Search NASA⌕ Search

SEARCH · Search NASA

Results for “oxygen activity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Using Isothermal Microcalorimetry to Determine Compatibility of Structural Materials with High-Test Hydrogen Peroxide (HTP) Propellant

High-Test Hydrogen Peroxide (HTP) propellant (equal to or greater than 70%) offers many advantages in space launch applications. However, materials used in construction of propulsion systems must be shown to be compatible with HTP. Isothermal Microcalorimetry (IMC) was used to determine the compatibility of several metallic and non-metallic materials with 90% HTP. The results of these experiments agreed with those from immersion bath tests when the values were converted to % Active Oxygen Loss per week (%AOL/wk).

Gostowski, Rudy↗

Using Isothermal Microcalorimetry to Determine Compatibility of Structural Materials with High Test Hydrogen Peroxide (HTP) Propellant

High-Test Hydrogen Peroxide (HTP) propellant (greater than or equal to 70%) offers many advantages in space launch applications; however, materials used in construction of propulsion systems must be shown to be compatible with HTP. Isothermal Microcalorimetry (IMC) was used to determine the compatibility of several metallic and non-metallic materials with 90% HTP. The results of these experiments agreed with those from immersion bath tests when the values were converted to %Active Oxygen Loss per week (%AOL/wk).

Gostowski, Rudy↗

Labor Contractions Enhance Oxygenation and Behavioral Activity of Newborn Rat Pups

Labor contractions help instigate behavioral responses at birth (viz., breathing and suckling) that are vital for the newborn's adaptation to the extrauterine world (Ronca et al., 1996). In the present study, we analyzed the role of labor contractions in postpartum oxygenation and behavioral activity of newborn rat pups. Newborns were observed following either vaginal (V) or cesarean delivery. For cesarean delivery, day 21 pregnant dams' were administered a spinal transaction to eliminate lower body sensation, a laparotomy was performed and the uterus was maintained in a heated (37.5 C) bath. Four rat fetuses in one of the dams' paired uterine horn were compressed (C) to Simulate labor contractions (20 sec/min for 10 min) while four fetuses in the opposite horn were not compressed (NC). Fetuses were surgically removed from the uterus, stroked with a soft brush to mimic postnatal licking by the dam, the umbilical cord occluded. Pups were exposed to room temperature (22 C) for one hr, then nest temperature (33 C) for one hr. PO2, CO2, and O2, saturation were determined at 0, 30, 60, or 120 min post delivery using a blood gas analyzer. V and C delivered neonates showed comparable rates of PO2, CO2 and O2 saturation whereas NC neonates showed depressed levels at all time points (p<0.05). Respiratory rates of V, C and NC neonates increased significantly (p<0.05) over the first two postpartum hrs and did not differ across groups. Postpartum behavioral activity was significantly greater in V and C conditions and positively correlated with postnatal oxygenation. These findings provide further evidence for importance of labor contractions in early postpartum adaptation.

Mills, N. A.↗

Design of high pressure oxygen filter for extravehicular activity life support system, volume 1

The experience of the National Aeronautics and Space Administration (NASA) with extravehicular activity life support emergency oxygen supply subsystems has shown a large number of problems associated with particulate contamination. These problems have resulted in failures of high pressure oxygen component sealing surfaces. A high pressure oxygen filter was designed which would (a) control the particulate contamination level in the oxygen system to a five-micron glass bead rating, ten-micron absolute condition (b) withstand the dynamic shock condition resulting from the sudden opening of 8000 psi oxygen system shutoff valve. Results of the following program tasks are reported: (1) contaminant source identification tests, (2) dynamic system tests, (3) high pressure oxygen filter concept evaluation, (4) design, (5) fabrication, (6) test, and (7) application demonstration.

Wilson, B. A.↗

A spectral study of a radio-frequency plasma-generated flux of atomic oxygen

The active environment of a radio-frequency (RF) plasma generator, with and without low-pressure oxygen, has been characterized through the identification of emission lines in the spectral region from 250 to 900 nm. The environment is shown to be dependent on the partial pressure of oxygen and the power applied to the RF generator. Atomic oxygen has been found in significant amounts as well as atomic hydrogen and the molecular oxygen species O2((sup 1)Sigma). The only charged species observed was the singly charged molecular ion O2(+). With a polymer specimen in the plasma chamber, carbon monoxide was also observed. The significance of these observations with respect to previous studies using this type of generator to stimulate material degradation in space is discussed. The possibility of using these generators as atomic oxygen sources in the development of oxygen atom fluorescence sensors is explored.

