Search NASA⌕ Search

SEARCH · Search NASA

Results for “optical local oscillator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

A 2 THz Heterodyne Array Receiver for SOFIA: Summary of Research

We proposed to perform a comprehensive design study of a 16-element heterodyne array receiver for SOFIA. The array was designed to utilize hot-electron bolometers in an efficient, low-cost waveguide mount to achieve low noise performance between approximately 1500 and 2400 GHz. Due to the prevailing physical conditions in the interstellar medium, this frequency range is one of the richest in the Far-Infra Red (FIR) portion of the spectrum. An array designed for this wavelength range will make excellent use of the telescope and the available atmospheric transmission, and will provide a new perspective on stellar, chemical, and galactic evolution in the present as well as past epochs. A few of the most important molecular and atomic species which the instrument will sample are CII, OI, CO, OH, NII, and CH. The system used the most sensitive detectors available in an efficient optical system. The local oscillator was a compact CO2 pumped far-infrared laser currently under development for SOFIA. The backend spectrometer was an array acousto-optic spectrometer (aAOS). The spectrometer utilizes proven hardware and technologies to provide broadband performance (> 1 GHz per AOS channel) and high spectral resolution (1 MHz) with the maximum sensitivity and minimum complexity and cost. The proposed instrument would be the fastest and most sensitive heterodyne receiver ever to operate in the 1.5 - 2.4 THz band. One of the key technologies developed for the proposed instrument is the laser micromachining of waveguide structures. These structures provide both the optical link between the instrument and the telescope (via an array of efficient feedhorns) and the impedance transformation between the detectors and free space. With the assistance of funds provided from this grant, we were able to fabricate and test the world's first laser micromachined feedhorns. The quality of the waveguide structure is far better than that obtainable using any other fabrication technique. The beam parameters are an excellent match to what is expected from theory. The success of this experiment demonstrates the viability of using laser micromachined components in the development of high performance, large format array receivers. We have continued our development efforts and will propose to build a 2nd generation instrument based on the same design concepts.

Walker, Christopher K.↗

A 2 THz Heterodyne Array Receiver for SOFIA

We proposed to perform a comprehensive design study of a 16-element heterodyne array receiver for SOFIA. The array was designed to utilize hot-electron bolometers in an efficient, low-cost waveguide mount to achieve low noise performance between approx. 1500 and 2400 GHz. Due to the prevailing physical conditions in the interstellar medium, this frequency range is one of the richest in the FIR portion of the spectrum. An array designed for this wavelength range will make excellent use of the telescope and the available atmospheric transmission, and will provide a new perspective on stellar, chemical, and galaxy evolution in the present as well as past epochs. A few of the most important molecular and atomic species which the instrument will sample are CII, OI, CO, OH, NII, and CH. The system used the most sensitive detectors available in an efficient optical system. The local oscillator was a compact CO2 pumped far-infrared laser currently under development for SOFIA. The backend spectrometer was an array acousto-optic spectrometer (aAOS). The spectrometer utilizes proven hardware and technologies to provide broadband performance (greater than or equal to 1 GHz per AOS channel) and high spectral resolution (1 MHz) with the maximum sensitivity and minimum complexity and cost. The proposed instrument would be the fastest and most sensitive heterodyne receiver ever to operate in the 1.5 - 2.4 THz band. One of the key technologies developed for the proposed instrument is the laser micromachining of waveguide structures. These structures provide both the optical link between the instrument and the telescope (via an array of efficient feedhorns) and the impedance transformation between the detectors and free space. With the assistance of funds provided from this grant, we were able to fabricate and test the world's first laser micromachined feedhorns. The quality of the waveguide structure is far better than that obtainable using any other fabrication technique. The beam parameters are an excellent match to what is expected from theory. The success of this experiment demonstrates the viability of using laser micromachined components in the development of high performance, large format array receivers. Unfortunately, our instrument proposal was not selected as a first generation SOFIA instrument. However, we have continued our development efforts and will propose to build a 2nd generation instrument based on the same design concepts.

