Search NASA⌕ Search

SEARCH · Search NASA

Results for “optical backscatter reflectometry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

27 records · Page 2

Physical Characterization of Solid-Liquid Slurries at High Weight Fractions Using Optical and Ultrasonic Methods, Final Report

Remediation of highly radioactive waste is a major technical and programmatic challenge for the DOE. Rapid, on-line physical characterization of highly concentrated slurries is required for the safe and efficient remediation of 90 million gallons of high level radioactive waste (HLW), sodium bearing waste, and mixed waste. The research presented here, describes a collaborative effort between Pacific Northwest National Laboratory (PNNL) and the University of Washington to directly address the need for rapid on-line characterization of the physical properties of HLW slurries during all phases of the remediation process, from in-tank characterization of sediments to monitoring of the concentration, particle size, and degree of agglomeration and gelation of slurries during transport. Near-surface characterization of the slurry flow in the particle size range from nanometer to micrometer is examined using optical low coherence reflectometry. Volumetric characterization at depths in the slurry flow, up to several centimeters in the particle size range from the micrometer to millimeter, is realized by utilizing ultrasonic backscatter and diffuses fields. One of the strengths, the teaming up of significant talents in both experimental and theoretical optics (University of Washington) and in ultrasonics [Pacific Northwest National Laboratory (PNNL)] provides a synergistic approach to integrate these complimentary techniques. One of the benefits of this combined approach is the physical characterization of HLW over a concentration and particle size range that is broader than can be achieved with today’s technology. This will avoid a costly increase in waste stream volume due to excess dilution, and will lessen chance of plugging pipes that could shut down expensive processing lines.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Identifications and classifications of human locomotion using Rayleigh-enhanced distributed fiber acoustic sensors with deep neural networks

Abstract This paper reports on the use of machine learning to delineate data harnessed by fiber-optic distributed acoustic sensors (DAS) using fiber with enhanced Rayleigh backscattering to recognize vibration events induced by human locomotion. The DAS used in this work is based on homodyne phase-sensitive optical time-domain reflectometry (φ-OTDR). The signal-to-noise ratio (SNR) of the DAS was enhanced using femtosecond laser-induced artificial Rayleigh scattering centers in single-mode fiber cores. Both supervised and unsupervised machine-learning algorithms were explored to identify people and specific events that produce acoustic signals. Using convolutional deep neural networks, the supervised machine learning scheme achieved over 76.25% accuracy in recognizing human identities. Conversely, the unsupervised machine learning scheme achieved over 77.65% accuracy in recognizing events and human identities through acoustic signals. Through integrated efforts on both sensor device innovation and machine learning data analytics, this paper shows that the DAS technique can be an effective security technology to detect and to identify highly similar acoustic events with high spatial resolution and high accuracies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

RBS, XRR and optical reflectivity measurements of Ti-TiO{sub 2} thin films deposited by magnetron sputtering

Highlights: Black-Right-Pointing-Pointer The single-, bi- and tri-layered films of Ti-TiO{sub 2} deposited onto Si(1 1 1) substrates. Black-Right-Pointing-Pointer Three methods RBS, XRR, optical reflectometer were used. Black-Right-Pointing-Pointer The real thickness of each layer was smaller than 50 nm. Black-Right-Pointing-Pointer Ti and TiO{sub 2} film-densities were slightly lower than the corresponding bulk values. -- Abstract: Single-, bi- and tri-layered films of Ti-TiO{sub 2} system were deposited by d.c. pulsed magnetron sputtering from metallic Ti target in an inert Ar or reactive Ar + O{sub 2} atmosphere. The nominal thickness of each layer was 50 nm. The chemical composition and its depth profile were determined by Rutherford backscattering spectroscopy (RBS). Crystallographic structure was analysed by means of X-ray diffraction (XRD) at glancing incidence. X-ray reflectometry (XRR) was used as a complementary method for the film thickness and density evaluation. Modelling of the optical reflectivity spectra of Ti-TiO{sub 2} thin films deposited onto Si(1 1 1) substrates provided an independent estimate of the layer thickness. The combined analysis of RBS, XRR and reflectivity spectra indicated the real thickness of each layer less than 50 nm with TiO{sub 2} film density slightly lower than the corresponding bulk value. Scanning Electron Microscopy (SEM) cross-sectional images revealed the columnar growth of TiO{sub 2} layers. Thickness estimated directly from SEM studies was found to be in a good agreement with the results of RBS, XRR and reflectivity spectra.

