Search NASA⌕ Search

SEARCH · Search NASA

Results for “number of injections”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Jupiter Icy Moons Orbiter interplanetary injection period analysis

This paper investigates the sensitivity of the planned Jupiter Icy Moons Orbiter mission to variations in interplanetary injection date, magnitude, and direction, starting in a low-Earth assembly orbit. These results are used to determine the frequency and number of injection opportunities from a processing assembly obit. It is shown that the use of a low-thrust propulsion system with a nuclear-electric power source would allow the interplanetary trajectory performance to be relatively insensitive to variations in injection conditions. This result yields many injection opportunities due to the long injection period and consecutive orbits with favorable geometry.

trajectory↗

Surface Deformation and Seismicity Linked to Fluid Injection in the Raton Basin

Abstract It is suggested that in addition to seismicity deep fluid injection may cause surface uplift and subsidence in oil and gas‐producing regions. This study uses the Raton Basin as an example to investigate the hydromechanical processes of surface uplift and subsidence during wastewater injection. The Raton Basin, in southern central Colorado and northern central New Mexico, has experienced wastewater injection related to coalbed methane and gas production starting in 1994. In this study, we estimate the extent and magnitude of total vertical deformation in the Raton Basin from 1994 to 2020 and incremental deformation between the years 2017 to 2020. Results indicate a modeled uplift as much as 15 cm occurring between 1994 and 2020. Between 2017 and 2020, up to 3 cm of uplift occurred, largely near the northwestern injection wells. Most modeled uplift between 1994 and 2020 occurred near the southern wells, where the greatest cumulative volume of wastewater was injected. However, modeled subsidence occurred around the southern and eastern wells between 2017 and 2020, after the rate of injection decreased. Modeling indicates that while the magnitude of modeled uplift corresponds to cumulative injection volume and maximum rate in the long‐term, short‐term incremental deformation (uplift or subsidence) is controlled by changes in the rate of injection. The number of yearly earthquake events follows periods of rapid modeled uplifting throughout the Basin, suggesting that measurable surface deformation may be caused by the same injection‐induced pore pressure perturbations that initiate seismicity.

Geology↗

Heat transfer and turbulence measurements of a film-cooled flow over a convexly curved surface

Heat transfer and hydrodynamic boundary layer measurements were made in a turbulent boundary layer on a convex surface with 13 rows of injection. Both full- and partial-coverage cases were tested for three blowing ratios: 0.2, 0.4, and 0.6. Heat transfer results are discussed in terms of Stanton number with injection air temperature equal to wall temperature. In the blown region, for both m (blowing ratio) = 0.2 and 0.4, the local response of the boundary layer is dominated by curvature, and m = 0.4 shows higher cooling effects than m = 0.2 or 0.6, as expected, based on flat-plate results. Hydrodynamic measurements with a triple-hot-wire suggest the existence of two streamwise lanes. Lanes containing injection holes are highly affected by injection and show a definite streamwise evolution. Lanes which do not contain holes are not affected much by injection and show little change in the streamwise direction.

Furuhama, K.↗

Leveraging operational information from wastewater injection wells to evaluate CO 2 injection performance for carbon storage applications in the Appalachian Basin