Walker, Christopher K.↗

The U.C. Berkeley Space Sciences Laboratory and Department of Physics Submillimeter Receiver

The UCB submm heterodyne receiver is a complete system for high-resolution astronomical spectroscopy in the 350-micron and 450-micron atmospheric windows. This compact system mounts directly at the Cassegrain focus of large optical and IR telescopes. It consists of a laser local oscillator, open structure mixer, quasi-optical coupling system, a broad-band IF system, and an acoustooptical spectrometer. The local oscillator is a 1-m-long submm laser optically pumped by a CO2 laser. The mixer is a quasi-optical corner-cube antenna structure and Schottky diode. The mixer is currently operated at room temperature, and its performance at 77 K is being evaluated. The system noise temperature is less than 7000 K SSB during observations.

Harris, A. I.↗

Optical design and synthetic analysis of the electron cyclotron emission imaging diagnostic of HL-2M tokamak

The electron cyclotron emission imaging (ECEI) diagnostic is a powerful tool to study the MHD and turbulent transport in magnetically confined fusion plasmas. In this work, the optical system including the local oscillator (LO) coupling and radio frequency (RF) receiving optics, has been designed and analyzed for the HL-2M ECEI diagnostic. The LO optics can illuminate the antenna array and drive the mixer diode to work efficiently, with more than 36% of the beam intensity for the channels which probe the plasma edge relative to those of channels which probe the plasma core. The RF optics aims at guiding the plasma emission signal to the antenna array. To meet different physical requirements, three types of field of view have been achieved for the plasma imaging, with zoom factors of around 1, 1.5 and 2, respectively. The focal surfaces are almost flat, with a maximum off-mapping (defined as the radial distance between the beam waists of the lower-/uppermost antennas and electron cyclotron emission layer) less than 2.5 cm, which can match the electron cyclotron emission layer quite well and suppress the image distortion in the plasma edge region. Furthermore, the impact of possible vibrations and installation error on the focal plane has been evaluated. In addition, the predefined MHD and turbulence perturbations are well reproduced by combining the optical simulation results and synthetic ECEI modeling, which further verifies the good performance of the RF optics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A near-optimum receiver structure for the detection of M-ary optical PPM signals

A class of receivers called conditionally nulling receivers is defined for quantum noise limited optical communications. These receivers have the ability to decide at each moment in time whether or not to coherently combine a predetermined local oscillator field with the received optical field, prior to performing an energy measurement (photodetection) on the combined field. Conditionally nulling receivers are applicable to pulse position modulation and related modulation schemes, which have the property that, at each moment in time, the transmitted signal is in one of only two states, on or off. The local oscillator field which may or may not be added by the receiver is an exact replica of the negative of the received on field; hence, the receiver can exactly null the on signal if the on signal is present and the receiver chooses to use the local field. An ideal conditionally nulling receiver achieves very nearly the same error probability (within a multiplicative factor varying froom 1 to 2.15) as the optimum quantum measurement for quantum noise limited detection of M-ary PPM signals. In contrast, other known receiving methods, such as direct, heterodyne, and homodyne detection, are exponentially suboptimum.

Dolinar, S. J., Jr.↗

Terahertz local oscillator for the Microwave Limb Sounder on the Aura satellite

The Microwave Limb Sounder on the Aura satellite has a radiometer at 2.5 THz to perform global mapping of OH in the atmosphere. The OH radiometer utilizes two Schottky-diode mixers pumped by an optically pumped THz gas laser local oscillator. The laser was first turned on in space on July 22, 2004, and has performed without issue for more than 30 months. The specifications, design, and modeling of this 2.5 THz laser local oscillator are presented here, along with some of the important design validation and test results.

Pickett, Herbert M.↗

A 492 GHz cooled Schottky receiver for radio-astronomy

We developed a 492 GHz cooled GaAs Schottky receiver driven by a solid state local oscillator with a DSB noise temperature of 550 K measured at the telescope. The receiver-bandwidth is approx. equal to 1.0 GHz. Quasi-optical mirrors focus the sky and local oscillator radiation into the mixer. Stability analysis via the Allan variance method shows that the total system including a 1 GHz bandwidth acousto-optical spectrometer built in Cologne allows integration times up to 100 sec per half switching cycle. We successfully used the receiver at the KOSMA 3 m telescope on Gornergrat (3150m) located in the central Swiss Alps near Zermatt during January-February 1992 for observations of the 492 GHz, (CI) (3)P1 to (3)P0 fine structure line in several galactic sources. These observations confirm that Gornergrat is an excellent winter submillimeter site in accordance with previous predictions based on the atmospheric opacity from KOSMA 345 GHz measurements.