36 MATERIALS SCIENCE↗

Calibration of Distributed Temperature Sensors Using Commercially Available SMF-28 Optical Fiber From 22 °C to 1000 °C

Optical frequency domain reflectometry (OFDR) is a family of optical techniques which can be used to produce distributed temperature measurements from the spectral shift of an interference pattern based on the Rayleigh backscatter signature of an optical fiber. Adaptive signal processing techniques have recently been used with OFDR to record meaningful spectral shift data from commercially available SMF-28 optical fibers heated beyond 950 °C. Furthermore, a correlation between the measured spectral shift and temperature has not yet been developed at these high temperatures. To extend the measurable temperature range of OFDR in SMF-28, this work describes the development of such a correlation from room temperature (22 °C) to 1000 °C. The relationship between spectral shift and temperature change over this range was found to be best characterized by the fourth-order polynomial ΔT=(-4.241 * 10 -11 )S 4 + (-2.017 * 10 -7 )S 3 + (-3.677 * 10 -4 )S 2 + (-0.8057)S, where ΔT represents the temperature difference compared to the reference temperature, and S represents the spectral shift measured by the fibers. The calibration developed in this work assumes that the fiber has been fully annealed by heating the fiber to 1000 °C for a few hours. This paper is the first to demonstrate the calibration and use of SMF-28 distributed optical fiber sensors up to 1000 °C, enabled using adaptive OFDR-based signal processing.

47 OTHER INSTRUMENTATION↗

A factor limiting the accuracy of optical loss measurements in single-mode fibres: ‘frozen-in’ inhomogeneities of the Rayleigh backscatter coefficient

Backscatter coefficient fluctuations at a wavelength of 1560 nm in Fujikura FutureGuide-LWP, Corning ClearCurve XB and Corning SMF-28 ULL telecom fibres have been studied using optical time-domain reflectometry and broadband (10 nm) depolarised light. It has been shown that, under the conditions of our experiments, such fluctuations are ‘frozen-in’ and that a typical standard deviation in noiselike reflectograms is 0.16 dB, with a correlation distance no greater than 1 m. Such results have been obtained for all fibre samples. The effect studied experimentally limits the accuracy of attenuation measurements in optical fibres, especially at short fibre lengths (tens and hundreds of metres). Moreover, it should be taken into account in designing distributed physical parameter sensors using Rayleigh scattering intensity as a reference channel. Possible sources of the inhomogeneities in the fibres are discussed. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

New plasma measurements with a multichannel millimeter-wave fluctuation diagnostic system in the DIII-D tokamak (invited)

A novel multichannel, tunable Doppler backscattering (DBS)/reflectometry system has recently been developed and applied to a variety of DIII-D plasmas. Either DBS or reflectometry can be easily configured for use in a wide range of plasma conditions using a flexible quasi-optical antenna system. The multiple closely spaced channels, when combined with other fluctuation diagnostic systems, have opened up new measurements of plasma properties. For example, the toroidal and fine-scale radial structure of coherent plasma oscillations, such as geodesic acoustic modes, have been probed simultaneously in the core of high temperature plasmas by applying correlation analysis between two toroidally separated DBS systems, as well as within the multichannel array. When configured as a reflectometer, cross-correlation with electron cyclotron emission radiometry has uncovered detailed information regarding the crossphase relationship between density and temperature fluctuations. The density-temperature crossphase measurement yields insight into the physics of tokamak turbulence at a fundamental level that can be directly compared with predictions from nonlinear gyrokinetic simulations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Soft x-ray optical constants of sputtered chromium thin films with improved accuracy in the L and M absorption edge regions