Abstract Geologic parameters, geophysical logging, injection testing, and operational metrics from wastewater injection wells were integrated to develop a preliminary design of a carbon storage facility in the Appalachian Basin. A scattered group of 10–20 commercial wastewater injection wells dispose off produced water from oil and gas wells in the region, utilizing a sequence of stacked deep saline formations for injection zones. These wastewater injection wells provide practical benchmarks for understanding the feasibility of carbon dioxide (CO 2 ) storage. Geologic models were developed based on characterization data from the wastewater injection wells. Reservoir simulations were calibrated according to injection testing and operational data from the wastewater injection wells. Long‐term operational data on injection flow rates and pressures measured in the wastewater injection wells were especially useful to evaluate the performance of carbon storage applications. The simulations were used to estimate injection pressures, radius of CO 2 saturation, and pressure response for industrial scale CO 2 storage applications. Results were also used to provide a design basis in terms of number of injection wells, well spacing, area of review, injection system components, monitoring plan, and CO 2 pipeline distribution system. The analysis demonstrates that there is sufficient injectivity in the deep saline formations in the west‐central Appalachian Basin to store commercial volumes of anthropogenic CO 2 . The geologic system appears suitable for supporting CO 2 injection rates of 0.5–1.0 million metric tons per year at injection pressures below formation fracture pressure in a single well. The long‐term operational data of wastewater injection wells within the study area suggested a lower permeability‐thickness values than indicated by initial reservoir tests. A workflow for developing realistic permeability values for input into reservoir simulations is presented. © 2020 Society of Chemical Industry and John Wiley & Sons, Ltd.

Valluri, Manoj↗

Turbine vane leading edge gas film cooling with spanwise angled coolant holes

An experimental film cooling study was conducted on a 3x size model turbine vane. Injection at the leading edge was from a single row of holes angled in a spanwise direction for two configurations of holes at 18 or 35 deg to the surface. The reduction in the local Stanton number for injection at a coolant-to-mainstream density ratio of 2.18 was calculated from heat flux measurements downstream of injection. Results indicate that optimum cooling occurs near a coolant-to-mainstream velocity ratio of 0.5. Shallow injection angles appear to be most beneficial when injecting into a highly accelerated mainstream.

Hanus, G. J.↗

CFD-Guided Evaluation of Spark-Assisted Gasoline Compression Ignition for Cold Idle Operation

A closed-cycle, three-dimensional (3D) computational fluid dynamics (CFD) analysis campaign was conducted to evaluate the performance of using spark plugs to assist gasoline compression ignition (GCI) combustion during cold idle operations. A conventional spark plug using single-sided J-strap design was put at a location on the cylinder head to facilitate spray-guided spark assistance. Ignition was modeled with an L-type energy distribution to depict the breakdown and the arc-to-glow phases during the energy discharge process. Several key design parameters were investigated, including injector clocking, number of nozzle holes, spray inclusion angle, number of fuel injections, fuel split ratio, and fuel injection timings. The study emphasized the region around the spark gap, focusing on flame kernel formation and development and local equivalence ratio distribution. Flame kernel development and the ignition process were found to correlate strongly with the fuel stratification and the flow velocity near the spark gap. The analysis results showed that the flame kernel development followed the direction of the local flow field. In addition, the local fuel stratification notably influenced early-stage flame kernel development due to varying injection spray patterns and the fuel injection strategies. Among these design parameters, the number of nozzle holes and fuel injection timing had the most significant effects on the engine combustion performance.

42 ENGINEERING↗

Leakage From Coexisting Geologic Forcing and Injection‐Induced Pressurization: A Semi‐Analytical Solution for Multilayered Aquifers With Multiple Wells

Abstract Abnormal fluid pressures (above or below hydrostatic pressure) can develop and persist in sedimentary basins. The common occurrence of abnormal pressures may cause challenges for project permitting of geological carbon sequestration (GCS), particularly in reservoirs with pre‐injection overpressure. The leaky wells that may exist in some sedimentary basins can provide flow paths between deep brine aquifers and shallower freshwater aquifers. Pre‐injection relative overpressures can cause brine leakage through leaky wells even before any injection occurs. The tendency for flow through leaky wells is coupled with the process of pressure dissipation that occurs through aquitards. Specifically, with non‐zero permeability, aquitards can dissipate pressure over large areal extents and thereby reduce leakage rates through leaky wells. This study presents development of a semi‐analytical solution for hydraulic head and brine leakage in multilayered aquifer–aquitard systems with geologic pressure forcing. The geologic forcing that causes abnormal pressures in the multilayered system can coexist with any number of injection, extraction, and leaky wells that also affect fluid pressure. The semi‐analytical model is applied to explore how leakage through leaky wells varies as functions of pressurization rate, along with aquitard and leaky well properties in an overpressured multilayered system. The results show that although injection‐induced pressures can dissipate rapidly through suitably permeable aquitards, coexisting geologic forcing may create sustained rates of brine leakage into freshwater aquifers through leaky wells. In GCS, a very low‐permeability aquitard with high capillary entry pressure to free‐phase CO 2 is desired to serve as the caprock to prevent leakage of CO 2 from the storage reservoir. Nevertheless, the results from this study show that the brine leakage impact to shallow freshwater aquifers through leaky wells might substantially decrease with increasing aquitard permeability values, as long as small aquitard permeability and high capillary entry pressure serve to prevent CO 2 leakage.