Hernichel, J.↗

Excess noise in tunable diode lasers

The method and the apparatus for identifying excess-noise regions in tunable diode lasers are described. These diode lasers exhibit regions of excess noise as their wavelength is tuned. If a tunable diode laser is to be used as a local oscillator in a superheterodyne optical receiver, these excess-noise regions severely degrade the performance of the receiver. Measurement results for several tunable diode lasers are given. These results indicate that excess noise is not necessarily associated with a particular wavelength, and that it is possible to select temperature and injection current such that the most ideal performance is achieved.

Rowland, C. W.↗

Coherent laser radar performance for general atmospheric refractive turbulence

A general theory for the signal-to-noise ratio (SNR) of a coherent detection laser radar is developed using the path-integral formulation (Fresnel approximation), which is valid for any typical path-integrated atmospheric refractive turbulence. The principal effects of refractive turbulence are discussed, and analytical expressions are presented for the case of untruncated Gaussians for the transmitted field, local oscillator field, and transmitter/receiver optics. The physical mechanisms that reduce heterodyne efficiency are identified.

Frehlich, Rod G.↗

The Upper Atmosphere Research Satellite microwave limb sounder instrument

The microwave limb sounder (MLS) on the Upper Atmosphere Research Satellite (UARS) is the first satellite experiment using limb sounding techniques at microwave frequencies. Primary measurement objectives are stratospheric ClO, O3, H2O, temperature, and pressure. Measurements are of thermal emission: all are performed simultaneously and continuously and are not degraded by ice clouds or volcanic aerosols. The instrument has a 1.6-m mechanically scanning antenna system and contains heterodyne radiometers in spectral bands centred near 63, 183, and 205 GHz. The radiometers operate at ambient temperature and use Schottky-diode mixers with local oscillators derived from phase-locked Gunn oscillators. Frequency tripling by varactor multipliers generates the 183- and 205-GHz local oscillators, and quasi-optical techniques inject these into the mixers. Six 15-channel filter banks spectrally resolve stratospheric thermal emission lines and produce an output spectrum every 2 s. Thermal stability is sufficient for 'total power' measurements which do not require fast chopping. Radiometric calibration, consisting of measurements of cold space and an internal target, is performed every 65-s limb scan. Instrument in-orbit performance has been excellent, and all objectives are being met.

Barath, F. T.↗

Spectrally Resolved Synthetic Aperture Imaging Interferometer: Final Report of NASA Innovative Advanced Concepts - Phase 1 Study

The Spectrally Resolved Synthetic-Aperture Imaging Interferometer (SRSAII) is a system proposed to provide high-resolution and high-sensitivity measurements of astronomical objects. SRSAII uses long baseline interferometric methods to achieve the resolution and low-noise, high time-precision detection to achieve the sensitivity. The primary goal of the SRSAII study was to lay out a framework for using new optical physics technologies to directly resolve, both spatially and spectrally, the disk of an exoplanet. In addition to the ambitious goal of directly resolving an exoplanet, the SRSAII team also sought to identify science opportunities achievable with intermediate system configurations which may offer resolution significantly higher than the current state of the art, but insufficient for direct resolution of an exoplanetary disk. An operational SRSAII system can function with essentially arbitrarily large baselines, achieving correspondingly high angular resolution. The primary limitation occurs in the system sensitivity, which became the major technical focus for study. In this report, we compare the predicted performance (sensitivity in SNR (Signal-to-Noise Ratio) along with angular resolution) of three interferometric techniques: direct detection (also known as homodyne interferometry), multi-channel intensity interferometry (using the Hanbury Brown and Twiss effect), and multi-channel heterodyne interferometry (using an optical frequency comb as a local oscillator). Additionally, quantum-assisted interferometry is also explored as a prospective enhancement of established methods. This report presents a survey of the technologies that enable the SRSAII techniques - optical frequency combs, single photon detectors, and photonic integrated circuits. These technologies are the basis of methods critical to SRSAII's success: precision timing, length and frequency metrology, sensitive photodetection, fine-scale wavelength filtering, and dense multi-channel operation. Lastly, we give some notional performance metrics and propose some possible experimental observations.

