Search NASA⌕ Search

SEARCH · Search NASA

Results for “optical spectrometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Temperature and Pressure Instrumentation for LYNM PE1 Chemical Explosive Testing

Underground chemical explosive testing has been conducted at the Nevada National Security Site under the Physics Experiment 1 (PE1) to validate explosive computer modeling and, ultimately, improve the accuracy of subsurface explosive detection. This SAND Report describes the dynamic temperature and pressure measurements within the chamber induced by the chemical explosive for the first of three experiments, PE1-A. The report details the instrumentation used for the experiment, the emplacement of the hardware, and the measured results. Dynamic temperature measurements were accomplished with the use of optical spectrometers and dynamic pressure was measured with a series of high-rated pressure transducers. This report includes details of the design and results of four cavity sensor systems used to measure early-time temperature, early-time pressure, late-time temperature, and late time pressure. The outcomes of PE1-A were used to inform the design of the remaining PE1 series experiments, PE1-B and PE1-DL.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

NCSU Flux Tower Data

NCSU Flux Tower Data Level b1: QC checks applied to measurements Data Format: CSV Description: See "instrument descripotion Site: Houston, TX; Tracking Aerosol Convection interactions ExpeRiment (HOU) Location: Houston, TX; AMF1 (main site for TRACER) Facility Code: M1 Category: Aerosol Properties Data Type: PI Data Source Instrument/Data: Sonic Anemometer, 3 Condensation Particle Counters, 1 SP2, 1 POPS Start Date: 2022-06-01 End Date: 2022-9-26 Contact PI: Markus Petters (mdpetter@ncsu.edu) Funding Source: DOE ASR award US Department of Energy, Office of Science, Biological and Environment Research (grant no. DE-SC 0021074) Instrument description The NCSU flux tower was located next to the AMF sampling pad. The flux tower consisted of a 10 m telescoping tower. Mounted at the top of the tower was a sonic anemometer (RM Young 8000) and a Krypton Hygrometer. A sample line (¼” conductive tubing) and communication line was laid to a trailer located underneath and slightly adjacent to the tower. The sample line brought aerosol inside the trailer at 4.5 L min-1, where it was distributed between 3 CPCs (TSI 3776c, Dc ~ 2.5 nm, TSI 3771, Dc ~10nm, and TSI 3772, Dc ~40 nm) with different size cuts. Also sampling was a printed particle optical spectrometer (POPS) and a single particle soot photometer (SP2). Please contact mdpetter@ncsu.edu for further information.

54 ENVIRONMENTAL SCIENCES↗

NCSU Black Carbon (SP2) Data

NCSU SP2 Data Data Level b1: QC checks applied to measurements Data Format: CSV Description: See "instrument description Site: Houston, TX; Tracking Aerosol Convection interactions ExpeRiment (HOU) Location: Houston, TX; AMF1 (main site for TRACER) Facility Code: M1 Category: Aerosol Properties Data Type: PI Data Source Instrument/Data: Single Particle Soot Photometer (SP2) Start Date: 2022-06-01 End Date: 2022-09-27 Contact PI: Markus Petters (mdpetter@ncsu.edu) Funding Source: DOE ASR award US Department of Energy, Office of Science, Biological and Environment Research (grant no. DE-SC 0021074) Instrument description The SP2 was located in the temperature-controlled trailer adjacent to the NCSU Flux Tower to observe refractory black carbon (rBC) number concentration and mixing states of black carbon. The sample line brought aerosol inside the trailer at 4.5 L min-1, where it was distributed between 3 CPCs (TSI 3776c, Dc ~ 2.5 nm, TSI 3771, Dc ~10nm, and TSI 3772, Dc ~40 nm) with different size cuts, a printed particle optical spectrometer (POPS), and SP2. Please contact mdpetter@ncsu.edu for further information.

