Search NASA⌕ Search

SEARCH · Search NASA

Results for “oxygen monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Oxygen Mass Flow Rate Generated for Monitoring Hydrogen Peroxide Stability

Recent interest in propellants with non-toxic reaction products has led to a resurgence of interest in hydrogen peroxide for various propellant applications. Because peroxide is sensitive to contaminants, material interactions, stability and storage issues, monitoring decomposition rates is important. Stennis Space Center (SSC) uses thermocouples to monitor bulk fluid temperature (heat evolution) to determine reaction rates. Unfortunately, large temperature rises are required to offset the heat lost into the surrounding fluid. Also, tank penetration to accomodate a thermocouple can entail modification of a tank or line and act as a source of contamination. The paper evaluates a method for monitoring oxygen evolution as a means to determine peroxide stability. Oxygen generation is not only directly related to peroxide decomposition, but occurs immediately. Measuring peroxide temperature to monitor peroxide stability has significant limitations. The bulk decomposition of 1% / week in a large volume tank can produce in excess of 30 cc / min. This oxygen flow rate corresponds to an equivalent temperature rise of approximately 14 millidegrees C, which is difficult to measure reliably. Thus, if heat transfer were included, there would be no temperature rise. Temperature changes from the surrounding environment and heat lost to the peroxide will also mask potential problems. The use of oxygen flow measurements provides an ultra sensitive technique for monitoring reaction events and will provide an earlier indication of an abnormal decomposition when compared to measuring temperature rise.

Ross, H. Richard↗

Atomic Oxygen Fluence Monitor

This innovation enables a means for actively measuring atomic oxygen fluence (accumulated atoms of atomic oxygen per area) that has impinged upon spacecraft surfaces. Telemetered data from the device provides spacecraft designers, researchers, and mission managers with real-time measurement of atomic oxygen fluence, which is useful for prediction of the durability of spacecraft materials and components. The innovation is a compact fluence measuring device that allows in-space measurement and transmittance of measured atomic oxygen fluence as a function of time based on atomic oxygen erosion yields (the erosion yield of a material is the volume of material that is oxidized per incident oxygen atom) of materials that have been measured in low Earth orbit. It has a linear electrical response to atomic oxygen fluence, and is capable of measuring high atomic oxygen fluences (up to >10(exp 22) atoms/sq cm), which are representative of multi-year low-Earth orbital missions (such as the International Space Station). The durability or remaining structural lifetime of solar arrays that consist of polymer blankets on which the solar cells are attached can be predicted if one knows the atomic oxygen fluence that the solar array blanket has been exposed to. In addition, numerous organizations that launch space experiments into low-Earth orbit want to know the accumulated atomic oxygen fluence that their materials or components have been exposed to. The device is based on the erosion yield of pyrolytic graphite. It uses two 12deg inclined wedges of graphite that are over a grit-blasted fused silica window covering a photodiode. As the wedges erode, a greater area of solar illumination reaches the photodiode. A reference photodiode is also used that receives unobstructed solar illumination and is oriented in the same direction as the pyrolytic graphite covered photodiode. The short-circuit current from the photodiodes is measured and either sent to an onboard data logger, or transmitted to a receiving station on Earth. By comparison of the short-circuit currents from the fluence-measuring photodiode and the reference photodiode, one can compute the accumulated atomic oxygen fluence arriving in the direction that the fluence monitor is pointing. The device produces a signal that is linear with atomic oxygen fluence using a material whose atomic oxygen erosion yield has been measured over a period of several years in low-Earth orbit.

Banks, Bruce A.↗

Space Science Payloads Optical Properties Monitor (OPM) Mission Flight Anomalies Thermal Analyses

The OPM was the first space payload that measured in-situ the optical properties of materials and had data telemetered to ground. The OPM was EVA mounted to the Mir Docking Module for an eight-month stay where flight samples were exposed to the Mir induced and natural environments. The OPM was comprised of three optical instruments; a total hemispherical spectral reflectometer, a vacuum ultraviolet spectrometer, and a total integrated scatterometer. There were also three environmental monitors; an atomic oxygen monitor, solar and infrared radiometers, and two temperature-controlled quartz crystal microbalances (to monitor contamination). Measurements were performed weekly and data telemetered to ground through the Mir data system. This paper will describe the OPM thermal control design and how the thermal math models were used to analyze anomalies which occurred during the space flight mission.

