Search NASA⌕ Search

SEARCH · Search NASA

Results for “optical thermometry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Energy dispersive x-ray diffraction of luminescent powders: A complement to visible phosphor thermometry

Energy-dispersive x-ray diffraction of thermographic phosphors has been explored as a complementary temperature diagnostic to visible phosphor thermometry in environments where the temperature-dependent optical luminescence of the phosphors is occluded. Powder phosphor samples were heated from ambient to 300°C in incremental steps and probed with polychromatic synchrotron x rays; scattered photons were collected at a fixed diffraction angle of 3.9°. Crystal structure, lattice parameters, and coefficients of thermal expansion were calculated from the diffraction data. Finally, of the several phosphors surveyed, YAG:Dy, ZnO:Ga, and GOS:Tb were found to be excellent candidates for diffraction thermometry due to their strong, distinct diffraction peaks that shift in a repeatable and linear manner with temperature.

47 OTHER INSTRUMENTATION↗

Temperature Mapping of Stacked Silicon Dies from X-Ray-Diffraction Intensities

Increasing power densities in integrated circuits have led to an increased prevalence of thermal hotspots in integrated circuits. Tracking these thermal hotspots is imperative to prevent circuit failures. In three- dimensional (3D) integrated circuits, conventional surface techniques like infrared thermometry are unable to measure the 3D temperature distribution, and optical and magnetic resonance techniques are difficult to apply due to the presence of metals and large current densities. X-rays offer a high penetration depth and can be used to probe 3D structures. We report a method utilizing the temperature dependence of x-ray-diffraction intensity via the Debye-Waller factor to simultaneously map the temperature of individual silicon dies in a stack. Here, utilizing beamline 1-ID-E at the Advanced Photon Source (Argonne), we demonstrate, for each individual silicon die, a temperature resolution of 3 K, a spatial resolution of 100 × 400 μm 2 , and a temporal resolution of 20 s. Utilizing a sufficiently high-intensity laboratory source, e.g., from a liquid-anode source, this method can be scaled down to laboratories for noninvasive temperature mapping of 3D integrated circuits.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Postirradiation Examination of WIRE-21 Experiment Irradiated in the High Flux Isotope Reactor

Westinghouse Electric Company is developing wireless sensors to monitor the centerline temperature and internal pressure of commercial light-water reactor fuel rods during irradiation. Oak Ridge National Laboratory and Westinghouse Electric Company developed the Wireless Instrumented RB Experiment 2021 (WIRE-21) to test wireless temperature and pressure sensor technologies in a removable beryllium position in the High Flux Isotope Reactor. The experiment was irradiated for a total of 75 days, at temperatures ranging from approximately 150°C to 400°C, resulting in a peak fast (energy > 0.1 MeV) neutron fluence of about 3 × 10 21 n/cm 2 . The temperature was intentionally cycled multiple times to compare the response of the wireless temperature sensor to collocated thermocouples. Similarly, the pressure sensor was actuated in multiple steps to compare the response of the wireless measurement to excore pressure transducers (Petrie et al., 2023). After irradiation, the experiment was disassembled in the Irradiated Fuels Examination Laboratory (IFEL) hot cell at Oak Ridge National Laboratory with the intent to recover sensor and dosimetry components, document the as-irradiated condition of the hardware, and investigate possible causes of the sensor behavior observed during irradiation. The postirradiation examination successfully recovered and preserved key WIRE-21 components. After the housing was removed using a milling machine, the internal experiment sections were examined. All eight fiber-optic sensors were recovered, cut, and stored. The silicon carbide thermometry, temperature sensor, pressure sensor, lower spacer, and selected pressure and temperature cable sections were also removed and stored. The metal bellows of the pressure sensor was found to be plastically deformed, indicating that it had been properly pressurized during irradiation and generally behaved as expected. X-ray diffraction analysis of a section of one of the irradiated inductor cores within the pressure sensor was performed and confirmed the presence of phase-pure alpha ferrite (i.e., no unexpected phase transformations). Inductance testing was performed on the irradiated pressure sensor cores using an unirradiated test coil, and DC resistance measurements of the transceiver coils were also performed. The measurements with irradiated inductor cores assembled inside unirradiated coils showed slightly reduced inductance compared to measurements made with unirradiated cores, but the difference was not sufficient to explain the more significant reductions in inductance that were observed in-pile. Therefore, it is suspected that degradation of the inductor coils (specifically the wire wrapping) is responsible for the reduced inductance observed in-pile.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