Batten, Carmen E.↗

Techniques for Measuring Low Earth Orbital Atomic Oxygen Erosion of Polymers

Polymers such as polyimide Kapton and Teflon FEP (fluorinated ethylene propylene) are commonly used spacecraft materials due to their desirable properties such as flexibility, low density, and in the case of FEP, a low solar absorptance and high thermal emittance. Polymers on the exterior of spacecraft in the low Earth orbit (LEO) environment are exposed to energetic atomic oxygen. Atomic oxygen reaction with polymers causes erosion, which is a threat to spacecraft durability. It is therefore important to understand the atomic oxygen erosion yield (E, the volume loss per incident oxygen atom) of polymers being considered in spacecraft design. The most common technique for determining E is through mass loss measurements. For limited duration exposure experiments, such as shuttle experiments, where the atomic oxygen fluence is often so low that mass loss measurements can not produce acceptable uncertainties, recession measurements based on atomic force microscopy analyses can be used. Equally necessary to knowing the mass loss or recession depth for determining the erosion yield of polymers is the knowledge of the atomic oxygen fluence that the polymers were exposed to in space. This paper discusses the procedures and relevant issues for mass loss and recession depth measurements for passive atomic oxygen erosion yield characterization of polymers, along with techniques for active atomic oxygen fluence and erosion characterization. One active atomic oxygen erosion technique discussed is a new technique based on optical measurements. Details including the use of both semi-transparent and opaque polymers for active erosion measurement are reviewed.

deGroh, Kim K.↗

Oxygen requirements for formation and activity of the squalene expoxidase in Saccharomyces cerevisiae

The effect of oxygen on squalene epoxidase activity in Saccharomyces cerevisiae was investigated. In cells grown in standing cultures, the epoxidase was localized mainly in the 'mitochondrial' fraction. Upon aeration, enzyme activity increased and the newly formed enzyme was associated with the 'microsomal' fraction. At 0.03 percent (vol/vol) oxygen, epoxidase levels doubled, whereas the ergosterol level was only slightly increased. Cycloheximide inhibited the increase in epoxidase under these conditions. An apparent K sub m for oxygen of 0.38 percent (vol/vol) was determined from a crude particulate preparation for the epoxidase.

Jahnke, L.↗

Outer planet satellite return missions using in situ propellant production

In situ production of oxygen and oxygen with hydrogen for utilization as return propellant from the Galilean satellites has been investigated. Europa has emerged as the preferred landing sight because of the availability of water ice and its surface temperature. When oxygen is used with methane transported from earth, a Europa sample return mission requires 4000 kg less estimated earth launch mass than a vehicle using space storable propellant. Neither methane nor oxygen require active refrigeration at Europa. When oxygen and hydrogen are both utilized to form the primary sample return propellant, the required processor mass increases, but the estimated earth launch mass requirement is reduced by an additional 550 kg.

Ash, R. L.↗

On-Orbit Checkout and Activation of the ISS Oxygen Generation System

NASA has developed and; deployed an Oxygen Generation System (OGS) into the Destiny Module of the International Space Station (ISS). The major. assembly; included in this system is the Oxygen Generator Assembly. (OGA) which was developed under NASA contract by Hamilton Sundstrand Space Systems International (HSSSI), Inc. This paper summarizes the installation of the system into the Destiny Module, its initial checkout and periodic preventative maintenance activities, and its operational activation. Trade studies and analyses that were conducted with the goal of mitigating on-orbit operational risks are also discussed.

Bagdigian, Robert M.↗

Importance of interatomic spacing in catalytic reduction of oxygen in phosphoric acid

A correlation between the nearest-neighbor distance and the oxygen reduction activity of various platinum alloys is reported. It is proposed that the distance between nearest-neighbor Pt atoms on the surface of a supported catalyst is not ideal for dual site absorption of O2 or 'HO2' and that the introduction of foreign atoms which reduce the Pt nearest-neighbor spacing would result in higher oxygen reduction activity. This may allow the critical 0-0 bond interatomic distance and hence the optimum Pt-Pt separation for bond rupture to be determined from quantum chemical calculations. A composite analysis shows that the data on supported Pt alloys are consistent with Appleby's (1970) data on bulk metals with respect to specific activity, activation energy, preexponential factor, and percent d-band character.

Jalan, V.↗