Schmitz, Craig P.↗

An Optical Oxygen Sensor for Long-Term Continuous Monitoring of Dissolved Oxygen in Perfused Bioreactors

For long-term growth of man1ITlalian cells in perfused bioreactors, it is essential to monitor the concentration of dissolved oxygen (DO) present in the culture medium to quantitate and control level of DO. Continuous measurement of the amount of DO in the cell culture medium in-line under sterile conditions in NASA's perfused bioreactor requires that the oxygen sensor provide increased sensitivity and be sterilizable and nontoxic. Additionally, long-term cell culture experiments require that the calibration be maintained several weeks or months. Although there are a number of sensors for dissolved oxygen on the market and under development elsewhere, very few meet these stringent conditions. An optical oxygen sensor (BOXY) based on dynamic fluorescent quenching and a pulsed blue LED light source was developed in our laboratory to address these requirements. Tris( 4,7 -diphenyl-l, 1 O-phenanthroline )ruthenium(II) chloride is employed as the fluorescent dye indicator. The sensing element consists of a glass capillary (OD 4.0 mm; ID 2.0 mm) coated internally with a thin layer of the fluorescent dye in silicone matrix and overlayed with a black shielding layer. Irradiation of the sensing element with blue light (blue LED with emission maximum at 475 nm) generates a red fluorescence centered at 626 nm. The fluorescence intensity is correlated to the concentration of DO present in the culture medium, following the modified non-linear Stern-Volmer equation. By using a pulsed irradiating light source, the problem of dye-bleaching, which is often encountered in long-term continuous measurements of tIns type, 'is minimized. To date we achieved sensor resolution of 0.3 mmHg at 50 mmHg p02, and 0.6 mmHg at 100 mmHg p02, with a response time of about one minute. Calibration was accomplished in sterile phosphate-buffered saline with a blood-gas analyzer (BGA) measurement as reference. Stand-alone software was also developed to control the sensor and bioreactor as well as to acquire data. Two HOXY sensors with a single calibration were employed to continuously monitor the DO in GTSF-2 medium during a Baby Hamster Kidney (BHK-21) cell culture in a Rotating Wall Perfused Vessel (RWPV) bioreactor for 90 days. HOXY sensors were located at the inlet to and outlet from the bioreactor. One of the sensors was placed between an oxygenator and the inlet to the bioreactor. The dissolved oxygen concentrations determined by both sensors were compared with those measured regularly with the BGA reference. The cell culture was maintained for 110 days. Sensor output was found to correlate well with the BGA data throughout the experiment, where the DO of the medium ranged between 25 and 50 mmHg at the bioreactor outlet and 90-130 mmHg at the bioreactor inlet. Measuring DO with the HOXY sensors versus the BGA reference indicated bias values of -2 mmHg and -15 mmHg, and precision values of +/-3mmHg and +/-16 mmHg at the bioreactor inlet and outlet, respectively.

Gao, F. G.↗

In Situ Resource Utilization (ISRU) on the Moon: Moessbauer Spectroscopy as a Process Monitor for Oxygen Production