54 ENVIRONMENTAL SCIENCES↗

Metal-Organic Framework-based Luminescent Sensors for Rare Earth Elements

Rare earth elements (REEs) are crucial for many applications and are particularly important in wind power and electric vehicle technologies, spurring projected demand increases for REEs in coming decades. However, the REE supply is restricted by a monopolistic global marketplace, tedious and costly processing steps for REE production, and environmental hazards associated with mining and processing. Coal and coal-utilization byproducts have emerged as potential domestic sources for REEs, however REE production from these sources is currently hindered by slow and expensive characterization techniques. Here, we demonstrate that metal-organic framework (MOF)-based sensitizers can effectively serve as luminescent sensors capable of rapidly detecting and distinguishing part-per-billion concentration levels of emissive REEs, including terbium, europium, dysprosium, samarium, neodymium, and ytterbium. Importantly, we demonstrate that the MOF structure plays a significant role in tuning the selectivity of the MOF for REEs in acidic environments, an essential step towards deployment in various REE-rich process streams. As a proof-of-concept, we demonstrate sensitive and reversible detection of REEs using a portable fiber-optic spectrometer

Crawford, Scott↗

Compact folded metasurface spectrometer

Compact optical devices such as spectrometers are realized with metasurfaces within a dielectric medium confined by reflective surfaces. The metasurfaces control the phase profiles of the reflected electromagnetic waves within the device. In a compact spectrometer, the metasurfaces within the device separate the electromagnetic waves in different wavelengths. The metasurfaces are designed according to their phase profile by varying the size of the array of scatterers.

Faraji-Dana, MohammadSadegh↗

Fourier domain dynamic correction method for complex optical fringes in laser spectrometers

A method is provided for Fourier domain dynamic correction of optical fringes in a laser spectrometer. The method includes Fourier transforming a background spectrum contaminated with the optical fringes to obtain baseline fringes in a frequency domain. The method includes partitioning the baseline fringes in the frequency domain to obtain partitioned baseline fringes. The method includes reconstructing the partitioned baseline fringes as separate spectra. The method includes constructing a fitting model to approximate the background spectrum by assigning a first and a second free parameter to each of partitioned baseline fringe components to respectively allow for drift and amplitude adjustments during a fitting of the fitting model. The method includes applying the fitting model to a newly acquired spectrum to provide an interpretation of the newly acquired spectrum having a reduced influence of spectral contamination on concentration retrieval.

Teng, Cheyenne↗

Particle Flux Measurements during TRACER (TRACER PFM) (Field Campaign Report)

The purpose of this campaign was to deploy an instrument payload collocated with a suite of in situ and remote-sensing aerosol instruments at the urban site at the La Porte, Texas Municipal Airport during the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Tracking Aerosol Convection Interactions Experiment (TRACER) in Houston, Texas. The payload was designed to characterize the physicochemical properties, mixing state, and size-resolved vertical fluxes of aerosols. Deployed aerosol instruments associated with the flux measurements included three condensation particle counters (CPCs) with different lower cutoff diameters ( D > 2.5 nm, D > 10 nm, and D > 40 nm), a single-particle soot photometer (SP2) measuring refractory black carbon, and a portable optical particle spectrometer (POPS) measuring the optical size distribution (~180 nm < D < ~5000 nm). A 10-m flux tower hosted a sonic anemometer (SONIC) for vertical velocity measurements. In addition, a humidified tandem differential mobility analyzer (HTDMA) was deployed to measure the growth factors and hygroscopicity parameter of 15-50 nm-sized particles in order to constrain the composition of compounds responsible for modal aerosol growth during new particle formation/growth events. Finally, a radial differential mobility analyzer (RDMA) was deployed to extend the size distribution measurement to 5 nm.

