Search NASA⌕ Search

SEARCH · Search NASA

Results for “nuclide identification”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Optimizing the Performance of Radionuclide Identification Software in the Hunt for Nuclear Security Threats

The Radionuclide Analysis Kit (RNAK), my team’s most recent nuclide identification software, is entering the testing phase. A question arises: will removing rare nuclides from the software’s library improve its overall performance? An affirmative response indicates fundamental errors in the software’s framework, while a negative response confirms the effectiveness of the software’s key machine learning algorithms. After thorough testing, I found that the performance of RNAK cannot be improved with the library choice effect, thus verifying the effectiveness of RNAK’s algorithms—multiple linear regression, Bayesian network using the Viterbi algorithm, and branch and bound search.

97 MATHEMATICS AND COMPUTING↗

Replicative Assessment of Spectroscopic Equipment

The Replicative Assessment of Spectrometric Equipment (RASE) is a software for evaluating the performance of radiation detectors and isotope identification algorithms. It uses a semi-empirical approach to rapidly generate synthetic spectra and inject into detector's software to obtain nuclide identification response. RASE facilitates studies of spectroscopic device performance and a quantitative assessment of its capabilities to correctly distinguish and identify isotopes of interest in realistic scenarios.

Chavez, JosephR.↗

Replicative Assessment of Spectroscopic Equipment v3.0

The Replicative Assessment of Spectrometric Equipment (RASE) is a software for evaluating the performance of radiation detectors and isotope identification algorithms. It uses a semi-empirical approach to rapidly generate synthetic spectra and inject into detector's software to obtain nuclide identification response. RASE facilitates studies of spectroscopic device performance and a quantitative assessment of its capabilities to correctly distinguish and identify isotopes of interest in realistic scenarios

Sangiorgio, Samuele↗

Replicative Assessment of Spectroscopic Equipment v3.1

The Replicative Assessment of Spectrometric Equipment (RASE) is a software for evaluating the performance of radiation detectors and isotope identification algorithms. It uses a semi-empirical approach to rapidly generate synthetic spectra and inject into detector's software to obtain nuclide identification response. RASE facilitates studies of spectroscopic device performance and a quantitative assessment of its capabilities to correctly distinguish and identify isotopes of interest in realistic scenarios

Sangiorgio, Samuele [Lawrence Livermore National L↗

Comparison of MCNP and Experimental Measurements for an HPGe-based Spectroscopy Portal Monitor.

The necessity to monitor international commercial transportation for illicit nuclear materials resulted in the installation of many nuclear radiation detection systems in Portal Monitors. These were mainly gross counters which alarmed at any indication of high radioactivity in the shipment, the vehicle or even the driver. The innocent alarm rate, due to legal shipments of sources and NORM, or medical isotopes in patients, caused interruptions and delays in commerce while the legality of the shipment was verified. To overcome this difficulty, Department of Homeland Security (DHS) supported the writing of the ANSI N42.38 standard (Performance Criteria for Spectroscopy-Based Portal Monitors used for Homeland Security) to define the performance of a Portal Monitor with nuclide identification capabilities, called a Spectroscopy Portal Monitor. This standard defines detection levels and response characteristics for the system for energies from 25 keV to3. MeV. To accomplish the necessary performance, several different HPGe detector configurations were modeled using MCNP for the horizontal field of view (FOV) and vertical linearity of response over the detection zone of 5 meters by 4.5 meters for 661 keV as representative of the expected nuclides of interest. The configuration with the best result was built and tested. The results for the FOV as a function of energy and the linearity show good agreement with the model and performance exceeding the requirements of N42.38.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of a Low Activity Beta-Sensitive SR{sup 90} Water Monitor for Fukushima

