Search NASA⌕ Search

SEARCH · Search NASA

Results for “optimal placement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Measurement placement in electric power transmission and distribution grids: Review of concepts, methods, and research needs

Sensing and measurement systems are quintessential to the safe and reliable operation of electric power grids. Their strategic placement is of ultimate importance because it is not economically viable to install measurement systems on every node and branch of a power grid, though they need to be monitored. An overwhelming number of strategies have been developed to meet oftentimes multiple conflicting objectives. The prime challenge in formulating the problem lies in developing a heuristic or an optimisation model that, though mathematically tractable and constrained in cost, leads to trustworthy technical solutions. Further, large-scale, long-term deployments pose additional challenges because the boundary conditions change as technologies evolve. For instance, the advent of new technologies in sensing and measurement, as well as in communications and networking, might impact the cost and performance of available solutions and shift initially set conditions. Also, the placement strategies developed for transmission grids might not be suitable for distribution grids, and vice versa, because of unique characteristics; therefore, the strategies need to be flexible, to a certain extent, because no two power grids are alike. Despite the extensive literature on the present topic, the focus of published works tends to be on a specific subject, such as the optimal placement of measurements to ensure observability in transmission grids. There is a dearth of work providing a comprehensive picture for developing optimal placement strategies. Because of the ongoing efforts on the modernisation of electric power grids, there is a need to consolidate the status quo while exposing its limitations to inform policymakers, industry stakeholders, and researchers on the research-and-development needs to push the boundaries for innovation. Accordingly, this paper first reviews the state-of-the-art considering both transmission and distribution grids. Then, it consolidates the key factors to be considered in the problem formulation. Finally, it provides a set of perspectives on the measurement placement problem, and it concludes with future research directions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Resilient Integrated Resource Planning Framework for Transmission Systems: Analysis and Optimization

This article presents a resilient Integrated Resource Planning (IRP) framework designed for transmission systems, with a specific focus on analyzing and optimizing responses to High-Impact Low-Probability (HILP) events. The framework aims to improve the resilience of transmission networks in the face of extreme events by prioritizing the assessment of events with significant consequences. Unlike traditional reliability-based planning methods that average the impact of various outage durations, this work adopts a metric based on the proximity of outage lines to generators to select HILP events. The system’s baseline resilience is evaluated by calculating load curtailment in different parts of the network resulting from HILP outage events. The transmission network is represented as an undirected graph. Graph-theoretic techniques are used to identify islands with or without generators, potentially forming segmented grids or microgrids. This article introduces Expected Load Curtailment (ELC) as a metric to quantify the system’s resilience. The framework allows for the re-evaluation of system resilience by integrating additional generating resources to achieve desired resilience levels. Optimization is performed in the re-evaluation stage to determine the optimal placement of distributed energy resources (DERs) for enhancing resilience, i.e., minimizing ELC. Case studies on the IEEE 24-bus system illustrate the effectiveness of the proposed framework. In the broader context, this resilient IRP framework aligns with energy sustainability goals by promoting robust and resilient transmission networks, as the optimal placement of DERs for resilience enhancement not only strengthens the system’s ability to withstand and recover from disruptions but also contributes to efficient resource utilization, advancing the overarching goal of energy sustainability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Joint Management and Optimization of Residential Natural Gas and Electricity Distribution Networks Coupled via Fuel Cells

The interesting properties of natural gas as well as the growing electric power demand worldwide have led to increasing attention to natural-gas-based distributed generation applications in electric distribution systems. This paper goes over the interdependency between a residential natural gas network and an electric distribution network that are coupled via fuel cells. The modeling of the gas network is introduced first, and then the algorithm for gas flow study is presented. The optimal placement and sizing of fuel cell based distributed generation systems are formulated to minimize the losses in both the gas and electric distribution networks, subject to their model constraints. In addition to this, in order to capture the probabilistic nature of the optimization problem under study, the K-means clustering algorithm is applied to the gas and electricity demands to determine hourly load states and their corresponding probabilities. Furthermore, simulation studies are carried out on an integrated system consisting of the IEEE 69-bus distribution feeder and a radial 27-node natural gas network to verify the developed optimization model and the proposed method.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Once-Through Steam Generator Model Analysis Using Python and Advanced Optimization Tools (Summer Internship Report)

