Impact of Cross-Axis Projection Error of Optically Pumped Magnetometers on Calibration Accuracy of OPM-MEG Systems.
Abstract not provided.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
An overview of recent development of our MEG system. Most of the included data/figures are already published in the open literature.
Explore the source record for details and available documents.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
In a compact optically pumped atomic magnetometer (OPAM), there is a plateau in the sensitivity where the dependence of the sensitivity on pumping power is small compared with that predicted by the uniform polarization model. The mechanism that generates this plateau was explained by numerical analysis. The distribution of spin polarization in the alkali metal cell of an OPAM was modeled using the Bloch equation incorporating a diffusion term and an equation for the attenuation of the pump beam. The model was well-fitted to the experimental results for a module with a cubic cell with 20 mm sides and pump and probe beams with 8 mm diameter. On the plateau, strong magnetic response was generated at the regions that were not illuminated directly by the intense pump beam, while at the same time spin polarization as large as 0.5 was maintained due to diffusion of the spin-polarized atoms. Thus, the sensitivity of the magnetometer monitored with a probe beam decreases only slightly with increasing pump beam intensity because the spin polarization under an intense pump beam is saturated. This plateau, which is characteristic of this type of magnetometer using a narrow pump and probe beams, can be used in arrays of magnetometers because it enables stable operation with little sensitivity fluctuation from changes in pump beam power.
We have developed a four-channel optically pumped atomic magnetometer for magnetoencephalography (MEG) that incorporates a passive diffractive optical element (DOE). The DOE allows us to achieve a long, 18-mm gradiometer baseline in a compact footprint on the head. Using gradiometry, the sensitivities of the channels are < 5 fT/Hz 1/2 , and the 3-dB bandwidths are approximately 90 Hz, which are both sufficient to perform MEG. Additionally, the channels are highly uniform, which offers the possibility of employing standard MEG post-processing techniques. As a result, this module will serve as a building block of an array for magnetic source localization.
Design and development of optically pumped resonance magnetometer for determining vectoral components in spatial coordinate system
The hybrid optical pumping atomic magnetometers have not realized its theoretical sensitivity, the optimization is critical for optimal performance. The optimizations proposed in this paper are suitable for hybrid optical pumping atomic magnetometer, which contains two alkali species. To optimize the parameters, the dynamic equations of spin evolution with two alkali species were solved, whose steady-state solution is used to optimize the parameters. The demand of the power of the pump beam is large for hybrid optical pumping. Moreover, the sensitivity of the hybrid optical pumping magnetometer increases with the increase of the power density of the pump beam. The density ratio between the two alkali species is especially important for hybrid optical pumping magnetometer. A simple expression for optimizing the density ratio is proposed in this paper, which can help to determine the mole faction of the alkali atoms in fabricating the hybrid cell before the cell is sealed. The spin-exchange rate between the two alkali species is proportional to the saturated density of the alkali vapor, which is highly dependent on the temperature of the cell. Consequently, the sensitivity of the hybrid optical pumping magnetometer is dependent on the temperature of the cell. We proposed the thermal optimization of the hybrid cell for a hybrid optical pumping magnetometer, which can improve the sensitivity especially when the power of the pump beam is low. With these optimizations, a sensitivity of approximately 5 fT/Hz{sup 1/2} is achieved with gradiometer arrangement.
A method is provided for sensing a magnetic field in a magnetic gradiometer of the kind in which pump light and light constituting an optical carrier traverse first and second atomic vapor cells that contain host atoms and that are separated from each other by a known distance. According to such method, the host atoms are prepared in a coherent superposition of two quantum states that differ in energy by an amount that is sensitive to an ambient magnetic field. Modulation of the optical carrier in the respective cells gives rise to sidebands that interfere to generate a beat frequency indicative of the magnetic field gradient. The host atoms are prepared at least in a mode that allows measurement of ambient magnetic field components perpendicular to the axis of the pump light. In such mode, the host atoms are spin-polarized by pump light while subjected to a controlled magnetic field directed parallel to the pump beam, and then the controlled magnetic field is adiabatically extinguished.
An atomic magnetometer, and a method for using same is disclosed. The method for measuring an ambient magnetic field uses an atomic magnetometer that has a probe light beam with a probe axis that probes a polarization vector of an atomic population confined within a vapor cell. The method employs one or more measurement cycles. In each measurement cycle, the polarization vector is prepared in an initial state via an optical pumping pulse. The vapor cell is then subjected to the ambient magnetic field, which results in rotation of the polarization vector by Larmor precession. Within the measurement cycle, at a point in time after the polarization vector has been prepared in the initial state, the ambient magnetic field rotates the direction of the polarization vector, and at least one measurement is made of a projection of the Larmor-rotated polarization vector onto the probe axis during or after application of a magnetic waveform.