Search NASASearch

SEARCH · Search NASA

Results for “optical fiber”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Optical Fiber H2 Sensor Operating in Harsh Environments of Subsurface H2 Storage Reservoirs

Monitoring hydrogen concentration in the subsurface storage reservoirs is vital to ensure the integrity and safety of the storage facilities. An optical fiber hydrogen sensor consisting of a palladium-based sensing layer and a protective polymer layer was developed and evaluated in simulated subsurface hydrogen storage conditions. The developed optical fiber hydrogen sensor has demonstrated successful sensing performance at ~80 °C, ~1,000 psi, and ~100% RH. In addition, the sensor was exposed to real subsurface microbial samples in the harsh environments to monitor microbially induced changes in hydrogen concentration. The sensor has shown stable H2 sensing responses in the replicated underground hydrogen storage conditions without deterioration or loss of H2 sensitivity in the presence of biological samples.

filter layer

Field validation of dynamic mechanical torque measurements using fiber-optic strain sensors for geared wind turbines

Abstract Accurate knowledge of the mechanical loads of wind turbine gearboxes has become essential in modern, highly loaded gearbox designs, as maintaining or even improving gearbox reliability with increasing torque density demands is proving to be challenging. Unfortunately, the traditional method of measuring dynamic mechanical torque using strain gauges placed on the outer surface of a rotating shaft and transmitting the resulting signal is unsuitable for serial deployment due to technical and economic constraints. An alternative method based on fiber-optic strain sensors placed on the stationary outer surface of the gearbox ring gear has been proposed. Like shaft torsion, the radial deformation of the ring gear is proportionate to the rotor torque. Placing the sensors on a stationary component is a cost-effective alternative for serial implementation because the need for complex and expensive data transfer via wireless transmission or a slip ring is eliminated. In this paper, we present the results of an extensive field experiment conducted to evaluate the torque measurement accuracy of this novel sensing solution installed on the gearbox of a Gamesa G97 2-MW wind turbine at the National Renewable Energy Laboratory’s Flatirons Campus. Torque measurements derived from fiber-optic strain sensors placed on the ring gear of the planetary stage are compared to conventional torque measurements from strain gauges placed on the main shaft. Two different torque estimation data processing methods were evaluated, with the method based on operational deflection shapes providing the most accurate results with an average normalized root mean square error below 0.7% for a load revolution distribution analysis. The effect of operating conditions on the torque estimate was also investigated, and the third planet-passing operational deflection shape was found to be the least sensitive to nontorque load-related effects. The fiber-optic strain sensors’ successful operation during the complete test campaign has demonstrated a robust and accurate solution for fleet-wide enhanced gearbox remaining useful life estimation.

17 WIND ENERGY

Fiber-optic bolometer with low detection limit fabricated using thermal release tape and precise laser heating

Fiber-optic bolometers (FOBs) based on a fiber-tipped silicon Fabry–Perot (FP) interferometric temperature sensor and a gold disk absorber have been shown to be an attractive alternative to conventional resistive bolometers for plasma radiation measurement in fusion devices. Either a high-finesse FP or a low-finesse FP can be used, each with trade-offs between noise performance and fabrication complexity. In this paper, we present an FOB design that overcomes these limitations by combining a low-finesse long silicon FP cavity with a large gold disk absorber to achieve enhanced sensitivity and noise performance without increasing the fabrication complexity and the time constant. We also demonstrated a fabrication method for the sensor head facilitated by thermal release tape and precise laser heating. Our FOB demonstrates a temperature resolution of 0.08 mK, a cooling time constant of 230 ms, and a noise equivalent power density of 0.015 W m −2 . This represents an eightfold improvement over previous high-finesse FOBs and 26-fold improvement over previous low-finesse FOBs with similar demodulation bandwidths and similar cooling time constants.

