Results for “overcurrent protection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

34 records · Page 2

Protection schemes used in North American microgrids

This study reviewed existing conventional and nonconventional protection schemes for grid-connected and islanded mode operations in North American microgrid projects. The microgrid projects investigated in this study used different types of distributed energy resources (DERs) and integrated hydropower/diesel generators, gas/steam/wind turbines, and photovoltaic systems with energy storage. In this work, conventional protection schemes were defined as those within the IEEE Standard C37.2-2008, whereas nonconventional schemes were those not defined within this standard. The pros and cons of conventional and nonconventional protection schemes were discussed in detail. The overvoltage, undervoltage, and frequency elements were the most common conventional protection schemes applied in microgrid projects in North America. These protection elements were used to detect the islanded conditions and faults that could not be sensed by overcurrent relays because of small fault currents contributed by low-inertia DERs and power-electronic sources. Directional overcurrent elements were used to distinguish between external (grid) and internal (microgrid) faults. Adaptive protection was the most popular nonconventional protection scheme applied to the microgrid projects. In conclusion, different types of DERs and operational modes must be considered in order to address the protection and control challenges of each microgrid and to obtain the best technical and economical solution.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Digital Grid Twin–Direct Communication Scheme Test Bed for Assessing Relay-to-Relay Radio Antenna and Optical Fiber Performance and Misoperations

This study introduces a novel “Digital Grid Twin–Direct Communication Scheme” test bed. This advanced platform evaluates point-to-point communication between transmitter and receiver relays with optical fiber and radio omnidirectional antenna systems, implemented at the Advanced Protection lab in the Grid Research Innovation and Development Center at Oak Ridge National Laboratory. The increased diversity of energy sources has led to more protective relay misoperations. In North America, microgrid protection schemes now use point-to-point communication along distribution lines between relays to implement advanced logic in nonradial grids that include both high- and low-inertia generators. This trend challenges utilities to minimize misoperations while ensuring rapid fault clearance and accurate selectivity coordination between primary and backup relays. This study assesses relay-to-relay communication schemes by introducing an advanced testing platform based on a digital grid twin protection test bed using a synchronized time source system. The platform evaluates the communication system using radio antennas or optical fiber links by integrating protective relays that operate breakers within the digital twin and record relay events and communication signals. In the experiments, transmitter and receiver relays were configured with inverse time overcurrent and breaker trip detection logic to assess the total time of the communication protection schemes based on the sum of the relay protection element operating time, radio latency, propagation delay, baud rate delay, and relay processing time. These delays were derived from recorded relay events and communication signals from the interface of a real-time simulator set as a digital grid twin. The test bed successfully simulated various electrical faults along a distribution line while ensuring effective and reliable point-to-point communication between transmitter and receiver relays. The radio antenna communication system exhibited latency because of the radio. This latency depends on the baud rate setting and type of radio application; in general, the higher the baud rate, the lower the radio latency. The measured radio latency (for Mirrored Bits with an encryption card at 9,600 bps) was about 9–10 ms. Additionally, calculated propagation delay per mile for radio antennas and optical fiber was 5.36 µs/mi and 8.04 µs/mi, respectively. Optical fiber communication did not demonstrate radio latency. Instead, the protection element operating time depends mainly on the protection logic function set in the relay, and the relay processing time depends on the processing rate of the relay in samples per power system cycle.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Real-Time Model-Adaptive Relaying Applied to Microgrid Protection

In microgrids, the short-circuit current magnitude is significantly limited by more than an order of magnitude due to the relatively small inverter-based resources. Commercially available protective devices for distribution cannot reliably protect a microgrid due to their dependence on the magnitude of the fault current. Moreover, overcurrent relays typically cannot function properly for a microgrid because they are incapable of detecting faults and/or performing the coordination between the relays in inverter-based microgrids operated in the islanded mode. This paper proposes a model-adaptive relay designed to adjust the relay curves based on the available generation and the network topology. The proposed method runs a real-time model of the microgrid, which gathers information from the network to calculate the available short-circuit current in the specified node. The fault current from the model is then used for the adaptive algorithm to calculate the relay settings, considering coordination with the downstream fuses and upstream reclosers. This work presents the validation of the proposed method in Hardware-in-the-Loop, in a hardware testbed as well as field deployed in a real microgrid in East-Tennessee.