WIRE-21 Experiment Irradiation Conditions and In-Situ Data Collection

This report summarizes the in situ data collected during three cycles of irradiation (~75 days) of the Wireless Instrumented Removable Beryllium Experiment 2021 (WIRE-21) in the removable beryllium (RB) positions of the High Flux Isotope Reactor (HFIR). The experiment was designed primarily to evaluate the effects of high neutron flux and fluence on the performance of wireless temperature and pressure sensors being developed by Westinghouse Electric Company (WEC). WEC’s sensors could provide critical data regarding the evolution of centerline temperatures and pressurization due to fission gas release during fuel operation in light-water reactors (LWRs) or various advanced reactor applications. In addition to WEC’s wireless sensors, many other sensors were interrogated, including thermocouples, self-powered neutron detectors (SPNDs), distributed fiber optic temperature sensors, and passive neutron flux wires and silicon carbide thermometry.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Semiconductor yields sensitive thermometry

Here, the strongly temperature-dependent band-edge absorption from gallium arsenide enables an optical thermometer with nanokelvin temperature resolution and microscale spatial resolution.

47 OTHER INSTRUMENTATION↗

SILICON CARBIDE THERMOMETRY USING RAMAN SPECTROSCOPY ON IRRADIATED TRISO PARTICLES

Silicon carbide (SiC) passive thermometry has emerged as a promising post-irradiation examination (PIE) technique for estimating irradiation temperature near the end of irradiation. While dilatometry techniques have been traditionally used to analyze prismatic samples after irradiation, Raman spectroscopy has recently been shown to provide comparable results by analyzing Raman-active phonon modes. In this work, Raman spectroscopy has been applied to the SiC layer of cross-sectioned irradiation tristructural isotropic (TRISO) particles from the AGR-5/6/7 experiment to evaluate the feasibility of particle-scale passive thermometry. Two-dimensional Raman mapping was used to measure the position of the SiC longitudinal optical (LO) phonon, which was then converted to an apparent irradiation temperature using a previously established empirical correlation. Particles from AGR-5/6/7 Compacts 2-2-1 and 5-1-3 were selected as their calculated time-averaged, volume-averaged (TAVA) temperatures (828°C and 706°C, respectively) fall within the range of the sensitivity of the experimental approach. The use of SiC thermometry was anticipated to confirm or highlight potential deviations from calculated end-of-life TAVA temperature across compacts. Four particles from Compact 2-2-1 and two particles from Compact 5-1-3 were selected based on 110mAg inventory (either some measurable activity or below the minimum detection limit) which is commonly used as an indicator of in-pile temperature variation of particles within the same compact. Across every particle selected it was determined that the average LO peak position was located around 968 cm-1 to 969 cm-1. Using the previously determined empirical correlation, this corresponds to an irradiation temperature around 950°C to 966°C, which does not align with the reported TAVA temperature values. This discrepancy in apparent irradiation temperatures likely reflects a combination of uncertainties in the calculated particle temperatures and differences in irradiation history between the present specimens and those used to establish the empirical Raman calibration such as neutron flux (damage rate) and SiC microstructure (as fabricated and irradiated).

Vawdrey, Josh [ORNL]↗

Pre-Ionization Controlled Laser Plasma Formation for Ignition Applications (Final Scientific/Technical Report)

