Search NASA⌕ Search

SEARCH · Search NASA

Results for “optical sources”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Spectroscopic classification, variability, and SED of the Fermi -detected CSS 3C 286: the radio-loudest NLS1 galaxy?

ABSTRACT 3C 286 is a well-known calibrator source in radio astronomy. It is also one of very few compact steep-spectrum (CSS) sources detected in γ-rays. Here, we perform a detailed spectroscopic and variability analysis and present the first quasi-simultaneous optical to X-ray spectral energy distribution (SED) in order to reveal physical mechanisms that dominate its emission at different wavelengths, and arrive at a reliable optical source classification. The first main result of our study reveals several pitfalls when applying simple broad- or narrow-line Seyfert 1 (BLS1 or NLS1) classification criteria that only look at the [O iii]–Hβ complex. [O iii] and Hβ can be dominated by the same outflow components, in which case full width at half-maximum (Hβ) is no reliable classification criterion, and extinction by intrinsic or intervening material can make the highest velocity Hβ component undetectable. After careful combination of all information from ultraviolet (UV)–optical spectra along with multiwavelength data, we confirm that 3C 286 can be classified as NLS1 galaxy, with line properties and supermassive black hole mass (of order 108 M⊙ and accreting near the Eddington limit) close to the BLS1 regime, making it an important borderline object. The quasi-simultaneous SED taken with Swift shows a sharp rise in the optical–UV, implying the presence of a strong accretion-disc component with extreme UV excess, consistent with emission-line diagnostics. Finally, we report the discovery of X-ray variability of 3C 286, plausibly dominated by jet emission, and variable by at least a factor of ∼4. This result suggests to exercise caution when using 3C 286 as radio calibrator in high-resolution radio very long baseline interferometry observations.

Yao, Su↗

Visualizing Electric and Magnetic Field Coupling in Au-Nanorod Trimer Structures via Stimulated Electron Energy Gain and Cathodoluminescence Spectroscopy: Implications for Meta-Atom Imaging

In this work, trimer meta-atoms composed of three gold rods in an equilateral triangular geometry were fabricated, and their near-field plasmonic responses were characterized via electron energy loss (EEL), cathodoluminescence (CL), and stimulated electron energy loss/gain (sEEL/sEEG) spectroscopy. The trimer structure hybridizes into a low-energy mode with all three rods coupling in-phase, which produces a circulating current and thus a magnetic field. The next highest-energy mode consists of two rods coupling out-of-phase and produces a net electric dipole. We investigate the near fields of hybridized magnetic and electric modes via EEL and CL and correlate their spectral characteristics and intensity maps. Then, by changing the length of the trimer rods, we tune the magnetic and electric modes to our laser energy and characterize the excited state via sEEL/sEEG spectroscopy. Exploration of the tilt dependence, relative to the optical source, of the two modes reveals that the electric mode sEEG intensity increases more than the expected sin 2 (θ) dependence of the optical electric field coupling (see the Supporting Information for a detailed description). After correcting for the tail of the close-proximity electric mode, we demonstrate sEEG via coupling of the magnetic component of the optical field to the magnetic meta-atoms, which has the expected cos 2 (θ) tilt dependence. This realization opens the possibility to explore the nanoscale excited-state near-field imaging of other magnetic meta-atom structures.

