Search NASA⌕ Search

SEARCH · Search NASA

Results for “overcharging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

High throughput battery failure experimental platform

Addressing the need to increase the sample set to understand the causes of lithium battery thermal runaway, we conceived of an experimental platform with capability to increase the number of runaway experiments (currently 3-5 per week), while also collecting detailed electrochemical impedance spectroscopy measurements (EIS). Once expanded, the platform would enable data collection on 10s to 100s of cells that all experience runaway, thereby creating a statistical database necessary to identify early indication of risk. A primary containment unit to house cylindrical cells of variety NMC811 and of size 21700 (21 mm diameter by 70 mm length) was designed with features such as debris containment, preloaded cells in an exchangeable port, nitrogen ventilation, and exhaust containment. We performed the first overcharge abuse experiments of several 21700 cells, handpicked because of different initial EIS, and demonstrated that EIS changes dramatically during early stages of overcharge, but in a different manner than previous pouch cell experiments. The abuse experiments also revealed the discharge pattern and debris field created during runaway, as well as the cell temperature control and overheat, that must be considered in the primary containment apparatus. We designed and built a switching relay system to permit measurement of EIS without an active charging circuit, and created instrument control software for charging, EIS, and cell temperature control. The late-start funding was insufficient to fully construct the primary containment unit, but the foundational design and knowhow is available for any future work.

25 ENERGY STORAGE↗

An Ultrastable Aqueous Iodine-Hydrogen Gas Battery

Rechargeable hydrogen gas batteries are highly desirable for large-scale energy storage because of their long life cycle, high round trip efficiency, fast reaction kinetics, and hydrogen gas profusion. Coupling advanced cathode chemistries with hydrogen gas anode is an emerging and exciting area of research. Here, a novel high-performance aqueous iodine-hydrogen gas (I 2 -H 2 ) battery using iodine as cathode and hydrogen gas as the electrocatalytic anode in environmentally benign aqueous electrolytes is reported. The working chemistry of the battery involves I 2 /I - solid-liquid reactions occurring over the cathode along with H 2 /H 2 O gas-liquid reactions at the anode, achieving a high rate performance of 100 C and long-lasting stability of over 60 000 cycles. Additionally, the static aqueous I 2 -H 2 battery displays a volumetric capacity of 15.5 Ah L -1 along with good self-healing capability towards cell overcharge. The current battery design exhibits robust electrochemical performance irrespective of acidic, neutral, and alkaline electrolyte systems. This study paves the way towards the industrialization of economically effective, high-power density, and long-term I 2 -H 2 batteries for large-scale energy storage applications.

08 HYDROGEN↗

A Garnet-Type Solid-Electrolyte-Based Molten Lithium–Molybdenum–Iron(II) Chloride Battery with Advanced Reaction Mechanism

Solid-electrolyte-based molten-metal batteries have attracted considerable attention for grid-scale energy storage. Although ZEBRA batteries are considered one of the promising candidates, they still have the potential concern of metal particle growth and ion exchange with the β”-Al 2 O 3 electrolyte. Herein, a Li 6.4 La 3 Zr 1.4 Ta 0.6 O 12 solid-electrolyte-based molten lithium–molybdenum–iron(II) chloride battery (denoted as Li–Mo–FeCl 2 ) operated at temperature of 250 °C, comprising a mixture of Fe and LiCl cathode materials, a Li anode, a garnet-type Li-ion ceramic electrolyte, and Mo additive, is designed to overcome these obstacles. Different from conventional battery reaction mechanisms, this battery revolutionarily synchronizes the reversible Fe–Mo alloying–dealloying reactions with the delithiation–lithiation processes, meaning that the porous Mo framework derived from Fe–Mo alloy simultaneously suppresses the growth of pure Fe particles. By adopting a Li anode and a Li-ion ceramic electrolyte, the corrosion problem between the cathode and the solid electrolyte is overcome. With similar battery cost ($12 kWh –1 ), the theoretical energy density of Li–Mo–FeCl 2 battery surpasses that of a Na–FeCl 2 ZEBRA battery over 25%, to 576 Wh kg –1 and 2216 Wh L –1 , respectively. Experimental results further prove this cell has excellent cycling performance (472 mAh g LiCl –1 after 300 cycles, 50 mg active material) and strong tolerance against the overcharge–overdischarge (3–1.6 V) and freezing–thawing (25–250 °C) incidents.