There are large volumes of contaminated water from the stabilization efforts at the damaged Fukushima Nuclear Power Plants. This water is being processed to remove radioactivity for eventual release to the environment. An on-line continuously operating system to confirm that the clean-up system is working properly, and to provide prompt feedback of the results is required by the system operator. While gamma emitting nuclides allow for the straight forward approach of gamma spectroscopy to identify and quantify radioactivity in water, pure beta emitting nuclides such as Sr{sup 90} pose a challenging problem. The relatively short range of beta radiation in water requires optimization of the measurement geometry in terms of the source-detector distance and source-detector interface while retaining a background sensitivity low enough to meet the Minimum Detectable Concentration (MDC) of 10 Bq/kg in 180 minutes. This issue is complicated by the continuum nature of the beta spectrum which does not allow for simple nuclide identification. The use of the Monte-Carlo code MCNP to estimate system performance before prototyping vastly increases the success of the end product. Various parameters such as detector size and thickness, water chamber size, water chamber construction materials were evaluated to help choose the optimum geometry. The final design was a system consisting of two large-area (16 x 35 cm) and thin (0.15 mm) plastic scintillators placed very close to a sealed a water chamber. The size of the chamber was optimized to obtain the maximum efficiency for the nuclide being measured (Sr/Y{sup 90}) but to minimize the efficiency for possible interferences (Ru/Rh{sup 106}, Cs{sup 137}). A thin carbon fiber window was selected with adequate material and thickness to contain the water under pressure, but also thin enough (0.5 mm) to allow enough beta radiation to pass through to the active detector volume. The entire measurement geometry is then housed in a thick lead shield to reduce contributions from external sources to an acceptable level. Data acquisition is accomplished through customized application-specific software that allows for long counting times to attain a low MDC, but also simultaneously provides alarms on short averaging times to achieve a fast response to sudden changes in activity concentration. Multiple monitors are then linked to supervisory software where real time data and alarms are available for analysis in remote locations. The system also allows for remote operation of the unit; check sources, background checks, systems settings and more may be accessed remotely. Testing of the production devices has shown that we can achieve the 10 Bk/kg MDC requirement for Sr{sup 90} in equilibrium with Y{sup 90} with a count time of approximately 20 minutes. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Systematic study of variation in radiation data in cluttered environments

There are many challenges to overcome during nuclear nonproliferation measurements, including a wide variety of clutter sources that may be introduced into a scene during acquisition. The ability to understand how the dissimilarity of various objects, or clutter, obscures a detector’s field of view and affects the measured response of the detector improves the input to detection alarm and nuclide identification algorithms. Additionally, having the capability to input clutter variation into radiation transport models would allow for more real-world scenarios to be modeled and understood. Efforts at Oak Ridge National Laboratory have been exploring the ability to determine specific natural background radiation contributions from surroundings, such as buildings, soil, asphalt, and concrete, and use those source terms in large-scale (100 + m) models. The capability to quantify different clutter terms, ranging from humans to large vehicles, allows researchers to inject realistic noise into these models. The work reported herein seeks to explore the effects that clutter introduces to quantify the expected signal variation inherent to both controlled and uncontrolled scenarios, specifically how the introduction of clutter into a scene introduces a variation in signals due to the attenuation of naturally occurring radioactive material distributed within the scene or by introducing non-threatening radioactive materials into the scene. Controlled measurements aim to quantify how different types of clutter of varying size and composition affects the response of a radiation detector. Using results from various controlled tests, the systematic effects of clutter and its effect on radiation readings is analyzed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Canberra Falcon 5000 Job-Aid

The Falcon 5000 is a portable, mechanically-cooled, coaxial HPGe gamma-ray detector. Its high resolution and efficiency over a wide energy range make it wellsuited for nuclide identification, plutonium isotopic composition analysis, and prompt gamma analysis.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ORTEC Detective DX/EX-100

The Detective is a portable, mechanically-cooled, coaxial HPGe gamma-ray detector. Its reasonable high resolution and efficiency over a wide energy range make it well-suited for nuclide identification and isotopic composition analysis.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radioactivity observed in scintillation counters during the HEAO-1 mission

Results are reported from an analysis of radioactivity induced in the NaI medium-energy detector of the hard X-ray and low-energy gamma-ray experiment during the HEAO-1 satellite mission (1977-1978). Consideration is given to the instrument characteristics, the origin and variability of background, and the separation of cosmic-ray activity from the internal activity due to South Atlantic Anomaly trapped protons. Energy spectra and tables listing the nuclide identifications are provided.