This report consists of three grand funded papers. Abstracts for each follow. 1) In this work, we present experimental and modeling studies of air pre-ionization using ultraviolet (UV) laser pulses and its effect on laser breakdown of an overlapped near-infrared (NIR) pulse. Experimental studies are conducted with a 266 nm beam (fourth harmonic of Nd:YAG) for UV pre-ionization and an overlapped 1064 nm NIR beam (fundamental of Nd:YAG), both having pulse duration of 10 ns. Results show that the UV beam produces a pre-ionized volume which assists in breakdown of the NIR beam, leading to reduction in NIR breakdown threshold by factor of >2. Numerical modeling is performed to examine the ionization and breakdown of both beams. The modeled breakdown threshold of the NIR, including assist by pre-ionization, is in reasonable agreement with the experimental results. 2) The present contribution compares the energy absorption, optical emission, temperature, and fluid dynamics of ultraviolet (UV) λ = 266 nm and near infrared (NIR) λ = 1064 nm nanosecond laser induced plasmas in ambient air. For UV pulses at the conditions studied, energy absorption by the plasmas increases relatively gradually with laser pulse energy starting at delivered energy of E~8 mJ. Corresponding measurements of plasma luminosity show that the absorption of UV radiation does not necessarily result in visible plasma emission. For the NIR induced plasmas, the energy absorption profile is far more abrupt and begins at ~55 mJ. In contrast with UV, the absorption of NIR radiation is always accompanied by intense optical emission. The temperatures of both types of plasma have been measured with Rayleigh scattering thermometry (at times after the Thomson signal sufficiently diminishes). The UV plasmas can attain a wider range of temperatures, including lower temperatures, depending on the pulse energy (e.g., T ~400–2000K for E ~7–35 mJ at Δt = 10 μs after the pulse) while the NIR plasmas show only hotter temperatures (e.g., T ~ 12 000 K for E = 75 mJ at Δt = 10 μs after the pulse) as is consistent with the literature. Differences in the fluid dynamics for UV versus NIR pulses are shown with Schlieren imaging. In this work, the contrast in the UV and NIR plasma threshold behavior is attributed to differing roles of avalanche ionization and multiphoton ionization as is also illustrated by a simple numerical model. 3) The present contribution examines the impact of plasma dynamics and plasma-driven fluid dynamics on the flame growth of laser ignited mixtures and shows that a new dual-pulse scheme can be used to control the kernel formation process in ways that extend the lean ignition limit. We perform a comparative study between (conventional) single-pulse laser ignition (λ = 1064 nm) and a novel dual-pulse method based on combining an ultraviolet (UV) pre-ionization pulse (λ = 266 nm) with an overlapped near-infrared (NIR) energy addition pulse (λ = 1064 nm). We employ OH* chemiluminescence to visualize the evolution of the early flame kernel. For single-pulse laser ignition at lean conditions, the flame kernel separates through third lobe detachment, corresponding to high strain rates that extinguish the flame. In this work, we investigate the capabilities of the dual-pulse to control the plasma-driven fluid dynamics by adjusting the axial offset of the two focal points. In particular, we find there exists a beam waist offset whereby the resulting vorticity suppresses formation of the third lobe, consequently reducing flame stretch. With this approach, we demonstrate that the dual-pulse method enables reduced flame speeds (at early times), an extended lean limit, increased combustion efficiency, and decreased laser energy requirements.

Mechanical engineering↗

Automated bubble analysis of high-speed subcooled flow boiling images using U-net transfer learning and global optical flow

Capturing and analyzing the bubble dynamics is crucial to improving the understanding of boiling heat transfer mechanisms and predicting boiling heat transfer coefficient and boiling crisis. High speed video (HSV) imaging has been used for decades towards this end. Still, there is no universal approach to quantitatively analyze bubble dynamics from HSV images. In this study, we propose a data-driven post-processing approach to segment, track, and identify wall-attached vapor bubbles from HSV images of the boiling process in subcooled flow conditions. Firstly, we employ a transfer learning framework with a U-Net-based convolution neural network (CNN) architecture to detect and segment bubbles in HSV images of diverse contrast and surface texture using very little data (e.g., 10 images) for training. Then, we evaluate the trained CNN model with 100 ground-truth images, and the validation results show that the model accuracy and precision in detecting the optical footprint of bubbles are higher than 90%. Finally, we suggest a criterion to identify a condensing bubble based on the divergence of the bubble displacement, which is calculated from sequential segmented bubble images using a global optical flow code. Using this combination of machine learning and optical flow, we can identify nucleation sites and track the growth of bubbles nucleating at each site to quantify nucleation site density, nucleation frequency, and other fundamental boiling parameters. The proposed system is validated using results obtained on a special heater, which enables both infrared (IR) thermometry and HSV imaging on a metallic surface. We compare the fundamental boiling parameters obtained by the two different diagnostics. The results show good agreement. In conclusion, the difference between the measurements of nucleation site density, averaged nucleation frequency, and averaged growth time performed with the two techniques is always within ± 20% and mostly ± 10% of the values measured with IR thermometry.

42 ENGINEERING↗

Post-detonation fireball thermometry via femtosecond-picosecond coherent anti-Stokes Raman Scattering (CARS)

Accurate knowledge of post-detonation fireball temperatures is important for understanding device performance and for validation of numerical models. Such measurements are difficult to make even under controlled laboratory conditions. Here, temperature measurements were performed in the fireball of a commercial detonator (RP-80, Teledyne RISI). The explosion and fragments were contained in a plastic enclosure with glass windows for optical access. A hybrid femtosecond-picosecond (fs-ps) rotational coherent anti-Stokes Raman scattering (CARS) instrument was used to perform gas-phase thermometry along a one-dimensional measurement volume in a single laser shot. The 13-mm-thick windows on the explosive-containment housing introduced significant nonlinear chirp on the fs lasers pulses, which reduced the Raman excitation bandwidth and did not allow for efficient excitation of high-J Raman transitions populated at flame temperatures. To overcome this, distinct pump and Stokes pulses were used in conjunction with spectral focusing, achieved by varying the relative timing between the pump and Stokes pulses to preferentially excite Raman transitions relevant to flame thermometry. Light scattering from particulate matter and solid fragments was a significant challenge and was mitigated using a new polarization scheme to isolate the CARS signal. Fireball temperatures were measured 35–40 mm above the detonator, 12–25 mm radially outward from the detonator centerline, and at 18 and 28 µs after initiation. At these locations and times, significant mixing between the detonation products and ambient air had occurred thus increasing the nitrogen-based CARS thermometry signal. Initial measurements show a distribution of fireball temperatures in the range 300–2000 K with higher temperatures occurring 28 µs after detonation.