36 MATERIALS SCIENCE↗

Near Neutral pH Redox Flow Battery with Low Permeability and Long-Lifetime Phosphonated Viologen Active Species

A highly stable phosphonate-functionalized viologen is introduced in this work as the redox-active material in a negative potential electrolyte for aqueous redox flow batteries (ARFBs) operating at nearly neutral pH. The solubility is 1.23 m and the reduction potential is the lowest of any substituted viologen utilized in a flow battery, reaching –0.462 V versus SHE at pH = 9. The negative charges in both the oxidized and the reduced states of 1,1'-bis(3-phosphonopropyl)-[4,4'-bipyridine]-1,1'-diium dibromide ( BPP–Vi ) effect low permeability in cation exchange membranes and suppress a bimolecular mechanism of viologen decomposition. A flow battery pairing BPP–Vi with a ferrocyanide-based positive potential electrolyte across an inexpensive, non-fluorinated cation exchange membrane at pH = 9 exhibits an open-circuit voltage of 0.9 V and a capacity fade rate of 0.016% per day or 0.00069% per cycle. Overcharging leads to viologen decomposition, causing irreversible capacity fade. Our research introduces extremely stable, extremely low-permeating and low reduction potential redox active materials into near neutral ARFBs.

25 ENERGY STORAGE↗

A Green, Fire–Retarding Ether Solvent for Sustainable High–Voltage Li–Ion Batteries at Standard Salt Concentration

Lithium-ion batteries (LIBs) are increasingly encouraged to enhance their environmental friendliness and safety while maintaining optimal energy density and cost-effectiveness. Although various electrolytes using greener and safer glyme solvents have been reported, the low charge voltage (usually lower than 4.0 V vs Li/Li + ) restricts the energy density of LIBs. Herein, tetraglyme, a less-toxic, non-volatile, and non-flammable ether solvent, is exploited to build safer and greener LIBs. It is demonstrated that ether electrolytes, at a standard salt concentration (1 m), can be reversibly cycled to 4.5 V vs Li/Li + . Anchored with Boron-rich cathode-electrolyte interphase (CEI) and mitigated current collector corrosion, the LiNi 0.8 Mn 0.1 Co 0.1 O 2 (NMC811) cathode delivers competitive cyclability versus commercial carbonate electrolytes when charged to 4.5 V. Synchrotron spectroscopic and imaging analyses show that the tetraglyme electrolyte can sufficiently suppress the overcharge behavior associated with the high-voltage electrolyte decomposition, which is advantageous over previously reported glyme electrolytes. The new electrolyte also enables minimal transition metal dissolution and deposition. NMC811||hard carbon full cell delivers excellent cycling stability at C/3 with a high average Coulombic efficiency of 99.77%. In conclusion, this work reports an oxidation-resilient tetraglyme electrolyte with record-high 4.5 V stability and enlightens further applications of glyme solvents for sustainable LIBs by designing Boron-rich interphases.