36 MATERIALS SCIENCE↗

Waveguides for neurostimulation in the cochlea

Introduction Optical stimulation has been suggested for neural stimulation to improve cochlear implants. Light allows for more spatially selective activation of neuron populations than electrical current, offering more independent frequency bands along the spiral ganglion. These bands are available to encode acoustic information with anticipated better frequency resolution, improving cochlear implant user performance in noisy listening environments, tonal languages, and music perception. Methods Optical cochlear implants (oCIs) can deliver light either directly via small emitters within the cochlea or via waveguides from external optical sources. We investigated three waveguide designs made from OrmoComp ® , a polymer that cures through ultraviolet (UV) radiation. Waveguides were fabricated via injection molding and coated using dip-coating or thermal reflow, or through aspiration of OrmoComp ® into polyimide tubing that served as the cladding of the waveguide. The choice of fabrication technique directly determined the waveguides' total diameter: thermal reflow yielded ≈940 μm, dip-coating produced ≈306 μm, and aspiration resulted in ≈132 μm core diameter waveguides. Given the human cochlea's small size, we focused on analyzing the 306-μm and 132-μm waveguides, evaluating their optical performance (propagation and bending losses) and mechanical properties (bending stiffness and insertion forces). Furthermore, we evaluated some of these designs in in-vivo guinea pigs experiments. Results For the 100-μm core diameter waveguides, the propagation losses were 12.34 ± 1.26, 1.18 ± 0.88, 1.49 ± 0.58, and 3.43 ± 0.68 dB/cm at 534, 1,375, 1,460, and 1,550 nm, respectively. The respective bending losses at a 2 mm radius of curvature were 5.50 ± 1.32, 0.56 ± 0.26, 0.79 ± 0.18, and 0.64 ± 0.23 dB, and at 1 mm 8.54 ± 1.30, 2.05 ± 0.84, 2.11 ± 0.50, and 1.44 ± 0.37 dB. The bending stiffness of a 1 mm segment of the 100-μm-diameter waveguides was 18.9 ± 2.2 N/m. Insertion forces for the 100-μm-diameter waveguides into an acrylic human-size scala tympani model were < 25 mN. For the waveguides with 306 and 940 μm total diameter, the propagation losses ranged between 0.43 and 2.40 dB/cm at 534, 680, 1,375, and 1,550 nm, between 2.19 and 3.78 dB/cm at 450 and 1,460 nm. Bending losses for 360 degrees at 1,375 nm were 5.0, 2.4, and 0.46 for a bending radius of 2.5-, 3-, and 4-mm. Discussion Our study demonstrated that the polymer OrmoComp ® is suitable for fabricating waveguides to transmit near-infrared radiation. In-vivo experiments showed optically evoked auditory responses originating from optical stimulation in the guinea pigs' first cochlear turn while radiation was delivered. Incoming experiments will focus on evaluating long-term performance of these waveguides in guinea pigs and cats. This study will be designed to provide insights into the waveguides' performance and biocompatibility over extended periods, essential for their potential clinical application in future oCIs.

Kim, Matthew↗

Dynamically controlled random lasing with colloidal titanium carbide MXene

Control of lasing properties through tailorable and dynamically tunable materials and reconfigurable compositions can augment the performance of random lasers for a wide range of applications. Here, a colloid of randomly dispersed weakly scattering single-layer titanium carbide (Ti 3 C 2 T x ) MXene flakes embedded within rhodamine 101 gain medium is experimentally shown to provide feedback for random lasing. Additionally, in contrast to previously reported random laser systems where the optical properties of scatterers are static, the relative permittivity of Ti 3 C 2 T x MXene flakes can be varied under optical pumping due to the saturable absorption properties. Numerical simulations indicate that the observed nonlinear response of Ti 3 C 2 T x MXene flakes enables dynamically tunable random lasing. Thus, pumping the Ti 3 C 2 T x MXene flakes with a second optical source decreases the gain threshold required to obtain random lasing. Also, using numerical simulations, it is shown that the control over the intensity of the second pump enables tuning the field distribution of the random lasing modes. Considering the diversity of the MXenes family, the proposed MXene colloidal metamaterial design opens up a new avenue to advanced control of lasing properties for photonic applications.

