Search NASA⌕ Search

SEARCH · Search NASA

Results for “parameter compensation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Optimal acceleration of ions by laser pulses with a sharp leading edge

We consider acceleration of ions through the interaction of a laser pulse with a sharp leading edge with nanofilms. At sufficiently large amplitude of the pulse, all the electrons can be expelled from the film, which provides an effective regime of ion acceleration. Limiting the maximum energy of ions can result from the longitudinal reverse motion of electrons to the initial position and by the transverse motion of electrons along the nanofilm surface, which causes the ion charge compensation. The characteristic parameters of the dynamics of ions and electrons in the system are analytically evaluated, which agree well with the results of twodimensional numerical simulations by the particle-in-cell method. Optimisation of the acceleration process by using the analytical estimates makes it possible to select the optimal parameters of the laser pulse and nanofilm. Numerical simulation of ion acceleration at these parameters shows that the maximum energy of ions can be substantially increased.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Disentangling the hydrological and hydraulic controls on streamflow variability in Energy Exascale Earth System Model (E3SM) V2 – a case study in the Pantanal region

Abstract. Streamflow variability plays a crucial role in shaping the dynamics and sustainability of Earth's ecosystems, which can be simulated and projected by a river routing model coupled with a land surface model. However, the simulation of streamflow at large scales is subject to considerable uncertainties, primarily arising from two related processes: runoff generation (hydrological process) and river routing (hydraulic process). While both processes have impacts on streamflow variability, previous studies only calibrated one of the two processes to reduce biases in the simulated streamflow. Calibration focusing only on one process can result in unrealistic parameter values to compensate for the bias resulting from the other process; thus other water-related variables remain poorly simulated. In this study, we performed several experiments with the land and river components of the Energy Exascale Earth System Model (E3SM) over the Pantanal region to disentangle the hydrological and hydraulic controls on streamflow variability in coupled land–river simulations. Our results show that the generation of subsurface runoff is the most important factor for streamflow variability contributed by the runoff generation process, while floodplain storage effect and main-channel roughness have significant impacts on streamflow variability through the river routing process. We further propose a two-step procedure to robustly calibrate the two processes together. The impacts of runoff generation and river routing on streamflow are appropriately addressed with the two-step calibration, which may be adopted by developers of land surface and earth system models to improve the modeling of streamflow.

54 ENVIRONMENTAL SCIENCES↗

Simulations of Head-On Beam-Beam Compensation at RHIC and LHC

Electron lenses are proposed as a way to mitigate head-on beam-beam effects for RHIC and LHC upgrades. An extensive effort was put together within the US LARP in order to develop numerical simulations of beam-beam effects in the presence of electron lenses. In this report the results of numerical beam-beam simulations for RHIC and LHC are presented. The effect of electron lenses is demonstrated and sensitivity of beam-beam compensation to machine parameters is discussed.

43 PARTICLE ACCELERATORS↗

Influence of compensator thickness, field size, and off-axis distance on the effective attenuation coefficient of a cerrobend compensator for intensity-modulated radiation therapy

Intensity-modulated radiation therapy (IMRT) can be performed by using compensators. To make a compensator for an IMRT practice, it is required to calculate the effective attenuation coefficient (μ{sub eff}) of its material, which is affected by various factors. We studied the effect of the variation of the most important factors on the calculation of the μ{sub eff} of the cerrobend compensator for 6-MV photon beams, including the field size, compensator thickness, and off-axis distance. Experimental measurements were carried out at 100 cm source-to-surface distance and 10 cm depth for the 6-MV photon beams of an Elekta linac using various field size, compensator thickness, and off-axis settings. The field sizes investigated ranged from 4 × 4 to 25 × 25 cm{sup 2} and the cerrobend compensator thicknesses from 0.5–6 cm. For a fixed compensator thickness, variation of the μ{sub eff} with the field size ranged from 3.7–6.8%, with the highest value attributed to the largest compensator thickness. At the reference field size of 10 × 10 cm{sup 2}, the μ{sub eff} varied by 16.5% when the compensator thickness was increased from 0.5–6 cm. However, the variation of the μ{sub eff} with the off-axis distance was only 0.99% at this field size, whereas for the largest field size, it was more significant. Our results indicated that the compensator thickness and field size have the most significant effect on the calculation of the compensator μ{sub eff} for the 6-MV photon beam. Therefore, it is recommended to consider these parameters when calculating the compensator thickness for an IMRT practice designed for these beams. The off-axis distance had a significant effect on the calculation of the μ{sub eff} only for the largest field size. Hence, it is recommended to consider the effect of this parameter only for field sizes larger than 25 × 25 cm{sup 2}.

