Search NASA⌕ Search

SEARCH · Search NASA

Results for “oscillation source location”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

The relationship between phase stability and frequency stability and a method of converting between them

A method is presented for obtaining the value of the phase stability from time domain frequency stability measurements. Definition of frequency and phase stability are presented. The various types of noise sources in an oscillator and how their location in the oscillator circuitry determines the resultant phase and frequency noise spectrum are described. With this knowledge, the type of noise spectrum from time domain frequency stability measurements is determined. Using certain conversions, the total phase noise spectrum is obtained, which is integrated to obtain the phase stability. Examples of the conversion process are also presented.

Bohn, P. P.↗

Latest Constraints on Three-Flavor Neutrino Oscillation Parameters from the NOvA Experiment

NOvA, is a two-detector, long-baseline neutrino oscillation experiment located at Fermilab, Batavia, IL, USA. The NOvA experiment was designed primarily to constrain neutrino oscillation parameters by analyzing $\nu_\mu (\bar{\nu}_\mu)$ disappearance and $\nu_e (\bar{\nu}_e)$ appearance data observed at the far detector using a high purity beam of neutrinos and anti-neutrinos from Fermilab's NuMI beamline. The NOvA experiment consists of two functionally identical, finely granulated liquid tracking calorimeters, both situated 14.6 mrad off-axis to the beam direction. The NOvA near detector, situated 100 meters underground and 1 kilometer from the beam source, detects the non-oscillated $\nu_\mu (\bar{\nu}_\mu)$ and beam $\nu_e (\bar{\nu}_e)$ events. The far detector, located in Ash River, MN, USA, 810 kilometers from the beam source, records the non-oscillated $\nu_\mu (\bar{\nu}_\mu)$ and the oscillated $\nu_\mu (\bar{\nu}_\mu) \to \nu_e (\bar{\nu}_e)$ events. The most recent measurements of three flavor neutrino oscillation parameters based on an analysis of the data collected from neutrino-beam exposure of $26.60 \times 10^{20}$ POT and anti-neutrino beam exposure of $12.50\times 10^{20}$ POT including an additional low energy $\nu_e$ sample, will be discussed here.

Choudhary, Brajesh [Delhi U.] (ORCID:0000000150291↗

Latest Three-Flavor Neutrino Oscillation Results from NOvA

NOvA, is a two-detector, long-baseline neutrino oscillation experiment located at Fermilab, Batavia, IL, USA. NOvA was designed primarily to constrain neutrino oscillation parameters by analyzing $\nu_\mu (\bar{\nu}_\mu)$ disappearance and $\nu_e (\bar{\nu}_e)$ appearance data at the far detector. The Neutrinos at Main Injector (NuMI) beamline at Fermilab provides a high purity beam of neutrinos and anti-neutrinos to the experiment. The NOvA experiments consists of two functionally identical, finely granulated liquid tracking calorimeters, both situated 14.6 mrad off-axis to the beam direction. The NOvA near detector, situated 100 meters underground and 1 kilometer from the beam source, detects the un-oscillated $\nu_\mu (\bar{\nu}_\mu)$ and beam $\nu_e (\bar{\nu}_e)$ events. The far detector, located in Ash River, MN, USA, 810 kilometers from the beam source, records the un-oscillated $\nu_\mu (\bar{\nu}_\mu)$ and the oscillated $\nu_e (\bar{\nu}_e)$ events. The most recent measurements of three flavor neutrino oscillation parameters based on an analysis of the data collected from a neutrino-beam exposure of $26.60 \times 10^{20}$ POT and an anti-neutrino beam exposure of $12.50\times 10^{20}$ POT with an additional low energy $\nu_e$ sample, will be presented in this talk.

