Search NASA⌕ Search

SEARCH · Search NASA

Results for “optimal accuracy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Nonlinear elasticity with the Shifted Boundary Method

Here, we propose a new unfitted/immersed computational framework for nonlinear solid mechanics, which bypasses the complexities associated with the generation of CAD representations and subsequent body-fitted meshing. This approach allows to speed up the cycle of design and analysis in complex geometry and requires relatively simple computer graphics representations of the surface geometries to be simulated, such as the Standard Tessellation Language (STL format). Complex data structures and integration on cut elements are avoided by means of an approximate boundary representation and a modification (shifting) of the boundary conditions to maintain optimal accuracy. An extensive set of computational experiments in two and three dimensions is included.

97 MATHEMATICS AND COMPUTING↗

Matrix-free subcell residual distribution for Bernstein finite elements: Monolithic limiting

This paper is focused on the aspects of limiting in residual distribution (RD) schemes for high-order finite element approximations to advection problems. Both continuous and discontinuous Galerkin methods are considered in this work. Discrete maximum principles are enforced using algebraic manipulations of element contributions to the global nonlinear system. The required modifications can be carried out without calculating the element matrices and assembling their global counterparts. The components of element vectors associated with the standard Galerkin discretization are manipulated directly using localized subcell weights to achieve optimal accuracy. Low-order nonlinear RD schemes of this kind were originally developed to calculate local extremum diminishing predictors for flux-corrected transport (FCT) algorithms. In the present paper, we incorporate limiters directly into the residual distribution procedure, which makes it applicable to stationary problems and leads to well-posed nonlinear discrete problems. To circumvent the second-order accuracy barrier, the correction factors of monolithic limiting approaches and FCT schemes are adjusted using smoothness sensors based on second derivatives. Finally, the convergence behavior of presented methods is illustrated by numerical studies for two-dimensional test problems.

97 MATHEMATICS AND COMPUTING↗

EHR-BERT: A BERT-based model for effective anomaly detection in electronic health records

Objective: Physicians and clinicians rely on data contained in electronic health records (EHRs), as recorded by health information technology (HIT), to make informed decisions about their patients. The reliability of HIT systems in this regard is critical to patient safety. Consequently, better tools are needed to monitor the performance of HIT systems for potential hazards that could compromise the collected EHRs, which in turn could affect patient safety. In this paper, we propose a new framework for detecting anomalies in EHRs using sequence of clinical events. This new framework, EHR-Bidirectional Encoder Representations from Transformers (BERT), is motivated by the gaps in the existing deep-learning related methods, including high false negatives, sub-optimal accuracy, higher computational cost, and the risk of information loss. EHR-BERT is an innovative framework rooted in the BERT architecture, meticulously tailored to navigate the hurdles in the contemporary BERT method; thus, enhancing anomaly detection in EHRs for healthcare applications.Methods: The EHR-BERT framework was designed using the Sequential Masked Token Prediction (SMTP) method. This approach treats EHRs as natural language sentences and iteratively masks input tokens during both training and prediction stages. This method facilitates the learning of EHR sequence patterns in both directions for each event and identifies anomalies based on deviations from the normal execution models trained on EHR sequences.Results: Extensive experiments on large EHR datasets across various medical domains demonstrate that EHR-BERT markedly improves upon existing models. It significantly reduces the number of false positives and enhances the detection rate, thus bolstering the reliability of anomaly detection in electronic health records. This improvement is attributed to the model’s ability to minimize information loss and maximize data utilization effectively.Conclusion: EHR-BERT showcases immense potential in decreasing medical errors related to anomalous clinical events, positioning itself as an indispensable asset for enhancing patient safety and the overall standard of healthcare services. The framework effectively overcomes the drawbacks of earlier models, making it a promising solution for healthcare professionals to ensure the reliability and quality of health data.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

High-performance high-resolution semi-Lagrangian tracer transport on a sphere

Current climate models have a limited ability to increase spatial resolution because numerical stability requires the time step to decrease. We describe a semi-Lagrangian method for tracer transport that is stable for arbitrary Courant numbers, and we test a parallel implementation discretized on the cubed sphere. The method includes a fixer that conserves mass and constrains tracers to a physical range of values. The method shows third-order convergence and maintains nonlinear tracer correlations to second order. It shows optimal accuracy at Courant numbers of 10-20, more than an order of magnitude higher than explicit methods. We present parallel performance in terms of strong scaling, weak scaling, and spatial scaling (where the time step stays constant while the resolution increases). For a 0.2° test with 100 tracers, the implementation scales efficiently to 10,000 MPI tasks.