This study focuses on the parametric analysis of design parameters for a once-through steam generator (OTSG) model, using python and advanced optimization tools to facilitate applications such as the flowing autoclave steam generator (FASG) test cases. Building on previous research involving another OTSG with a different design, this project aims to enhance our understanding of how steam generators (SGs) behave and how their outputs are influenced by changes in design. The reason for this design change is to allow for more precise modeling and optimization of SG performance, to provide a comparative analysis between the two designs, and to set up the model for integration with the FASG test case. The OTSG python-model is a mathematical representation (including fluid flow and heat transfer equations/models/correlations) of a steam-generating unit in a pressurized water reactor-type small modular reactor system. Design studies involve changing the model’s input design parameters to observe the resulting effects on the output of the system. By using advanced optimization tools, such as the Risk Analysis Virtual Environment (RAVEN) developed at Idaho National Laboratory, detailed design parametric studies and model optimization were performed. Six input parameters—pressure, temperature, and mass flow rate for the inlet of the primary-side (hot fluid) and secondary-side (cold fluid), respectively, of the SG—were randomly perturbed via RAVEN’s Monte Carlo Sampler module, using uniform distributions (i.e., ±1%, ±5% and ±10% relative changes) for 600 samples. The analysis provides valuable insights into SG optimization and can be used for sensor placement optimization to effectively monitor and obtain experimental data in other tests.

20 FOSSIL-FUELED POWER PLANTS↗

Joint Management and Optimization of Residential Natural Gas and Electricity Distribution Networks Coupled via Fuel Cells

The attractive features of natural gas as well as the growing electric power demand worldwide have created increasing interest in natural-gas-based distributed generation applications for electric distribution networks. Here, this paper investigates the interdependency between a residential natural gas network and an electric distribution network that are linked together via fuel cells. The modeling of the natural gas network is introduced first, and then the algorithm for gas flow study is presented. The optimal placement and sizing of fuel cell based distributed generation systems are formulated to minimize the losses in both the natural gas network and the electric distribution grid, subject to the constraints imposed by both networks. In addition, a probabilistic model for both gas and electricity demands is developed based on historical electricity and natural gas demand data. A K-means clustering method is used to determine the hourly load states to solve the joint probabilistic optimization problem. Simulation studies are carried out on an integrated system consisting of the IEEE 69-bus distribution network and a radial 27-node natural gas network to verify the developed optimization model and the proposed method.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Revenue Analysis of Stationary and Transportable Battery Storage for Power Systems: A Market Participant Perspective

The power system faces a growing need for increased transmission capacity and reliability with the rising integration of renewable energy resources. To tackle this challenge, Battery Energy Storage Systems (BESSs) prove effective in enhancing grid capacity and relieving transmission congestion. This paper focuses on the PJM market, conducting a thorough revenue analysis to identify and characterize highly profitable nodes for BESS market participants. A comparison between stationary and transportable BESSs reveals that the transportable BESSs can generate higher potential revenue in energy and regulation markets. Based on these findings, we propose an optimal placement algorithm to support market participants in selecting strategic sites for BESS installation, validated with real PJM market data. This paper provides valuable insights for navigating market-based power system participants and promoting the effective integration of BESSs.

25 ENERGY STORAGE↗

Centroidal Voronoi tessellation based methods for optimal rain gauge location prediction

With more satellite and model precipitation data becoming available, new analytical methods are needed that can take advantage of emerging data patterns to make well informed predictions in many hydrological applications. Herein we propose a new strategy where we extract precipitation variability patterns and use correlation map to build the resulting density map that serves as an input to centroidal Voronoi tessellation construction that optimizes placement of precipitation gauges. We provide results of numerical experiments based on the data from the Alto-Adige region in Northern Italy and Oklahoma and compare them against actual gauge locations. This method provides an automated way for choosing new gauge locations and can be generalized to include physical constraints and to tackle other types of resource allocation problems.

