detector utilizing two coplanar CZT detectors was built and tested at Oregon State University. The detection system measures xenon radioisotopes through beta-gamma coincidence technique by detecting coincidence events be-tween the two detectors. Here in this paper, we introduce the detector design and report our measurement results with radioactive lab sources and 135 Xe produced in the OSU TRIGA reactor. Minimum Detectable Concentration (MDC) for 135 Xe was calculated to be 1.47 ± 0.05 mBq/m 3 .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Impact of environmental backgrounds on atmospheric monitoring of nuclear explosions

Radionuclide monitoring for nuclear explosions includes measuring radioactive aerosol and noble gas concentrations in the atmosphere. The International Monitoring System (IMS) of the Comprehensive Nuclear Test Ban Treaty (CTBT) has made such measurements for decades, revealing much about how atmospheric radioactivity impacts the sensitivity of the network. For example, civilian emissions of radioiodine make a substantial regional impact, but a minor global impact, while civilian radioxenon emissions create major regional and complex global impacts. This example statement is strongly influenced by the minimum signal level anticipated to be interesting. The original design of the IMS anticipated relatively large signal levels, and the accomplished IMS network substantially meets or exceeds the sensitivity needed to detect those signal levels. Much lower signal levels can be motivated, which could require reconsideration of station sensitivity. Using measured and simulated background concentrations, various possible desired signal levels, and an innovative anomaly threshold, maps of sensitivity and a station ranking are developed for current and future stations. These provide a strong motivation for additional experimentation to learn about sources and the potential plusses of new technology.

Eslinger, Paul W.↗

Open Data for Nuclear Explosion Monitoring (NEM) [Slides]

The data sources tend to have the highest quality data and metadata, particularly for more recent data sets. Early data from sources such as IRIS tend to have some metadata issues.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Nuclear Explosion Monitoring in the Changing Arctic

As the Arctic warms and loses its perennial ice cover, it attracts new attention as a locus for resource extraction, commerce, communication, and defense. The region previously had a relatively low priority in global geopolitics due to operational challenges but is quickly attracting interest for economic growth, competition, and potential conflict. Future years and decades will see a transformation of the Arctic’s place in global geopolitics. In this context, monitoring both human and natural activity in the Arctic is increasingly critical.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Nuclear explosion monitoring network design considerations

Design of an efficient monitoring network requires information on the type and size of releases to be detected, the accuracy and reliability of the measuring equipment, and the desired network performance. This work provides a scientific basis for optimizing or minimizing networks of 133 Xe samplers to achieve a desired performance level for different levels of release. The approach of this work varies the density of sampling locations to find optimal location subsets, and to explore the properties of variations of those subsets – how crucial is a specific subset; are substitutions problematic? The choice of possible station locations is arbitrary but constrained to some extent by the location of islands, land masses, difficult topography (mountains, etc.) and the places where infrastructure exists to run and support a sampler. Performance is evaluated using hypothetical releases and atmospheric transport models that cover an entire year.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

A multi-Physics Experiment for Low-Yield Nuclear Explosion Monitoring

A series of multi-physics experiments, referred to as Physics Experiment 1 (PE1) is underway at the United States’ Nevada National Security Site (NNSS). The PE1 series includes detonations of three underground chemical explosions in P-tunnel, with fully coupled (PE1 A), partially decoupled (PE1 D L ), and fully decoupled (PE1 B) emplacements. Canisters with gas tracers are imbedded in the explosives, and the tracers are released when the canister is destroyed by the detonation. A dedicated electromagnetic (EM) experiment (EMX) generates well-characterized EM signals at an underground location near the chemical explosive experiments. A series of atmospheric experiments (METEX, REACT, and METREX) release smoke and radioactive tracers around Aqueduct Mesa to test gas transport in complex topography. Each of the chemical explosive experiments includes a network of sensors to record seismic, acoustic, and electromagnetic waves, measurement of atmospheric conditions, and air sample collection for measurement of tracer concentration. EMX records EM signals underground and on the surface of Aqueduct Mesa. METEX, REACT, and METREX include measurement of atmospheric condition, as well as tracking smoke releases. REACT and METREX add low-level radioactive gas tracers to the atmospheric releases.

58 GEOSCIENCES↗