Search NASA⌕ Search

SEARCH · Search NASA

Results for “operational efficiency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Can section 45Q tax credit foster decarbonization? A case study of geologic carbon storage at Acid Gas Injection wells in the Permian Basin

Carbon capture, utilization, and storage (CCUS) is an important pathway for meeting climate mitigation goals. While the economic viability of CCUS is well understood, previous studies do not evaluate the economic feasibility of carbon capture and storage (CCS) in the Permian Basin specifically regarding the new Section 45Q tax credits. We developed a technoeconomic analysis method, evaluated the economic feasibility of CCS at the acid gas injection (AGI) wells, and assessed the implication of Section 45Q tax credits for CCS at the AGIs. We find that the compressors, well depth, and the permit and monitoring costs drive the facility costs. Compressors are the predominant contributors to capital and operating expenditure driving the levelized cost of CO 2 storage. Strategic cost reduction measures identified include 1) sourcing of low-cost electricity and 2) optimizing operational efficiency in well operations. In evaluating the impact of the tax credits on CCS projects, facility scale proved decisive. We found that facilities with an annual injection rate exceeding 10,000 MT storage capacity demonstrate economic viability contingent upon the procurement of inputs at the least cost. The new construction of AGI wells were found to be economically viable at a storage capacity of 100,000 MT. The basin is heavily focused on CCUS (tax credit – $\$$65/MT CO 2 ), which overshadows CCS ($\$$85/MT CO 2 ) opportunities. Balancing the dual objectives of CCS and CCUS requires planning and coordination for optimal resource and pore space utilization to attain the basin's decarbonization potential. We also found that CCS on AGI is a lower cost CCS option as compared to CCS on other industries.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Automated Calibration System for Beam Current Monitor

The Beam Current Monitor (BCM) measures the instantaneous current in a beam. This work aims to develop an automated calibration system for the BCM to address the need for calibration without interrupting beam operation. We strive to create a synchronous calibration method integrated into the master timeline by utilizing the pulsed nature of synchrotrons to run calibration pulses during inter-pulse gaps. This improvement should enhance operational efficiency, ensure safe operation, and help mitigate beam loss, all by enabling intermittent calibration during the operation of the accelerator. This is accomplished by developing a Python program that interfaces with a Keithley 6221 DC and AC source and a Keithley 2182A Nanovoltmeter. The program configures both of these devices to perform a selected mode of the current sweep, allows for the initiation of the current sweep, collects the measured voltage data from the 2182A, stores the collected data to the computer in a CSV file, and graphs the collected data.

Haller, James↗

UPC++ as_eager Working Group Draft, Revision 2020.6.2

This draft proposes an extension for a new future-based completion variant that can be more effectively streamlined for RMA and atomic access operations that happen to be satisfied at runtime using purely node-local resources. Many such operations are most efficiently performed synchronously using load/store instructions on shared-memory mappings, where the actual access may only require a few CPU instructions. In such cases we believe it’s critical to minimize the overheads imposed by the UPC++ runtime and completion queues, in order to enable efficient operation on hierarchical node hardware using shared-memory bypass. The new upcxx::{source,operation}_cx::as_eager_future() completion variant accomplishes this goal by relaxing the current restriction that future-returning access operations must return a non-ready future whose completion is deferred until a subsequent explicit invocation of user-level progress. This relaxation allows access operations that are completed synchronously to instead return a ready future, thereby avoiding most or all of the runtime costs associated with deferment of future completion and subsequent mandatory entry into the progress engine. We additionally propose to make this new as_eager_future() completion variant the new default completion for communication operations that currently default to returning a future. This should encourage use of the streamlined variant, and may provide performance improvements to some codes without source changes. A mechanism is proposed to restore the legacy behavior on-demand for codes that might happen to rely on deferred completion for correctness. Finally, we propose a new as_eager_promise() completion variant that extends analogous improvements to promise-based completion, and corresponding changes to the default behavior of as_promise().