Gruber, D. E.↗

Self-Correction of Lanthanum-Cerium Halide Gamma Spectra (pre-print)

Lanthanum-cerium halide detectors generally exhibit superior energy resolutions for gamma radiation detection compared with conventional sodium iodide detectors. However, they are also subject to self-activities due to lanthanum-138 decay and contamination due to beta decay in the low-energy region and alpha decay in the high-energy region. The detector’s self-activity and crystal contamination jointly contribute a significant amount of uncertainties to the gamma spectral measurement and affect the precision of the nuclide identification process. This paper demonstrates a self-correction procedure for self-activity and contamination reduction from spectra collected by lanthanum-cerium halide detectors. It can be implemented as an automatic self-correction module for the future gamma radiation detector made of lanthanum-cerium halide crystals.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The beam diagnostic instruments in Beijing radioactive ion-beam facilities isotope separator on-line

The beam diagnostic instruments for Beijing Radioactive Ion-beam Facilities Isotope Separator On-Line are introduced [B. Q. Cui, Z. H. Peng, Y. J. Ma, R. G. Ma, B. Tang, T. Zhang, and W. S. Jiang, Nucl. Instrum. Methods 266, 4113 (2008); T. J. Zhang, X. L. Guan, and B. Q. Cui, in Proceedings of APAC 2004, Gyeongju, Korea, 2004, http://www.jacow.org , p. 267]. For low intensity ion beam [30–300 keV/1 pA–10 μA], the beam profile monitor, the emittance measurement unit, and the analyzing slit will be installed. For the primary proton beam [100 MeV/200 μA], the beam profile scanner will be installed. For identification of the nuclide, a beam identification unit will be installed. The details of prototype of the beam diagnostic units and some experiment results will be described in this article.

43 PARTICLE ACCELERATORS↗

Direct identification of Ac and No molecules with an atom-at-a-time technique

The periodic table provides an intuitive framework for understanding chemical properties. However, its traditional patterns may break down for the heaviest elements occupying the bottom of the chart. Here, the large nuclei of actinides (Z > 88) and superheavy elements (Z ≥ 104) give rise to relativistic effects that are expected to substantially alter their chemical behaviours, potentially indicating that we have reached the end of a predictive periodic table. Relativistic effects have already been cited for the unusual chemistry of the actinides compared with those of their lanthanide counterparts. Unfortunately, it is difficult to understand the full impact of relativistic effects, as research on the later actinides and superheavy elements is scarce. Beyond fermium (Z = 100), elements need to be produced and studied one atom at a time, using accelerated ion beams and state-of-the-art experimental approaches. So far, no experiments have been capable of directly identifying produced molecular species. Here ions of actinium (Ac, Z = 89) and nobelium (No, Z = 102) were synthesized through nuclear reactions at the 88-Inch Cyclotron facility at Lawrence Berkeley National Laboratory and then exposed to trace amounts of H 2 O and N 2 . The produced molecular species were directly identified by measuring their mass-to-charge ratios using FIONA (For the Identification Of Nuclide A). These results mark the first, to our knowledge, direct identification of heavy-element molecular species using an atom-at-a-time technique and highlight the importance of such identifications in future superheavy-element chemistry experiments to deepen understanding of their chemical properties.

Pore, Jennifer L. [Lawrence Berkeley National Labo↗

The effect of energy resolution on the extraction of information content from gamma-ray spectra

Rapid unambiguous identification of illicit radioactive materials is a matter of international concern that has yet to be fully attained. This is particularly true for shielded fissile materials in the presence of background radiation and routinely encountered benign radionuclides. Here, we present a systematic treatment of the effect of detector resolution on the identification of nuclides in simple and complex shielded γ-ray spectra. Case studies of some problematic spectra with 1000 counts suggest that, at moderate count rates, near-unambiguous identification (<1% probability of misidentification) of potential fissile sources requires a detector with an energy resolution of at least 1–2% at 662 keV. While somewhat limited in scope, the study establishes a quantitative basis for the comparative evaluation of detectors of comparable efficiency.

42 ENGINEERING↗

Identification of the New Isotope 244 Md

In an experiment performed at Lawrence Berkeley National Laboratory’s 88-inch cyclotron, the isotope Md 244 was produced in the Bi 209 ( Ar 40 , 5 n ) reaction. Decay properties of Md 244 were measured at the focal plane of the Berkeley Gas-filled Separator, and the mass number assignment of A = 244 was confirmed with the apparatus for the identification of nuclide A . The isotope Md 244 is reported to have one, possibly two, α -decaying states with α energies of 8.66(2) and 8.31(2) MeV and half-lives of 0.4 – 0.1 + 0.4 and ~ 6 s , respectively. Furtermore, first evidence of the α decay of Bk 236 was observed and is reported.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

SCALE/Sampler Sensitivity Indices

The Sampler sequence of the SCALE code system for random sampling–based uncertainty analyses has recently been extended by including a sensitivity analysis. In uncertainty analyses with respect to uncertainties in the nuclear data, the determination of two multiple correlation coefficients—R2 and SPC2—allows for the identification of nuclide reactions that are significantly contributing to the investigated output uncertainty. Individual nuclide reactions are ranked by importance, allowing suggestions for additional measurements and evaluations to significantly reduce the observed output uncertainty. A brief description of the theory is provided herein, followed by application of this analysis to a sodium-cooled fast reactor pin cell.