24 POWER TRANSMISSION AND DISTRIBUTION↗

DOE 10658 Project Sensitivity-Driven Wide Area Protection (SWAP) Coordination Tools for IBRs

Utilities have seen a rapid increase in solar, wind, and battery energy storage systems that interconnect to their electric system through inverters. Inverter-Based Resources (IBRs) have fault current characteristics that are unlike the fault current response of traditional rotating-machine-based generators, which is well-known and repeatable. IBR’s non-traditional fault current behavior is due to the IBR control scheme, which is configured to provide a clean AC output but also protects the inverter’s sensitive power electronics devices from damage from conditions such as overcurrent. This results in a low fault current magnitude, low or no negative sequence current injection, the variability of sequence component currents, the variability of voltage with respect to current angles, and the lack of inertia. The control scheme also results in a fault current response that can vary between manufacturers and between models of the same manufacturer. High penetration of IBRs can adversely affect the protection schemes applied in areas with high penetration of IBRs. With the proliferation of IBRs, utilities are finding out that conventional protection schemes are not adequately equipped to protect the electric systems. This is mainly because the existing protection elements and practices have been designed based on the fault current response of conventional rotating machines. In several cases, the available literature does not provide any clear solution for the issues when the protection scheme does not operate properly near IBRs. This report identifies various protection challenges due to IBRs that industry is facing, from the utility perspective. Instead of focusing on one issue, this report looks broadly at all the challenges that system protection has experienced with high penetration of IBRs. Based on the IBR response from various utilities during real fault events and gathering perspectives from different utility SMEs via questionnaire, the report summarizes the gathered data and internal experiences.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Utilities Perspective on Protection Challenges with High IBR Penetration

Utilities have seen rapid increase in Solar, Wind, and Battery Energy Storage Resources that interconnect to their electric system through Inverters. Inverter-Based Resources (IBRs) have fault current characteristics that are unlike the fault current response of traditional rotating-machine-based generators, which is well known and repeatable. IBR’s non-traditional fault current behavior is due to the IBR control scheme, which is configured to provide a clean AC output but also protect the inverter’s sensitive power electronics devices from damage, one source of which is overcurrent. This results in low fault current magnitude, low or no negative sequence current injection, the variability of sequence component currents, the variability of voltage with respect to current angles, and the lack of inertia. The control scheme also results in a fault current response that can vary between manufactures and between models of the same manufacturer. High penetration of IBRs can adversely affect the protection schemes applied in areas with high penetration of IBRs. With the proliferation of IBRs, utilities are finding out that conventional protection schemes are not adequately equipped to protect the electric systems. This is mainly because the existing protection elements and practices have been designed based on the fault current response of conventional rotating machines. In several cases, the available literature does not provide any clear solution for the issues when the protection scheme does not operate properly near IBRs. This presentation identifies various protection challenges due to IBRs that industry is facing, from the utility perspective. Instead of facing on one issue, we are looking broadly on all the challenges that system protection has experienced with high penetration of IBRs. Based on the IBR response from various utilities during real fault events and gathering perspective from different utility SMEs via questionnaire, the presentation summarizes on gathered data and internal experiences.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Utility Perspective on Protection Challenges with High Penetration of IBRs

Utilities have seen rapid increase in Solar, Wind, and Battery Energy Storage Resources that interconnect to their electric system through Inverters. Inverter-Based Resources (IBRs) have fault current characteristics that are unlike the fault current response of traditional rotating-machine-based generators, which is well known and repeatable. IBR’s non-traditional fault current behavior is due to the IBR control scheme, which is configured to provide a clean AC output but also protect the inverter’s sensitive power electronics devices from damage, one source of which is overcurrent. This results in low fault current magnitude, low or no negative sequence current injection, the variability of sequence component currents, the variability of voltage with respect to current angles, and the lack of inertia. The control scheme also results in a fault current response that can vary between manufactures and between models of the same manufacturer. High penetration of IBRs can adversely affect the protection schemes applied in areas with high penetration of IBRs. With the proliferation of IBRs, utilities are finding out that conventional protection schemes are not adequately equipped to protect the electric systems. This is mainly because the existing protection elements and practices have been designed based on the fault current response of conventional rotating machines. In several cases, the available literature does not provide any clear solution for the issues when the protection scheme does not operate properly near IBRs. This report / presentation identifies various protection challenges due to IBRs that industry is facing, from the utility perspective. Instead of facing on one issue, this report looks broadly on all the challenges that system protection has experienced with high penetration of IBRs. Based on the IBR response from various utilities during real fault events and gathering perspective from different utility SMEs via questionnaire, the report summarizes on gathered data and internal experiences.