42 ENGINEERING↗

Development of A Multi-Spectral Pyrometry Sensor for High-Speed Transient Surface-Temperature Measurements in Combustion-Relevant Harsh Environments

Accurate and high-speed transient surface-temperature measurements of combustion devices including internal combustion (IC) engines, gas turbines, etc., provide validation targets and boundary conditions for computational fluid dynamics models, and are broadly relevant to technology advancements such as performance improvement and emissions reduction. Development and demonstration of a multi-infrared-channel pyrometry-based optical instrument for high-speed surface-temperature measurement is described. The measurement principle is based on multi-spectral radiation thermometry (MRT) and uses surface thermal radiation at four discrete spectral regions and a corresponding emissivity model to obtain surface temperature via non-linear least squares (NLLS) optimization. Rules of thumb for specifying the spectral regions and considerations to avoid interference with common combustion products are developed; the impact of these along with linear and non-linear MRT analysis are assessed as a function of temperature and signal-to-noise ratio. A multi-start method to determine the MRT-solution global optimum is described and demonstrated. The resulting multi-channel transient pyrometry instrument is described along with practical considerations including optical-alignment drift, matching intra-channel transient response, and solution-confidence indicators. The instrument demonstrated excellent >97% accuracy and >99% 2-sigma precision over the 400–800 °C range, with ~20 µs (50 kHz, equivalent to 0.2 cad at 2000 RPM IC-engine operation) transient response in the bench validation.

47 OTHER INSTRUMENTATION↗

Temperature-dependent x-ray fluorescent response from thermographic phosphors under x-ray excitation

Phosphor thermometry has been successfully applied within several challenging environments. Typically, the thermographic phosphors are excited by an ultraviolet light source, and the temperature-dependent spectral or temporal response is measured. However, this is challenging or impossible in optically thick environments. In addition, emission from other sources (e.g., a flame) may interfere with the optical phosphor emission. Furthermore, a temperature dependent x-ray excitation/emission could alleviate these issues as x-rays could penetrate obscurants with no interference from flame luminosity. In addition, x-ray emission could allow for thermometry within solids while simultaneously x-ray imaging the structural evolution. In this study, select thermographic phosphors were excited via x-ray radiation, and their x-ray emission characteristics were measured at various temperatures. Several of the phosphors showed varying levels of temperature dependence with the strongest sensitivity occurring for YAG:Dy and ZnGa 2 O 4 :Mn. This approach opens a path for less intrusive temperature measurements, particularly in optically opaque multiphase and solid phase combustion environments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Evaluation of liquid-phase thermometry in impinging jet sprays using synchrotron x-ray scattering

Liquid thermometry during primary and secondary breakup of liquid sprays is challenging due to the presence of highly dynamic, optically complex flow features. This work evaluates the use of x-ray scattering from a focused, monochromatic beam of the Advanced Photon Source at Argonne National Laboratory for the measurement of liquid temperatures within the mixing zone of an impinging jet spray. The measured scattering profiles are converted to temperature through a previously developed two-component partial least squares (PLS) regression model. Transmitive mixing during jet merging is inferred through spatial mapping of temperatures within the impingement region. In this work, the technique exhibits uncertainties of ±2K in temperature and 2% in capturing the correct scattering profile, showing its potential utility for probing liquid temperature distributions in multiphase flows.

42 ENGINEERING↗

The impact of 2 H 9/2 → 4 I 13/2 emission from Er 3+ ions on ratiometric optical temperature sensing with Yb 3+ /Er 3+ co-doped upconversion materials

Yb 3+ /Er 3+ co-doped upconversion materials are widely used for luminescence intensity ratio (LIR) thermometry, where the relative intensity ratio of the green luminescence transitions ( 2 H 11/2 4 I 15/2 and 4 S 3/2 4 I 15/2 ) of Er 3+ dopant ions changes with temperature. In this work we report on the impact of an additional transition from the 2 H 9/2 level to the intermediate 4 I 13/2 level, which overlaps with the green luminescence normally used for LIR thermometry. The 2 H 9/2 4 I 13/2 emission overlaps extensively with the 4 S 3/2 4 I 15/2 emission and is more sensitive to pump power. The wavelength intervals used to integrate both 2 H 11/2 4 I 15/2 and 4 S 3/2 4 I 15/2 luminescence need be selected carefully in order to achieve accurate temperature readouts.

