Search NASA⌕ Search

SEARCH · Search NASA

Results for “packer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Oil Recovery System

A Downhole Steam Generation System brings oil up from deep reservoirs. The system, developed by Foster-Miller Associates consists of a steam generator, a "packer" that keeps the steam from leaking up the wellbore, and tube string that supplies air, fuel, water and hydraulics to the generator and packer; all are encased in a standard seven-inch well casing. Downhole means that the steam generator is located far down the well casing rather than on the surface. This design is more efficient than surface generated steam. A COSMIC (Computer Software Management and Information Center) program aided in the design.

Source record↗

Heating production fluids in a wellbore

A method for heating a production fluid in a wellbore. The method can include heating, using a packer fluid, a working fluid flowing through a first medium disposed in a first section of the wellbore, where the first medium transfers heat from the packer fluid to the working fluid. The method can also include circulating the working fluid into a second section of the wellbore through a second medium, where the second medium transfers heat from the working fluid to the production fluid. The method can further include returning the working fluid to the first section of the wellbore through the first medium.

02 PETROLEUM↗

Utah FORGE 2439: Well 16B(78)-32 Field-Test Data from Mini-Frac Tests

This submittal includes the field-test data collected during stress tests conducted in the Utah FORGE 16B(78)-32 wellbore to measure/characterize the stresses in the geothermal reservoir. The type of stress test performed is referred to as a mini-frac test or a micro-frac test. The test is a hydraulic fracture test that involves injecting a small volume of water into a short interval of the reservoir that is isolated by a straddle packer to create a fracture. The test provides information about the minimum and maximum horizontal stress at the test depths. A total of seven mini-frac tests were performed within the upper (vertical or nearly vertical) section of the 9-5/8-inch diameter uncased wellbore, between depths of 5,202 ft MD [5,202 ft TVD] and 5,980 ft MD [5966.18 ft TVD]. Two types of data were generated as part of the mini-frac tests. The first type of data is time-series data for each mini-frac test (e.g., injection-rate, test-interval pressure), and are contained in the "Mini-Frac Test Data.zip" file below. The second type is geophysical log data, attached below in the "Geophysical Logs.zip" file. Here, two types of image logs and acoustic logs were obtained before and after the mini-frac tests to examine each test depth for visual evidence of induced fracture(s) and to measure the azimuth (orientation) of any observed fractures. The attached Readme file includes the test depth information and contents of each data file included here. Analysis of the field-test data was conducted and is documented in the attached report below.

15 GEOTHERMAL ENERGY↗

WE-EF-BRA-03: Catheter- Free Ablation with External Photon Radiation: Treatment Planning, Delivery Considerations, and Correlation of Effects with Delivered Dose

Purpose: To plan, target, and calculate delivered dose in atrioventricular node (AVN) ablation with volume-modulated arc therapy (VMAT) in an intact porcine model. Methods: Seven pigs underwent AVN irradiation, with prescription doses ranging between 25 and 55Gy in a single fraction. Cardiac CT scans were acquired at expiration. Two physicians contoured AVN targets on 10 phases, providing estimates of target motion and inter-physician variability. Treatment planning was conducted on a static phase-averaged CT. The volume designated to receive prescription dose covered the full extent of AVN cardiac motion, expanded by 4mm for setup uncertainty. Optimization limited doses to risk structures according to single-fraction tumor treatment protocols. Orthogonal kV images were used to align bony anatomy at time of treatment. Localization was further refined with respiratory-gated cone-beam CT, and range of cardiac motion was verified under fluoroscopy. Beam delivery was respiratory-gated for expiration with a mean efficiency of 60%. Deformable registration of the 10 cardiac CT phases was used to calculate actual delivered dose for comparison to electro-anatomical and visually evident lesions. Results: The mean [minimum,maximum] amplitude of AVN cardiac motion was LR 2.9 [1.7,3.9]mm, AP 6.6 [4.4,10.4]mm, and SI 5.6 [2.0,9.9]mm. Incorporating cardiac motion into the dose calculation showed the volume receiving full dose was 40–80% of the volume indicated on the static planning image, although the contoured AVN target received full dose in all animals. Initial results suggest the dimensions of the electro-anatomical lesion are correlated with the 40Gy isodose volume. Conclusion: Image-guidance techniques allow for accurate and precise delivery of VMAT for catheter-free arrhythmia ablation. An arsenal of advanced radiation planning, dose optimization, and image-guided delivery techniques was employed to assess and mitigate effects of cardiac and respiratory motion. Feasibility of delivery to the pulmonary veins and left ventricular myocardium will be investigated in future studies. D. Packer Disclosures: Abiomed, Biosense Webster, Inc., Boston Scientific Corp., CardioFocus, Inc., Johnson and Johnson, Excerpta Medica, Ortho-McNeil-Jannsen, Sanofi Aventis, CardioInsight Technologies, InfoBionic, SIEMENS, Medtronic, Inc., CardioDx, Inc., CardioInsight Technologies, FoxP2 Medica, Mediasphere Medical, Wiley-Blackwell, St. Jude Medical, Endosense, Thermedical, EP Advocate LLC, Hansen Medical, American Heart Association, EpiEP, NIH.