14 SOLAR ENERGY↗

Utility Perspective on Protection Challenges with High IBR Penetration [Slides]

Utilities have seen rapid increase in Solar, Wind, and Battery Energy Storage Resources that interconnect to their electric system through Inverters. Inverter-Based Resources (IBRs) have fault current characteristics that are unlike the fault current response of traditional rotating-machine-based generators, which is well known and repeatable. IBR’s non-traditional fault current behavior is due to the IBR control scheme, which is configured to provide a clean AC output but also protect the inverter’s sensitive power electronics devices from damage, one source of which is overcurrent. This results in low fault current magnitude, low or no negative sequence current injection, the variability of sequence component currents, the variability of voltage with respect to current angles, and the lack of inertia. The control scheme also results in a fault current response that can vary between manufactures and between models of the same manufacturer. High penetration of IBRs can adversely affect the protection schemes applied in areas with high penetration of IBRs. With the proliferation of IBRs, utilities are finding out that conventional protection schemes are not adequately equipped to protect the electric systems. This is mainly because the existing protection elements and practices have been designed based on the fault current response of conventional rotating machines. In several cases, the available literature does not provide any clear solution for the issues when the protection scheme does not operate properly near IBRs. This report identifies various protection challenges due to IBRs that industry is facing, from the utility perspective. Instead of facing on one issue, this report looks broadly on all the challenges that system protection has experienced with high penetration of IBRs. Based on the IBR response from various utilities during real fault events and gathering perspective from different utility SMEs via questionnaire, the report summarizes on gathered data and internal experiences.

14 SOLAR ENERGY↗

Per-Phase and 3-Phase Optimal Coordination of Directional Overcurrent Relays Using Genetic Algorithm

Penetration of the power grid by renewable energy sources, distributed storage, and distributed generators is becoming increasingly common. Increased utilization of these distributed energy resources (DERs) has given rise to additional protection coordination concerns, particularly where they are utilized in an unbalanced manner or where loading among phases is unbalanced. Digital relays such as the SEL-751 (produced by Schweitzer Engineering Laboratories, Pullman, WA, USA) series have the capability of being set on a per-phase basis. This capability is underutilized in common practice. Additionally, in optimization algorithms for determining relay settings, the time-overcurrent characteristics (TOCs) of relays are generally not treated as variables and are assigned before running the optimization algorithm. In this paper, TOC options themselves are treated as discrete variables to be considered in the optimization algorithm. A mixed integer nonlinear programming problem (MINLP) is set up where the goal is to minimize relay operating times. A genetic algorithm (GA) approach is implemented in MATLAB where two cases are considered. In the first case, the TOC and Time dial setting (TDS) of each relay is set on a three-phase basis. In the second case, per-phase settings are considered. Relay TDSs and TOCs are both considered as simultaneous discrete control variables. Despite the stochastic nature of using per-phase settings for unbalanced systems is found to generally allow for shorter operating times. However, for relatively balanced systems, it is best to use three-phase settings if computation time is of importance.

Matthews, Ronald C.↗

Convolutional Neural Network-Based Protection-Zone Classification of Faults in Distribution Feeders with Photovoltaics.

Fault detection and isolation is critical for reliable operation of distribution systems. The ride-through requirements for the distributed energy resources (DER), mandated by the IEEE 1547-2018 standard, makes it challenging to use undervoltage (UV) conditions for fault detection. In addition, with low fault current contribution from these inverter-based DERs, the time-overcurrent relays are also less effective. Thus motivated, this paper presents a learning-based approach for fault detection and localization. A convolutional neural network (CNN)-based model is proposed which uses local voltage and current waveforms from DER locations and feeder substations, for training a zonal classifier. The classifier can be adopted into any relay-like device for discriminating between faults originating from different protection zones. The performance of the proposed approach was tested on publicly available test feeders with distributed photovoltaics (PVs).