36 MATERIALS SCIENCE↗

Near-field terahertz nonlinear optics with blue light

Abstract The coupling of terahertz optical techniques to scattering-type scanning near-field microscopy (s-SNOM) has recently emerged as a valuable new paradigm for probing the properties of semiconductors and other materials on the nanoscale. Researchers have demonstrated a family of related techniques, including terahertz nanoscopy (elastic scattering, based on linear optics), time-resolved methods, and nanoscale terahertz emission spectroscopy. However, as with nearly all examples of s-SNOM since the technique’s inception in the mid-1990s, the wavelength of the optical source coupled to the near-field tip is long, usually at energies of 2.5 eV or less. Challenges in coupling of shorter wavelengths (i.e., blue light) to the nanotip has greatly inhibited the study of nanoscale phenomena in wide bandgap materials such as Si and GaN. Here, we describe the first experimental demonstration of s-SNOM using blue light. With femtosecond pulses at 410 nm, we generate terahertz pulses directly from bulk silicon, spatially resolved with nanoscale resolution, and show that these signals provide spectroscopic information that cannot be obtained using near-infrared excitation. We develop a new theoretical framework to account for this nonlinear interaction, which enables accurate extraction of material parameters. This work establishes a new realm of possibilities for the study of technologically relevant wide-bandgap materials using s-SNOM methods.

47 OTHER INSTRUMENTATION↗

Probing and Tuning Strain‐Localized Exciton Emission in 2D Material Bubbles at Room Temperature

In monolayer transition metal dichalcogenides bubbles-nanoscale deformations typically exhibiting a dome-like shape-Excitons are confined by the strain effect, which exhibits extraordinary emission properties, such as single photon generation, enhanced light emission, and spectrally tunable excitonic states. While the strain profiles of these bubbles are extensively studied, this work provides an approach 1) to directly visualize the associated exciton properties in bubbles formed in WSe2 monolayer, revealing an intrinsic emission wavelength shift of ≈40 nm, and 2) actively modify local strain, enabling further exciton emission tuning over a range of 50 nm. These are achieved by emission mapping and nanoindentation using a dielectric near-field probe, which enables the detection of local emission spectra and emission lifetimes within individual bubbles. Statistical analysis of 67 bubbles uncovers an emission wavelength distribution centered around 780 nm. Furthermore, saturation behavior in the power-dependent studies and the associated lifetime change reveal the localized nature of the strain-induced states. These findings provide direct insights into the strain-localized emission dynamics in bubbles and establish a robust framework for non-destructive, reversible, and predictable nanoscale emission control, presenting a potential avenue for developing next-generation tunable quantum optical sources.

2D materials bubbles↗

CeNTREX: a new search for time-reversal symmetry violation in the 205 Tl nucleus

The Cold molecule Nuclear Time-Reversal EXperiment (CeNTREX) is a new effort aiming for a significant increase in sensitivity over the best present upper bounds on the strength of hadronic time reversal (T) violating fundamental interactions. The experimental signature will be shifts in nuclear magnetic resonance frequencies of 205 Tl in electrically-polarized thallium fluoride (TlF) molecules. Here we describe the motivation for studying these T-violating interactions and for using TlF to do so. To achieve higher sensitivity than earlier searches for T-violation in TlF, CeNTREX uses a cryogenic molecular beam source, optical state preparation and detection, and modern methods of coherent quantum state manipulation. Details of the measurement scheme and the current state of the apparatus are presented, with quantitative measurements of the TlF beam. Lastly, the estimated sensitivity and methods to control systematic errors are discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The development and use of metal-based probes for X-ray fluorescence microscopy

Abstract X-ray fluorescence microscopy (XFM) has become a widely used technique for imaging the concentration and distribution of metal ions in cells and tissues. Recent advances in synchrotron sources, optics, and detectors have improved the spatial resolution of the technique to <10 nm with attogram detection sensitivity. However, to make XFM most beneficial for bioimaging—especially at the nanoscale—the metal ion distribution must be visualized within the subcellular context of the cell. Over the years, a number of approaches have been taken to develop X-ray-sensitive tags that permit the visualization of specific organelles or proteins using XFM. In this review, we examine the types of X-ray fluorophore used, including nanomaterials and metal ions, and the approaches used to incorporate the metal into their target binding site via antibodies, genetically encoded metal-binding peptides, affinity labeling, or cell-specific peptides. We evaluate their advantages and disadvantages, review the scientific findings, and discuss the needs for future development.