97 MATHEMATICS AND COMPUTING↗

Future Vision for Autonomous Ocean Observations

Autonomous platforms already make observations over a wide range of temporal and spatial scales, measuring salinity, temperature, nitrate, pressure, oxygen, biomass; and many other parameters. However, the observations are not comprehensive. Future autonomous systems need to be more affordable, more modular, more capable and easier to operate. Creative new types of platforms and new compact, low power, calibrated and stable sensors are under development to expand autonomous observations. Communications and recharging need bandwidth and power which can be supplied by standardized docking stations. In situ power generation will also extend endurance for many types of autonomous platforms, particularly autonomous surface vehicles. Standardized communications will improve ease of use, interoperability, and enable coordinated behaviors. Improved autonomy and communications will enable adaptive networks of autonomous platforms. Improvements in autonomy will have three aspects: hardware, control, and operations. As sensors and platforms have more onboard processing capability and energy capacity, more measurements become possible. Control systems and software will have the capability to address more complex states and sophisticated reactions to sensor inputs, which allows the platform to handle a wider variety of circumstances without direct operator control. Operational autonomy is increased by reducing operating costs. To maximize the potential of autonomous observations new standards and best practices are needed. In some applications, focus on common platforms and volume purchases could lead to significant cost reductions. Cost reductions could enable order-of-magnitude increases in platform operations and increase sampling resolution for a given level of investment. Energy harvesting technologies should be integral to the system design, for sensors, platforms, vehicles, and docking stations. Connections are needed between the marine energy and ocean observing communities to coordinate among funding sources, researchers, and end users. Regional teams should work with global organizations such as IOC/GOOS in governance development. International networks such as EGO for the emerging glider operations should also provide a forum for addressing governance. Networks of multiple vehicles can improve operational efficiencies and transform operational patterns. There is a need to develop operational architectures at regional and global scales to provide a backbone for active networking of autonomous platforms.

47 OTHER INSTRUMENTATION↗

High-fidelity wave data from MarineLabs CoastScout™ buoys supporting WEC demonstration at Scripps Pier

Two MarineLabs CoastScout™ buoys were deployed off La Jolla, California in February 2020 to provide high-resolution wave elevation time series data in support of CalWave Power Technologies’ XWave WEC deployment. The buoys are positioned approximately 300m from a longterm wave monitoring station operated by the Coastal Data Information Program. Both CoastScout hull types showed excellent agreement with the reference Datawell Directional Waverider MkIII (Hs r 2 =0.94, m0 r 2 =0.88). The CoastScout buoys maintained 100% uptime throughout an initial 6- month intercomparison period. CalWave used 5-Hz wave train data from this period to drive physical hardware-in-the-loop tests of the XWave power take-off. Throughout the deployment, the CoastScout buoys will provide near-real-time bulk wave parameters to help CalWave operators safely and efficiently operate the WEC. In post-processing, high-fidelity wave resolution will be used to associate individual waves with onboard measurements from Fiber Bragg Grating strain gauges and external pressure sensors.

16 TIDAL AND WAVE POWER↗

Deep-Learning-Based Multi-Timescale Load Forecasting in Buildings: Opportunities and Challenges from Research to Deployment

Electricity load forecasting for buildings and campuses is becoming increasingly important as the penetration of distributed energy resources (DERs) grows. Efficient operation and dispatch of DERs require reasonably accurate predictions of future energy consumption in order to conduct near-real-time optimized dispatch of on-site generation and storage assets. Electric utilities have traditionally performed load forecasting for load pockets spanning large geographic areas, and therefore, forecasting has not been a common practice by buildings and campus operators. Given the growing trends of research and prototyping in the grid-interactive efficient buildings domain, characteristics beyond simple algorithm forecast accuracy are important in determining the algorithm's true utility for smart buildings. Other characteristics include the overall design of the deployed architecture and the operational efficiency of the forecasting system. In this work, we present a deep-learning-based load forecasting system that predicts the building load at 1-hour intervals for 18 hours in the future. We also discuss challenges associated with the real-time deployment of such systems as well as the research opportunities presented by a fully functional forecasting system that has been developed within the National Renewable Energy Laboratory's Intelligent Campus program.