Essential consumables like oxygen must to be produced from materials on the lunar surface to enable a sustained, long-term presence of humans on the Moon. The Outpost Precursor for ISRU and Modular Architecture (OPTIMA) field test on Mauna Kea, Hawaii, facilitated by the Pacific International Space Center for Exploration Systems (PISCES) of the University of Hawaii at Hilo, was designed to test the implementation of three hardware concepts to extract oxygen from the lunar regolith: Precursor ISRU Lunar Oxygen Testbed (PILOT) developed by Lockheed Martin in Littleton, CO; Regolith & Environmental Science and Oxygen & Lunar Volatiles Extraction (RESOLVE) developed at the NASA Kennedy Space Center in Cape Canaveral, FL; and ROxygen developed at the NASA Johnson Space Center in Houston, TX. The three concepts differ in design, but all rely on the same general principle: hydrogen reduction of metal cations (primarily Fe2+) bonded to oxygen to metal (e.g., Fe0) with the production of water. The hydrogen source is residual hydrogen in the fuel tanks of lunar landers. Electrolysis of the water produces oxygen and hydrogen (which is recycled). We used the miniaturized M ssbauer spectrometer MIMOS II to quantify the yield of this process on the basis of the quantity of Fe0 produced. Iron M ssbauer spectroscopy identifies iron-bearing phases, determines iron oxidation states, and quantifies the distribution of iron between mineral phases and oxidation states. The oxygen yield can be calculated by quantitative measurements of the distribution of Fe among oxidation states in the regolith before and after hydrogen reduction. A M ssbauer spectrometer can also be used as a prospecting tool to select the optimum feedstock for the oxygen production plants (e.g., high total Fe content and easily reduced phases). As a demonstration, a MIMOS II backscatter spectrometer (SPESI, Germany) was mounted on the Cratos rover (NASA Glenn Research Center in Cleveland, OH), which is one of several rover concepts designed to excavate and transfer regolith to the stationary hydrogen reduction plants. Spaceflight versions of the MIMOS II are part of the instrument payloads of NASA s Mars Exploration Rovers and still operating five years after landing on the surface of the planet. MIMOS II was also selected for Phobos-Grunt, a Russian sample return mission to the martian moon Phobos scheduled to launch in 2009, and ESA s ExoMars rover, an exobiology mission scheduled to launch in 2013. An advanced version of the instrument is currently under development. A new detector system with a higher energy resolution will not only reduce the necessary measurement time considerably, but also allow the simultaneous acquisition of an X-ray fluorescence spectrum to determine the elemental composition of samples.

Morris, R.V.↗

Instrumentation systems for the Langley Research Center 8-foot high temperature tunnel

A description is presented of the 8-foot high-temperature tunnel, a Mach 7 blowdown-type facility in which methane is burned in air under pressure, with the resulting combustion products utilized as the test medium. The instrumentation environment and requirements are identified, and instrumentation design, including wiring, sensors, and data acquisition system are described. The design and installation of a fast oxygen monitoring system to maintain the partial pressure of oxygen at 21 percent in the tunnel test section is included. Also, the new data acquisition system hardware details and data-reduction capabilities are defined.