High Resolultion↗

Submillimeter local oscillators for heterodyne spectroscopy

The major technological innovations in continuous wave (CW) submillimeter sources which are specifically suitable for application as local oscillators in heterodyne systems are reviewed. A description of the various sources is given which underscores the general principles and operating features for each type of device. Particular emphasis is placed on CW optically pumped lasers, which have had a dramatic impact as widely available sources of narrow linewidth coherent radiation. The state-of-the-art is summarized for these lasers and performance data are presented for several local oscillator packages. Optically pumped lasers are then compared and contrasted with other competing sources such as backward wave oscillators, IMPATT diodes, and Josephson junctions. By comparing their advantages and limitations for use as local oscillators, the potential applications of these different sources are projected. The prospects for increased tunability, reliability, and scalability are briefly considered, and several novel techniques for generating partially tunable radiation using Schottky diode mixers or CW Raman lasers are highlighted.

Danielewicz, E. J., Jr.↗

A theoretical and experimental study of the noise behavior of subharmonically injection locked local oscillators

A method for the noise characterization of optically controlled subharmonically injection-locked oscillators is presented. Based on a nonlinear model of synchronized oscillators, this method is used to formulate a general expression for phase noise calculation, so that FM noise degradation of a subharmonically synchronized LO at large-signal levels can be predicted easily and accurately. Experimental results of FM noise measurement of an oscillator confirmed the accuracy of the analysis.

Zhang, Xiangdong↗

A dual-frequency 183/380 GHz receiver for airborne applications

A complete dual-frequency cryogenic heterodyne receiver operating at 183 and 380 GHz is described. The cooled mixers are whisker-contacted GaAs Schottky diodes mounted in reduced-height fundamental-mode waveguide. The local oscillators are Gunn-oscillator-driven multipliers using GaAs varactor diodes as the harmonic generators. Quasi-optical techniques are used extensively for coupling the remote and local oscillator signals into the mixers. The overall system double side-band (DSB) noise temperature is 320 K for the 183-GHz receiver and 650 K for the 380 GHz receiver.

Batelaan, Paul D.↗

Instrumentation for submillimeter spectroscopy; Proceedings of the Meeting, Cannes, France, December 5, 6, 1985

The design and performance of spectroscopic instruments for submm-wave astronomy are discussed in reviews and reports. Topics examined include superconducting mixers, Schottky-diode mixers, local oscillators, antennas and quasi-optical components, spectrometry, and systems aspects. Special emphasis is given to candidate components for the 8-m heterodyne FIR and Submm Space Telescope being developed by ESA.

Kollberg, Eric↗

Truncated non-linear interferometer-based sensor system

A truncated non-linear interferometer-based sensor system includes an input that receives an optical beam and a non-linear amplifier that generates a probe beam and a conjugate beam from the optical beam. The system's local oscillators are related to the probe beam and the conjugate beam. The system includes a sensor that transduces an input with the probe beam and the conjugate beam. The transduction detects changes in the phase of each of the probe beam and the conjugate beam. The system's phase sensitive detectors detect phase modulations between the respective local oscillators, the probe beam, and the conjugate beam and outputs phase signals based on detected phase modulations. The system measures phase signals indicative of the sensor's input resulting from a sum or difference of the phase signals. The measurement exhibits a quantum noise reduction in an intensity difference, a phase sum, or an amplitude difference quadrature.

47 OTHER INSTRUMENTATION↗

An All-Optical Microwave Mixer with 8db RF Gain

An all-optical microwave mixer with an 8dB RF gain is demonstrated by using a semiconductor optical amplifier (SOA). 6GHz RF signal on a 1312 nm optical carrier is up-converted and down-converted to 1GHZ and 11 GHz by a 5GHz local oscillation (LO) signal on a 1320 nm optical carrier. Such a carrier could readily extend to millimeter wave range.

microwave mixer fiberoptics fiber optic transmissi↗