60 APPLIED LIFE SCIENCES↗

Utah FORGE 1-2409: PetroQuip Energy Services Zonal Isolation Solution for Geothermal Wells - 2024 Annual Workshop Presentation

This is a presentation on the Zonal Isolation Solution for Geothermal Wells by PetroQuip Energy Services, presented by Robert Coon. This video slide presentation discusses the proposed design and development of a multi-stage system consisting of an Open-Hole Packer (OHP), a Locking Bridge Plug (LBP), and a corresponding Locating Profile (LP). This presentation was featured in the Utah FORGE R&D Annual Workshop on August 14, 2024.

15 GEOTHERMAL ENERGY↗

SPI Conformance Gel Applications in Geothermal Zonal Isolation

Zonal isolation in geothermal injection and producing wells is important while drilling the wells when highly fractured geothermal zones are encountered and there is a need to keep the fluids from interfering with the drilling operation. Department of Energy’s (DOE) Energy Efficiency and Renewable Energy (EERE) objectives are to advance technologies to make it more cost effective to develop, produce, and monitor geothermal reservoirs and produce geothermal energy. Thus, zonal isolation is critical to well cost, reservoir evaluation and operations. Traditional cementing off of the lost circulation or thief zones during drilling is often done to stem the drilling mud losses. This is an expensive and generally unsuccessful technique losing the potential of the remaining fracture system. Selective placement of strong SPI gels into only the offending fractures can maintain and even improve operational efficiency and resource life. The SPI gel system is a unique silicate based gel system that offers a promising solution to thief zones and conformance problems with water and CO2 floods and potentially geothermal operations. This gel system remains a low viscosity fluid until an initiator (either internal such as an additive or external such as CO2) triggers gelation. This is a clear improvement over current mechanical methods of using packers, plugs, liners and cementing technologies that often severely damage the highly fractured area that is isolated. In the SPI gels, the initiator sets up the fluid into a water-like (not a precipitate) gel and when the isolated zone needs to be reopened, the SPI gel may be removed with an alkaline solution without formation damage occurring. In addition, the SPI gel in commercial quantities is expected to be less expensive than competing mechanical systems and has unique deep placement possibilities. This project seeks to improve upon the SPI gel integrity by modifying the various components to impart temperature stability for use in geothermal.

15 GEOTHERMAL ENERGY↗

In situ observations on the coupling between hydraulic diffusivity and displacements during fault reactivation in shales

Key questions in fault reactivation in shales relate to the potential for enhanced fluid transport through previously low-permeability aseismic formations. Here, we explore the behavior of a 20 m long N0-to-170°, 75-to-80°W fault in shales that is critically stressed under a strike-slip regime (σ 1 = 4 ± 2 MPa, horizontal and N162° ± 15°E, σ 2 = 3.8 ± 0.4 MPa and σ 3 = 2.1 ± 1 MPa, respectively 7-8° inclined from vertical and horizontal and N72°). The fault was reactivated by fluid pressurization in a borehole using a straddle packer system isolating a 2.4 m long injection chamber oriented-subnormal to the fault surface at a depth of 250 m. A three-dimensional displacement sensor attached across the fault allowed monitoring fault movements, injection pressure and flow rate. Pressurization induced a hydraulic diffusivity increase from ~2 × 10 -9 to ~10 3 m 2 s -1 associated with a complex three-dimensional fault movement. The shear (x-, z-) and fault-normal (y-) components (U x , U y , and U z ) = (44.0 × 10 -6 m, 10.5 × 10 -6 m, and 20.0 × 10 -6 m) are characterized by much larger shear displacements than the normal opening. Numerical analyses of the experiment show that the fault permeability evolution is controlled by the fault reactivation in shear related to Coulomb failure. The large additional fault hydraulic aperture for fluid flow is not reflected in the total normal displacement that showed a small partly contractile component. This suggests that complex dilatant effects estimated to occur in a plurimeter radius around the injection source affect the flow and slipping patch geometries during fault rupture, controlling the initial slow slip and the strong back slip of the fault following depressurization.