54 ENVIRONMENTAL SCIENCES↗

Optimizing green infrastructure placement under precipitation uncertainty

Increased urbanization, infrastructure degradation, and climate change threaten to overwhelm stormwater systems across the nation, rendering them ineffective. Green Infrastructure (GI) practices are low cost, low regret strategies that can contribute to urban runoff management. However, questions remain as to how to best distribute GI practices through urban watersheds given precipitation uncertainty and the variable hydrological responses to them. We develop stochastic programming models to determine the optimal placement of GI practices across a set of candidate locations in a watershed to minimize the total expected runoff under medium-term precipitation uncertainties. Specifically, we first develop a two-stage stochastic programming model. Next, we reformulate this model using perturbed parameters to reduce the requisite computational time and extend it to multi-stage. In addition, we introduce constraints that allow for incorporating sub-catchment-level runoff reduction considerations. Furthermore, we account for hydrological connectivity in the watershed using an underlying acyclic connectivity graph of sub-catchments and incorporate various practical considerations into the models. In addition, we develop a systemic approach to downscale the existing daily precipitation projections into hourly units and efficiently estimate the corresponding hydrological responses. These advancements are brought together in a case study for an urban watershed in a mid-sized city in the U.S., where we perform sensitivity analyses, evaluate the importance of the considered constraints, and provide insights.

54 ENVIRONMENTAL SCIENCES↗

A Vehicle-to-Grid planning framework incorporating electric vehicle user equilibrium and distribution network flexibility enhancement

The rapid surge in electric vehicle (EV) adoption, coupled with advancements in charging technologies, emphasizes the critical necessity for expanding EV recharging infrastructure. Simultaneously, the Distribution Network (DN) encounters escalating challenges in meeting charging demand during peak traffic periods. Consequently, there is a mounting demand for the deployment of innovative Vehicle-to-Grid (V2G) technologies to augment the DN’s flexibility in power dispatch and alleviate travel costs for EV users. Hence, this paper proposes an EV-user-equilibrium-(UE)-constrained V2G planning framework that enhances flexibility in the DN. The framework aims to ascertain the optimal placement and capacity of EV charging stations (EVCSs) and V2G charging piles within the Transportation Network (TN). It takes into account the equilibrium condition stemming from competitive EV charging and routing behaviors alongside the optimal expansion of DN energy resources to accommodate the electricity supplied by the V2G piles. This study commences by analyzing EV drivers’ travel decisions, considering the influence of charging and V2G pile locations and sizes. Subsequently, we tackle the Traffic Assignment Problem with User Equilibrium (TAP-UE) model to characterize the steady-state traffic flow distribution of EVs. Following this, we formulate the optimization model for the Coordinated Power and Transportation Network (CPTN), which encompasses the optimal expansion of DN facilities and traffic flow regulation under UE conditions. To mitigate the computational complexity associated with the V2G planning model, we introduce a series of linearization methods to obtain a manageable Mixed-Integer Linear Programming (MILP) solution. Finally, to validate the efficacy of our proposed planning framework, we apply it to two test systems, including a real-world case study. Through these case studies, we explore the necessity and potential benefits of V2G technologies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Strategic Placement and Sizing of Distributed Generation for Resilience Enhancement of Distribution Grids With Microgrid Formation

The rise in frequency and severity of extreme weather events highlights the need for resilient power distribution networks. Microgrids can help improve the resilience of distribution grids by providing continuous power supply using local distribution generation (DG) when the distribution grid fails. In this paper, we propose an approach for optimal placement and sizing of DG to form multiple microgrids throughout the distribution network by restoration actions such as switching operations in case of distribution grid outages caused by extreme weather events. Considering the randomness of damaged distribution lines, the DG placement and sizing problem is formulated as a two-stage stochastic mixed-integer program, with the first stage determining the placement and size of DG, and the second stage focusing on minimizing the amount of load shedding through network restoration and microgrid formations for each scenario. Due to the large number of scenarios, the sample average approximation (SAA) method is employed to solve the problem. The results of case studies on a modified IEEE 33 bus distribution grid demonstrate the effectiveness of the proposed DG placement and sizing strategy in improving the resilience of distribution grids by allowing the formation of multiple microgrids. In addition, the robustness and accuracy of the SAA method are validated through various case studies.