Fault localization, convolutional neural networks,↗

Protection System Validation Using Post-Event Anomaly Classification with Machine Learning

Power system protection devices have transitioned over the past few decades from mechanical to analog devices, then to solid state and finally digital. Relays and their associated critical network of equipment have significantly increased in complexity. Even internally, relays have gained significant intricacy, with relatively simple overcurrent or differential functions now being assisted by a myriad of other functions. This is necessary as the grid becomes more complex, but it brings increased difficulty in monitoring and upkeep. Misoperation caused by improper relay settings or malicious actions is a constant challenge faced by all utilities. These improper settings can be difficult to identify and may require exhaustive post-mortem analysis, typically after a major outage event has already occurred. A mechanism is needed for monitoring the behavior of protection systems to validate that they act and perform as expected. This work presents a concept for a machine learning (ML) system capable of validating the performance of protection systems by classifying anomalous events and characterizing protection system responses based solely on available current and voltage measurements. As a first step in its development, an experimental dataset is generated, and a random forest model is implemented with high accuracy in distinguishing four power system scenarios.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Protection System Validation with Machine Learning Anomaly Classification

A poster for the Early Career Poster Session. Power system protection devices have transitioned over the past few decades from mechanical to analog devices, then to solid state and finally digital. Relays and their associated critical network of equipment have significantly increased in complexity. Even internally, relays have gained significant intricacy, with relatively simple overcurrent or differential functions now being assisted by a myriad of other functions. This is necessary as the grid becomes more complex, but it brings increased difficulty in monitoring and upkeep. Misoperation caused by improper relay settings or malicious actions is a constant challenge faced by all utilities. These improper settings can be difficult to identify and may require exhaustive post-mortem analysis, typically after a major outage event has already occurred. A mechanism is needed for monitoring the behavior of protection systems to validate that they act and perform as expected. This work presents a concept for a machine learning (ML) system capable of validating the performance of protection systems by classifying anomalous events and characterizing protection system responses based solely on available current and voltage measurements. As a first step in its development, an experimental dataset is generated, and a random forest model is implemented with high accuracy in distinguishing four power system scenarios.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Post-Event Fault Identification with Machine Learning for Protection System Validation

Power system protection devices have transitioned over the past few decades from mechanical to analog devices, then to solid state and finally digital. Relays and their associated critical network of equipment have significantly increased in complexity. Even internally, relays have gained significant intricacy, with relatively simple overcurrent or differential functions now being assisted by a myriad of other functions. This is necessary as the grid becomes more complex, but it brings increased difficulty in monitoring and upkeep. Misoperation caused by accidental improper relay settings or deliberate malicious actions is a constant challenge faced by all utilities. These improper settings can be difficult to identify and may require exhaustive post-mortem analysis, typically after a major outage event has already occurred. A mechanism is needed for monitoring the behavior of protection systems to validate that their performance falls within expectations. Relays that fail to isolate a fault or trip when there is no system disturbance can be flagged for settings review in situations where this behavior may not have been noticed due to manual restoration or backup protection operations. This work presents a concept for a machine learning (ML) system capable of validating the performance of protection systems by identifying fault events and characterizing protection system responses based solely on available current and voltage measurements. As a first step in its development, an experimental dataset is generated, and a random forest model is implemented with high accuracy in distinguishing four power system scenarios.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

SIW21-95: Hybridizing Synchronous Condensers with Grid-Forming Battery Energy Storage Systems