54 ENVIRONMENTAL SCIENCES↗

Experimental Report: Multi-Instrument Comparison of AAF Size Distribution Instruments

Aerosols are particles suspended in the atmosphere, ranging in size from nanometers to micrometers. Their size distribution affects key atmospheric processes, including nucleation, coagulation, scavenging, activation, and radiative properties (Seinfeld and Pandis 2016). Aerosol size distribution is a critical parameter in atmospheric science, influencing processes such as cloud formation and radiative forcing. Accurate representation of aerosol size distributions is essential for understanding their impact on climate, air quality, and human health. However, aerosol size and composition vary significantly across time and space due to meteorological conditions and natural or anthropogenic sources. (Wu and Boor 2021). Various instruments are used to measure aerosol size distributions, each with distinct principles, advantages, and limitations. This report begins with an in-depth overview of aerosol size-distribution comparison studies, focusing on the passive cavity aerosol spectrometer probe (PCASP), portable optical particle spectrometer (POPS), ultra-high-sensitivity aerosol spectrometer (UHSAS), aerodynamic particle sizer (APS), and scanning mobility particle sizer (SMPS). All of these instruments are used by the U.S. Department of Energy Atmospheric Radiation Measurement (ARM) Aerial Facility (AAF), which commissioned this comparison and report. The report evaluates the strengths and weaknesses of these instruments, highlights their applications, and discusses efforts to merge data from multiple instruments for comprehensive analysis.

54 ENVIRONMENTAL SCIENCES↗

Undersizing of aged African biomass burning aerosol by an ultra-high-sensitivity aerosol spectrometer

The ultra-high-sensitivity aerosol spectrometer (UHSAS) differs from most other optical particle spectrometers by using a high-power infrared (IR) laser to detect small particles and reduce the sizing ambiguity due to the non-monotonicity of scattering with particle size. During the NASA ORACLES project (ObseRvations of Aerosols above CLouds and their intEractionS) over the southeast Atlantic Ocean, the UHSAS clearly undersized particles in the biomass burning plume extending from southern Africa. Since the horizontal and vertical extent of the plume was vast, the NASA P-3B research aircraft often flew through a fairly uniform biomass burning plume for periods exceeding 30 min, sufficient time to explore the details of the UHSAS response by selecting single particle sizes with a differential mobility analyzer (DMA) and passing them to the UHSAS. This was essentially an in-flight calibration of the UHSAS using the particles of interest. Two modes of responses appeared. Most particles were undersized by moderate amounts, ranging from not at all for 70 nm aerosols to 15 % for 280 nm particles. Mie scattering calculations show that composition-dependent refractive index of the particles cannot explain the pattern. Heating of brown carbon or tarballs in the beam causing evaporation and shrinking of the particles is the most plausible explanation, though mis-sizing due to non-sphericity cannot be ruled out. A small fraction (10 %–30 %) of the particles were undersized by 25 % to 35 %. Those were apparently the particles containing refractory black carbon. Laboratory calibrations confirm that black carbon is drastically undersized by the UHSAS, because particles heat to their vaporization point and shrink. A simple empirical correction equation was implemented that dramatically improves agreement with DMA distributions between 100 and 500 nm. It raised the median particle diameter by 18 nm, from 163 to 181 nm, during the August 2017 deployment and by smaller amounts during deployments with less intense pollution. Calculated scattering from UHSAS size distributions increased by about 130 %, dramatically improving agreement with scattering measured by nephelometers. The correction is only valid in polluted instances; clean marine boundary layer and free troposphere aerosols behaved more like the calibration spheres. We were unable to directly test the correction between 500 and 1000 nm, though aerodynamic particle sizer (APS) data appear to show that the correction is poor at the largest diameters, which is no surprise as the composition of those particles is likely to be quite different than that of the accumulation mode. This adds to the evidence that UHSAS data must be treated cautiously whenever the aerosol may absorb infrared light. Similar corrections may be required whenever brown carbon aerosol is present.