Distributed generation planning↗

Topology optimization for the full-cell design of porous electrodes in electrochemical energy storage devices

In this paper, we introduce a density-based topology optimization framework to design porous electrodes for maximum energy storage. We simulate the full cell with a model that incorporates electronic potential, ionic potential, and electrolyte concentration. The system consists of three materials, namely pure liquid electrolyte and the porous solids of the anode and cathode, for which we determine the optimal placement. We use separate electronic potentials to model each electrode, which allows interdigitated designs. As a result, a penalization is required to ensure that the anode and cathode do not touch, i.e., causing a short circuit. We compare multiple 2D designs generated for different fixed conditions, e.g. material properties. A 3D design with complex channel and interlocked structure is also created. All optimized designs are far superior to the traditional monolithic electrode design with respect to energy storage metrics. We observe up to a 750% increase in energy storage for cases with slow effective ionic diffusion within the porous electrode.

25 ENERGY STORAGE↗

Efficient Topology Design Algorithms for Power Grid Stability

The dynamic response of power grids to small disturbances influences their overall stability. This letter examines the effect of network topology on the linearized time-invariant dynamics of electric power systems. The proposed framework utilizes H 2 -norm based stability metrics to study the optimal placement of lines on existing networks as well as the topology design of new networks. The design task is first posed as an NP-hard mixed-integer nonlinear program (MINLP) that is exactly reformulated as a mixed-integer linear program (MILP) using McCormick linearization. To improve computation time, graph-theoretic properties are exploited to derive valid inequalities (cuts) and tighten bounds on the continuous optimization variables. Moreover, a cutting plane generation procedure is put forth that is able to interject the MILP solver and augment additional constraints to the problem on-the-fly. Finally, the efficacy of our approach in designing optimal grid topologies is demonstrated through numerical tests on the IEEE 39-bus network.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Testing unified theories for ozone response in C 4 species

Abstract There is tremendous interspecific variability in O 3 sensitivity among C 3 species, but variation among C 4 species has been less clearly documented. It is also unclear whether stomatal conductance and leaf structure such as leaf mass per area (LMA) determine the variation in sensitivity to O 3 across species. In this study, we investigated leaf morphological, chemical, and photosynthetic responses of 22 genotypes of four C 4 bioenergy species (switchgrass, sorghum, maize, and miscanthus) to elevated O 3 in side‐by‐side field experiments using free‐air O 3 concentration enrichment (FACE). The C 4 species varied largely in leaf morphology, physiology, and nutrient composition. Elevated O 3 did not alter leaf morphology, nutrient content, stomatal conductance, chlorophyll fluorescence, and respiration in most genotypes but reduced net CO 2 assimilation in maize and photosynthetic capacity in sorghum and maize. Species with lower LMA and higher stomatal conductance tended to show greater losses in photosynthetic rate and capacity in elevated O 3 compared with species with higher LMA and lower stomatal conductance. Stomatal conductance was the strongest determinant of leaf photosynthetic rate and capacity. The response of both area‐ and mass‐based leaf photosynthetic rate and capacity to elevated O 3 were not affected by LMA directly but negatively influenced by LMA indirectly through stomatal conductance. These results demonstrate that there is significant variation in O 3 sensitivity among C 4 species with maize and sorghum showing greater sensitivity of photosynthesis to O 3 than switchgrass and miscanthus. Interspecific variation in O 3 sensitivity was determined by direct effects of stomatal conductance and indirect effects of LMA. This is the first study to provide a test of unifying theories explaining variation in O 3 sensitivity in C 4 bioenergy grasses. These findings advance understanding of O 3 tolerance in C 4 grasses and could aid in optimal placement of diverse C 4 bioenergy feedstock across a polluted landscape.

54 ENVIRONMENTAL SCIENCES↗