Singh, Ishwar↗

Latest Results from the NOvA Experiment

NOvA, is a two-detector, long-baseline neutrino oscillation experiment located at Fermilab, Batavia, IL, USA. The NOvA experiment was designed primarily to constrain neutrino oscillation parameters by analyzing $\nu_\mu (\bar{\nu}_\mu)$ disappearance and $\nu_e (\bar{\nu}_e)$ appearance data observed at the far detector. The Neutrinos at Main Injector (NuMI) beamline at Fermilab provides a high purity beam of neutrinos and anti-neutrinos to the experiment. The NOvA experiment consists of two functionally identical, finely granulated liquid tracking calorimeters, both situated 14.6 mrad off-axis to the beam direction. The NOvA near detector, situated 100 meters underground and 1 kilometer from the beam source, detects the non-oscillated $\nu_\mu (\bar{\nu}_\mu)$ and beam $\nu_e (\bar{\nu}_e)$ events. The far detector, located in Ash River, MN, USA, 810 kilometers from the beam source, records the non-oscillated $\nu_\mu (\bar{\nu}_\mu)$ and the oscillated $\nu_\mu (\bar{\nu}_\mu) \to \nu_e (\bar{\nu}_e)$ events. The latest results on standard 3-flavor neutrino oscillations, joint NOvA-T2K analysis, active-to-sterile neutrino mixing, and non-standard interactions will be presented in this talk.

43 PARTICLE ACCELERATORS↗

Latest Constraints on Three-Flavor Neutrino Oscillation Parameters from the NOvA Experiment.

NOvA, is a two-detector, long-baseline neutrino oscillation experiment located at Fermilab, Batavia, IL, USA. The NOvA experiment was designed primarily to constrain neutrino oscillation parameters by analyzing $\nu_\mu (\bar{\nu}_\mu)$ disappearance and $\nu_e (\bar{\nu}_e)$ appearance data observed at the far detector. The Neutrinos at Main Injector (NuMI) beamline at Fermilab provides a high purity beam of neutrinos and anti-neutrinos to the experiment. The NOvA experiment consists of two functionally identical, finely granulated liquid tracking calorimeters, both situated 14.6 mrad off-axis to the beam direction. The NOvA near detector, situated 100 meters underground and 1 kilometer from the beam source, detects the non-oscillated $\nu_\mu (\bar{\nu}_\mu)$ and beam $\nu_e (\bar{\nu}_e)$ events. The far detector, located in Ash River, MN, USA, 810 kilometers from the beam source, records the non-oscillated $\nu_\mu (\bar{\nu}_\mu)$ and the oscillated $\nu_\mu (\bar{\nu}_\mu) \to \nu_e (\bar{\nu}_e)$ events. The most recent measurements of three flavor neutrino oscillation parameters based on an analysis of the data collected from neutrino-beam exposure of $26.60 \times 10^{20}$ POT and anti-neutrino beam exposure of $12.50\times 10^{20}$ POT including an additional low energy $\nu_e$ sample, will be presented in this talk.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

COUPLED HBO AND NBO VARIATIONS IN THE Z SOURCE GX 5-1: INNER ACCRETION DISK AS THE LOCATION OF QPOs

The simultaneous and coupled evolution of horizontal branch oscillation (HBO) and normal branch oscillation (NBO) in Z-type sources suggests that the production of HBO is connected to NBO and is caused by changes in the physical/radiative properties of the inner accretion disk, although there is a lack of substantial spectral evidence to support this. In this Letter, we present the results of an analysis of an RXTE observation of the Z source GX 5-1, where the 6 Hz NBO is simultaneously detected along with an HBO at 51 Hz. The variations in the intensity and the associated power density spectrum indicate that the HBO and NBO are strongly coupled, originating from the same location in the inner accretion disk. The absence of HBO and NBO in the lower energy bands, an increase in the rms amplitude with energy, and a smooth transition among them suggest that they are produced in the hot inner regions of the accretion disk. Based on a spectral analysis, we found a signature of changing or physically modified inner disk front during the coupled HBO and NBO evolution. We explore the various models to explain the observed phenomenon and propose that the NBO is affiliated to the oscillations in the thick/puffed-up inner region of the accretion disk.

79 ASTRONOMY AND ASTROPHYSICS↗

'Intermittent' solar periodicities

The signal from a stable periodicity can seem to be intermittent when it is partially masked by an unmodelled window function or when the data set is too short to resolve closely spaced periodicities. By taking this into account, short-lived periodicities in solar data can be reinterpreted as evidence for continuously periodic behavior. The periodic sources are located in the solar interior and caused by global oscillation modes. The convective envelope acts as the window for these sources. Recent reports of seven periodicities from 100 to 1000 days are compared with this model. Precise long-term values for the periodicities are predicted and they agree closely with observations. Some elements are suggested that might explain the well-documented 155-day periodicity. Conventional filtering methods to suppress effects of the 11-year cycle are criticized as inadequate.