Cihan, A.↗

Correlation of Fos expression and circling asymmetry during gerbil vestibular compensation

Vestibular compensation is a central nervous system process resulting in recovery of functional movement and control following a unilateral vestibular lesion. Small pressure injections of phosphorothioate 20mer oligonucleotides were used to probe the role of the Fos transcription protein during vestibular compensation in the gerbil brainstem. During isoflurane gas anesthesia, antisense probes against the c-fos mRNA sequence were injected into the medial vestibular and prepositus nuclei unilaterally prior to a unilateral surgical labyrinthectomy. Anionic dyes, which did not interact with the oligonucleotides, were used to mark the injection site and help determine the extent of diffusion. The antiFos oligonucleotide injections reduced Fos expression at the injection site in neurons which normally express Fos after the lesion, and also affected circling behavior induced by hemilabyrinthectomy. With both ipsilateral and contralateral medial vestibular and prepositus nuclei injections, less ipsilateral and more contralateral circling was noted in animals injected with antiFos injections as compared to non-injected controls. The degree of change in these behaviors was dependent upon the side of the injection. Histologically, antiFos injections reduced the number of Fos immunolabeled neurons around the injection site, and increased Fos expression contralaterally. The correlation of the number of neurons with Fos expression to turning behavior was stronger for contralateral versus ipsilateral turns, and for neurons in the caudal and ipsilateral sub-regions of the medial vestibular and prepositus nuclei. The results are discussed in terms of neuronal firing activity versus translational activity based on the asymmetrical expression of the Fos inducible transcription factor in the medial vestibular and prepositus nuclei. Although ubiquitous in the brain, transcription factors like Fos can serve localized and specific roles in sensory-specific adaptive stimuli. Antisense injections can be an effective procedure for localized intervention into complex physiological functions, e.g. vestibular compensation. Copyright 1999 Elsevier Science B.V.

NASA Discipline Neuroscience↗

Investigation of theoretical scaling laws using large eddy simulations for airborne spreading of viral contagion from sneezing and coughing

Using a set of large eddy point-particle simulations, we explore the fluid dynamics of an ejected puff resulting from a cough/sneeze. The ejection contains over 61,000 potentially virus-laden droplets at an injection Reynolds number of about 46,000, comparable to an actual cough/ sneeze. We observe that global puff properties, such as centroid, puff volume, momentum, and buoyancy vary little across realizations. Other properties, such as maximum extent, shape, and edge velocity of the puff, may exhibit substantial variation. In many realizations, a portion of the puff splits off and advances along a random direction, while keeping airborne droplet nuclei afloat. This peeled-off portion provides a mechanism for virus-laden droplets to travel over large distances in a short amount of time. We also observe that the vast majority of droplets remain suspended within the puff after all liquid has evaporated. The main objectives of the study are to (i) evaluate assumptions of Balachandar’s et al. theory [Int. J. Multiphase Flow 132, 103439 (2020)], which include buoyancy effects, shape of the puff, and droplet evaporation rate, (ii) obtain values of closure parameters, which include location and time of the virtual origin, and puff entrainment and drag coefficients, and (iii) evaluate the accuracy of the theory in predicting the shape, size, and location of the puff, as well as droplet number density long after ejection. The theory adequately predicts global puff properties including size, velocity, and distance traveled, the largest size of droplets that exit the puff due to settling, and the droplet size distribution within the puff long after ejection.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