Computer Science↗

SU-E-T-180: Fano Cavity Test of Proton Transport in Monte Carlo Codes Running On GPU and Xeon Phi

Purpose: In proton dose calculation, clinically compatible speeds are now achieved with Monte Carlo codes (MC) that combine 1) adequate simplifications in the physics of transport and 2) the use of hardware architectures enabling massive parallel computing (like GPUs). However, the uncertainties related to the transport algorithms used in these codes must be kept minimal. Such algorithms can be checked with the so-called “Fano cavity test”. We implemented the test in two codes that run on specific hardware: gPMC on an nVidia GPU and MCsquare on an Intel Xeon Phi (60 cores). Methods: gPMC and MCsquare are designed for transporting protons in CT geometries. Both codes use the method of fictitious interaction to sample the step-length for each transport step. The considered geometry is a water cavity (2×2×0.2 cm{sup 3}, 0.001 g/cm{sup 3}) in a 10×10×50 cm{sup 3} water phantom (1 g/cm{sup 3}). CPE in the cavity is established by generating protons over the phantom volume with a uniform momentum (energy E) and a uniform intensity per unit mass I. Assuming no nuclear reactions and no generation of other secondaries, the computed cavity dose should equal IE, according to Fano's theorem. Both codes were tested for initial proton energies of 50, 100, and 200 MeV. Results: For all energies, gPMC and MCsquare are within 0.3 and 0.2 % of the theoretical value IE, respectively (0.1% standard deviation). Single-precision computations (instead of double) increased the error by about 0.1% in MCsquare. Conclusion: Despite the simplifications in the physics of transport, both gPMC and MCsquare successfully pass the Fano test. This ensures optimal accuracy of the codes for clinical applications within the uncertainties on the underlying physical models. It also opens the path to other applications of these codes, like the simulation of ion chamber response.

60 APPLIED LIFE SCIENCES↗

WE-EF-BRA-04: Evaluation of Dosimetric Uncertainties in Individualized Targeted Radionuclide Therapy (TRT) Treatment Planning Using Pre-Clinical Data

Purpose: Dosimetry for targeted radionuclide therapy (TRT) is moving away from conventional model-based methods towards patient-specific approaches. To address this need, a Monte Carlo (MC) dosimetry platform was developed to estimate patient-specific therapeutic 3D dose distributions based on pre-treatment imaging. However, because a standard practice for patient-specific internal dosimetry has not yet been established, there are many sources of dosimetric uncertainties. The goal of this work was to quantify the sensitivity of various parameters on MC dose estimations. Methods: The ‘diapeutic’ agent, CLR1404, was used as a proof-of-principle compound in this work. CLR1404 can be radiolabeled with either {sup 124}I for PET imaging or {sup 131}I for radiotherapy or SPECT imaging. PET/CT images of 5 mice were acquired out to 240 hrs post-injection of {sup 124}I-CLR1404. The therapeutic {sup 131}I-CLR1404 absorbed dose (AD) distribution was calculated using a Geant4-based MC dosimetry platform. A series of sensitivity studies were performed. The variables that were investigated included the PET/CT voxel resolution, partial volume corrections (PVC), material segmentation, inter-observer contouring variability, and the pre-treatment image acquisition frequency. Results: Resampling the PET/CT voxel size between 0.2–0.8 mm resulted in up to a 13% variation in the mean AD. Application of the PVC increased the mean AD by 0.5–11.2%. Less than 1% differences in ROI mean AD were observed between the tissue segmentation schemes using 4 and 27 different material compositions. Inter-observer contouring variability led to up to a 20% CoV (stdev/mean) in the mean AD between the users. Varying the number and frequency of pre-treatment images used resulted in changes in mean AD up to 176% compared to the case using all 12 images. Conclusion: Voxel resolution, contour segmentation, the image acquisition protocol most significantly impacted patient-specific TRT dosimetry. Further work is needed to develop a standard protocol that optimizes accuracy and efficiency for patient-specific internal dosimetry. BT and JG are affiliated with Cellectar Biosciences which owns the licensing rights to CLR1404 and related compounds.

