Search NASA⌕ Search

SEARCH · Search NASA

Results for “optical displacement sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Loss-compensation technique for fiber-optic sensors and its application to displacement measurements

This report describes a new type of intensity-modulating fiber-optic sensor which has high immunity to the effects of variations in the losses of the fiber-link. A variable-splitting-ratio transducer is used to differentially modulate the intensities of the light which it transmits and reflects. Using a four-fiber optical link, light is impinged onto the transducer from either direction, and in each case, the transmitted and reflected signals are measured. These four signals are then processed to remove the effects of the fiber and connector losses. Loss-compensated sensors of angular position and displacement are described, and their outputs are shown to be highly stable despite considerable variations in the transmissivities of the fiber-link components.

Beheim, Glenn↗

In-Situ Focusing Inside a Thermal Vacuum Chamber

Traditionally, infrared (IR) space instruments have been focused by iterating with a number of different thickness shim rings in a thermal vacuum chamber until the focus meets requirements. This has required a number of thermal cycles that are very expensive as they tie up many integration and test (I&T)/ environmental technicians/engi neers work ing three shifts for weeks. Rather than creating a test shim for each iteration, this innovation replaces the test shim and can focus the instrument while in the thermal vacuum chamber. The focus tool consists of three small, piezo-actuated motors that drive two sets of mechanical interface flanges between the instrument optics and the focal- plane assembly, and three optical-displacement metrology sensors that can be read from outside the thermal vacuum chamber. The motors are used to drive the focal planes to different focal distances and acquire images, from which it is possible to determine the best focus. At the best focus position, the three optical displacement metrology sensors are used to determine the shim thickness needed. After the instrument leaves the thermal vacuum chamber, the focus tool is replaced with the precision-ground shim ring. The focus tool consists of two sets of collars, one that mounts to the backside of the interface flange of the instrument optics, and one that mounts to the backside of the interface flange of the focal plane modules. The collars on the instrument optics side have the three small piezo-actuated motors and the three optical displacement metrology systems. Before the instrument is focused, there is no shim ring in place and, therefore, no fasteners holding the focal plane modules to the cameras. Two focus tooling collars are held together by three strong springs. The Orbiting Carbon Observatory (OCO) mission spectrometer was focused this way (see figure). The motor described here had to be moved five times to reach an acceptable focus, all during the same thermal cycle, which was verified using pupil slicing techniques. A focus accuracy of .20.100 microns was achieved.

Liebe, Carl Christian↗

TRUST Sensors in Environments: Fiber Optic Displacement (SE-FOD)

The objective of the Delivery Environments (DE) Testbeds to Reduce Uncertainty in Simulations and Tests (TRUST) project is to quantify and help increase confidence in specific areas of computational and experimental capabilities that are applicable to the development, on-target assessment, and qualification of current and future delivery environments. More complete quantification of confidence in experimental and computational capabilities and the sufficient increase of confidence in those capabilities is critical to improving weapons engineering design, qualification, and assessment efforts that are critical to the current and future stockpile. Under the TRUST work package, engineers use and provide feedback on analysis tools and experimental results and create databases for efficient and responsive engineering which are currently under development.

42 ENGINEERING↗

Displacement response, detection limit, and dynamic range of fiber-optic lever sensors

The authors present the evaluation of the displacement response, detection limit, and dynamic range of fiber-optic lever sensors in a general format to establish their dependence on fiber sizes, optoelectronic detector specifications, input power, and other relevant parameters. The formations for the normalized reflected optical power change are derived for the evaluation of the optimal sensor response, the linearity range, and the minimum detectable displacement. The theoretical models are verified by an experiment which determines sensor response, modulation index, reflected optical power change, and linear response range through dynamic measurement. The application of this theoretical model to the study of a fiber-optic microphone for acoustic pressure detection is considered.

He, Gang↗

LISA technology department at JPL

The Laser Interferometer Space Antenna (LISA) project requires technology developments on many fronts. A physical understanding of the LISA subsystems is a precursor to tacjling the requirements needed to ensure a successful mission. This can only be achieved by developing the concepts in the lab prior to developing the payload. This poster presents updates on laboratory activities intended to prove the feasibility of measuring proof mass back reaction forces of less than 3fN/(square root)Hz at 1 mHz; the sensing of the proof mass position with in 2 nm/(square root)above the 3 mHz; and the resolution and accuracy of the phase-meter to better than 10 pm/(square root)Hz above the 3 mHz.