Bostelmann, Rike↗

Nuclear Data Sheets for A=266,270,274,278,282,286,290,294,298☆

Spectroscopic information such as production, identification, half-lives, decay modes and possible excited states for experimentally known nuclides of mass numbers 266, 270, 274, 278, 282, 286, 290, 294, and 298 are presented together with the recommended values, superseding information and data in the previous ENSDF and NDS evaluation by 2005Gu33. No nuclides have yet been identified for A=302. In the last 14 years, large amounts of new and definitive data on the superheavy nuclides (SHN) have become available, thus changing almost entirely the landscape of nuclear data in this mass region, as also indicated by a number of recent review articles: 2017Og01, 2016Ho09, 2016Ho06 (for fission barriers), 2015Og05, 2015Og07, 2015Mo25, 2015OgZX, 2013Th02, and 2011Og07. See 2016Ka49 for IUPAC technical discussions for the discovery of Z=117 (Ts), Z=115 (Mc), Z=113 (Nh), 2001Ka70 and 2003Ka71 for Z=110-112, 2011Ba54 for Z≥113, 2009Ba62 for Z=112, and 2016Ka50 for Z=118 (Og). A special issue of Nuclear Physics A444 (2015) is devoted to research on superheavy elements (SHE) with 27 articles. In particular, see article by 2015Ko20 on mass spectrometric searches for superheavy elements in terrestrial matter. See also Proceedings of Nobel Symposium NS160 ‘Chemistry and Physics of Heavy and Superheavy Elements’ published in Eur. Phys. Jour. Web of Conferences 131 (2016), in particular 2016UtZZ, 2016DmZZ and 2016HoZY. See also 2016DuZX for future prospects of discovery of elements beyond Z=118 A=266: {sup 266}Db, {sup 266}Sg, {sup 266}Bh, {sup 266}Hs and {sup 266}Mt are the experimentally identified nuclides with A=266. Identification of {sup 266}Lr from α decay of {sup 270}Db has been proposed by 2014Kh04 from experiments at GSI, but complete details and analyses of all the four decay chains reported in this experiment have not yet been published, and discussion in 2015Og05 review article considering their work from Dubna (2013Og04, 2011Og04) and from GSI (2014Kh04) still concluded that {sup 270}Db decayed dominantly by SF mode, in contrast with dominant α decay mode proposed by 2014Kh04. Experiments carried out at FLNR-JINR-Dubna in collaboration with LLNL and ORNL, GSI-SHIP facility, RIKEN, and LBNL facilities: {sup 266}Db from the α-decay of {sup 282}Nh in two correlated decay chains at Dubna; {sup 266}Sg as α-daughter of {sup 270}Hs in 12 correlated decay chains at Dubna and GSI; {sup 266}Bh in α decay of {sup 278}Nh in three correlated decay chains observed at RIKEN, and also directly with one event in {sup 249}Bk({sup 22}Ne,5n) at LBNL, and with four events in {sup 243}Am({sup 26}Mg,3n) at HIRFL-Lanzhou; {sup 266}Hs as α-daughter of {sup 270}Ds at GSI in two different experiments, six correlated decays in the first, and 25 decay chains in the second experiment, the analysis of which has not been fully reported as yet; and {sup 266}Mt directly in {sup 209}Bi({sup 58}Fe,n) reaction at GSI in two different experiments, observing three events in the first experiment and 12 events in the second, also produced in {sup 208}Pb({sup 59}Co,n) reaction at LBNL, observing five correlated decay chains. See also 2000Ho27 for discussion on {sup 266}Sg and {sup 266}Mt. A=270: {sup 270}Db, {sup 270}Bh, {sup 270}Hs, {sup 270}Mt and {sup 270}Ds are the experimentally identified nuclides with A=270 are presented. Experiments carried out at FLNR-JINR-Dubna in collaboration with LLNL and ORNL, GSI-SHIP facility, and RIKEN: {sup 270}Db from the decay of {sup 294}Ts in six correlated decay chains at Dubna and GSI; {sup 270}Bh as α great-granddaughter of {sup 282}Nh in two correlated decay chains observed at Dubna; {sup 270}Hs directly in {sup 248}Cm({sup 26}Mg,4n) reaction at GSI, and in {sup 226}Ra({sup 48}Ca,4n) reaction at Dubna; {sup 270}Mt as granddaughter of {sup 278}Ts