58 GEOSCIENCES↗

Atmospheric tracer monitoring and surface plume development at the ZERT pilot test in Bozeman, Montana, USA

A controlled release of CO 2 was conducted at a field site in Bozeman, Montana, USA in July of 2008 in a multi-laboratory study of near surface transport and detection technologies. The development of a subsurface CO 2 plume near the middle packer section of the horizontal release was studied using soil-gas and surface flux measurements of CO 2 . A perfluorocarbon tracer was added to the CO 2 released from this section of the horizontal well, and the development of atmospheric plumes of the tracer was studied under various meteorological conditions using horizontal and vertical grids of monitors containing sorbent material to collect the tracer. This study demonstrated the feasibility of using remote sensing for the ultra low level detection of atmospheric plumes of tracers as means to monitor the near surface leakage of sequestered CO 2 .

54 ENVIRONMENTAL SCIENCES↗

Using in-situ strain measurements to evaluate the accuracy of stress estimation procedures from fracture injection/shut-in tests

Fracture injection/shut-in tests are commonly used to measure the state of stress. Injection creates a hydraulic fracture (or in some cases, opens a preexisting fracture), and then the pressure after shut-in is monitored to identify fracture closure. Different interpretation procedures have been proposed for estimating closure, and the procedures sometimes yield significantly different results. In this study, direct, in-situ strain measurements are used to observe fracture reopening and closure. The tests were performed as part of the EGS Collab project, a mesoscale project performed at 1.25 and 1.5 km depth at the Sanford Underground Research Facility. The tests were instrumented with the SIMFIP tool, a double-packer probe with a high-resolution three-dimensional borehole displacement sensor. The measurements provide a direct observation of the fracture closure signature, enabling a high-fidelity estimate of the fracture closure stress (ie, the normal stress on the fracture). In two of the four tests, injection created an opening mode fracture, and so the closure stress can be interpreted as the minimum principal stress. In the other two tests, injection probably opened preexisting natural fractures, and so the closure stress can be interpreted as the normal stress on the fractures. The strain measurements are compared against different proposed methods for estimating closure stress from pressure transients. The shut-in transients are analyzed with two techniques that are widely used in the field of petroleum engineering – the ‘tangent’ method and the ‘compliance’ method. In three of the four tests, the tangent method significantly underestimates the closure stress. The compliance method is reasonably accurate in all four tests. Closure stress is also interpreted using two other commonly-used methods – ‘first deviation from linearity’ and the method of Hayashi and Haimson. In comparison with the SIMFIP data, these methods tend to overestimate the closure stress, evidently because they identify closure from early-time transient effects, such as near-wellbore tortuosity. In two of the tests, microseismic imaging provides an independent estimate of the size of the fracture created by injection. When combined with a simple mass balance calculation, the SIMFIP stress measurements yield predictions of fracture size that are reasonably consistent with the estimates from microseismic. In conclusion, the calculations imply an apparent fracture toughness 2-3x higher than typical laboratory-derived values.

58 GEOSCIENCES↗

A Field Proof-of-Concept of Aquifer Imaging Using 3-D Transient Hydraulic Tomography with Modular, Temporarily-Emplaced Equipment

Hydraulic tomography is a field scale aquifer characterization method capable of estimating 3-D heterogeneous parameter distributions, and is directly sensitive to hydraulic conductivity (K), thus providing a useful data source for improving flow and transport models. We present results from a proof-of-concept field and modeling study in which we apply 3-D transient hydraulic tomography (3DTHT) to the relatively high-K and moderately heterogeneous unconfined aquifer at the Boise Hydrogeophysical Research Site. Short-duration (20 min) partially penetrating pumping tests, for which observed responses do not reach steady state, are used as the aquifer stimulation. To collect field data, we utilize a system of temporarily emplaced packer equipment to isolate multiple discrete intervals in boreholes. To analyze the data, we utilize MODFLOW combined with geostatistical inversion code based on the quasilinear approach of Kitanidis (1995). This combination of practical software allows inversion of large datasets (>250 drawdown curves, and almost 1000 individual data points) and estimation of K at >100,000 locations; reasonable runtimes are obtained using a single multicore computer with 12 GB of RAM. The K heterogeneity results from 3DTHT are cross-validated against K characterization from a large set of partially penetrating slug tests, and found to be quite consistent. The use of portable, modular equipment for field implementation means that 3DTHT data collection can be performed (including mobilization/demobilization) within a matter of days. Likewise, use of a practical, efficient and scalable numerical modeling and inversion strategy means that computational effort is drastically reduced, such that 3-D aquifer property distributions can be estimated quickly.