54 ENVIRONMENTAL SCIENCES↗

A novel network-based approach to determining measurement representation error for model evaluation of aerosol microphysical properties

Atmospheric aerosol size and abundance influence radiative effects and climate change. To date, efforts to constrain global climate models’ radiative forcing with in situ aerosol observations have been hamstrung by uncertainty. One source of error, the regional “representation error,” arises when accurate but sparse single-point measurements of atmospheric aerosol distributions are compared with a model value, assuming that the single-point measurement is representative of the model domain. The Portable Optical Particle Spectrometer network in the Southern Great Plains (POPSnet-SGP) campaign has demonstrated that a network of nearly autonomous aerosol instruments operating at ambient temperature and relative humidity (with low measurement error) may be used to quantify measurement representation error and investigate the factors introducing heterogeneity in aerosol distributions across a rural, continental background region. Measurements were made using Portable Optical Particle Spectrometer (POPS) instruments at several sites for five months across the Department of Energy’s Aerosol Radiation Measurement Southern Great Plains (ARM-SGP) User Facility in the central USA. Measurement representation error decreased with longer averaging periods (20-40 % between 1 sec and 1 day), varied between sites by 10 – 20 % for aerosol concentration 140 – 2500 nm in diameter (N_140), and was higher for aerosols > 400 nm in diameter (N_400). Our measurements also show the influence of local meteorology on aerosol surface area (A_140) and size distributions: A_140 is positively correlated with wind speed and relative humidity, negatively correlated with precipitation, and lower given westerly winds. Based on this study, we conclude that the POPSnet approach provides considerably more insight into the spatial variability in the aerosol population that can be used to constrain climate models than would be available from similar networks of PM 2.5 monitors.

54 ENVIRONMENTAL SCIENCES↗

Characterizing the performance of a POPS miniaturized optical particle counter when operated on a quadcopter drone

We first validate the performance of the Portable Optical Particle Spectrometer (POPS), a small light-weight and high sensitivity optical particle counter, against a reference scanning mobility particle sizer (SMPS) for a month-long deployment in an environment dominated by biomass burning aerosols. Subsequently, we examine any biases introduced by operating the POPS on a quadcopter drone, a DJI Matrice 200 V2. We report the root mean square difference (RMSD) and mean absolute difference (MAD) in particle number concentrations (PNCs) when mounted on the UAV and operating on the ground and when hovering at 10 m. When wind speeds are low (less than 2.6 m s –1 ), we find only modest differences in the RMSDs and MADs of 5 % and 3 % when operating at 10 m altitude. When wind speeds are between 2.6 and 7.7 m s –1 the RMSDs and MADs increase to 26.2 % and 19.1 %, respectively, when operating at 10m altitude. No statistical difference in PNCs was detected when operating on the UAV in either ascent or descent. We also find size distributions of aerosols in the accumulation mode (defined by diameter, d, where 0.1 ≤ d ≤ 1 µm) are relatively consistent between measurements at the surface and measurements at 10 m altitude, while differences in the coarse mode (here defined by d > 1 µm) are universally larger. Our results suggest that the impact of the UAV rotors on the POPS PNCs are small at low wind speeds, but when operating under a higher wind speed of up to 7.6 m s –1 , larger discrepancies occur. In addition, it appears that the POPS measures sub-micron aerosol particles more accurately than super-micron aerosol particles when airborne on the UAV. These measurements lay the foundations for determining the magnitude of potential errors that might be introduced into measured aerosol particle size distributions and concentrations owing to the turbulence created by the rotors on the UAV.

47 OTHER INSTRUMENTATION↗

Heterodyne spectrometer sensitivity limit for quantum networking

We report optical heterodyne detection-based spectrometers are attractive due to their relatively simple construction and ultrahigh resolution. Here we demonstrate a proof-of-principle single-mode optical-fiber-based heterodyne spectrometer that has picometer resolution and quantum-limited sensitivity around 1550 nm. Moreover, we report a generalized quantum limit of detecting broadband multispectral-temporal-mode light using heterodyne detection, which provides a sensitivity limit on a heterodyne detection-based optical spectrometer. We then compare this sensitivity limit to several spectrometer types and dim light sources of interest such as spontaneous parametric downconversion, Raman scattering, and spontaneous four-wave mixing. We calculate that the heterodyne spectrometer is significantly less sensitive than a single-photon detector and is unable to detect these dim light sources, except for the brightest and narrowest-bandwidth examples.