Walsh, James J., Jr.↗

Diagnostics Adapted for Heat-Treating Furnace Environment

Diagnostics developed for the in situ monitoring of rocket combustion environments were adapted for use in heat-treating furnaces. Simultaneous, in situ monitoring of the carbon monoxide, carbon dioxide, methane, water, and hydrogen concentrations in the endothermic gas of a heat-treating furnace were demonstrated under a Space Act Agreement between the NASA Lewis Research Center, the Heat Treating Network, and Akron Steel Treating Company. This endothermic gas, or "endogas," is produced in a catalytic process, where natural gas is "cracked" in the presence of air. Variations in the composition of the natural gas supplied lead to variations in the composition of the endothermic gas. These variations could lead to an unacceptable quality of steel products that are hardened through the carborization process that uses this gas. Conventional methods of monitoring the endogas include measuring the dew point of the gas and the oxygen concentration. From these data, the carbon monoxide content of the gas can be calculated. This carbon monoxide concentration creates the carbon potential needed for carburization. Several weak links are present in this approach. The oxygen monitor deteriorates over time, and the measurement might be inaccurate by 50 percent. Also, the chemistry equations, which are based on several assumptions, such as secondary species concentrations, provide only an approximate estimate of the carbon monoxide concentration. To address these weaknesses, we investigated a new method based on ordinary Raman spectroscopy, in which the carbon monoxide concentration is measured directly and in situ. This method measures the laser light scattered from the molecules. Each species interacts with the light and scatters the light at a different frequency. Spectral monitoring of the scattered light intensity at each molecular frequency of interest provides the species concentrations. One advantage over the conventional method is that several species can be monitored simultaneously. A second advantage is that the measurement is direct; there is no need to make assumptions, to filter the gas, or to calibrate the instrument. An instrument was designed consisting of a laser and a detection system within an enclosure, connected to an optical probe by fibers. For determining carbon monoxide concentration, the probe is mounted on the endothermic gas line, close to the generator. Optical fibers with a length of 150 ft have been used to transmit laser light from the instrument to the probe. There, the light is focused into the gas, and the scattered light is collected and transmitted back to the instrument where it is analyzed with a photomultiplier and lock-in amplifier. Laboratory tests have shown that with the current system the concentration of carbon monoxide, water, nitrogen, oxygen, and hydrogen in the air can be monitored with an accuracy of 1 percent. The concentration of carbon dioxide in the air can be monitored with an accuracy of 0.5 percent, and the concentration of methane with an accuracy of 0.2 percent. This instrument was taken to the Akron Steel Treating Plant, where field tests are in progress to verify the system capabilities. Planned developments are improving the accuracy, monitoring multiple locations, and reducing instrument size and cost.

Source record↗

System Report for the Optical Properties Monitor (OPM) Experiment

This systems report describes how the Optical Properties Monitor (OPM) experiment was developed. Pertinent design parameters are discussed, along with mission information and system requirements to successfully complete the mission. Environmental testing was performed on the OPM to certify it for spaceflight. This testing included vibration, thermal vacuum, electromagnetic interference and conductance, and toxicity tests. Instrument and monitor subsystem performances, including the reflectometer, vacuum ultraviolet, total integrated scatter, atomic oxygen monitor, irradiance monitor, and molecular contamination monitor during the mission are discussed. The OPM experiment was launched aboard the Space Shuttle on mission STS-81 in January 1997 and transferred to the Mir space station. An extravehicular activity (EVA) was performed in April 1997 to attach the OPM experiment to the outside of the Mir/Shuttle Docking Module for space environment exposure. The OPM conducted in situ measurements of a number of material samples. These data may be found in the OPM Science Report. OPM was retrieved during an EVA in January 1998 and was returned to Earth on board the Space Shuttle on mission STS-89.

Hummer, L.↗

Monitoring for neuroprotection. New technologies for the new millennium

Monitoring for neuroprotection, like surgery, has placed on emphasis on minimal or non-invasiveness. Monitoring of parameters that truly reflect the degree of injury to the nervous system is another goal. Thus, two themes for the coming decade in neuromonitoring will be: (1) less-invasive monitoring; and (2) parameters that more closely reflect the etiological factors in ischemic or other neuroinjury. In this paper, we review neuromonitoring techniques and devices that can be used readily in the operating room or intensive care unit setting. Those that require transport of the patient to a special facility (e.g., for computed tomography or magnetic resonance imaging/spectroscopy) and those that have been in standard practice for neuromonitoring (e.g., electrophysiological monitoring--EEG, evoked potentials) are not considered. The two techniques considered in detail are (1) continuous multiparameter local brain tissue monitoring with microprobes, and (2) non-invasive continuous local brain tissue oxygenation monitoring by near infrared spectroscopy. Both techniques have been cleared by the Food and Drug Administration (FDA) for clinical use. The rationale for their use, the nature of the devices, and clinical results to date are reviewed. It is expected that both techniques will gain wide acceptance during the coming decade; further advances in neuromonitoring that can be expected further into the twenty-first century are also discussed.