07 ISOTOPE AND RADIATION SOURCES↗

Compensation of Missed Fractions Without Knowledge of Radiobiological Parameters

The purpose of this work was to develop simple formulas that can be used to estimate the biologic effect of missed radiotherapy fractions independently of radiobiological parameters. This is achieved by expressing the limits in biologically effective dose for very low or very high radiobiological parameter ratios. Worked examples are given.

61 RADIATION PROTECTION AND DOSIMETRY↗

A novel method for experimental characterization of large-angle scattered particles in scanned carbon-ion therapy

Purpose: It is essential to consider large-angle scattered particles in dose calculation models for therapeutic carbon-ion beams. However, it is difficult to measure the small dose contribution from large-angle scattered particles. In this paper, the authors present a novel method to derive the parameters describing large-angle scattered particles from the measured results. Methods: The authors developed a new parallel-plate ionization chamber consisting of concentric electrodes. Since the sensitive volume of each channel is increased linearly with this type, it is possible to efficiently and easily detect small contributions from the large-angle scattered particles. The parameters describing the large-angle scattered particles were derived from pencil beam dose distribution in water measured with the new ionization chamber. To evaluate the validity of this method, the correction for the field-size dependence of the doses, “predicted-dose scaling factor,” was calculated with the new parameters. Results: The predicted-dose scaling factor calculated with the new parameters was compared with the existing one. The difference between the new correction factor and the existing one was 1.3%. For target volumes of different sizes, the calculated dose distribution with the new parameters was in good agreement with the measured one. Conclusions: Parameters describing the large-angle scattered particles can be efficiently and rapidly determined using the new ionization chamber. The authors confirmed that the field-size dependence of the doses could be compensated for by the new parameters. This method makes it possible to easily derive the parameters describing the large-angle scattered particles, while maintaining the dose calculation accuracy.

61 RADIATION PROTECTION AND DOSIMETRY↗

SiC MOSFET Based Single Phase Active Boost Rectifier with Power Factor Correction for Wireless Power Transfer Applications

Wireless Power Transfer (WPT) technology is a novel research area in the charging technology that bridges the utility and the automotive industries. There are various solutions that are currently being evaluated by several research teams to find the most efficient way to manage the power flow from the grid to the vehicle energy storage system. There are different control parameters that can be utilized to compensate for the change in the impedance due to variable parameters such as battery state-of-charge, coupling factor, and coil misalignment. This paper presents the implementation of an active front-end rectifier on the grid side for power factor control and voltage boost capability for load power regulation. The proposed SiC MOSFET based single phase active front end rectifier with PFC resulted in >97% efficiency at 137mm air-gap and >95% efficiency at 160mm air-gap.

active rectifier↗

Thermodynamic data of Ba{sub 0.6}Sr{sub 0.4}Co{sub 0.8}Fe{sub 0.2}O{sub 3−δ} SOFC cathode material