47 OTHER INSTRUMENTATION↗

NPFTURBULENCE: Best Estimate Aerosol Size Distribution by airborne measurements

The original data were collected during the field campaign of “Turbulent layers promoting New Particle Formation” experiment (NPFTURBULENCE; https://www.arm.gov/research/campaigns/aaf2024npfturbulence) over the Atmospheric Radiation Measurement (ARM) Southern Great Plains (SGP) Atmospheric Observatory (https://www.arm.gov/capabilities/observatories/sgp ) in north-central Oklahoma. The ARM Aerial Facility ArcticShark uncrewed aerial system (UAS) was based at Blackwell–Tonkawa Municipal Airport (IATA: BWL, ICAO: KBKN, FAA LID: BKN, 36.74475° N, 97.34918° W, 313.9 m MSL), for the field campaign from May 5 through May 29, 2024. The ArcticShark UAS performed 11 flights, including 10 research flights over the Central Facility of the ARM SGP to measure atmospheric state, turbulence, surface IT temperature and imagery, aerosol number concentration and size distribution. The current data set presents Best Estimate Aerosol Size Distribution: a merged aerosol size distribution composed of the data from 2 sensors: miniaturized Scanning Electrical Mobility Sizer (mSEMS) and Portable Optical Particle Spectrometer (POPS). The mSEMS data were interpolated to 1 second from “native” time resolution of about 15 second to match the other probe. The POPS data were converted from equivalent optical size into geometric size using value of aerosol refractive index of 1.477 from the HISCALE field campaign (same geographical area, altitudes, and time of year; http://www.arm.gov/campaigns/aaf2016hiscale ).

54 ENVIRONMENTAL SCIENCES↗

Design of the ion-optics for the MRSt neutron spectrometer at the National Ignition Facility (NIF)

A new Magnetic Recoil Spectrometer (MRSt) is designed to provide time-resolved measurements of the energy spectrum of neutrons emanating from an inertial confinement fusion implosion at the National Ignition Facility. At present, time integrated parameters are being measured using the existing magnet recoil and neutron time-of-flight spectrometers. The capability of high energy resolution of 2 keV and the extension to high time resolution of about 20 ps are expected to improve our understanding of conditions required for successful fusion experiments. The layout, ion-optics, and specifications of the MRSt will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The SHMS 11 GeV/c spectrometer in Hall C at Jefferson Lab

The Super High Momentum Spectrometer (SHMS) has been built for Hall C at the Thomas Jefferson National Accelerator Facility (Jefferson Lab). With a momentum capability reaching 11 GeV/ c , the SHMS provides measurements of charged particles produced in electron-scattering experiments using the maximum available beam energy from the upgraded Jefferson Lab accelerator. The SHMS is an ion-optics magnetic spectrometer comprised of a series of new superconducting magnets which transport charged particles through an array of triggering, tracking, and particle-identification detectors that measure momentum, energy, angle and position in order to allow kinematic reconstruction of the events back to their origin at the scattering target. The detector system is protected from background radiation by a sophisticated shielding enclosure. The entire spectrometer is mounted on a rotating support structure which permits measurements to be taken with a large acceptance over laboratory scattering angles from 5.5° to 40°, thus allowing a wide range of low cross-section experiments to be conducted. Finally, these experiments complement and extend the previous Hall C research program to higher energies.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Total metals, sulfur and organic carbon data; Slate River floodplain, Crested Butte, CO; March 2021-October 2021