Wolff, Charles L.↗

Constructing Data-Driven Predictions at the Far Detector for NOvA's Neutrino Oscillation Analysis.

NOvA, is a two-detector, long-baseline neutrino oscillation experiment located at Fermilab, Batavia, IL, USA. It is designed primarily to constrain neutrino oscillation parameters using $\nu_\mu \ (\bar{\nu}_\mu)$ disappearance and $\nu_e \ (\bar{\nu}_e)$ appearance data. The Neutrinos at Main Injector (NuMI) beamline at Fermilab provides a high purity 900 KW intense beam of neutrinos and anti-neutrinos to NOvA. The NOvA Near Detector, located 100m underground and 1km away from the beam source, observes the un-oscillated $\nu_\mu \ (\bar{\nu}_\mu)$ and beam $\nu_e \ (\bar{\nu}_e)$ event spectrum. The Far Detector, located in Ash River, MN, USA, is 809 km from the ND and records the oscillated $\nu_e \ (\bar{\nu}_e)$ and the un-oscillated $\nu_\mu \ (\bar{\nu}_\mu)$ event spectrum. NOvA uses a data-driven technique called extrapolation to predict the expected number of $\nu_\mu \ (\bar{\nu}_\mu)$ and $\nu_e \ (\bar{\nu}_e)$ events at the Far Detector using the Near Detector data. The use of data from a functionally equivalent Near Detector provides a powerful constraint on the systematic uncertainties in NOvA neutrino oscillation analyses. As NOvA continues to add data statistics, a robust constraint on systematics becomes more crucial for neutrino oscillation analysis. The details of the NOvA neutrino oscillation analysis framework and how it constrains dominant systematic uncertainties using the Near Detector data will be discussed in this poster.

43 PARTICLE ACCELERATORS↗

Remote Sensing and Quantization of Analog Sensors

This method enables sensing and quantization of analog strain gauges. By manufacturing a piezoelectric sensor stack in parallel (physical) with a piezoelectric actuator stack, the capacitance of the sensor stack varies in exact proportion to the exertion applied by the actuator stack. This, in turn, varies the output frequency of the local sensor oscillator. The output, F(sub out), is fed to a phase detector, which is driven by a stable reference, F(sub ref). The output of the phase detector is a square waveform, D(sub out), whose duty cycle, t(sub W), varies in exact proportion according to whether F(sub out) is higher or lower than F(sub ref). In this design, should F(sub out) be precisely equal to F(sub ref), then the waveform has an exact 50/50 duty cycle. The waveform, D(sub out), is of generally very low frequency suitable for safe transmission over long distances without corruption. The active portion of the waveform, t(sub W), gates a remotely located counter, which is driven by a stable oscillator (source) of such frequency as to give sufficient digitization of t(sub W) to the resolution required by the application. The advantage to this scheme is that it negates the most-common, present method of sending either very low level signals (viz. direct output from the sensors) across great distances (anything over one-half meter) or the need to transmit widely varying higher frequencies over significant distances thereby eliminating interference [both in terms of beat frequency generation and in-situ EMI (electromagnetic interference)] caused by ineffective shielding. It also results in a significant reduction in shielding mass.

Strauss, Karl F.↗

DUSEL Theory White Paper

The scientific case for a Deep Underground Science and Engineering Laboratory [DUSEL] located at the Homestake mine in Lead, South Dakota is exceptional. The site of this future laboratory already claims a discovery for the detection of solar neutrinos, leading to a Nobel Prize for Ray Davis. Moreover this work provided the first step to our present understanding of solar neutrino oscillations and a chink in the armor of the Standard Model of particle physics. We now know, from several experiments located in deep underground experimental laboratories around the world, that neutrinos have mass and even more importantly this mass appears to fit into the framework of theories which unify all the known forces of nature, i.e. the strong, weak, electromagnetic and gravitational. Similarly, DUSEL can forge forward in the discovery of new realms of nature, housing six fundamental experiments that will test the frontiers of our knowledge: (1) Searching for nucleon decay (the decay of protons and neutrons predicted by grand unified theories of nature); (2) Searching for neutrino oscillations and CP violation by detecting neutrinos produced at a neutrino source (possibly located at Brookhaven National Laboratory and/or Fermi National Laboratory); (3) Searching for astrophysical neutrinos originating from the sun, from cosmic rays hitting the upper atmosphere or from other astrophysical sources, such a supernovae; (4) Searching for dark matter particles (the type of matter which does not interact electromagnetically, yet provides 24% of the mass of the Universe); (5) Looking for the rare process known as neutrino-less double beta decay which is predicted by most theories of neutrino mass and allows two neutrons in a nucleus to spontaneously change into two protons and two electrons; and (6) Searching for the rare process of neutron- anti-neutron oscillations, which would establish violation of baryon number symmetry. A large megaton water Cherenkov detector for neutrinos and nucleon decay, located in DUSEL and roughly 20 times the size of current detectors, can perform the first three of these experiments. The last 3 can utilize the unique environment afforded by DUSEL to perform the most sensitive tests to date. Any one of these experiments can greatly increase our knowledge of nature. The Deep Underground Science and Engineering Laboratory (DUSEL), with a Large Megaton Size Detector, is desperately needed to address a set of fundamental issues in particle and astrophysics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Self-referenced continuous-variable quantum key distribution