60 APPLIED LIFE SCIENCES↗

JANUS: Resilient and Adaptive Data Transmission for Enabling Timely and Efficient Cross-Facility Scientific Workflows

In modern science, the growing complexity of large-scale scientific projects has led to an increasing reliance on cross-facility scientific workflows, where resources and expertise from multiple institutions and geographic locations are leveraged to accelerate scientific discovery. These workflows often require transmitting huge amounts of scientific data through wide-area networks. Although high-speed networks like ESnet and transfer services such as Globus have improved data mobility, several challenges remain. The sheer volume of data can overwhelm network bandwidth, widely used transport protocols such as TCP suffer from inefficiencies due to retransmissions triggered by packet loss, and existing fault-tolerance mechanisms like erasure coding introduce substantial overhead. In this paper, we propose Janus, a resilient and adaptable data transmission approach designed for cross-facility scientific workflows. Unlike traditional TCP-based methods, Janus leverages UDP, integrates erasure coding for fault tolerance, and combines it with error-bounded lossy compression to reduce overhead. This novel design allows users to balance data transmission time and accuracy, optimizing transfer performance based on specific scientific requirements. Additionally, Janus dynamically adjusts erasure coding parameters in response to real-time network conditions, ensuring efficient data transfers even in fluctuating environments. We develop optimization models for determining ideal configurations and implement adaptive data transfer protocols to enhance reliability. Through extensive simulations and real-network experiments, we demonstrate that Janus significantly improves transfer efficiency while maintaining data fidelity.

Esaulov, Vladislav [Georgia State University, Atla↗

Understanding machine learning approaches for partial differential equations

Recent works in computational physics have been successful in the super-resolution of numerical solutions of partial differential equations (PDEs) via neural networks. In this paper we explore the possibilities and limitations of the data-driven discretization approach implemented by Bar-Sinai et. al., while contrasting it with a simpler yet weaker approach utilizing the nangs Python library. The results demonstrate what neural network parameters optimize accuracy and performance, as well as what conditions on PDEs are necessary to maintain convergence.

97 MATHEMATICS AND COMPUTING↗

Millimeter-wave integrated-horn antennas. I - Theory. II - Experiment

Full-wave analysis is employed to determine the far-field pattern and input impedance of a dipole-fed horn antenna in a ground plane, and the theoretical results are compared with mm-wave and microwave data. The theoretical work exploits the Green's function corresponding to the horn structure and the method of moments. It is determined that the horn should have 70 sections/wavelength and 50 secondary modes for optimized accuracy, and certain dipole positions can reduce the resonance to zero. The experimentally derived impedance and radiation patterns agree with the constraints developed theoretically. The 70-degree flare-angle horn with selected dipole positions and horn apertures yields good radiation patterns, cross-polarization levels, and resonant dipole impedances. The conclusions are of interest to the development of the horn antennas etched in Si/GaAs for applications to zero-visibility tracking, radio astronomy, plasma diagnostics, and remote sensing.

Eleftheriades, George V.↗

A numerical treatment of geodynamic viscous flow problems involving the advection of material interfaces

Effective numerical treatment of multicomponent viscous flow problems involving the advection of sharp interfaces between materials of differing physical properties requires correction techniques to prevent spurious diffusion and dispersion. We develop a particular algorithm, based on modern shock-capture techniques, employing a two-step nonlinear method. The first step involves the global application of a high-order upwind scheme to a hyperbolic advection equation used to model the distribution of distinct material components in a flow field. The second step is corrective and involves the application of a global filter designed to remove dispersion errors that result from the advection of discontinuities (e.g., material interfaces) by high-order, minimally dissipative schemes. The filter introduces no additional diffusion error. Nonuniform viscosity across a material interface is allowed for by the implementation of a compositionally weighted-inverse interface viscosity scheme. The combined method approaches the optimal accuracy of modern shock-capture techniques with a minimal increase in computational time and memory. A key advantage of this method is its simplicity to incorporate into preexisting codes be they finite difference, element, or volume of two or three dimensions.