36 MATERIALS SCIENCE↗

Investigation on the explosion dynamics of large-format lithium-ion pouch cells

Explosion is the most extreme case of thermal runaway of lithium-ion (Li-ion) batteries. In this study, explosion dynamics of large-format Li-ion cells are investigated experimentally and numerically. Overcharge-to-explosion tests are conducted on 40 Ah Li-ion cells with Li[Ni 0.8 Co 0.1 Mn 0.1 ]O 2 cathode. Based on the explosion physics, shockwave and detonation models are used to characterize the shock effect of the cell explosion and evaluate the explosion equivalent. Von Neumann peak is observed on the pressure curves, and the shockwave velocity is supersonic at this time; the unwrinkled spherical flame phenomenon observed in the experiment indicates that it is detonation. Additionally, a geometric model is established based on the real testing scenario, and the explosion behavior is numerically studied. The characteristics of the explosion dynamics process are interpreted and the propagation mechanism of the shockwave are revealed; the deflagration to detonation transition (DDT) phenomenon in this process is caused by the formation of “hot spots”, and the explosion of the cells eventually turns into stable combustion. Here this study fills the gap in the research on thermal runaway of Li-ion cells, especially in the extreme cases of fire and explosion, and provide useful guidance for battery safety.

42 ENGINEERING↗

Virtual refrigerant charge sensing algorithm for residential CO₂ heat pumps

Natural refrigerants are increasingly adopted in next-generation heat pump systems, among which CO₂ heat pumps have attracted significant attention. However, due to their high operating pressures, the leakage risk is higher, resulting in undercharge conditions and degraded heat pump performance. Thus, developing an accurate refrigerant charge level detection technique is necessary to guarantee safe and efficient operation. Although virtual refrigerant charge (VRC) level calculation algorithms for CO₂ heat pumps exist, they typically rely on empirically selected features without a systematic selection framework, leading to multicollinearity and potential overfitting, which limit their prediction accuracy and generalizability. To address these issues, this study proposes a VRC algorithm framework with a systematic feature selection method that identifies physically meaningful and statistically significant features, and is applied using a residential CO₂ heat pump as a case study. The method is extended from previous work on conventional refrigerants to account for charge behavior in CO₂ gas coolers. The selected features include gas cooler outlet density, evaporator pressure, and superheat temperature. The results demonstrate that the proposed feature selection method significantly improves prediction accuracy compared to existing VRC approaches. A relatively small training dataset (∼30 samples) is sufficient for feature identification and model development. The developed algorithm achieves less than 3% prediction error under both undercharge and overcharge conditions, representing reductions of 46.7% and 35.3% compared to two recent reference VRC algorithms for transcritical CO₂ heat pumps reported in the literature. The proposed algorithm and feature selection method enhance leakage detection capability, facilitate the deployment of CO₂ heat pump systems, and contribute to reduced energy waste and maintenance costs.

Guo, Fangzhou [Lawrence Berkeley National Laborato↗

Impacts of common faults on an air conditioner with a microtube condenser and analysis of fault characteristic features

Split system air conditioners are widely used to cool residential buildings, because of their low cost and simplicity. However, their efficiency is impacted by installation faults, which include: improper refrigerant charge (undercharge or overcharge), improper evaporator airflow, liquid line restrictions (LL), and the presence of non-condensable gas (NC) in the refrigerant. No known previously published research has studied the effect of these four faults on a system equipped with a microtube condenser, which has smaller tube size than a traditional condenser and therefore holds less refrigerant charge, but has a different configuration than a microchannel. Furthermore, very few have studied the impacts of LL and NC. Herein this paper describes laboratory fault tests of a microtube-equipped system, compares the fault impacts with those of a traditional system, and considers the characteristic fault features. The tested system uses R-410A refrigerant and has a scroll compressor, a fixed orifice expansion device, and two fin-tube heat exchangers. The tests were carried out under steady operation with a range of fault intensities and operating conditions. The microtube system’s performance degradation from faults is similar to systems with traditional heat exchangers, despite the reduced capacity to hold refrigerant charge.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Advanced diagnostics to evaluate heterogeneity in lithium-ion battery modules