In this paper, we determine with improved accuracy the complex index of refraction n = 1 - δ + iβ of sputtered chromium thin films for photon energies ranging from 25 eV to 813 eV. These data include the first absolute measurements of the absorption fine structure near the Cr-L edge. First, we verified by combining Rutherford Backscattering Spectrometry and grazing-incidence x-ray reflectometry that the sputtered thin films were pure Cr with a density consistent with tabulated values. Then, we demonstrated that the Cr surface oxide layer remains stable when the samples are exposed to air for up to 4 years. The Cr absorption coefficient β was determined from the transmittance of freestanding Cr thin films with various thicknesses, measured at the ALS synchrotron radiation source. A model is proposed to correct the transmittance data from the spectral contamination of the source. Finally, we used the new β values, combined with theoretical and tabulated data from the literature, in order to calculate the δ values by the Kramers-Kronig relation. The improvement in the accuracy of β values is demonstrated by the f-sum rule. Finally, an additional validation of the new Cr optical constants (δ, β) is performed by comparing the simulated and experimental reflectance of a Cr/B 4 C multilayer mirror near the Cr-L 2,3 edge.

36 MATERIALS SCIENCE↗

Synthetic aperture microwave imaging with active probing for fusion plasma diagnostics

A Synthetic Aperture Microwave Imaging (SAMI) system has been designed and built to obtain 2-D images at several frequencies from fusion plasmas. SAMI uses a phased array of linearly polarised antennas. The array configuration has been optimised to achieve maximum synthetic aperture beam efficiency. The signals received by antennas are down-converted to the intermediate frequency range and then recorded in a full vector form. Full vector signals allow beam focusing and image reconstruction in both real time and a post-processing mode. SAMI can scan over 16 pre-programmed frequencies in the range of 10-35GHz with a switching time of 300ns. The system operates in 2 different modes simultaneously: both a 'passive' imaging of plasma emission and also an 'active' imaging of the back-scattered signal of the radiation launched by one of the antennas from the same array. This second mode is similar to so-called Doppler backscattering (DBS) reflectometry with 2-D resolution of the propagation velocity of turbulent structures. Both modes of operation show good performance in fusion plasma experiments on Mega Amp Spherical Tokamak (MAST). We have obtained the first ever 2-D images of BXO mode conversion windows. With active probing, first ever turbulence velocity maps have been obtained. We present an overview of the diagnostic and discuss recent results. In contrast to quasi-optical microwave imaging systems SAMI requires neither big aperture viewing ports nor large 2-D detector arrays to achieve the desired imaging resolution. The number of effective 'pixels' of the synthesized image is proportional to the number of receiving antennas squared. Thus only a small number of optimised antennas is sufficient for the majority of applications. Possible implementation of SAMI on ITERand DEMO is discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Discrimination of Temperature and Strain in Brillouin Optical Time Domain Analysis Using a Multicore Optical Fiber

Brillouin optical time domain analysis is the sensing of temperature and strain changes along an optical fiber by measuring the frequency shift changes of Brillouin backscattering. Because frequency shift changes are a linear combination of temperature and strain changes, their discrimination is a challenge. Here, a multicore optical fiber that has two cores is fabricated. The differences between the cores’ temperature and strain coefficients are such that temperature (strain) changes can be discriminated with error amplification factors of 4.57 °C/MHz (69.11 μϵ /MHz), which is 2.63 (3.67) times lower than previously demonstrated. As proof of principle, using the multicore optical fiber and a commercial Brillouin optical time domain analyzer, the temperature (strain) changes of a thermally expanding metal cylinder are discriminated with an error of 0.24% (3.7%).

47 OTHER INSTRUMENTATION↗