optical displacement sensor↗

Large Area Lunar Dust Flux Measurement Instrument

The instrument under development is designed to characterize the flux and size distribution of the lunar micrometeoroid and secondary ejecta environment. When deployed on the lunar surface, the data collected will benefit fundamental lunar science as well as enabling more reliable impact risk assessments for human lunar exploration activities. To perform this task, the instrument requirements are demanding. It must have as large a surface area as possible to sample the very sparse population of the larger potentially damage-inducing micrometeorites. It must also have very high sensitivity to enable it to measure the flux of small (<10 micron) micrometeorite and secondary ejecta dust particles. To be delivered to the lunar surface, it must also be very low mass, rugged and stow compactly. The instrument designed to meet these requirements is called FOMIS. It is a large-area thin film under tension (i.e. a drum) with multiple fiber optic displacement (FOD) sensors to monitor displacements of the film. This sensor was chosen since it can measure displacements over a wide dynamic range: 1 cm to sub-Angstrom. A prototype system was successfully demonstrated using the hypervelocity impact test facility at the University of Kent (Canterbury, UK). Based on these results, the prototype system can detect hypervelocity (approx.5 km/s) impacts by particles as small as 2 microns diameter. Additional tests using slow speeds find that it can detect secondary ejecta particles (which do not penetrate the film) with momentums as small as 15 pico-gram 100m/s, or nominally 5 microns diameter at 100 m/s.

Corsaro, R.↗

Thin-Layer Composite Unimorph Ferroelectric Driver Sensor Properties

Tests were conducted on 13 different configurations of a new class of piezoelectric devices called THUNDER (thin layer composite unimorph ferroelectric driver and sensor). These configurations consisted of a combination of 1, 3, 5, 7, and 9 layers of 25.4 micron thick aluminium as a backing material, with and without a top layer of 25.4 micrometer aluminum. All of these configurations used the same piezoelectric ceramic wafer (PZT-5A) with dimensions of 5.08 x 3.81 x 0.018 cm. The above configurations were tested at two stages of the manufacturing process: before and after repoling. The parameters measured included frequency, driving voltage. displacement, capacitance, and radius of curvature. An optic sensor recorded the displacement at a fixed voltage(100 - 400 V peak to peak) over a predetermined frequency range (1 - 1000 Hz). These displacement measurements were performed using a computer that controlled the process of activating and measuring the displacement of the device. A parameter alpha was defined which can be used to predict the which configuration will produce the most displacement for a free standing device.

Mossi, Karla M.↗

TRUST Contact Thermal Conductance (TRUST-CTC) Report: FY24

The objective of the Delivery Environments (DE) Testbeds to Reduce Uncertainties in Simulations and Tests (TRUST) project is to quantify and help increase confidence in specific areas of computational and experimental capabilities that are applicable to current and future delivery environments. More complete quantification of confidence in experimental and computational capabilities and the sufficient increase of confidence in those capabilities is critical to improving weapons engineering design, qualification, and assessment efforts that are critical to the current and future stockpile. Staff development will include cross-discipline collaboration to provide engineers with experience in both numerical simulations and experimental methods. This work uses and provides feedback on analysis tools and experimental results databases for efficient and responsive engineering which are currently under development. TRUST currently includes five testbeds and their associated engineering analysis baseline models (EABMs): 1. contact thermal conductivity, (CTC) 2. nonlinear dynamics, (ND) 3. sensors in environments for accelerometers, (SEA) 4. sensors in environments for fiber optic displacement gages, and (SEFOD) 5. sensors in environments for thermocouples (SETC). The TRUST project uses single-feature testbeds to quantify uncertainties in specific models and experiments and to identify capability development needs that can help to reduce these uncertainties. Each testbed is designed, configured, and tested in collaboration with groups with design and experimental capability: E-14 and MPA-CINT. The complementary simulations are conducted using W-13 analysis tools and stored in model repositories with plans for incremental progress toward EABM requirements. W-13 extends and exercises the testbed simulations in collaboration with experimentalists for uncertainty quantification of current and future materials, geometries, and environments. Additionally, TRUST is intended to provide engineers in W-13 and E-14 with experience in both numerical simulations and experimental methods through cross-discipline collaborations. Following the introduction to the TRUST project, the remainder of this report focuses on experimental and analytical efforts conducted in Fiscal Year (FY) 2024 relevant to the TRUST Contact Thermal Conductance (CTC) testbed.