36 MATERIALS SCIENCE↗

Control Design for Inhomogeneous-Broadening Compensation in Single-Photon Transducers

We report a transducer of single photons between microwave and optical frequencies can be used to realize quantum communication over optical fiber links between distant superconducting quantum computers. A promising scalable approach to constructing such a transducer is to use ensembles of quantum emitters interacting simultaneously with electromagnetic fields at optical and microwave frequencies. However, inhomogeneous broadening in the transition frequencies of the emitters can be detrimental to this collective action. In this paper, we utilize a gradient-based optimization strategy to design the temporal shape of the laser field driving the transduction system to mitigate the effects of inhomogeneous broadening. We study the improvement of transduction efficiencies as a function of inhomogeneous broadening in different single-emitter cooperativity regimes and correlate it with a restoration of super-radiance effects in the emitter ensembles. Furthermore, to assess the optimality of our pulse designs, we provide certifiable bounds on the design problem and compare them to the achieved performance.

74 ATOMIC AND MOLECULAR PHYSICS↗

Room-temperature high-purity single-photon emission from carbon-doped boron nitride thin films

Hexagonal boron nitride (h-BN) has emerged as a promising platform for generating room temperature single photons exhibiting high brightness and spin-photon entanglement. However, improving emitter purity, stability, and scalability remains a challenge for quantum technologies. Here, we demonstrate highly pure and stable single-photon emitters (SPEs) in h-BN by directly growing carbon-doped, centimeter-scale h-BN thin films using the pulsed laser deposition (PLD) method. These SPEs exhibit room temperature operation with polarized emission, achieving a g (2) (0) value of 0.015, which is among the lowest reported for room temperature SPEs and the lowest achieved for h-BN SPEs. It also exhibits high brightness (~0.5 million counts per second), remarkable stability during continuous operation (>15 min), and a Debye-Waller factor of 45%. First-principles calculations reveal unique carbon defects responsible for these properties, enabled by PLD’s low-temperature synthesis and in situ doping. Our results demonstrate an effective method for large-scale production of high-purity, stable SPEs in h-BN, enabling robust quantum optical sources for various quantum applications.

36 MATERIALS SCIENCE↗

Quantum Random Number Generator (QRNG)

The Los Alamos QRNG is a hardware-based high-performance Random Number Generator capable of generating 200 Mbit/s or more of true random numbers. The device harvests entropy from fluctuations in an optical source that arise from quantum mechanical properties of light. These quantum effects are irreducibly random; the resulting numbers are unpredictable and beyond the influence of any adversary. Qrypt, Inc., launched in 2017, has amassed multiple quantum entropy sources to create high-quality random keys at scale. The company is engaging with Los Alamos through license and a Cooperative Research and Development Agreement to facilitate the transition of QRNG technology and deploy the technology into the marketplace.

97 MATHEMATICS AND COMPUTING↗

Quantum Random Number Generator (QRNG)

The Los Alamos Quantum Random Number Generator (QRNG) is a hardware-based, high-performance Random Number Generator capable of generating 200 Mbit/s or more of true random numbers. Like flipping a coin, it is very much random and essential for information security like encrypting data on the internet, checking email, or purchasing something from an online vendor. The device harvests entropy from fluctuations in an optical source that arise from quantum mechanical properties of light. Qrypt, Inc., a company launched in 2017, began making strategic investments and developing partnerships to advance cutting-edge quantum hardware solutions. One of those key investments was licensing QRNG from Los Alamos and subsequently collaborating with advanced quantum materials and technology researcher Dr. Raymond Newell to create high-quality random keys at scale.

97 MATHEMATICS AND COMPUTING↗

KIPM Detector Characterization in QUIET

Kinetic Inductance Phonon‑Mediated (KIPM) detectors are superconducting microwave resonators on silicon that sense bursts of energy through tiny shifts in their resonance. In this work, we installed new devices in the QUIET facility's cryogenic test setup and used a network analyzer to drive them across a range of power levels. At each setting, we measured the transmitted signal and fit it to a simple notch‑filter model, allowing us to extract key performance metrics. And despite the increased noise at low power, our model consistently captured the resonance behavior. We observed that the resonant frequency stayed stable across most powers, the device s internal quality factor improved with stronger signals, and its coupling strength peaked mid‑range before leveling off. Overall, these findings confirm the detector s performance, laying groundwork for future work on energy calibration with pulsed optical sources.