Graphical abstract: Partial molar energy of oxygen dissolution (ΔG{sup −}{sub O{sub 2}}) and equilibrium partial pressure of oxygen (log⁡p{sub O{sub 2}}) of perovskite material with the composition Ba{sub 0.6}Sr{sub 0.4}Co{sub 0.8}Fe{sub 0.2}O{sub 3−δ} as a function of temperature. - Highlights: • We report relevant data for thermodynamic stability of Ba{sub 0.6}Sr{sub 0.4}Co{sub 0.8}Fe{sub 0.2}O{sub 3−δ} perovskite compound. • Temperature of structural transformations related to the charge compensation of the material system is evidenced. • The results are discussed based on the properties-defect structure relationship. - Abstract: The compound Ba{sub 0.6}Sr{sub 0.4}Co{sub 0.8}Fe{sub 0.2}O{sub 3−δ} with perovskite structure has been studied focusing mainly on the thermodynamic stability in correlation to the change in the oxygen stoichiometry. The thermochemical behavior has been investigated from room temperature to 1300 K by thermal gravimetry and differential thermal analysis in air and by calorimetry in scanning mode in Argon. The temperature dependence of enthalpy (ΔH{sup T}{sub 298}) in the temperature range of 300–900 K was measured by drop calorimetry. Thermodynamic properties represented by the relative partial molar free energies, enthalpies and entropies of oxygen dissolution in the perovskite phase, as well as the equilibrium partial pressures of oxygen have been obtained in the temperature range of 823–1273 K using solid electrolyte electrochemical cells (EMF). The influence of the oxygen stoichiometry on the thermodynamic properties was examined using a coulometric titration technique coupled with EMF measurements. The results are discussed based on the strong correlation between the energetic parameters and the charge compensation of the material system.

36 MATERIALS SCIENCE↗

Operational Studies of the 10 keV Electron Storage Ring UMER

The University of Maryland Electron Ring (UMER) is now operational. UMER can operate with currents from 0.6 mA to 100 mA, ranging from the emittance dominated to the heavily space charge dominated regimes. Multiple turns have been achieved at all operating currents, from 250 turns at 0.6 mA to about 12 turns at 100 mA, but not yet optimized for operation above 25 mA. Machine development in the past year has been on understanding the single particle behavior in order to establish a strong basis for studying the effects of space charge. The effect of the earth's field has been studied and compensation implemented. Basic machine parameters such as the tune, equilibrium orbit, chromaticity and dispersion have been measured over a range of currents. We report here on these measurements and corresponding simulations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

On spectroscopy for a whole Abelian model

Postulated on the whole meaning a whole abelian gauge symmetry is being introduced. Various physical areas as complexity, statistical mechanics, quantum mechanics are partially supporting this approach where the whole is at origin. However, the reductionist crisis given by quark confinement definitely sustains this insight. It says that fundamental parts can not be seen isolatedely. Consequently, there is an experimental situation where the parts should be substituted by something more. This makes us to look for writing the wholeness principle under gauge theory. For this, one reinterprets the gauge parameter where instead of compensating fields it is organizing a systemic gauge symmetry. Now, it introduces a fields set {l_brace}A{sub {mu}I}{r_brace} rotating under a common gauge symmetry. Thus, given a fields collection {l_brace}A{sub {mu}I}{r_brace} as origin, the effort at this work is to investigate on its spectroscopy. Analyze for the abelian case the correspondent involved quanta. Understand that for a whole model diversity replaces elementarity. Derive the associated quantum numbers as spin, mass, charge, discrete symmetries in terms of such systemic symmetry. Observe how the particles diversity is manifested in terms of wholeness.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

High-index-ring three-layer fibresfor mode-locked sub-1.3 {mu}m fibre lasers

This paper addresses issues pertaining to the propagation of ultrashort pulses in the cavities of mode-locked sub-1.3 {mu}m fibre lasers. We demonstrate that multimode high-index-ring three-layer optical fibres operating on a single higher order HE{sub 1m} mode are an effective approach to dispersion compensation. We present optimal parameters of the refractive-index profile in such fibres, which ensure zero first- and second-order chromatic dispersion coefficients at 1.06 {mu}m for the HE{sub 12} and HE{sub 13} modes, and analyse their dispersion and power parameters. (optical fibres and waveguides)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Feed-Forward Compensation for Model Predictive Control in Tri-port Current-Source Medium-Voltage String Inverters for PV-Plus-Storage Farms