42 ENGINEERING↗

Model-Based Wavefront Control for CCAT

The 25-m aperture CCAT submillimeter-wave telescope will have a primary mirror that is divided into 162 individual segments, each of which is provided with 3 positioning actuators. CCAT will be equipped with innovative Imaging Displacement Sensors (IDS) inexpensive optical edge sensors capable of accurately measuring all segment relative motions. These measurements are used in a Kalman-filter-based Optical State Estimator to estimate wavefront errors, permitting use of a minimum-wavefront controller without direct wavefront measurement. This controller corrects the optical impact of errors in 6 degrees of freedom per segment, including lateral translations of the segments, using only the 3 actuated degrees of freedom per segment. The global motions of the Primary and Secondary Mirrors are not measured by the edge sensors. These are controlled using a gravity-sag look-up table. Predicted performance is illustrated by simulated response to errors such as gravity sag.

edge sensor↗

Intensity Modulated Fiber Optic Sensor: A Novel Grid Measurement Unit

This paper presents a novel approach to physical displacement-based power grid measuring via an Intensity Modulated Fiber Optic Sensor (IMFOS). An IMFOS utilizes one fiber to transmit the intensity modulation light from its Electro-Optic controller to a fiber optic probe. The power grid voltage and current can induce physical displacements in transducers via the piezoelectric effect and the Lorentz law, respectively, which then result in a distance change between the optical probe and the reflective surface of the transducers. In parallel, multiple fibers are used to collect the reflective light for electro-optic conversion. Furthermore, a National Instruments-based characterization platform is set up for performance evaluation. Here, the testing result demonstrates that the IMFOS is immune to the inherent DC and low-frequency saturation issues prevalent in conventional potential and current transformers. Finally, the IMFOS is implemented in a Universal Grid Analyzer to illustrate its applicability for phasor estimation in actual power grids.

42 ENGINEERING↗

Common Practice Lightning Strike Protection Characterization Technique to Quantify Damage Mechanisms on Composite Substrates

To support FAA certification airworthiness standards, composite substrates are subjected to lightning direct-effect electrical waveforms to determine performance characteristics of the lightning strike protection (LSP) conductive layers used to protect composite substrates. Test results collected from independent LSP studies are often incomparable due to variability in test procedures & applied practices at different organizations, which impairs performance correlations between different LSP data sets. Under a NASA supported contract, The Boeing Company developed technical procedures and documentation as guidance in order to facilitate a test method for conducting universal common practice lightning strike protection test procedures. The procedures obtain conformity in future lightning strike protection evaluations to allow meaningful performance correlations across data sets. This universal common practice guidance provides the manufacturing specifications to fabricate carbon fiber reinforced plastic (CFRP) test panels, including finish, grounding configuration, and acceptable methods for pretest nondestructive inspection (NDI) and posttest destructive inspection. The test operations guidance elaborates on the provisions contained in SAE ARP5416 to address inconsistencies in the generation of damage protection performance data, so as to provide for maximum achievable correlation across capable lab facilities. In addition, the guidance details a direct effects test bed design to aid in quantification of the multi-physical phenomena surrounding a lightning direct attachment supporting validation data requirements for the development of predictive computational modeling. The lightning test bed is designed to accommodate a repeatable installation procedure to secure the test panel and eliminate test installation uncertainty. It also facilitates a means to capture the electrical waveform parameters in 2 dimensions, along with the mechanical displacement and thermal heating parameters which occur during lightning attachment. Following guidance defined in the universal common practice LSP test documents, protected and unprotected CFRP panels were evaluated at 20, 40 and 100KAmps. This report presents analyzed data demonstrating the scientific usefulness of the common practice approach. Descriptions of the common practice CFRP test articles, LSP test bed fixture, and monitoring techniques to capture the electrical, mechanical and thermal parameters during lightning attachment are presented here. Two methods of measuring the electrical currents were evaluated, inductive current probes and a newly developed fiberoptic sensor. Two mechanical displacement methods were also examined, optical laser measurement sensors and a digital imaging correlation camera system. Recommendations are provided to help users implement the common practice test approach and obtain LSP test characterizations comparable across data sets.

Szatkowski, George N.↗

Proton Nonionizing Energy Loss (NIEL) for Device Applications

Nonionizing energy loss (NIEL) is a quantity that describes the rate of energy loss due to atomic displacements as a particle traverses a material. The product of the NIEL and the particle fluence (time integrated flux) gives the displacement damage energy deposition per unit mass of material. NIEL plays the same role to the displacement damage energy deposition as the stopping power to the total ionizing dose (TID). The concept of NIEL has been very useful for correlating particle induced displacement damage effects in semiconductor and optical devices. Many studies have successfully demonstrated that the degradation of semiconductor devices or optical sensors in a radiation field can be linearly correlated to the displacement damage energy, and subsequently to the NIEL deposited in the semiconductor devices or optical sensors. In addition, the NIEL concept was also useful in the study of both Si and GaAs solar cells and of high temperature superconductors, and at predicting the survivability of detectors used at the LHC at CERN. On the other hand, there are some instances where discrepancies are observed in the application of NIEL, most notably in GaAs semiconductor devices. However, NIEL is still a valuable tool, and can be used to scale damages produced by different particles and in different environments, even though this is not understood at the microscopic level.