building load forecasting↗

Long and Winding Road to Higher Efficiency-The RTU Story: Preprint

Rooftop units (RTUs) and other packaged heating, ventilating, and air-conditioning (HVAC) equipment consume more than four quads of energy annually while conditioning more than 50% of the commercial building floor area in the United States. Historically, these systems have low operating efficiencies and receive infrequent maintenance. In addition, the market has a low first cost, run-to-failure, like-for-like replacement mentality and has been slow to adopt change. This paper explores the broad market transformation that has resulted in higher efficiencies and tremendous energy savings. Although there are many factors in this market transformation, this paper highlights: research behind advancements in components and controls; adoption of an operational efficiency metric; raising the bar for high efficiency with the RTU Challenge; market barriers overcome through the Advanced RTU Campaign; upstream and midstream incentive programs and HVAC distribution networks; alignment of the market efficiency drivers of ASHRAE Standard 90.1, federal minimum efficiency standards, the ENERGY STAR® program, and the Consortium for Energy Efficiency's (CEE's) efficiency tiers. Measures of the market transformation include more than 50% increase in RTU efficiencies, more than 1 billion kWh saved and 160,000 RTUs upgraded with high-efficiency measures by the Advanced RTU Campaign partners, large increases of high-efficiency RTUs purchased through incentive programs, and the largest energy savings from any federal minimum standards action. Although these results are impressive, the market transformation is just beginning, and there remain exciting opportunities for improvements in equipment efficiencies and improved operating performance with advanced controls and fault detection and diagnostics.

30 DIRECT ENERGY CONVERSION↗

Environmentally improved CdTe photovoltaic recycling through novel technologies and facility location strategies

Abstract Photovoltaic waste is projected to reach up to 78 million tons across globally dispersed locations through 2050. Current recycling infrastructure is inadequate to process these waste volumes responsibly. This necessitates commercializing novel, environmentally advantageous photovoltaic recycling technologies that improve upon incumbent industrial operations. CdTe photovoltaic recycling is a promising candidate for improvements as 25,000 tons of spent modules are recycled worldwide annually. This paper evaluates the operational performance and compares six novel technologies, the incumbent technology used in industry and one technology which extends the incumbent process across ten environmental impact categories. The tradeoff between incurring a transportation burden (ship or road) to recycle in a large‐scale centralized facility with a higher operational efficiency and avoiding transportation by recycling in a small‐scale decentralized facility with a lower operational efficiency is evaluated. Thermal delamination to eliminate the ethylene vinyl acetate and separate the photovoltaic glass panels is preferable to the incumbent mechanical process across nine environmental impact categories and decreases the climate‐change impact of CdTe photovoltaic recycling by 23%. Bath and probe sonication are ineffective for delamination, and the use of organic solvents is more environmentally burdensome than the incumbent mechanical process. Centralized recycling with shipping is environmentally preferable than with road‐based transportation. For every 100‐km increase in road transportation from the decentralized to the centralized facility, the inventory requirement in the centralized facility should be 6% lower than the decentralized facility for centralized recycling to have a lower climate‐change impact than decentralized recycling. The corresponding value for shipping is 0.4%.