Fabry–Perot interferometer

Optical Fiber Sensor with a Hydrophobic Filter Layer for Monitoring Hydrogen under Humid Conditions

Real-time and remote monitoring of hydrogen concentration in underground hydrogen storage reservoirs is crucial to maintaining the integrity and safety of the storage facilities. High humidity in the underground deposits interferes with hydrogen sensors, introducing inaccuracy into the hydrogen sensing measurements. A hydrophobic filter layer over a hydrogen sensing layer on an optical fiber hydrogen sensor was devised to minimize the impact of the humidity on the sensor. The hydrogen sensor coated with a hydrophobic filter layer demonstrated a significant improvement in reliable hydrogen sensing under high humidity conditions (99% RH) without severe baseline drift and reduction of transmission intensity. Finally, the optical fiber hydrogen sensor revamped with the filter layer would enable the reliable measurement of hydrogen concentration under the humid conditions expected in subsurface hydrogen storage facilities.

08 HYDROGEN

Accurate Monitoring of an Electrically Energized Casing Source using Fiber Optic Sensing

This report summarizes an investigation of utilizing a Piezoelectric coating on fiber optics to monitor electric fields. The application of interest was monitoring the electric field emitted from a borehole casing being used an an Electromagnetic source in geophysical monitoring. Testing consists of using a water filled vessel with plate electrodes on opposing sides to generate electric fields while lowering a custom designed sensor into the water. The results are compared to what is conventionally available via simulations.

03 NATURAL GAS

Quantum teleportation coexisting with classical communications in optical fiber

The ability for quantum and conventional networks to operate in the same optical fibers would aid the deployment of quantum network technology on a large scale. Quantum teleportation is a fundamental operation in quantum networking, but has yet to be demonstrated in fibers populated with high-power conventional optical signals. Here we report, to the best of our knowledge, the first demonstration of quantum teleportation over fibers carrying conventional telecommunications traffic. Quantum state transfer is achieved over a 30.2-km fiber carrying 400-Gbps C-band classical traffic with a Bell state measurement performed at the fiber’s midpoint. To protect quantum fidelity from spontaneous Raman scattering noise, we use optimal O-band quantum channels, narrow spectro-temporal filtering, and multi-photon coincidence detection. Fidelity is shown to be well maintained with an elevated C-band launch power of 18.7 dBm for the single-channel 400-Gbps signal, which we project could support multiple classical channels totaling many terabits/s aggregate data rates. These results show the feasibility of advanced quantum and classical network applications operating within a unified fiber infrastructure.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC

Local heat transfer measurement in a volumetrically heated TPMS lattice using distributed optical fiber thermal sensing

As additive manufacturing continues to reduce design constraints on heat exchange geometries, methods for high-fidelity local heat transfer measurements in nonconventional channel geometries are critical to their continued development. This study presents a novel method for measuring local heat transfer performance in volumetrically heated lattices using a distributed optical fiber temperature sensor. A diamond-type triply periodic minimal surface (TPMS) lattice, 3D-printed from a conductive polymer, was Joule heated while it was convectively cooled with air. Temperature measurements were taken at the solid–fluid interface across 14 internal locations using a single optical fiber over the Reynolds number range 800–2750. The TPMS lattice achieved up to 312% higher heat transfer coefficients compared to developing flow in a straight tube. A Nusselt number correlation was developed for the diamond TPMS, which showed good agreement with data collected for comparable geometries available in literature. In conclusion, this study presents a robust and new method for experimental measurement of the heat transfer coefficient in complex geometries and helps to understand and quantify the exceptional performance of TPMS heat transfer geometries.