Jun, Insoo↗

The LeRC rail accelerators: Test designs and diagnostic techniques

The feasibility of using rail accelerators for various in-space and to-space propulsion applications was investigated. A 1 meter, 24 sq mm bore accelerator was designed with the goal of demonstrating projectile velocities of 15 km/sec using a peak current of 200 kA. A second rail accelerator, 1 meter long with a 156.25 sq mm bore, was designed with clear polycarbonate sidewalls to permit visual observation of the plasma arc. A study of available diagnostic techniques and their application to the rail accelerator is presented. Specific topics of discussion include the use of interferometry and spectroscopy to examine the plasma armature as well as the use of optical sensors to measure rail displacement during acceleration. Standard diagnostics such as current and voltage measurements are also discussed.

Zana, L. M.↗

LeRC rail accelerators - Test designs and diagnostic techniques

The feasibility of using rail accelerators for various in-space and to-space propulsion applications was investigated. A 1 meter, 24 sq mm bore accelerator was designed with the goal of demonstrating projectile velocities of 15 km/sec using a peak current of 200 kA. A second rail accelerator, 1 meter long with a 156.25 sq mm bore, was designed with clear polycarbonate sidewalls to permit visual observation of the plasma arc. A study of available diagnostic techniques and their application to the rail accelerator is presented. Specific topics of discussion include the use of interferometry and spectroscopy to examine the plasma armature as well as the use of optical sensors to measure rail displacement during acceleration. Standard diagnostics such as current and voltage measurements are also discussed. Previously announced in STAR as N83-35053

Zana, L. M.↗

Intensity-Modulated Fiber-Optic Tachometer

Proposed optoelectronic tachometer determines speed of rotation of shaft by measuring fluctuations in intensity of light reflected from notches on shaft. Dual fiber-optic sensor imparts insensitivity to displacements of shaft.

Daniel, James A.↗

Optimal Signal Filtration in Optical Sensors with Natural Squeezing of Vacuum Noises

The structure of optimal receiver is discussed for optical sensor measuring a small displacement of probe mass. Due to nonlinear interaction of the field and the mirror, a reflected wave is in squeezed state (natural squeezing), two quadratures of which are correlated and therefore one can increase signal-to-noise ratio and overcome the SQL. A measurement procedure realizing such correlation processing of two quadratures is clarified. The required combination of quadratures can be produced via mixing of pump field reflected from the mirror with local oscillator phase modulated field in duel-detector homodyne scheme. Such measurement procedure could be useful not only for resonant bar gravitational detector but for laser longbase interferometric detectors as well.

Gusev, A. V.↗

Fiber optic sensors; Proceedings of the Meeting, Cannes, France, November 26, 27, 1985

The conference presents papers on distributed sensors and sensor networks, signal processing and detection techniques, temperature measurements, chemical sensors, and the measurement of pressure, strain, and displacements. Particular attention is given to optical fiber distributed sensors and sensor networks, tactile sensing in robotics using an optical network and Z-plane techniques, and a spontaneous Raman temperature sensor. Other topics include coherence in optical fiber gyroscopes, a high bandwidth two-phase flow void fraction fiber optic sensor, and a fiber-optic dark-field microbend sensor.

Arditty, Herve J.↗

Integrated control and health management. Orbit transfer rocket engine technology program

To insure controllability of the baseline design for a 7500 pound thrust, 10:1 throttleable, dual expanded cycle, Hydrogen-Oxygen, orbit transfer rocket engine, an Integrated Controls and Health Monitoring concept was developed. This included: (1) Dynamic engine simulations using a TUTSIM derived computer code; (2) analysis of various control methods; (3) Failure Modes Analysis to identify critical sensors; (4) Survey of applicable sensors technology; and, (5) Study of Health Monitoring philosophies. The engine design was found to be controllable over the full throttling range by using 13 valves, including an oxygen turbine bypass valve to control mixture ratio, and a hydrogen turbine bypass valve, used in conjunction with the oxygen bypass to control thrust. Classic feedback control methods are proposed along with specific requirements for valves, sensors, and the controller. Expanding on the control system, a Health Monitoring system is proposed including suggested computing methods and the following recommended sensors: (1) Fiber optic and silicon bearing deflectometers; (2) Capacitive shaft displacement sensors; and (3) Hot spot thermocouple arrays. Further work is needed to refine and verify the dynamic simulations and control algorithms, to advance sensor capabilities, and to develop the Health Monitoring computational methods.

Holzmann, Wilfried A.↗