Various technologies for continuous-variable quantum key distribution without transmitting a transmitter's local oscillator are described herein. A receiver on an optical transmission channel uses an oscillator signal generated by a light source at the receiver's location to perform interferometric detection on received signals. An optical reference pulse is sent by the transmitter on the transmission channel and the receiver computes a phase offset of the transmission based on quadrature measurements of the reference pulse. The receiver can then compensate for the phase offset between the transmitter's reference and the receiver's reference when measuring quadratures of received data pulses.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Muon neutrino disappearance at MINOS

A strong case has been made by several experiments that neutrinos oscillate, although important questions remain as to the mechanisms and precise values of the parameters. In the standard picture, two parameters describe the nature of how the neutrinos oscillate: the mass-squared difference between states and the mixing angle. The purpose of this thesis is to use data from the MINOS experiment to precisely measure the parameters associated with oscillations first observed in studies of atmospheric neutrinos. MINOS utilizes two similar detectors to observe the oscillatory nature of neutrinos. The Near Detector, located 1 km from the source, observes the unoscillated energy spectrum while the Far Detector, located 735 km away, is positioned to see the oscillation signal. Using the data in the Near Detector, a prediction of the expected neutrino spectrum at the Far Detector assuming no oscillations is made. By comparing this prediction with the MINOS data, the atmospheric mixing parameters are measured to be Δm 32 2 = 2.45 +0.12 -0.12 x 10 -3 eV 2 and sin 2 2θ 32 ) = 1.00 -0.04 +0.00 (> 0.90 at 90% confidence level).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SOFT LAGS IN NEUTRON STAR kHz QUASI-PERIODIC OSCILLATIONS: EVIDENCE FOR REVERBERATION?

High frequency soft reverberation lags have now been detected from stellar mass and supermassive black holes. Their interpretation involves reflection of a hard source of photons onto an accretion disk, producing a delayed reflected emission, with a time lag consistent with the light travel time between the irradiating source and the disk. Independently of the location of the clock, the kHz quasi-periodic oscillation (QPO) emission is thought to arise from the neutron star boundary layer. Here, we search for the signature of reverberation of the kHz QPO emission, by measuring the soft lags and the lag energy spectrum of the lower kHz QPOs from 4U1608-522. Soft lags, ranging from {approx}15 to {approx}40 {mu}s, between the 3-8 keV and 8-30 keV modulated emissions are detected between 565 and 890 Hz. The soft lags are not constant with frequency and show a smooth decrease between 680 Hz and 890 Hz. The broad band X-ray spectrum is modeled as the sum of a disk and a thermal Comptonized component, plus a broad iron line, expected from reflection. The spectral parameters follow a smooth relationship with the QPO frequency, in particular the fitted inner disk radius decreases steadily with frequency. Both the bump around the iron line in the lag energy spectrum and the consistency between the lag changes and the inferred changes of the inner disk radius, from either spectral fitting or the QPO frequency, suggest that the soft lags may indeed involve reverberation of the hard pulsating QPO source on the disk.