The novel tri-port current-source medium-voltage string inverter (TCS-MVSI) is a promising candidate for large-scale PV-plus-storage (PVS) farms owing to its galvanic isolation, easy storage integration, soft-switching capability across entire load range, controlled low dv/dt and EMI, benign fault tolerance, etc. Due to its low inertia feature, traditional PI-based control cannot manage large transients effectively. Instead, a model-based predictive control (MPC) is proposed to achieve robust and stable operation. As is well known, the control performance of MPC is compromised by the sampling and computational delay during implementation significantly, if not well addressed. This paper analyzed and quantified these delays and then proposes feed-forward compensation (FFC) for the MPC method to compensate the delays and the large parameter variations due to the low-inertia nature. In addition, this method also compensates for the high dc-link ripple within each switching cycle, a unique issue for low-inertia converters. Here, the proposed method requires low computational effort, allowing it to be extended for multiple ports. The effectiveness of the proposed method has been validated in experiments. In 10 kW test, the proposed method decreases the average dc-link current by 17%, leading to ~20% conduction losses and ~0.5% increase in converter efficiency. In addition, the peak dc-link current also decreases by 15%, resulting in reduced transformer size. As a result, an increased power density can be achieved with the proposed method. Similar improvements have been observed across the power range from 2 kW to 10 kW.

30 DIRECT ENERGY CONVERSION↗

Revisiting cosmological bounds on sterile neutrinos

We employ state-of-the art cosmological observables including supernova surveys and BAO information to provide constraints on the mass and mixing angle of a non-resonantly produced sterile neutrino species, showing that cosmology can effectively rule out sterile neutrinos which decay between BBN and the present day. The decoupling of an additional heavy neutrino species can modify the time dependence of the Universe's expansion between BBN and recombination and, in extreme cases, lead to an additional matter-dominated period; while this could naively lead to a younger Universe with a larger Hubble parameter, it could later be compensated by the extra radiation expected in the form of neutrinos from sterile decay. However, recombination-era observables including the Cosmic Microwave Background (CMB), the shift parameter R{sub CMB} and the sound horizon r{sub s} from Baryon Acoustic Oscillations (BAO) severely constrain this scenario. We self-consistently include the full time-evolution of the coupled sterile neutrino and standard model sectors in an MCMC, showing that if decay occurs after BBN, the sterile neutrino is essentially bounded by the constraint sin{sup 2}θ ∼< 0.026 (m{sub s}/eV){sup −2}.

79 ASTRONOMY AND ASTROPHYSICS↗

Method and system to separate optically measured coupled parameters

A system includes a first optical sensor sensitive to both a parameter of interest, Parameter1, and at least one confounding parameter, Parameter2 and a second optical sensor sensitive only to the confounding parameter. Measurement circuitry measures M1 in response to light scattered by the first optical sensor, where M1=value of Parameter1+K*value of Parameter2. The measurement circuitry also measures M2 in response to light scattered by the second optical sensor, where M2=value of Parameter2. Compensation circuitry determines a compensation factor, K, for the confounding parameter based on measurements of M1 and M2 taken over multiple load/unload cycles or over one or more thermal cycles. The compensation factor is used to determine the parameter of interest.

Ganguli, Anurag↗

Investigation and Compensation of Circulating Current Errors in Low Frequency Operation of Modular Multilevel Converters

The errors between the reference and actual injected circulating currents are investigated for modular multilevel converters (MMCs) in low frequency operation. These errors cause low frequency oscillatory power components in the MMC arms and large voltage fluctuations in the submodule capacitors. By adjusting the circulating current reference with a single parameter, it is possible to compensate the errors and suppress the undesired voltage fluctuations. Computer simulations and experimental results are provided to verify the theoretical derivations.