Lenardic, A.↗

A 3-Channel Algorithm for Retrieving Spatially and Temporally Continuous Cloud Properties Across Different Geostationary Satellite Imagers

Cloud property retrieval algorithms for passive satellite imagers are generally designed to take advantage of all the useful spectral information available for a particular satellite. This strategy optimizes accuracy and reduces misidentification and retrieval biases, particularly for modern satellites with many spectral channels. However, the application of dissimilar algorithms tailored for different satellite sensor scan present a problem within the climate data record (CDR). Algorithm inconsistencies can introduce artificial trends in the CDR that are tied to instrument changes rather than physical changes, especially when older satellites with limited spectral information are included. The NASA CERES (Clouds and the Earth’s Radiant Energy System) data record provides global cloud property retrievals across 23 years and more than 25 satellites. With the goal of producing a spatially and temporally continuous record of cloud properties, the CERES cloud working group has developed algorithms that use only 3 channels that are common to most geostationary satellite imagers: 0.65, 3.9, and 10.8 μm.

Sarah Bedka↗

Evaluating Property Model Accuracy for Cost Optimization of Desalination Technologies

Conference presentation conveying work conducted on property modeling and implications on cost optimization of seawater desalination technology. The authors assess the accuracy of four different property modeling approaches to represent thermodynamic properties of seawater. These properties are used with process flowsheets that include either reverse osmosis or mechanical vapor compression. The accuracy of property estimation is related to deviations in process design and levelized cost.

Sakhai, Savannah↗

Star Tracker Accuracy Improvement and Optimization for Attitude Measurement in Three-Axis

High precision attitude measurement systems obviate the need for the beacon from the receiver making it possible for the spacecraft to beam a laser communications signal to a ground station without the ground station advertising its location. The research presented targets new detection and estimation methods to improve the accuracy in locating stars on a focal plane detector, and an understanding of the effects of changes in the optics design parameters and aberration, including defocus, on the navigation solution itself. This understanding can lead to an optimization of the attitude solution with respect to those optics realm parameter changes. The methodology discussed includes the development of a model of a current star tracker system. Using this model, multiple algorithms are implemented, including a multi-hypothesis method (MHT), to detect and estimate the position of the stars on the focal plane detector. It will be shown that using the MHT for detection and estimation, a greater accuracy can be found for each star estimation from more traditional detection and estimation algorithms. The approach then uses the model to develop statistics of the star tracker and the attitude estimation outputs to understand the accuracy, or variance, of the system's attitude solution. This solution is repeated for a range of defocus aberration, and a lower limit to the variance of the attitude solution is shown. A Cramer Rao lower bound solution is derived for the star tracker system and the results are compared to the Monte Carlo analysis from the model and shown to correlate very well. The approach uses a star image not as a Gaussian spot on the focal plane as done in previous work, and use of an image that includes the effects of aberrations of the optic system, and the effects of under-sampling and noise from the focal plane detector as well. Analysis includes exploring a star tracker's accuracy improvement through the combination of focus error and under-sampling effects alone, possibly contradicting conventional wisdom and approaches.

Lichter, Michael J.↗

Higher-order temporal integration for the incompressible Navier–Stokes equations in bounded domains

Here, this paper compares and contrasts higher-order, semi-implicit temporal integration strategies for the incompressible Navier–Stokes methods based on spectral deferred corrections applied to certain gauge or auxiliary variable formulations of the equations. Particular focus is placed on the imposition of boundary conditions in the semi-implicit formulation, the accurate treatment of the pressure term, and the smoothness of the numerical solution for different formulations. The main result presented here is the formulation and numerical validation of a single-step, semi-implicit method called spectral deferred pressure corrections, which can in theory obtain arbitrary formal order of accuracy in time. Lastly, numerical results demonstrate up to eighth-order accuracy, scenarios where optimal temporal accuracy is attained, and scenarios where order reduction is observed due to time-dependent boundary conditions.