Battery packs for electric and stationary applications experience varied operating conditions, including abuse—e.g., fast charging, overcharging, thermal, vibration, shock, etc.—throughout their lifetimes. Innovative diagnostic tools and algorithms that go beyond single cells and deal with modules and packs are essential for early detection of off-normal issues. High-resolution tools with known detection limits are key to developing appropriate mitigation strategies. With the advent of rapid impedance spectroscopy that can generate a broadband impedance spectrum in ~10 sec, the case for impedance-based diagnostics that can be readily aligned with other methods, such as incremental capacity or dQ.dV -1 , has become promising. This study used the aforementioned diagnostic methods to identify realistic in-vehicle battery abnormalities (e.g., localized self-discharge and non-uniform aging), in series (up to 10S) and parallel (4P) strings, using 16 Ah graphite/NMC cells. The impedance-based diagnostic is found to be sensitive to the string size and state. Depending on the type of abnormality, detection frequency varied. The dQ.dV -1 method showed the potential to detect long-term aging-related heterogeneity in modules. In general, both the impedance and dQ.dV -1 methods were able to detect series strings’ abnormalities, but struggled to find those issues within parallel modules.

25 ENERGY STORAGE↗

Ion Distribution and Cation Exchange at Mica–Electrolyte Interfaces Probed with Deep Potential Molecular Dynamics

Here, we investigate the Stern layer structure and cation exchange mechanism at muscovite mica-electrolyte interfaces using nanosecond timescale molecular dynamics simulations based on deep neural network interatomic potentials trained on Density Functional Theory (DFT) data. Focusing on mica with exposed surface K + interfaced with aqueous NaCl and mica with surface Na + interfaced with KCl solution, we find that K + remains predominantly in inner-sphere configurations, while Na + exhibits notable populations in outer-sphere states. Most importantly, our simulations show that contact with an electrolyte solution results in the co-adsorption of multiple cation species, making the mica surface locally overcharged and thus reshaping the cation speciation in a manner that enhances the tendency of neighboring surface cations to desorb. These findings are consistent with recent experimental observations that co-adsorption of different cation species induces changes in cation speciation and slow kinetics of cation exchange at the muscovite-water interface, providing a basis for their detailed understanding.

36 MATERIALS SCIENCE↗

Heavy Versus Light Lanthanide Selectivity for Graphene Oxide Films is Concentration Dependent

Rare earths are important materials in various technologies such as catalysis and optoelectronics. Graphene oxide (GO) is a promising material for separation applications, including the isolation of lanthanides from complex mixtures. Previous works using fatty acid monolayers have demonstrated preferential heavy versus light lanthanide adsorption, which has been attributed to differences in lanthanide ion size. In this work, we used interfacial X-ray fluorescence measurements to reveal that GO thin films at the air/water interface have no lanthanide selectivity for dilute subphases. However, at high subphase concentrations, ~8 times more Lu is adsorbed than La. By comparing the GO results with an ideal monolayer with a carboxylic acid headgroup, arachidic acid (AA), we demonstrate that the number of Lu ions adsorbed to GO is significantly higher than the number expected to compensate for the surface charge. Vibrational sum frequency generation (SFG) spectroscopy results on both GO thin films and AA monolayers reveal a red-shifted SFG signal in the OH region, which we attribute to partial dehydration of the adsorbed ions and carboxylic acid headgroups. Liquid surface X-ray reflectivity data show that the GO thin film structure does not significantly change between the very dilute and concentrated subphases. We speculate that the functional groups of both GO and AA facilitate cation dehydration, which is essential for ion adsorption. Heavy lanthanide Lu has stronger ion–ion correlations that can overcome the electrostatic repulsion between cations at higher concentrations compared to light lanthanide La, meaning GO and AA can exhibit apparent overcharge with Lu. Lastly, the layered structure of the GO films and reactive chemical nature of GO itself can accommodate ion adsorption.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Elucidating Trivalent Ion Adsorption at Floating Carboxylic Acid Monolayers: Charge Reversal or Water Reorganization?