79 ASTRONOMY AND ASTROPHYSICS↗

ANTI-PHASE SIGNATURE OF FLARE GENERATED TRANSVERSE LOOP OSCILLATIONS

Transverse loop oscillations observed by the Atmospheric Imaging Assembly instrument on the Solar Dynamics Observatory spacecraft are studied after an impulsive solar flare eruption on 2012 May 8. We have found that a transversely oscillating coronal loop seen in the 171 A bandpass oscillates in anti-phase with respect to adjacent larger loops seen in the 193 A and 211 A bandpasses. These unusual oscillations are analyzed to investigate the excitation mechanism responsible for their initial inwardly directed anti-phase behavior. The transverse oscillations are analyzed by constructing space-time diagrams from cuts made parallel to the projected loop displacements. The displacement time oscillation profiles are background subtracted and fitted with a damped cosine curve that includes a linear change in the period with time. The local magnetic topology of the active region is modeled using potential field source surface extrapolation. It reveals that the loops are anchored in different topological regions with foot point locations identified on either side of the EUV flare peak emission source. In this context, the oscillation characteristics indicate that the excitation mechanism is closely linked to the local magnetic field topology and the reconnection generated wave dynamics in the active region rather than following an external flare blast wave. We discuss how observations such as these may serve to identify reconnection processes in similar quadrupolar active regions.

79 ASTRONOMY AND ASTROPHYSICS↗

Measurements of three-flavor neutrino oscillations from a PISCES two-detector fit to the NOvA Experiment data

NOvA is a long-baseline neutrino oscillation experiment with two functionally identical detectors: a Near Detector (ND) at Fermilab, placed 1 km from the neutrino source, and a Far Detector (FD) located 810 km away from the ND in Minnesota. NOvA s primary physics goals are to measure the neutrino oscillation parameters $\theta_{23}$ and $\Delta m^2_{32}$ with high precision, determine the neutrino mass hierarchy, and constrain the value of $\delta_{CP}$, primarily via the study of muon neutrino to electron neutrino oscillation. Extracting values for oscillation parameters from fits to data usually relies on treating systematic uncertainties as nuisance parameters, a strategy that suffers from poor scalability as the number of uncertainties becomes larger. This work introduces PISCES (Parameter Inference with Systematic Covariance and Exact Statistics), a novel method that circumvents this scalability problem by encoding systematic uncertainties into a covariance matrix. PISCES utilizes a nested minimization in which optimal systematic pulls are first computed using the covariance matrix in an inner minimization step, then the oscillation parameters are profiled over in the outer minimization. PISCES also uses a Poisson Likelihood term, making it ideal for the inclusion of low-statistic samples in the fits. PISCES is a flexible framework that also supports complex fits, such as a joint Near and Far detector fit. In the standard NOvA analysis, oscillation parameters are extracted using an extrapolation technique in which the ND data indirectly constrain the FD prediction via a ratio method. PISCES, on the other hand, enables a simultaneous ND+FD fit, allowing the high-statistics ND data to directly constrain systematic uncertainties across all samples. This thesis presents the full PISCES joint ND+FD fit for the NOvA three-flavor analysis, details its implementation, and evaluates its performance through extensive robustness tests and fake data studies. It also provides a comparison between the PISCES joint ND+FD results and the standard NOvA extrapolation method using the full NOvA 10-year data set. The results demonstrate that PISCES can successfully fit NOvA data while incorporating the constraints from the ND detectors consistently, using physically motivated systematic uncertainties to account for data/MC discrepancies.

Rajaoalisoa, Miriama [Cincinnati U.]↗

PISCES two-detector covariance matrix fit for the NOvA Experiment

NOvA is a long-baseline neutrino oscillation experiment with two functionally identical detectors: a Near Detector (ND) at Fermilab, placed 1 km from the neutrino source, and a Far Detector (FD) located 810 km away from the ND in Minnesota. NOvA's primary physics goals are the precise measurements of neutrino oscillation parameters $\theta_{23}$ and $\Delta m^2_{32}$ , determine the neutrino mass ordering, and constrain the value of $\delta_{CP}$, via the study of muon neutrino to electron neutrino oscillation. In the standard NOvA three-flavor analysis, oscillation parameters are extracted using an extrapolation technique in which the ND data constrain the FD prediction through a ratio method. While this allows for systematic uncertainties sharing the same effects in both detectors to cancel, it remains an FD-only fit and does not fully leverage the constraining power of the high-statistics ND. This analysis proposes a simultaneous ND+FD fit using the PISCES method. PISCES (Parameter Inference with Systematic Covariance and Exact Statistics) is a framework designed to support complex configurations such as a joint ND+FD fit. This allows PISCES to take full advantage of the ND data to directly constrain systematic uncertainties across all samples. In PISCES, systematic uncertainties are encoded in a fractional covariance matrix, and statistical uncertainties are handled with a Poisson likelihood, making the approach well suited for low-statistics samples. For interpretability, we further use a Newton–Raphson + PCA method to recover per-systematic pulls from the covariance formulation. This poster presents the full PISCES joint ND+FD fit for the NOvA three-flavor analysis, describes its implementation and evaluates its performance through extensive robustness tests and fake data studies. It also provides a comparison between the PISCES joint ND+FD results and the standard NOvA extrapolation method.