modular multilevel converter, low frequency operat↗

Magnet system optimization for segmented adaptive-gap in-vacuum undulator

Segmented Adaptive Gap in-vacuum Undulator (SAGU), in which different segments have different gaps and periods, promises a considerable spectral performance gain over a conventional undulator with uniform gap and period. According to calculations, this gain can be comparable to the gain achievable with a superior undulator technology (e.g. a room-temperature in-vacuum hybrid SAGU would perform as a cryo-cooled hybrid in-vacuum undulator with uniform gap and period). However, for reaching the high spectral performance, SAGU magnetic design has to include compensation of kicks experienced by the electron beam at segment junctions because of different deflection parameter values in the segments. Here we show that such compensation to large extent can be accomplished by using a passive correction, however, simple correction coils are nevertheless required as well to reach perfect compensation over a whole SAGU tuning range. Magnetic optimizations performed with Radia code, and the resulting undulator radiation spectra calculated using SRW code, demonstrating a possibility of nearly perfect correction, are presented.

47 OTHER INSTRUMENTATION↗

Practical guide to understanding goodness-of-fit metrics used in chemical state modeling of x-ray photoelectron spectroscopy data by synthetic line shapes using nylon as an example

Chemical state analysis of a sample surface through fitting bell-shaped curves to x-ray photoelectron spectroscopic polymer data is reviewed using nylon to introduce and discuss aspects of data analysis. Different strategies for modeling chemistry in nylon spectra are presented and in so doing, a case is made to include in published science the design logic and implementation in terms of line shapes and optimization parameter constraints between components in a peak model. Imperfections in line shape relative to the true shape for photoemission lines, when compensated for using constraints to optimization parameters, are shown to provide chemical state information about a sample that justify, for peak models constructed with these limitations, metrics for goodness-of-fit different from those expected for pulse-counted data.

Materials Science↗

Model Calibration vs. Physics-guided Coverage Mapping: Case Study - Pressure Drop Calculations

This work deals with a fundamental question in model validation: given a body of available experiments and an envisaged domain of nuclear reactor operating conditions (referred to as the reactor application), how can one develop a quantitative approach that measures the portion of the prior uncertainties of the reactor application that is covered by the available experiments? Coverage here means that the uncertainties of the reactor application are originating from and behaving in exactly the same way as those observed at the experimental conditions. This approach is valuable as it provides a scientifically defendable criterion by which experimentally measured biases can be credibly extrapolated (i.e., mapped) to biases for the reactor applications. This work focuses on the application of a new methodology, referred to as physics-guided coverage mapping (PCM), to the estimation of hydraulic pressure losses in reactor pipes. PCM provides a generic, calibration-free approach to the mapping of experimental biases by relying on high fidelity physics simulation and information theoretic measure how much of the application domain is covered by the experiments. The idea is to employ the physics models to establish a joint probability distribution that relates the application and the available body of experiments. An information-theoretic measure, referred to as the mutual information, is used to calculate a quantitative metric that measures the inter-dependence between the application and the experiment. A virtual experiment is employed to demonstrate the application of PCM, wherein the pressure drop is calculated for both the experiment and the application using two different flow conditions, i.e., laminar and turbulent, and the experimental values are simulated. All parameters introducing uncertainties, such as geometry, friction factor formulas and their associated parameters are also incorporated. The results obtained with PCM are compared to a conventional calibration-based approach. This work show that the proposed approach can circumvent a number of challenges that face calibration-based methods, such as nonlinearity, ill-posedness and error compensation in high dimensional models with many parameters. This work focus primarily in this summary on parameter uncertainties and how they can be treated using PCM. In a separate summary, discuss performance of PCM under the presence of modeling uncertainties. This simple study has shown that calibration techniques for very simple situations cannot correctly scale the measurements from the experimental to the application domain. It is our view that is occurs primarily due the phenomenon of error compensation where on artificially changes the value of selected parameters to account for all sources of uncertainties. The situation gets more complicated when one calibrates multiple parameters where now the problem could potentially have an infinite number of ways by which the errors can be compensated. (authors)

42 ENGINEERING↗