TPMS

Fiber-optic bolometers with high-temperature tolerance and reduced time constants for fusion plasma diagnostics

Fiber-optic bolometers (FOBs) designed for plasma radiation measurement in magnetically confined fusion environments have been previously developed and tested at the DIII-D tokamak. These FOBs utilize a silicon Fabry–Perot interferometer at the fiber tip for temperature measurement and a gold disk as a radiation absorber. This paper presents recent advancements in the development of FOBs with reduced cooling time constants and enhanced temperature tolerance. We also demonstrate high-temperature operation and report findings from irradiation tests. By incorporating a copper sensor holder as a thermal sink and integrating two closely packed sensor heads into a compact design, the cooling time constants were reduced to ∼100 ms in vacuum, while minimizing uncertainties caused by temperature gradients. The FOBs were subjected to heating at 400 °C for five hours, with no observed degradation in noise performance post-heating. High-temperature operation tests were conducted at ∼220 °C using a 404 nm square-wave modulated laser to simulate the plasma radiation. In addition, four FOBs constructed from copper-coated pure-silica fibers were fabricated and underwent irradiation testing, enduring a total γ-radiation dose of 15.2 MGy and a neutron fluence of 1.6 × 10 18 n/cm 2 . As a result, the FOBs maintained their physical integrity and the optical signal shows high visibility throughout the test.

42 ENGINEERING

Pilot-Scale Validation of Distributed Optical Fiber Sensors for Underground Pipeline Monitoring

Monitoring parameters such as hoop strain, pressure, and acoustic vibrations is key to detecting potential leaks, intrusions, or structural issues. Distributed optical fiber sensor (DOFS) systems provide a compelling solution for continuous, real-time monitoring over long distances. This paper details the development and pilot-scale implementation of DOFS systems for underground pipeline monitoring, evolving from a proof-of-concept stage. Multiple custom-designed DOFS interrogator units—such as optical frequency-domain reflectometry (OFDR), Brillouin optical time-domain analysis (BOTDA), and multimodal interferometer-based fiber acoustic sensor systems were tested to measure the key parameters, such as hoop strain, pipe pressure, surrounding soil temperature, and acoustic vibrations. The underground product pipeline’s outer diameter is 30 inches, the wall thickness is 1.28 inches, and 3 feet deep from the surface. The fiber deployment strategies and sensing data acquisition methods for these systems are discussed. The results demonstrate the effectiveness of DOFS in detecting hoop strain, temperature changes, and acoustic vibrations, showcasing their potential for real-time monitoring and enhancing pipeline safety. These findings from pilot-scale testing offer valuable insights into advancing pipeline monitoring technologies and improving the reliability of underground pipeline systems.

fiber optic sensors

Hydrogen Detection via a Low-Cost Prototype Fiber-Optic Sensing System

The developed low-cost prototype sensing system successfully detects hydrogen concentrations across a wide range, demonstrating immediate feasibility for commercial deployment. Utilizing fiber-optic technology, the system delivers stable, reproducible performance from parts-per-million levels up to 100% pure H2 environments. Environmental and chemical cross-sensitivity evaluations confirm robust selectivity against methane and temperature changes, establishing its readiness for near-term commercialization.

fiber-optic H2 sensor

Distributed Fiber Optic Sensing for in-well hydraulic fracture monitoring

This study presents the results from in-well hydraulic fracture monitoring within a horizontal well in an unconventional reservoir utilizing Distributed Fiber Optic Sensing (DFOS). An in-house-developed Brillouin-based Distributed Strain Sensing (DSS) interrogator was deployed to obtain strain measurements, complemented by a commercial Raman-based Distributed Temperature Sensing (DTS) interrogator for temperature measurements and a commercial Rayleigh-based Low-Frequency Distributed Acoustic Sensing (LF-DAS) interrogator for strain-rate measurements. Examined over a ten-day period, the spatio-temporal distribution of temperature-compensated strain obtained from DSS and DTS revealed distinct signatures of the multi-stage hydraulic fracturing process. These signatures were analyzed with respect to fracture width growth and closure, residual strain effects, and fracture conductivity near the wellbore. Fracture widths within the fracture zone were estimated for individual stages. The findings were assessed with LF-DAS measurements for further evaluation. This work integrates DFOS-measured strain, temperature, and strain-rate data for monitoring in-well hydraulic fracturing, with the goal of supporting future studies in interpreting DFOS measurements for improved understanding of hydraulic fracturing in unconventional reservoirs.