in three correlated decay chains at RIKEN; and {sup 270}Ds directly in {sup 207}Pb({sup 64}Ni,n) at GSI in 33 correlated decay chains. A=274: {sup 274}Bh, {sup 274}Mt and {sup 274}Rg are the experimentally identified nuclides with A=274. Search for {sup 274}Ds in {sup 238}U({sup 40}Ar, 4n),E=5.7 MeV/nucleon reaction and subsequent α decays at GSI (1990Sc11) proved negative. Experiments carried out at FLNR-JINR-Dubna in collaboration with LLNL and ORNL, GSI-SHIP facility, and RIKEN: {sup 274}Bh from the decay of {sup 294}Ts in six correlated decay chains at Dubna and GSI, {sup 274}Mt produced as α daughter of {sup 282}Nh in two correlated decay chains observed at Dubna, and {sup 274}Rg as α daughter of {sup 278}Nh produced in three correlated decay chains at RIKEN. A=278: {sup 278}Mt, {sup 278}Rg and {sup 278}Nh are the experimentally identified nuclides with A=278. A very tentative evidence is provided for {sup 278}Bh and {sup 278}Hs from a chain originally observed and assigned to {sup 289}Fl by 1999Og10, but later reassigned by 2004Og10 to {sup 290}Fl, and further discussed in detail by 2016Ho09, where, based on systematics of α decays and SF half-lives, {sup 290}Fl is proposed to decay via ε mode to {sup 290}Nh, which then decays by an α chain, ending in {sup 278}Bh that decays by SF mode. Experiments carried out at FLNR-JINR-Dubna in collaboration with LLNL and ORNL labs in the USA, GSI-SHIP facility, and RIKEN: {sup 278}Mt from the decay of {sup 294}Ts in six correlated decay chains at Dubna and GSI, {sup 278}Rg produced as α daughter of {sup 282}Nh in two correlated decay chains observed at Dubna, and {sup 278}Nh produced directly in three correlated decay chains at RIKEN. A=282: {sup 282}Rg, {sup 282}Cn and {sup 282}Nh are the experimentally identified nuclides with A=282. A very tentative evidence is provided for {sup 282}Mt and {sup 282}Ds from a chain originally observed and assigned to {sup 289}Fl by 1999Og10, but later reassigned by 2004Og10 to {sup 290}Fl, and further discussed in detail by 2016Ho09, where, based on systematics of α decays and SF half-lives, {sup 290}Fl is proposed to decay via ε mode to {sup 290}Nh, which then decays by an α chain, ending in {sup 278}Bh that decays by SF mode. Experiments carried out at FLNR-Dubna, in collaboration with LLNL and ORNL labs in the USA, and at GSI-SHIP facility confirm the identification of these isotopes, {sup 282}Rg in α decay chain of {sup 294}Ts in six correlated decay chains at Dubna and GSI, {sup 282}Cn produced in four ways at Dubna: independently in one correlated decay chain, as α daughter of {sup 286}Lv in 11 correlated decay chains, as α grand-daughter of {sup 290}Lv in 12 correlated decay chains, as α great-grand daughter of {sup 294}Og in four correlated decay chains, and {sup 282}Nh produced at Dubna directly in two correlated decay chains. A=286: {sup 286}Nh and {sup 286}Fl are the only experimentally identified nuclides with A=286. A very tentative evidence is provided for {sup 286}Rg and {sup 286}Cn from a chain originally observed and assigned to {sup 289}Fl by 1999Og10, but later reassigned by 2004Og10 to {sup 290}Fl, and further discussed in detail by 2016Ho09, where, based on systematics of α decays and SF half-lives, {sup 290}Fl is proposed to decay via ε mode to {sup 290}Nh, which then decays by an α chain, ending in {sup 278}Bh that decays by SF mode. 2017Ka66 in experiments at RIKEN using GARIS separator interpret one correlated decay chain in three different ways, one involving possible production of {sup 294}Lv in {sup 248}Cm({sup 48}Ca,2n),E=261.6 MeV, and α decay to {sup 290}Fl which further decays to {sup 286}Cn. Experiments carried out at FLNR-Dubna, in collaboration with LLNL and ORNL labs in the USA, and at GSI-SHIP facility confirm the identification of these isotopes, {sup 286}Nh as α grand-daughter of {sup 294}Ts in six