One of the main challenges associated with deployment of high shares of inverter-based resources (IBRs) in power grid is not only reduced system inertia but also degrading system strength that may cause severe stability impacts. A minimum level of system strength is needed for the power system to remain stable under normal conditions and to return to a steady state condition following a system disturbance. Significant system strength reduction is expected in almost all planned areas for solar and wind generation deployment. Synchronous condensers (SC) have been considered as one main technology to address the system strength issues for the areas with high levels of IBRs. SCs can help improving reliability and resiliency of power system but they do not provide the full range of services needed by power systems for reliable and economic integration of high shares of inverter-coupled variable generation such as PV generation. Services related to active power controls cannot be provided by SCs due to lack of prime mover. Even for provision of reactive power SCs have certain constraints based on their thermal and stability limits. NREL has been conducting research on a hybridized concept that combines SCs with grid forming (GFM) battery energy storage systems (BESS). This super flexible AC transmission system (SuperFACTS) that combines these two technologies in a single plant under the same controller offers a unique scalable set of services to the power system at all levels (transmission, sub-transmission, distribution, islands and isolated microgrids). Depending on use cases, SuperFACTS can be controlled to provide fully dispatchable and flexible operation using energy storage component, provide a full range of existing and future ancillary and reliability services to the grid (similar or better than conventional sources), maintain adequate levels of grid strength and inertia, and provide fault current for proper operation of protection systems. Therefore, this economic and easy to commercialize solution has potential for significant impacts on certain segments of global energy sector. All types of gird services (market based, reliability and resiliency) can be provided by SuperFACTS plants. GFM BESS can act as a self-black start source for each SuperFACTS module, which in turn can act a black start resource for co-located PV and wind power plants, segments of transmission and distribution networks, for conventional power plants, etc. The issue of in-rush currents during black start is addressed by overcurrent capability of SCs. In this paper we describe the results of modeling for SuperFACTS concept.

grid forming↗

Direct current momentary circuit interrupter

A momentary circuit interrupter in series connection with a mechanical switch to provide protection against short circuit faults in a DC power circuit. The momentary circuit interrupter injects a transient voltage pulse via a pulse transformer to reduce a DC fault current to near zero in a DC circuit branch, thus allowing the mechanical switch to disconnect the faulty branch under a near zero-current condition. The power electronic circuit on the primary side of the transformer controls the discharge of a plurality of pre-charged capacitors to generate the transient voltage pulse during the fault interruption process, but otherwise does not incur any power loss during normal operation. The secondary winding of the pulse transformer conducts the main DC current, and is highly conductive to minimize the conduction power loss. The invention provides ultrafast response to a short circuit fault (even faster than solid-state circuit breakers and much faster than hybrid circuit breakers), significantly reduced overcurrent stress in the power system, and/or ultralow conduction power losses.

Shen, Zheng John↗

Provably-Stable Overload Ride-Through Control for Grid-Forming Inverters Using System-Wide Lyapunov Function Analysis

A key challenge associated with a grid-forming (GFM) inverter based resource (IBR) is its behavior during severe grid disturbances: since a GFM inverter regulates voltage in the fast timescale instead of current or power, it may experience a transient overload of current, power and/or energy during a severe grid disturbance. While many promising control strategies for overload ride-through have been proposed over the past two decades, transient stability of the system during and after the transition to an overload ride-through control mode remains difficult to guarantee. In this work, a novel overload ride-through control strategy is proposed for a system of grid-forming inverters that takes both self-protection and system-wide transient stability into account. A proposed system-level supervisory control uses slow communication to pre-emptively assign a set of local ride through control parameters to individual GFM IBR, including a current-limiting virtual reactance, that guarantees that synchronism is still preserved for any set of anticipated grid disturbances. At the core of the supervisory control lies a Lyapunov-function-based routine capable of establishing a strong, albeit conservative, transient stability guarantee for the system. Here, the proposed overload ride-through control strategy is validated via numerical integration of a reduced-order model, as well as through detailed electromagnetic transient (EMT) simulation.

30 DIRECT ENERGY CONVERSION↗

Spatial-Temporal Recurrent Graph Neural Networks for Fault Diagnostics in Power Distribution Systems

Fault diagnostics are extremely important to decide proper actions toward fault isolation and system restoration. The growing integration of inverter-based distributed energy resources imposes strong influences on fault detection using traditional overcurrent relays. This paper utilizes emerging graph learning techniques to build new temporal recurrent graph neural network models for fault diagnostics. The temporal recurrent graph neural network structures can extract the spatial-temporal features from data of voltage measurement units installed at the critical buses. From these features, fault event detection, fault type/phase classification, and fault location are performed. Compared with previous works, the proposed temporal recurrent graph neural networks provide a better generalization for fault diagnostics. Moreover, the proposed scheme retrieves the voltage signals instead of current signals so that there is no need to install relays at all lines of the distribution system. Therefore, the proposed scheme is generalizable and not limited by the number of relays installed. The effectiveness of the proposed method is comprehensively evaluated on the Potsdam microgrid and IEEE 123-node system in comparison with other neural network structures.

24 POWER TRANSMISSION AND DISTRIBUTION↗