58 GEOSCIENCES

Fe-Coated Optical Fiber for Distributed Corrosion Monitoring in Soil and Aqueous Environments

Natural gas pipeline corrosion represents a substantial cost and safety concern during normal operations. The effective and real-time monitoring of corrosion is important to detect and mitigate pipeline risks before corrosion-related catastrophic events happen. Here, we describe the use of iron (Fe) coated optical fiber sensors (OFS) for distributed corrosion monitoring where Fe acts as a corrosion proxy. By using an optical backscattering reflectometer (OBR), corrosion was monitored based on the increase in the backscattered intensity amplitude of the light being passed as Fe underwent corrosion. The Fe-coated OFSs were prepared with a film thickness between 25–225 nanometers (nm) by an electroless plating approach and corroded by a carbon dioxide (CO2)-saturated acidic electrolyte. The corrosion rate (CR) was approximately 2.5 millimeters (mm)/year for Fe with a film thickness of 30 nm and increased with film thickness. Backscattering-based CRs were supported by visible light transmission measurements, which have been previously demonstrated. Additionally, a correlation between the intermittent transmission and residual Fe film thickness during the corrosion of Fe was established. The corrosion was measurable out to > 100 meters (m), which is a significant improvement over our previous work, which showed corrosion sensing at < 10 m. The corrosion sensor was also tested in soil at > 1 foot depth.

corrosion

Fe-Coated Optical Fiber for Distributed Corrosion Monitoring in Soil and Aqueous Environments

Natural gas pipeline corrosion represents a substantial cost and safety concern during normal operations. The effective and real-time monitoring of corrosion is important to detect and mitigate pipeline risks before corrosion-related catastrophic events happen. Here, we describe the use of iron (Fe) coated optical fiber sensors (OFS) for distributed corrosion monitoring where Fe acts as a corrosion proxy. By using an optical backscattering reflectometer (OBR), corrosion was monitored based on the increase in the backscattered intensity amplitude of the light being passed as Fe underwent corrosion. The Fe-coated OFSs were prepared with a film thickness between 25–225 nanometers (nm) by an electroless plating approach and corroded by a carbon dioxide (CO2)-saturated acidic electrolyte. The corrosion rate (CR) was approximately 2.5 millimeters (mm)/year for Fe with a film thickness of 30 nm and increased with film thickness. Backscattering-based CRs were supported by visible light transmission measurements, which have been previously demonstrated. Additionally, a correlation between the intermittent transmission and residual Fe film thickness during the corrosion of Fe was established. The corrosion was measurable out to > 100 meters (m), which is a significant improvement over our previous work, which showed corrosion sensing at < 10 m. The corrosion sensor was also tested in soil at > 1 foot depth.

aqueous environment

Dual-mode fiber-optic refractive-index gas thermometry with primary anchoring and continuous temperature tracking

Extending fiber-optic refractive-index gas thermometry beyond primary-only operation, we report a dual-mode argon-filled Fabry-Perot thermometer in which the same cavity first establishes a primary temperature anchor and then performs continuous secondary-mode tracking. The primary anchor is obtained from two-pressure fringe shifts using a virial-coefficient refractivity model. During secondary operation, pressure cycling is stopped, and temperature is recovered from the monitored fringe wavelength and gas pressure using a model that includes argon refractivity, pressure-induced cavity strain, and fused-silica thermal expansion. From 310 to 1013 K, secondary-mode temperatures agreed with a reference thermocouple with 0.21 K RMSE and 0.47 K maximum error; 45-min natural furnace cooldowns were also tracked from nearby anchors with close agreement. The dual-mode method retains the empirical-calibration-free primary measurement as an in-situ reference while enabling simpler continuous tracking between anchors, addressing a practical limitation of primary-only fiberoptic refractive-index gas thermometry for hightemperature applications.