Review↗

Single Crystal Optical Fiber and Perovskite Oxide Sensing Materials for Gas Monitoring above 500 °C

A wide range of high-value applications, including power generation and chemical manufacturing, involve harsh chemical conditions and extreme temperatures. In this work, we discuss the pairing of single crystal optical fiber with optically responsive, high-temperature stable perovskite oxide materials for monitoring of oxidizing and reduction gas streams up to 1000 °C. Optical sensing will be presented for hydrogen and oxygen monitoring in this temperature regime. Strategies will be discussed for improving stability and eliminating drift via multi-wavelength detection. The application of spatially resolved interrogation techniques, such as optical time domain reflectometry (OTDR) will be addressed for these sensors.

Wuenschell, Jeffrey↗

Electromotive force measurements on cells involving beta-alumina solid electrolyte

Open circuit emf measurements have been made to demonstrate that a two-phase, polycrystalline mixture of beta- alumina and alpha-alumina could be used as a solid electrolyte in galvanic cells with reversible electrodes fixing oxygen or aluminum chemical potentials. These measurements indicate that such a two phase solid electrolyte can be used to monitor oxygen chemical potentials as low as that corresponding to Al, Al2O3 coexistence. The activity of Na2O in beta-alumina in coexistence with alpha-alumina was also determined by emf measurements.

Choudhury, N.↗

Electromotive force measurements on cells involving beta-alumina solid electrolyte

Open-circuit emf measurements have been made to demonstrate that a two-phase, polycrystalline mixture of beta-alumina and alpha-alumina could be used as a solid electrolyte in galvanic cells with reversible electrodes fixing oxygen or aluminum chemical potentials. These measurements indicate that such a two-phase solid electrolyte may be used to monitor oxygen chemical potentials as low as that corresponding to Al and Al2O3 coexistence (potentials of about 10 to the minus 47th power atm at 1000 K). The activity of Na2O in beta-alumina in coexistence with alpha-alumina was also determined by emf measurements.

Choudhury, N. S.↗

Continued Development of Compact Multi-Gas Monitor for Life Support Systems Control in Space

Miniature optic gas sensors (MOGS) based on luminescent materials have shown great potential as alternatives to NIR-based gas sensor systems for the Portable Life Support System (PLSS). The unique capability of MOGS for carbon dioxide and oxygen monitoring under wet conditions has been reported, as has the fast recovery of MOGS humidity sensors after long periods of being wet. Lower volume and power requirements are also potential advantages of MOGS over both traditional and advanced Non-Dispersive Infrared (NDIR) gas sensors, which have shown so far longer life than luminescent sensors. In this paper we present the most recent results in the development and analytical validation of a compact multi-gas sensor unit based on luminescent sensors for the PLSS. Results of extensive testing are presented, including studies conducted at Intelligent Optical Systems laboratories, a United Technology Corporation Aerospace Systems (UTAS) laboratory, and a Johnson Space Center laboratory. The potential of this sensor technology for gas monitoring in PLSSs and other life support systems and the advantages and limitations found through detailed sensor validation are discussed.

Delgado, Jesus↗

Continued Development of Compact Multi-Gas Monitor for Life Support Systems Control in Space

Miniature optical gas sensors based on luminescent materials have shown great potential as alternatives to NIR-based gas sensor systems for the Portable Life Support System (PLSS). The unique capability of luminescent sensors for carbon dioxide and oxygen monitoring under wet conditions has been reported, as has the fast recovery of humidity sensors after long periods of being wet. Lower volume and power requirements are also potential advantages over both traditional and advanced non-dispersive infrared (NDIR) gas sensors, which have so far shown longer life than luminescent sensors. In this paper we present the most recent results in the development and analytical validation of a compact multi-gas sensor unit based on luminescent sensors for the PLSS. Results of extensive testing are presented, including studies conducted in Intelligent Optical Systems laboratories, a United Technologies Corporation Aerospace Systems (UTC) laboratory, and a Johnson Space Center laboratory. The potential of this sensor technology for gas monitoring in PLSSs and other life support systems, and the advantages and limitations found through detailed sensor validation are discussed.

Delgado-Alonso, Jesus↗