Ravikumar, Dwarakanath↗

Calista Energy Management Assistance Initiative

The Calista Energy Management Assistance Initiative (CEMAI) provided technical assistance and capacity building for 56 Tribal communities in the Calista Region of Alaska as an effort to reduce costs, improve operational efficiency, enhance human capacity, and job opportunities. CEMAI catalyzed and guided numerous efforts into a consolidated and effective initiative that brought rural energy best practices, economies of scale, operational efficiencies, human capacity, and economic development to the forefront. Calista Corporation (Calista) is one of thirteen Alaska Native Regional Corporations created under the Alaska Native Claims Settlement Act of 1971 (ANCSA) in the settlement of aboriginal land claims. Calista was incorporated in Alaska on June 12, 1972. The Calista Region covers Alaska’s Bethel and Kusilvak (formerly Wade Hampton) Census areas and includes 56 communities. Calista partnered with Nuvista Light and Electric Cooperative (Nuvista) on the Department of Energy, Office of Indian Energy (DOE-OIE), CEMAI project. Nuvista is a non-profit that seeks to reduce energy costs and provide renewable sources of energy to the people of western Alaska. It is founded and led by a non-profit, Tribe, Native Corporations (including Calista), energy organizations, and Alaska Native stakeholders in the Yukon-Kuskokwim Delta (YK-D) Region; covering the same service boundaries and communities served by Calista. This partnership allowed Calista to direct the project work with local energy experts to respond to community needs. In this arrangement, Calista added credibility and regional accountability while Nuvista added energy-specific expertise and skill set in project management. The delivery of the CEMAI Workplan included short-term or on-demand responses to specific technical assistance requests from communities in addition to longer-term strategically directed activities such as workshops, coordinated training, and capacity development efforts across the region. CEMAI’s Workplan aimed to enhance communities’ readiness for establishing renewable energy projects and implementing energy efficiency initiatives. The CEMAI objectives included: (1) Identifying common operational needs and improvement opportunities for entities with an energy interest or responsibility. (2) Providing access to multi-level expertise to address existing challenges. (3) Developing specialized training programs to build local capacity and community readiness. (4) Nurturing the creation of regional support networks. (5) Increasing access to regional, state, and federal energy initiatives, funding, and expertise. (6) Improving technical skills, provide livable wages, and job opportunities.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A novel approach for produced water treatment: Supercritical water oxidation and desalination

Produced water generated from oil and gas operations contains significant quantities of environmentally hazardous hydrocarbons, organic chemicals, and inorganic salts. Environmental regulations with impaired water disposal mandates produced water treatment and desalination. Industry standard desalination technologies are energy-intensive and mandate extensive produced water pre-treatment including removal of hydrocarbons constituents for efficient operations. Herein this study investigates a novel process intensification approach integrating supercritical water oxidation (SCWO) unit operation with a supercritical water desalination (SCWD) process for energy efficient produced water treatment and desalination. The coupled SCWD-SCWO process is found to be very energy-efficient and cost effective than existing industry standard desalination technologies. For energy efficient operation, the heat generated from the SCWO of hydrocarbons present in the produced water is used for power generation using a high efficiency and low-cost re-heat Rankine cycle process. The cost of treating produced water with proposed SCWO-SCWD process is independent of the salt concentration. The proposed process has the potential to offer step-change improvements over conventional processes in both the efficiency and cost of produced water treatment: for example, a cost and energy saving of 70% and 100% is calculated for the treatment of produced water containing 250 g/l salt and 10.6 g/l hydrocarbon.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Preliminary Investigation on the Performance of a Dual-Source Heat Pump using both the Air and the Ground

Air source heat pumps (ASHPs) and ground source heat pumps (GSHPs) are the two most common types of electric-driven heat pumps in the marketplace to replace fossil fuel-based heating systems. However, the performance and efficiency of ASHPs depend on the ambient air conditions. Therefore, ASHPs usually are equipped with electric resistance heaters to provide supplemental heating when the ambient temperature is low, and the heating demand is high. The electric resistance heaters could result in high power draws when they are turned on. On the other hand, due to the relatively steady temperature of the ground, GSHPs are more energy efficient than ASHPs when providing space heating and cooling to the buildings. However, the adoption of GSHP is hindered by its high initial cost, mostly due to the cost of drilling boreholes for installing ground heat exchangers (GHE). To solve the above issues, our study investigates the performance of dual-source heat pumps (DSHPs) with respect to that of ASHPs and GSHPs. The DSHP will use ambient air when its temperature is favorable for the efficient operation of the heat pump. When the ambient temperature is too hot or too cold, the ground source will be utilized to retain the high-efficiency operation of the heat pump. Because the cumulative thermal load of the GHE is shared with the ambient air, the size of the GHE could be smaller than those of the conventional GSHPs. The study will model the DSHP and simulate its performance in providing heating and cooling for a typical single-family house in regions with hot, mild, or cold climates. In addition, the required GHE size of the DSHP system will be determined through annual simulations and compared with that of conventional GSHPs.