This data package includes processed and undiluted measurements for metal, sulfur and organic carbon concentrations from pore water (groundwater) samples from the Slate River floodplain of Crested Butte, CO, a focus field site for the SLAC Floodplain Hydro-Biogeochemistry SFA. The data was generated as part of the work targeting the overarching research question for the SLAC SFA: How do ubiquitous subsurface interfaces mediate molecular-scale biogeochemical processes and groundwater quality in floodplains and watersheds? Samples were collected between March and October of 2021. These measurements were all recorded at the Environmental Measurements Facility (EM-1) at Stanford University in Stanford, CA. Groundwater samples were extracted from a network of installed rhizon (Rhizosphere Research Products, part no. 19.60.21F, 0.6 micrometer mesh size) and piezometer wells within the river floodplain. All water samples were shaded from sun exposure during extraction from the subsurface and preserved at 2C until measured at EM-1.Analysis by ICP-MS:Measurements for total metals were performed on an inductively coupled plasma optical emission spectrometer (ICP-OES; iCAP 6300, Thermo Scientific, Cambridge, U.K.). Calibration standards were prepared from the mulit element stock solution (Sigma-Aldrich Multielement standard for ICP, St. Louis, MO) using matrix matched to sample solutions (2% HNO3). Calibration curves included 5 points with correlation coefficients of >0.99. The QC protocol includes a continuing calibration blank and quality control samples that are analyzed just after calibration and again every 20 samples and at the completion of the run. Acceptable QC responses must be between 90-110% of the certified value. Analysis by Total Organic Carbon:Dissolved organic carbon concentrations were quantified on a total organic carbon (TOC) analyzer (TOC-L, Shimadzu, Kyoto, Japan) running the NPOC method. Standard curves were developed using an Organic Carbon Standard from RICCA Chemical Company (Arlington,TX). A series of 4 to 6 standards were automatically diluted by the instrument in a concentration range that spans that of the samples. A blank sample was run just after the calibration curve and at the end of the run. A QC sample was run every 25 samples. Acceptable QC responses must be between 90-110% of the certified value.All files are in csv format.

54 ENVIRONMENTAL SCIENCES↗

Linear and Non-linear Optical Characterization of Glass and Sapphire for Optical Instrumentation of Advanced Fission Reactors

The linear and nonlinear optical properties of glass and sapphire are investigated to determine the material’s suitability to support optical instrumentation for advanced fission reactors. A post-irradiation examination experiment consisting of a Z-scan, measuring nonlinear optical absorption and refraction, and a spectrometer, measuring linear optical absorption was developed and used. Radiation-induced negative nonlinear optical absorption was observed for the first time in fused silica, sapphire, and borosilicate glass under both types of thermal annealing conditions and the respective effects of thermal annealing are reported.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

POPSnet-SGP: A Pilot Aerosol Microphysics Network for Targeting Climate Model Uncertainty Interim Field Campaign Report

Aerosols mediate the radiative fluxes in clear and cloudy skies and dominate the uncertainty in the radiative forcing of climate. Relatively dense networks of aerosol optical depth measurements have been used to effectively constrain simulated aerosol optical properties, but model diversity of aerosol microphysical properties is much larger (Mann et al. 2014, Myhre et al. 2009). A better understanding of aerosol microphysics is essential as they are the fundamental pieces of information required to convert aerosol emissions information to radiative and cloud-nucleating properties that drive radiative effects and forcing of climate. Model representation of aerosol microphysical properties has lagged in part due to their inherently greater spatial variability, but also due to a lack of available observations. This project – the Printed Optical Particle Spectrometer Network (POPSnet)-Southern Great Plains (SGP) Pilot – launched the first spatially dense network of aerosol size distribution measurements over an area the size of a global model grid cell and demonstrated its use in providing valuable information regarding the spatial variability of aerosol microphysical properties and its drivers for improving model constraints.

54 ENVIRONMENTAL SCIENCES↗