Here we study the adsorption of trivalent neodymium on floating arachidic acid films at the air–water interface by two complementary surface specific probes, sum frequency generation spectroscopy and X-ray fluorescence near total reflection. In the absence of background ions, neodymium ions compensate for the surface charge of the arachidic acid film at a bulk concentration of 50 μM without any charge reversal. Increasing the bulk concentration to 1 mM does not change the neodymium surface coverage but affects the interfacial water structure significantly. In the presence of a high concentration of NaCl, there is overcharging at 1 mM Nd 3+ , i.e., 30% more Nd 3+ than needed to compensate for the surface charge. These results show that the total coverage of neodymium ions is not enough to describe the complete picture at the interface, and interfacial water and ion coverage needs to be considered together to understand more complex ion adsorption and transport processes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Mechanistic Insights into the Interplay between Ion Intercalation and Water Electrolysis in Aqueous Batteries

Improving electrolyte stability to suppress water electrolysis represents a basic principle for designing aqueous batteries. Herein, we investigate counterintuitive roles that water electrolysis plays in regulating intercalation chemistry. Using the Na x Fe[Fe(CN) 6 ]∥NaTi 2 (PO 4 ) 3 (x < 1) aqueous battery as a platform, we report that high-voltage overcharging can serve as an electrochemical activation approach to achieving concurrent Na-ion intercalation and an electrolytic oxygen evolution reaction. When the cell capacity is intrinsically limited by deficient cyclable Na ions, the electrolytic water oxidation on the cathode allows for extra Na-ion intercalation from the electrolyte to the NaTi 2 (PO 4 ) 3 anode, leading to a major increase in cyclable Na ions and specific capacity. Furthermore, the parasitic oxygen generation and potential transition-metal dissolution, as proved by our synchrotron and imaging tools, can be significantly mitigated with a simple reassembling approach, which enables stable electrochemical performance and sheds light on manipulating ion intercalation and water electrolysis for battery fast charging and recycling.

25 ENERGY STORAGE↗

Real-time power management technique for microgrid with flexible boundaries

In order to diminish the impacts brought by high penetration of renewable energy on the reliability of distribution systems, some distribution networks (e.g. Chattanooga electric power board system) have deployed smart switches (SSs) to island some areas to mitigate outage losses. However, due to intermittency and sharply changing rate of renewable energy, it is likely to experience insufficient or excessive power for islanded areas. Therefore, a microgrid controller featured with flexible boundaries is proposed. With proposed microgrid controller, the microgrid can not only shrink or expand its boundaries according to current renewable energy supply, but also disconnect/connect to the main grid with a designated SS. Furthermore, to ensure the microgrid controller could obtain suitable boundaries on the time scale of seconds, a real-time power management technique with alternative generating algorithm is designed to generate all possible alternative boundaries and choose the optimal one, which is scalable to any topology. In addition, in order to maintain state of charge of batteries within a desirable range, anti-overcharge/discharge strategies are designed. Four comprehensive experiments verify that the implementation of the microgrid controllers can realise flexible boundaries and deal with sharply changing rate of renewable generation or load on the time scale of seconds.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Online and Offline Identification of False Data Injection Attacks in Battery Sensors Using a Single Particle Model

The cells in battery energy storage systems are monitored, protected, and controlled by battery management systems whose sensors are susceptible to cyberattacks. False data injection attacks (FDIAs) targeting batteries’ voltage sensors affect cell protection functions and the estimation of critical battery states like the state of charge (SoC). Inaccurate SoC estimation could result in battery overcharging and over discharging, which can have disastrous consequences on grid operations. This paper proposes a three-pronged online and offline method to detect, identify, and classify FDIAs corrupting the voltage sensors of a battery stack. To accurately model the dynamics of the series-connected cells a single particle model is used and to estimate the SoC, the unscented Kalman filter is employed. FDIA detection, identification, and classification was accomplished using a tuned cumulative sum (CUSUM) algorithm, which was compared with a baseline method, the chi-squared error detector. Online simulations and offline batch simulations were performed to determine the effectiveness of the proposed approach. Throughout the batch simulations, the CUSUM algorithm detected attacks, with no false positives, in 99.83% of cases, identified the corrupted sensor in 97% of cases, and determined if the attack was positively or negatively biased in 97% of cases.