Environmental Molecular Sciences Laboratory↗

Hydraulic Modeling of Induced and Propagated Fractures: Analysis of Flow and Pressure Data From Hydromechanical Experiments in the COSC-1 Deep Borehole in Crystalline Rock Near Åre, Sweden

To characterize the coupled hydromechanical behavior of rock fractures, the step-rate injection method for fracture in-situ properties (SIMFIP) was conducted with a specialized downhole probe developed by Guglielmi et.al. In June 2019, a field campaign was carried out near Åre, Sweden, where the SIMFIP probe was applied in the Collisional Orogeny in the Scandinavian Caledonides-1 scientific borehole to understand the dynamics of injection-induced fracture initiation, fracture opening, and shearing due to water injection-withdrawal in a borehole interval isolated by two packers. Three intervals were investigated at ~500 m depth: (a) an unfractured section (intact rock), (b) a section with non-conductive fractures, and (c) a section with hydraulically conductive fractures. Pressure, injection flow rate, and borehole wall displacement were simultaneously measured during the tests. In the present study, the geometry of the induced fracture and deformation of existing fractures at different time stages of the tests are determined based on a hydrologic model by using the measured pressure and flow data during each time stage of the experiment. A numerical model for the fluid flow within the fracture and the packed-off borehole interval is implemented within COMSOL Multiphysics. By matching model simulations with observed data for all three sections, estimates of the induced and propagated fractures' radius and aperture at successive time stages have been obtained in each case. We could also determine the non-linear relationship between fracture aperture and pressure for values above fracture opening pressures. The model results provide insights for the understanding of pressure-induced fracture initiation and propagation in crystalline rock.

58 GEOSCIENCES↗

WellSTIC: A Cost-Effective Sensor for Performing Point Dilution Tests to Measure Groundwater Velocity in Shallow Aquifers

Many individual measurement points are required to characterize groundwater velocity within an aquifer. Groundwater velocity is most commonly measured using a network of >5 cm diameter monitoring wells, which, if not already present at a site, are expensive and labor-intensive to install. Drive-point piezometers—simple, cost-effective wells that can be installed by hand—are a common tool for sampling groundwater in shallow, alluvial aquifers, but most groundwater velocity measurement techniques require equipment that is too large for these narrow (usually <2 cm inside diameter) piezometers. In this technical note, we introduce a low-cost sensor and well packer system (<$90 USD) for performing point dilution tests in narrow piezometers. Field data show that the magnitude of groundwater velocity measured with this technique agrees with velocities computed from natural gradient tracer tests. Additionally, with proper calibration, these sensors can be used to continuously monitor in-well specific conductance, either during inter-well tracer tests with saline tracers or for water quality monitoring. Finally, this system is a viable tool for rapid assessment of the magnitude of groundwater velocity in shallow aquifers.

54 ENVIRONMENTAL SCIENCES↗

4D Electrical Resistivity Imaging of Stress Perturbations Induced During High–Pressure Shear Stimulation Tests

Fluid flow through fractured media is typically governed by the distribution of fracture apertures, which are in turn governed by stress. Consequently, understanding subsurface stress is critical for understanding and predicting subsurface fluid flow. Although laboratory–scale studies have established a sensitive relationship between effective stress and bulk electrical conductivity in crystalline rock, that relationship has not been extensively leveraged to monitor stress evolution at the field scale using electrical or electromagnetic geophysical monitoring approaches. In this paper we demonstrate the use time–lapse 3–dimensional (4D) electrical resistivity tomography to image perturbations in the stress field generated by pressurized borehole packers deployed during shear–stimulation attempts in a 1.25 km deep metamorphic crystalline rock formation.