Anees, Fady↗

Building Monitoring and Energy Efficiency Training for Small and Mid-Sized Commercial Buildings in Non-Urbanized Areas of Alaska

The goal of this project was to create an effective training that increases understanding, competency and capacity in monitoring critical building data. Mentorship, verification and follow-up ensured participants now have necessary skills to install and maintain building monitoring systems. This training sought to empower building managers and maintenance staff to properly and efficiently operate their buildings for energy savings and increased lifespan of equipment. Through the project, participants’ knowledge of the building was increased through hands-on training using a familiar building environment and eliminating common barriers to effective training through peer-to peer delivery. In successful cases the host organization will save money and resources due to more efficient operation of building equipment already in place.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Electrostatic generator electrode-centering and seismic-isolation system for flywheel-based energy storage modules

Robust electro-static (ES) device embodiments, with application to energy storage flywheels as an example, are described that provide reliable, high-efficiency operation in the presence of thermal and mechanical perturbations, as well as seismic events. Electro-static generators and motors, when augmented with magnetic bearings, passive three-dimensional stabilization techniques and dynamic touch-down bearings, enable robust performance in the face of these environmental concerns, as well as efficient operation during typical operational sequences, including spin-up and steady-state modalities.

25 ENERGY STORAGE↗

Electrostatic generator electrode-centering and seismic-isolation system for flywheel-based energy storage modules

Robust electro-static (ES) device embodiments, with application to energy storage flywheels as an example, are described that provide reliable, high-efficiency operation in the presence of thermal and mechanical perturbations, as well as seismic events. Electro-static generators and motors, when augmented with magnetic bearings, passive three-dimensional stabilization techniques and dynamic touch-down bearings, enable robust performance in the face of these environmental concerns, as well as efficient operation during typical operational sequences, including spin-up and steady-state modalities.

Post, Richard F.↗

Hamilton: Flexible, Open Source $10 Wireless Sensor System for Energy Efficient Building Operation

Sensors for improving building performance are rapidly populating the market, driven in part by the drive to reduce greenhouse gas emissions resulting from energy production as well as improve the interior environment for healthy and more productive spaces. UC Berkeley has led wireless sensor development over the past 25 years (e.g., Telos mote), with the Hamilton (named after Alexander Hamilton on the US $10 bill) as the most recent. The Hamilton sensor was designed as a low-cost high-performance sensor that is modular and interoperable. The objective of the Hamilton project was to create, evaluate and establish the technological foundations for secure and easy to deploy building energy efficiency applications utilizing pervasive, low-cost wireless sensors integrated with traditional Building Management Systems (BMS), consumer-sector building components, and powerful data analytics. The project included iterative hardware design, incorporating a high-performance database (BTrDb, http://btrdb.io/), creating and iterating the development of secure data middleware (BOSSwave, WAVE/WAVEMQ), working with and pushing the development of an open-source tiny operating system RiotOS, and implementing and improving protocols such as Thread/OpenThread and TCP/IP. The hardware benefited from careful design to drive down the cost; the design included a System-on-a-Chip (SoC), chip antenna, single crystal and five passive components. Careful design of the operating system created a low-power design to enable a long life with small batteries. The hardware included several sensors: temperature, radiant temperature, relative humidity, magnetometer, accelerometer, and light, with an optional occupancy (Passive InfraRed) sensor. The project was the basis of several applications, both internal to the research team and other researchers and professionals at other institutions. Several applications used the sensor hardware as the basis for other complex devices. Other applications used the sensors to improve building performance through interoperating with the building Heating Ventilation and Air-Conditioning (HVAC) system, such as using occupancy and/or distributed temperature sensing to reduce HVAC zone energy while still providing thermal comfort and to reduce peak loads in small commercial buildings. We demonstrated cloud-based energy analytics, implemented a schedule and a Model Predictive Controller in a small commercial building to optimize HVAC energy, occupancy and electricity price. Initial integration of these technological innovations was performed through the creation of execution containers containing the WAVE agent and various driver, proxy, or building system function logic. The research added to the understanding of efficient sensor hardware, secure middleware, time-series data management (high performance database), efficient communication protocols, and interoperating with applications and building systems. The project showed the technical effectiveness and economic feasibility of creating a low-cost, modular, and easy-to-deploy sensor. Through conversations with multiple end users, the research team discovered that many customers wanted data management and services in addition to the sensors. HamiltonIOT developed packages of sensors, border router, and data services to provide a seamless “plug-and-play” sensor deployment. Some customers were willing to pay for higher quality sensors (such as light); some customers wanted a robust enclosure (waterproof).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Integrating 5G Technology for Improved Process Monitoring and Network Slicing in ICS