EV Hosting Capacity Analysis on Distribution Grids

The increasing trend in electric vehicle (EV) adoption can cause challenges to traditional electric grid operations if utilities are not equipped with tools and methods to effectively manage these fleets. Growing EV charging loads will alter the magnitude and duration of conventional peaks in demand profiles and even significantly shift them, potentially causing operational violations in the distribution grid. This paper presents the development and results of an EV hosting capacity tool to quantify the impacts of injecting large numbers of EV charging loads and to determine the available capacity of existing distribution feeders to continue providing reliable and affordable grid operations. Tools like the hosting capacity analysis would enable utilities to better prepare for grid operations in the near future while exploring the impact and effectiveness of strategies to manage these loads, such as peak pricing and smart charging. This paper evaluates the hosting capacity of some real-world feeders to accommodate EV charging loads, including extreme fast-charging options.

distribution grid↗

FECM/NETL Offshore CO2 Saline Storage Cost Model

The FECM/NETL Offshore CO2 Saline Storage Cost Model (CO2_S_COM_Offshore) estimates costs for a CO2 storage project in an offshore saline formation or reservoir. It is applicable for storage projects located on the Outer Continental Shelf of the Gulf of America. The purpose is to model the costs associated with a project, using simplified geo-engineering equations to calculate reservoir values needed to determine costs (such as CO2 plume area and number of injection wells). To use the model, change any of the inputs, which are always in orange cells, to the values you desire. Although there are numerous values that can be changed, the values expected to be of most interest have input cells on the 'Key_Inputs' sheet. Last update: 5/2/2025; Version 1.1 corrects bug in reservoir thickness calculations.

Carbon storage↗

Autoignition characteristics of aircraft-type fuels

The ignition delay characteristics of Jet A, JP 4, no. 2 diesel, cetane and an experimental referee broad specification (ERBS) fuel in air at inlet temperatures up to 1000 K, pressures of 10, 15, 20, 25 and 30 atm, and fuel air equivalence ratios of 0.3, 0.5, 0.7 and 1.0 were mapped. Ignition delay times in the range of 1 to 50 msec at freestream flow velocities ranging from 20 to 100 m/sec were obtained using a continuous flow test apparatus which permitted independent variation and evaluation of the effect of temperature, pressure, flow rate, and fuel/air ratio. The ignition delay times for all fuels tested appeared to correlate with the inverse of pressure and the inverse exponent of temperature. With the exception of pure cetane, which had the shortest ignition delay times, the differences between the fuels tested did not appear to be significant. The apparent global activation energies for the typical gas turbine fuels ranged from 38 to 40 kcal/mole, while the activation energy determined for cetane was 50 kcal/mole. In addition, the data indicate that for lean mixtures, ignition delay times decrease with increasing equivalence ratio. It was also noted that physical (apparatus dependent) phenomena, such as mixing (i.e., length and number of injection sites) and airstream cooling (due to fuel heating, vaporization and convective heat loss) can have an important effect on the ignition delay.

Spadaccini, L. J.↗

Investigation of light source and scattering medium related to vapor-screen flow visualization in a supersonic wind tunnel

Methods for increasing the radiant in light sheets used for vapor screen set-ups were investigated. Both high-pressure mercury arc lamps and lasers were considered. Pulsed operation of the air-cooled 1-kW lamps increased the light output but decreased reliability. An ellipsoidal mirror improved the output of the air-cooled lamps by concentrating the light but increased the complexity of the housing. Water-cooled-4-kW lamps coupled with high-aperture Fresnel lenses provided reasonable improvements over the air-cooled lamps. Fanned laser beams measurements of scattered light versus dew point made in conjunction with successful attempts to control the fluid injection. A number of smoke generators are described and test results comparing smoke and vapor screens are shown. Finally, one test included a periscope system to relay the image to a camera outside the flow.

Snow, W. L.↗