97 MATHEMATICS AND COMPUTING↗

SpaRC: scalable sequence clustering using Apache Spark

MOTIVATION: Whole genome shotgun based next-generation transcriptomics and metagenomics studies often generate 100-1000 GB sequence data derived from tens of thousands of different genes or microbial species. Assembly of these data sets requires tradeoffs between scalability and accuracy. Current assembly methods optimized for scalability often sacrifice accuracy and vice versa. An ideal solution would both scale and produce optimal accuracy for individual genes or genomes. RESULTS: In this work we describe an Apache Spark-based scalable sequence clustering application, SparkReadClust (SpaRC), that partitions reads based on their molecule of origin to enable downstream assembly optimization. SpaRC produces high clustering performance on transcriptomes and metagenomes from both short and long read sequencing technologies. It reaches near-linear scalability with input data size and number of compute nodes. SpaRC can run on both cloud computing and HPC environments without modification while delivering similar performance. Our findings demonstrate that SpaRC provides a scalable solution for clustering billions of reads from next-generation sequencing experiments, and Apache Spark represents a cost-effective solution with rapid development/deployment cycles for similar large-scale sequence data analysis problems. AVAILABILITY AND IMPLEMENTATION: https://bitbucket.org/berkeleylab/jgi-sparc.

59 BASIC BIOLOGICAL SCIENCES↗

An analysis of the accuracy of a parameter optimization

The numerical operations involved in a currently used optimization technique are discussed and analyzed with special attention to the numerical accuracy. Alternative methods for deriving linear system transfer functions, finding the relationships between the transfer function coefficients and the design parameters, and solving a matrix equation are presented for more accurate and cost effective solutions.

Baram, Y.↗

Effect of Electrode Geometry on the Classification Performance of Rapid Evaporative Ionization Mass Spectrometric (REIMS) Bacterial Identification

The recently developed automated, high-throughput monopolar REIMS platform is suited for the identification of clinically important microorganisms. Although already comparable to the previously reported bipolar forceps method, optimization of the geometry of monopolar electrodes, at the heart of the system, holds the most scope for further improvements to be made. For this, sharp tip and round shaped electrodes were optimized to maximize species-level classification accuracy. Following optimization of the distance between the sample contact point and tube inlet with the sharp tip electrodes, the overall cross-validation accuracy improved from 77% to 93% in negative and from 33% to 63% in positive ion detection modes, compared with the original 4 mm distance electrode. As an alternative geometry, round tube shaped electrodes were developed. Geometry optimization of these included hole size, number, and position, which were also required to prevent plate pick-up due to vacuum formation. Additional features, namely a metal “X”-shaped insert and a pin in the middle were included to increase the contact surface with a microbial biomass to maximize aerosol production. Following optimization, cross-validation scores showed improvement in classification accuracy from 77% to 93% in negative and from 33% to 91% in positive ion detection modes. Supervised models were also built, and after the leave 20% out cross-validation, the overall classification accuracy was 98.5% in negative and 99% in positive ion detection modes. This suggests that the new generation of monopolar REIMS electrodes could provide substantially improved species level identification accuracies in both polarity detection modes. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Surrogate Neural Architecture Codesign Package (SNAC-Pack)

Neural Architecture Search is a powerful approach for automating model design, but existing methods struggle to accurately optimize for real hardware performance, often relying on proxy metrics such as bit operations. We present Surrogate Neural Architecture Codesign Package (SNAC-Pack), an integrated framework that automates the discovery and optimization of neural networks focusing on FPGA deployment. SNAC-Pack combines Neural Architecture Codesign's multi-stage search capabilities with the Resource Utilization and Latency Estimator, enabling multi-objective optimization across accuracy, FPGA resource utilization, and latency without requiring time-intensive synthesis for each candidate model. We demonstrate SNAC-Pack on a high energy physics jet classification task, achieving 63.84% accuracy with resource estimation. When synthesized on a Xilinx Virtex UltraScale+ VU13P FPGA, the SNAC-Pack model matches baseline accuracy while maintaining comparable resource utilization to models optimized using traditional BOPs metrics. This work demonstrates the potential of hardware-aware neural architecture search for resource-constrained deployments and provides an open-source framework for automating the design of efficient FPGA-accelerated models.

Weitz, Jason [UC, San Diego] (ORCID:00090004631535↗