36 MATERIALS SCIENCE↗

Equation of State and Thermometry of the 2D SU ( N ) Fermi-Hubbard Model

We characterize the equation of state (EoS) of the SU ( N > 2 ) Fermi-Hubbard Model (FHM) in a two-dimensional single-layer square optical lattice. We probe the density and the site occupation probabilities as functions of interaction strength and temperature for N = 3 , 4, and 6. Our measurements are used as a benchmark for state-of-the-art numerical methods including determinantal quantum Monte Carlo and numerical linked cluster expansion. By probing the density fluctuations, we compare temperatures determined in a model-independent way by fitting measurements to numerically calculated EoS results, making this a particularly interesting new step in the exploration and characterization of the SU ( N ) FHM. Published by the American Physical Society 2024

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Benchmark Analysis for the Optical Dilatometry Method Using Silicon Carbide Temperature Monitors

The main objective of this project was to conduct a benchmark analysis for the optical dilatometry method by using NSUF’s SiC temperature monitors: two (2) SiC temperature monitors provided by NSUF’s BSU-8242 experiment and two (2) SiC temperature monitors provided by NSUF’s GE-Hitachi experiment. Per the BSU-8242 experiment, KGT-3597 and KGT-3591 had a design temperature of 400°C and an exposure of 3 dpa. Per the GE-Hitachi experiment, KGT-3341 and KGT-3336 had a design temperature of 290°C +/- 50°C and an exposure of 0.5–1 dpa. The KGT-3336 SiC monitor was split into two pieces during the decontamination process, making the dilatometry method the only way to analyze both those pieces. The BSU-8242 monitors revealed peak irradiation temperatures under the design temperature, and the GE-Hitachi monitors revealed peak irradiation temperatures within the design temperature range. The optical dilatometry method measured the peak irradiation temperature of BSU-8242 KGT-3597 to be 330°C, while the resistivity method measured the peak irradiation temperature of BSU-8242 KGT-3591 to be 320°C +/- 20°C. The optical dilatometry method measured the peak irradiation temperatures of the pieces of GE-Hitachi KGT-3336 to be 260°C (for the larger piece) and 220°C (for the smaller piece), while the resistivity method measured the peak irradiation temperature of GE-Hitachi KGT-3341 to be 300°C, with an accuracy range of -50°C to +20°C. Both methods of SiC temperature monitor analysis produced very similar peak irradiation temperatures for each pair of SiC passive monitors from the two experiments, BSU-8242 and GE-Hitachi. The results show dilatometry method to be a reliable and less time-intensive process for determining irradiation temperatures from passive SiC thermometry.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Post-Irradiation Examination on MiniFuel UCO and UO 2 TRISO Particles Irradiated in HFIR at High Power

Post-irradiation examination (PIE) of MiniFuel compacts was conducted at Oak Ridge National Laboratory (ORNL) under the Nuclear Science User Facilities project in collaboration with Kairos Power (KP) to evaluate the performance of tristructural-isotropic (TRISO) particles under high particle power and fluoride-salt-cooled high-temperature reactor (FHR)-relevant conditions. MiniFuel compacts containing low-enriched uranium oxide-uranium carbide (LEUCO), low-enriched uranium dioxide (LEUO2), and natural UCO (NUCO) kernels were irradiated for four cycles at ORNL’s High Flux Isotope Reactor (HFIR) at target temperatures between 500°C and 900°C. Post irradiation, the experiment was disassembled at ORNL to recover the MiniFuel subcapsules, which were subsequently punctured to measure fission gas release. Subcapsule disassembly allowed the recovery of components of interest, such as silicon carbide (SiC) thermometry, fuel specimens, fission product sinks, and SiC spacers. The experimental irradiation temperature was confirmed by analyzing the SiC thermometry via dilatometry. PIE on the fuel specimens included gamma spectrometry and deconsolidation leach burn leach, which were complemented by imaging techniques such as x-ray computed tomography, optical microscopy, and electron microscopy. The PIE results provide insight into TRISO particle integrity, fission product retention, coating performance, and kernel migration, informing fuel qualification for application in KP’s FHR concept.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