Savitala, Akash [Washington U., Seattle; Fermilab]↗

Apparatus and method to measure semiconductor optical absorption using microwave charge sensing

A time-resolved microwave reflectance apparatus comprises a pulsed or modulated optical source that irradiates a semiconductor sample with an excitation pump beam, a microwave oscillator that irradiates the sample with a continuous beam of microwaves, and a microwave detector that detects the microwaves reflected by the sample. Therefore, charge detection, rather than conventional absorption measurements (that detect the loss of photons), can be used to extract the absorption coefficient and band edge of a semiconductor material.

Shaner, Eric A.↗

System and method for grain refinement and general control of grain morphology in laser additive manufacturing

The present disclosure relates to a system for forming a material layer that may make use of an optical light source for generating an optical beam, and a beam shaping subsystem configured to shape the optical beam to generate a complex beam intensity profile. The complex shaped beam may be used to selectively melt at least portions of a bed of powder particles residing on a substrate during formation of the material layer, as the optical light source is moved. A computer may be used to control the optical light source. The complex beam intensity profile enables control over the microstructure of grains formed during melting of the powder particles as the material layer is formed.

Roehling, Tien↗

6 nm super-resolution optical transmission and scattering spectroscopic imaging of carbon nanotubes using a nanometer-scale white light source

Abstract Optical transmission and scattering spectroscopic microscopy at the visible and adjacent wavelengths denote one of the most informative and inclusive characterization methods in material research. Unfortunately, restricted by the diffraction limit of light, it cannot resolve the nanoscale variation in light absorption and scattering, diagnostics of the local inhomogeneity in material structure and properties. Moreover, a large quantity of nanomaterials has anisotropic optical properties that are appealing yet hard to characterize through conventional optical methods. There is an increasing demand to extend the optical hyperspectral imaging into the nanometer length scale. In this work, we report a super-resolution hyperspectral imaging technique that uses a nanoscale white light source generated by superfocusing the light from a tungsten-halogen lamp to simultaneously obtain optical transmission and scattering spectroscopic images. A 6-nm spatial resolution in the visible to near-infrared wavelength regime (415–980 nm) is demonstrated on an individual single-walled carbon nanotube (SW-CNT). Both the longitudinal and transverse optical electronic transitions are measured, and the SW-CNT chiral indices can be identified. The band structure modulation in a SW-CNT through strain engineering is mapped.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Accurate Monitoring of an Electrically Energized Casing Source using Fiber Optic Sensing

This report summarizes an investigation of utilizing a Piezoelectric coating on fiber optics to monitor electric fields. The application of interest was monitoring the electric field emitted from a borehole casing being used an an Electromagnetic source in geophysical monitoring. Testing consists of using a water filled vessel with plate electrodes on opposing sides to generate electric fields while lowering a custom designed sensor into the water. The results are compared to what is conventionally available via simulations.

03 NATURAL GAS↗

Viricidal and bactericidal exciplex barrier-discharge lamps

A brief review is presented of investigations performed in 2002 – 2020 on ultraviolet inactivation of bacteria, vital cells, and viruses by using excilamps. The excilamp models that have been developed at the Institute of High-Current Electronics, SB RAS are briefly described. Scientific data acquired by now show that excilamps on KrCl{sup *}, KrBr{sup *}, and XeBr{sup *} molecules are an alternative to low-pressure mercury lamps with respect to optical parameters. These sources of optical radiation exhibit a bactericidal effect, and emission of KrCl and KrBr excilamps demonstrates viricidal action. The latter is actual due to expansion of coronavirus disease. (paper)

60 APPLIED LIFE SCIENCES↗