25 ENERGY STORAGE↗

Electrochemical Decomposition of Primary Alcohol Groups in Deep Eutectic Solvents

This work investigates the electrochemical decomposition of an ethylene glycol/sodium chloride electrolyte and a deep eutectic solvent (DES) comprised of ethylene glycol/choline chloride (ethaline). Understanding these reactions can help to better understand the safety risks of overcharge when these electrolytes are used in a battery and to guide the design of DES electrolytes for improved electrochemical stability. Analysis of the decomposition products was performed using a combination of coulometry, gas chromatography, mass spectrometry, and Fourier transform infrared spectroscopy. It was found that even at relatively low (mM) concentrations of water, a stoichiometric rate of hydrogen is produced under cathodic conditions in both the ethaline and EG/NaCl electrolytes. This suggest an electrochemical hydrolysis cathodic decomposition reaction that produces both hydrogen gas and hydroxyl ions. This reaction was verified in both electrolytes by also identifying the liquid phase products. Only liquid phase products were observed under anodic conditions. A suspected alcohol oxidation to aldehyde anodic decomposition reaction was confirmed through a similar analysis of products. A tertiary alcohol only DES was investigated to eliminate these decomposition paths and was found to have increased stability window compared to the primary alcohol.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Impact of Testing Method on Safety Assessment of Aged Li-Ion Cells: Part II – Aged Cells Without Li Plating

Understanding the safety profile of aged Li-ion batteries is essential for developing effective battery management and hazard mitigation strategies. However, most safety assessments have focused on fresh batteries, with just a few calorimetry studies on aged batteries with metal oxide positive electrodes. This study provides a broad assessment of commercial 18650-type Li-ion batteries with NCA, NMC, and LFP positive electrodes, both uncycled and aged under conditions that promoted solid electrolyte interphase (SEI) growth as the dominant degradation mechanism. The cells underwent mechanical (nail penetration, crush), electrical (overcharge, overdischarge), and thermal (accelerating rate calorimetry) abuse tests. Safety was rated on general characteristics such as mass loss, maximum temperature, and EUCAR (European Council for Automotive R&D) hazard level, as well as characteristics specific to individual abuse tests. Generally, aged cells with SEI growth exhibited similar or improved safety compared to uncycled cells, contrasting with our previous findings on NCA cells with Li plating as the dominant aging mechanism (Part I of this series). Yet, some tests and characteristics indicated reduced aged cell safety, such as earlier triggering of mechanical failure. These results emphasize the need to examine aged battery safety across diverse empirical techniques, degradation modes, and chemistries.

Lithium-ion cells↗

Advanced LiFSI-LiPF6 Electrolyte for Wide-Temperature and Thermally Stable Lithium-Ion Batteries

A new optimized LiFSI–LiPF6 dual-salt controlled-solvation electrolyte (E-DS) is demonstrated to enable practical graphite||LiNi0.8Mn0.1Co0.1O2 cells (˜4.0 mAh cm?²) to achieve exceptional performance and safety under extreme conditions. By optimizing anion coordination with the smaller, more dissociating FSI? anion, the E-DS forms ultrathin, dense, and inorganic-rich electrode/electrolyte interphases that dramatically suppress solvent decomposition, transition-metal dissolution, and surface reconstruction compared to the conventional LiPF6/carbonate electrolyte. Consequently, E-DS cells deliver >78% capacity retention after 300 cycles at 60 °C, retain fast discharging capacity at 30 °C, and operate effectively at -20 °C. Most strikingly, fully charged full cells with E-DS, even under overcharging to 4.8 V, show a lower heat evolution in stable formulations — transforming a traditionally unstable high-voltage/high-temperature configuration into an intrinsically safe state. This work establishes a new benchmark for carbonate-containing electrolytes, simultaneously achieving high energy density, fast-discharging capability, wide-temperature operation (-20 to 60 °C), and outstanding thermal safety in nickel-rich lithium-ion batteries.

electrode/electrolyte interphase↗