Industrial Control Systems (ICS) are crucial for monitoring physical processes that support essential cyber-enabled services like power generation. The use of proprietary communication and lack of effective intrusion detection mechanisms pose constraints for efficient operation. Therefore, there is a need to modernize these systems with decentralized technologies like Edge Computing and 5G. However, integrating 5G and Edge Computing into large-scale ICS networks presents implementation and performance challenges. To address these challenges, this paper proposes an integrated ICS architecture that combines 5G and Edge Computing technologies with traditional ICS protocols. The objective is to minimize implementation and operational difficulties while improving the monitoring of physical processes and enabling robust intrusion detection. The proposed architecture outlines the necessary components, services, and communication protocols required for the integration of 5G and Edge Computing.

Aguayo, Jared M.↗

Prevalence of typical operational problems and energy savings opportunities in U.S. commercial buildings

In the United States, as much as 30% of the 19 EJ that commercial buildings consume is considered excess. Much of the excess energy is due to the inability to manage building operations efficiently. Because almost 20% of the total primary energy consumption is associated with commercial buildings, significant energy reductions in this sector are needed to mitigate climate change. Therefore, many cities and states are mandating periodic “tune-ups” of these buildings to eliminate excess energy consumption. Although the benefits of tune-ups and retro-commissioning are clear, focusing these mandates to look for specific opportunities has been a challenge because of the lack of studies that document the prevalence of opportunities. Therefore, we analyzed building automation system data from 151 buildings across the United States to document common operational problems and opportunities to improve building operations. This analysis showed that opportunities to improve building operations exist in almost every building. These opportunities were not strongly correlated with building vintage or size, but were reflective of how the buildings are operated. The prevalence of the top 20 opportunities ranged between 74% and 23%, with 40% of these associated with air-handling units. The rest of the opportunities are associated with schedules, chilled and hot-water distribution, and zone controls. Of the 151 buildings, 69 of them implemented corrective actions of some or all opportunities that were identified. Implementation varied across the Re-tuning categories, with 60% for schedule opportunities, 50% for zone opportunities, over 40% for the air-handling unit and hot-water opportunities, and 35% of the chilled-water opportunities. There was wide variation in whole building energy savings, ranging from 0 to 50% and 0 to 18 $/m2 with median percent annual whole building savings of 12% and median normalized annual cost savings of $1.75/m2. In addition to documenting these key findings, the paper provides a list of opportunities that can be automatically and continuously identified and corrected and offers a list of those opportunities that should be the focus of the mandates.

Katipamula, Srinivas↗

Introduction to (Photo)electrocatalysis For Renewable Energy

Humanity is facing a significant and growing energy demand, necessitating a new energy paradigm built on clean and abundant renewable energy.1 Within this context, electrocatalysis and (photo)electrocatalysis hold great promise for enabling renewable energies such as solar and wind power to overcome the transient nature of their energy output.2-6 Developing catalysts that operate efficiently and selectively, and that are also robust, has been the focus of much research. This special issue brings together the latest advances in the fundamental and applied science addressing the synthesis, characterization, mechanisms, and performance of (photo)electrocatalysts for energy storage and conversion of small molecules into useful specialty and commodity chemicals and fuels. The electrocatalysts and (photo)electrocatalysts highlighted in this issue include metalloenzymes, homogeneous and supported molecular catalysts, and diverse heterogeneous nanoparticulate and thin film systems. The reports span across basic and applied studies and encompass both experimental and theoretical investigations.

Dey, Abhishek↗