Rajaoalisoa, Miriama [Cincinnati U.] (ORCID:000000↗

RF Device for Acquiring Images of the Human Body

A safe, non-invasive method for forming images through clothing of large groups of people, in order to search for concealed weapons either made of metal or not, has been developed. A millimeter wavelength scanner designed in a unique, ring-shaped configuration can obtain a full 360 image of the body with a resolution of less than a millimeter in only a few seconds. Millimeter waves readily penetrate normal clothing, but are highly reflected by the human body and concealed objects. Millimeter wave signals are nonionizing and are harmless to human tissues when used at low power levels. The imager (see figure) consists of a thin base that supports a small-diameter vertical post about 7 ft (=2.13 m) tall. Attached to the post is a square-shaped ring 2 in. (=5 cm) wide and 3 ft (=91 cm) on a side. The ring is oriented horizontally, and is supported halfway along one side by a connection to a linear bearing on the vertical post. A planar RF circuit board is mounted to the inside of each side of the ring. Each circuit board contains an array of 30 receivers, one transmitter, and digitization electronics. Each array element has a printed-circuit patch antenna coupled to a pair of mixers by a 90 coupler. The mixers receive a reference local oscillator signal to a subharmonic of the transmitter frequency. A single local oscillator line feeds all 30 receivers on the board. The resulting MHz IF signals are amplified and carried to the edge of the board where they are demodulated and digitized. The transmitted signal is derived from the local oscillator at a frequency offset determined by a crystal oscillator. One antenna centrally located on each side of the square ring provides the source illumination power. The total transmitted power is less than 100 mW, resulting in an exposure level that is completely safe to humans. The output signals from all four circuit boards are fed via serial connection to a data processing computer. The computer processes the approximately 1-MB data set into a three-dimensional image in a matter of seconds. The innovation is to configure the receiver array in a ring topology surrounding the scanned object. The ring is then scanned vertically to cover the necessary two-dimensional surface. This fabrication of the ring is made possible by using planar antenna and circuit technology. A planar circuit board serves as a medium for both antennas and signal processing components. Using this technique, parts counts are kept low, and the cost per element is a small fraction of a waveguide-based system.

Gaier, Todd C.↗

Observation of Disappearance of Muon Neutrinos in the NuMI Beam

The Main Injector Neutrino Oscillation Search (MINOS) is a two detector long-baseline neutrino experiment designed to study the disappearance of muon neutrinos. MINOS will test the v μ → v τ oscillation hypothesis and measure precisely Δm 23 2 and sin 2 2θ 23 oscillation parameters. The source of neutrinos for MINOS experiment is Fermilab's Neutrinos at the Main Injector (NuMI) beamline. The energy spectrum and the composition of the beam is measured at two locations, one close to the source and the other 735 km down-stream in the Soudan Mine Underground Laboratory in northern Minnesota. The precision measurement of the oscillation parameters requires an accurate prediction of the neutrino flux at the Far Detector. This thesis discusses the calculation of the neutrino flux at the Far Detector and its uncertainties. A technique that uses the Near Detector data to constrain the uncertainties in the calculation of the flux is described. The data corresponding to an exposure of 2.5 x 10 20 protons on the NuMI target is presented and an energy dependent disappearance pattern predicted by neutrino oscillation hypotheses is observed in the Far Detector data. The fit to MINOS data, for given exposure, yields the best fit values for Δm$2\atop{23}$ and sin 2 2θ 23 to be (2.38$+0.20\atop{-0.16}$) x 10 -3 eV 2 /c 4 and 1.00 -0.08 , respectively.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