correlated decay chains, and {sup 286}Fl produced in three ways: independently in 11 correlated decay chains, as α daughter of {sup 290}Lv in 12 correlated decay chains, and as α grand-daughter of {sup 294}Og in four correlated decay chains. A=290: {sup 290}Mc and {sup 290}Lv are the only experimentally identified nuclides with A=290. A tentative evidence is provided for {sup 290}Nh and {sup 290}Fl from a chain originally observed and assigned to {sup 289}Fl by 1999Og10, but later reassigned by 2004Og10 to {sup 290}Fl, and further discussed in detail by 2016Ho09, where, based on systematics of α decays and SF half-lives, {sup 290}Fl is proposed to decay via ε mode to {sup 290}Nh, which then decays by an α chain, ending in {sup 278}Bh that decays by SF mode. 2017Ka66 in experiments at RIKEN using GARIS separator interpret one correlated decay chain in three different ways, one involving possible production of {sup 294}Lv in {sup 248}Cm({sup 48}Ca,2n),E=261.6 MeV, and α decay to {sup 290}Fl. Experiments carried out at FLNR-Dubna, in collaboration with LLNL and ORNL labs in the USA, and at GSI-SHIP facility confirm the identification of these isotopes, {sup 290}Mc as α daughter of {sup 294}Ts in six correlated decay chains, and {sup 290}Lv produced in two ways, independently in 14 correlated decay chains, and as α daughter of {sup 294}Og in four correlated decay chains. A=294: {sup 294}Ts and {sup 294}Og are the only experimentally identified nuclides with A=294. Experiments carried out at FLNR-Dubna, in collaboration with LLNL and ORNL labs in the USA, and at GSI-SHIP facility confirm the identification of these isotopes, with a total of six EVR-α-SF correlated decay chains observed for {sup 294}Ts and four for {sup 294}Og. Tentative identification of {sup 294}Lv is provided by 2017Ka66 from the observation one correlated event using GARIS-RIKEN facility, where this event is interpreted in three possible ways, two interpretations lead to production of {sup 293}Lv and successive odd-A nuclides of {sup 289}Fl, {sup 285}Cn and {sup 281}Ds, whereas the third prediction starts with the production of {sup 294}Lv and successive {sup 290}Fl and {sup 286}Cn nuclides. Search for {sup 294}Rg in natural gold materials (2011De03), and for {sup 294}Ds, {sup 294}Fl and {sup 294}Mc in natural Pt, Pb and Bi samples (2011De21) using accelerator mass spectroscopy (AMS) proved negative, with extremely low upper limits established. Also 1980St05 did not see any evidence for {sup 294}Ds in natural Pt sample using AMS. A=298: Search for {sup 298}120 through fusion-evaporation reaction at Dubna, and for {sup 298}Fl and {sup 298}Mc in natural Pt, Pb and Bi samples using accelerator mass spectroscopy (AMS) proved negative. Tentative assignment of three α-α-α decay chains by 2016Ho09 to {sup 299}120 in {sup 248}Cm({sup 54}Cr,3n){sup 299}120 at GSI was refuted by 2017He11, assigning these correlations to random events, instead. A=302: Fluorescent x rays from Z=120 element were observed by 2012Fr03 from compound nucleus {sup 302}120 produced in {sup 238}U({sup 64}Ni,X),E=6.6 MeV/nucleon at GANIL, and x-ray yields were measured, together with minimum average time deduced from x-ray multiplicity. The compound nucleus could decay by 3n- or 4n-channels to produce {sup 299}120 or {sup 298}120. 2012He05 and 2016Ho09 also produced {sup 302}120 compound nucleus in {sup 248}Cm({sup 54}Cr, xn){sup 302}120{sup *},E=6.035 MeV/nucleon; and {sup 238}U({sup 64}Ni,xn){sup 302}120{sup *},E=5.53 MeV/nucleon reactions using UNILAC at GSI. Three α-α-α correlated decays from {sup 248}Cm({sup 54}Cr,xn){sup 302}120{sup *} reaction were tentatively assigned by 2016Ho09 to {sup 299}120 decay, however, a detailed analysis by 2017He11 refuted this claim, ascribing these events to random sequences. There are no data tables for A=302.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