58 GEOSCIENCES↗

River-Induced Flow Dynamics in Long-Screen Wells and Impact on Aqueous Samples

Previously published field investigations and modeling studies have demonstrated the potential for sample bias associated with vertical wellbore flow in conventional monitoring wells constructed with long-screened intervals. This paper builds on the existing body of literature by 1) demonstrating the utility of continuous (i.e., hourly measurements for ~ one month) ambient wellbore flow monitoring and 2) presenting results from a field experiment where relatively large wellbore flows (up to 4 LPM) were induced by aquifer hydrodynamics associated with a fluctuating river boundary located approximately 250 m from the test well. The observed vertical wellbore flows were strongly correlated with fluctuations in river stage, alternating between upward and downward flow throughout the monitoring period in response to changes in river stage. Continuous monitoring of ambient wellbore flows using an Electromagnetic Borehole Flowmeter (EBF) allowed these effects to be evaluated in concert with continuously monitored river-stage elevations (hourly) and aqueous uranium concentrations (daily) in a long-screen well and an adjacent multi-level well cluster. This study demonstrates that when contaminant concentrations within the aquifer vary significantly over the depth interval interrogated, even for screen lengths as small as 7.6 m, river-induced vertical wellbore flow can result in variations in measured concentration that nearly encompass the full range of variation in aquifer contaminant concentration with depth. An approach to mitigate these effects based on increasing hydraulic resistance within the wellbore by installing an inflatable packer was evaluated and was demonstrated to reduce vertical wellbore flows.

54 ENVIRONMENTAL SCIENCES↗

Virtual Machine Builder

Virtual Machine Builder is a graphical user interface for use and modification of virtual machine templates using Hashi Corp packer to perform virtual machine creation.

Nielsen, Roy↗

ClockworkVMs

Graphical user interface for use and modification of virtual machine templates using Hashi Corp packer to perform virtual machine creation.

Nielsen, Roy↗

Applications of Geothermally-Produced Colloidal Silica in Reservoir Management - Smart Gels

In enhanced geothermal systems (EGS) the reservoir permeability is often enhanced or created using hydraulic fracturing. In hydraulic fracturing, high fluid pressures are applied to confined zones in the subsurface usually using packers to fracture the host rock. This enhances rock permeability and therefore conductive heat transfer to the circulating geothermal fluid (e.g. water or supercritical carbon dioxide). The ultimate goal is to increase or improve the thermal energy production from the subsurface by either optimal designs of injection and production wells or by altering the fracture permeability to create different zones of circulation that can be exploited in geothermal heat extraction. Moreover, hydraulic fracturing can lead to the creation of undesirable short-circuits or fast flow-paths between the injection and extraction wells leading to a short thermal residence time, low heat recovery, and thus a short-life of the EGS. A potential remedy to these problems is to deploy a cementing (blocking, diverting) agent to minimize short-cuts and/or create new circulation cells for heat extraction. A potential diverting agent is the colloidal silica by-product that can be co-produced from geothermal fluids. Silica gels are abundant in various surface and subsurface applications, yet they have not been evaluated for EGS applications. In this study we are investigating the benefits of silica gel deployment on thermal response of an EGS, either by blocking short-circuiting undesirable pathways as a result of diverting the geofluid to other fractures; or creating, within fractures, new circulation cells for harvesting heat through newly active surface area contact. A significant advantage of colloidal silica is that it can be co-produced from geothermal fluids using an inexpensive membrane-based separation technology that was developed previously using DOE-GTP funding. This co-produced silica has properties that potentially make it useful as a fluid diversion agent for subsurface applications. Colloidal silica solutions exist as low-viscosity fluids during their “induction period” but then undergo a rapid increase in viscosity (gelation) to form a solid gel. The length of the induction period can be manipulated by varying the properties of the solution, such as silica concentration and colloid size. We believe it is possible to produce colloidal silica gels suitable for use as diverting agents for blocking undesirable fast-paths which result in short-circuiting the EGS once hydraulic fracturing has been deployed. In addition, the gels could be used in conventional geothermal fields to increase overall energy recovery by modifying flow.

15 GEOTHERMAL ENERGY↗

EGS Collab Experiment 2: Hydraulic Pressure Test Results

The EGS Collab experiment 2 was focused on testing shear stimulation techniques. Shear stimulation, in this case, means using hydraulic pressure to cause shear slip on preexisting fracture or fault planes such that the hydraulic conductivity of the fracture or fault increases. The concept is to create a percolating network of permeable fractures by enhancing the permeability of a primarily preexisting network of fractures. To test this concept the hydraulic pressures for experiment 2 were kept below the the estimated magnitude of the least compressive principal stress based on a set of stress measurements in nearby well TV4100. All tests for experiment 2 were performed by applying hydraulic pressure to well E2-TC. Subsequent stimulations in both E2-TC and E2-TU where the injection pressure was increased above the least compressive principal stress are considered part of experiment 3, which is documented separately. The data are organized in directories labeled by the depth range isolated between packers.

15 GEOTHERMAL ENERGY↗