Syed, Musaddeque [Michigan State University, East

In-line measurements of below-the-surface food deformation during drying with an interference-based optical fiber strain sensor

Real-time measurements of food deformation are important for quality control in drying, yet they pose significant challenges. In this study, we developed an interference-based optical fiber strain sensor to enable in-line, continuous, below-the-surface strain measurements in drying of soft food samples. Compared to a strain resolution of 8 × 10 -4 at zero strain and 7.2 × 10 -3 at 0.20 strain reported in our previously published work, the present study achieves markedly improved resolutions of 1.3 × 10 -4 at zero strain and 7.8 × 10 -4 at 0.25 strain, which strains are the lower and higher boundaries of the dynamic range, respectively. This nearly order-of-magnitude improvement is attributed to the unique interference-based sensing mechanism, no need for calibration to convert optical signals to strain, and the system-design-enabled immunity to fiber-disk misalignments and light source intensity fluctuations. To demonstrate the in-line process monitoring, deformation measurements of fresh banana slices and sugar cookie doughs were carried out in a benchtop oven and an industrial-scale hot-air pilot dryer, respectively. In both dryers, strain measurements were continuously measured during the whole drying process at various depths and radii below the sample surfaces, with the strains up to 25%. Computer vision was used only in the benchtop drying to confirm the faithfulness of the fiber sensor measurements and cannot provide below-the-surface measurements. The measured spatiotemporal deformation allowed us to confirm the shell-hardening effect and to determine the speed and location of large deformation changes in the whole drying process, the latter of which is related to the sample cracking. To the best of the authors’ knowledge, this study is the first to report on an interferometry-based fiber sensor to measure food deformation. This sensor and the sensing mechanism have high potential for real-time process monitoring and control to prevent over-drying or cracking during drying processes.

47 OTHER INSTRUMENTATION

Advancing Temperature Monitoring of the Bottom Anode in a Direct Current Electric Arc Furnace Operations with Distributed Optical Fiber Sensors.

The bottom anode in the Direct Current Electric Arc Furnace (DC EAF) is critical for completing the electrical circuit necessary for sustaining the arc within the furnace. For pin-type bottom anodes, monitoring of the temperature of select pins instrumented with thermocouples is performed to track bottom wear in the EAF and inform the operator when the furnace should be removed from service. Furthermore, this work presents the results from a plant trial using distributed temperature monitoring of bottom anode pins in a 165-ton DC EAF over a two-month service period utilizing two optical fiber sensing techniques: fiber Bragg grating (FBG) and Rayleigh backscattering (RBS). The early detection of temperature anomalies along the length of the anode pin through distributed sensing enhances operational safety, providing a robust alternative to traditional thermocouples.

42 ENGINEERING

Dynamic Heat Flow and Current Distribution Analysis in the Bottom Anode of an Electric Arc Furnace Using Fiber-Optic Sensors

A reliable method for monitoring bottom anode wear during DC Electric Arc Furnace (DC-EAF) operation is of critical importance for safe and efficient steel production. Underestimation of bottom wear poses a serious safety risk that must be avoided, while overestimation of bottom wear also poses challenges, as premature anode replacement is expensive and affects EAF productivity. Previously, we demonstrated that fiber-optic sensors can be successfully deployed to create a spatially distributed temperature map to monitor the health of the anode. The present work explores the heat flow and current density distribution in bottom anode pins to predict bottom wear, steel penetration events, and monitor refractory erosion. Small dynamic variations in pin temperature induced by joule heating during arcing also provide a means to observe local current flows in each pin. When mapped, these measurements provide a real-time view of the non-uniform and dynamic current flow in the bottom anode during EAF operation that can affect bottom wear.

Bottom Anode