Search NASA⌕ Search

SEARCH · Search NASA

Results for “particle therapy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

A TOPAS model for lens-based proton radiography

Abstract Objective. Proton Radiography can be used in conjunction with proton therapy for patient positioning, real-time estimates of stopping power, and adaptive therapy in regions with motion. The modeling capability shown here can be used to evaluate lens-based radiography as an instantaneous proton-based radiographic technique. The utilization of user-friendly Monte Carlo program TOPAS enables collaborators and other users to easily conduct medical- and therapy- based simulations of the Los Alamos Neutron Science Center (LANSCE). The resulting transport model is an open-source Monte Carlo package for simulations of proton and heavy ion therapy treatments and concurrent particle imaging. Approach. The four-quadrupole, magnetic lens system of the 800-MeV proton beamline at LANSCE is modeled in TOPAS. Several imaging and contrast objects were modelled to assess transmission at energies from 230–930 MeV and different levels of particle collimation. At different proton energies, the strength of the magnetic field was scaled according to βγ, the inverse product of particle relativistic velocity and particle momentum. Main results. Materials with high atomic number, Z, (gold, gallium, bone-equivalent) generated more contrast than materials with low-Z (water, lung-equivalent, adipose-equivalent). A 5-mrad collimator was beneficial for tissue-to-contrast agent contrast, while a 10-mrad collimator was best to distinguish between different high-Z materials. Assessment with a step-wedge phantom showed water-equivalent path length did not scale directly according to predicted values but could be mapped more accurately with calibration. Poor image quality was observed at low energies (230 MeV), but improved as proton energy increased, with sub-mm resolution at 630 MeV. Significance. Proton radiography becomes viable for shallow bone structures at 330 MeV, and for deeper structures at 630 MeV. Visibility improves with use of high-Z contrast agents. This modality may be particularly viable at carbon therapy centers with accelerators capable of delivering high energy protons and could be performed with carbon therapy.

60 APPLIED LIFE SCIENCES↗

Performance Analysis of PIConGPU: Particle-in-Cell on GPUs using NVIDIA’s NSight Systems and NSight Compute

PIConGPU, Particle In Cell on GPUs, is an open source simulations framework for plasma and laser-plasma physics used to develop advanced particle accelerators for radiation therapy of cancer, high energy physics and photon science. While PIConGPU has been optimized for at least 5 years to run well on NVIDIA GPU-based clusters, there has been limited exploration by the development team of potential scalability bottlenecks using recently updated and new tools including NVIDIA’s NVProf tool and the brand-new NVIDIA NSight Suite (Systems and Compute) tools. PIConGPU is a highly optimized application that runs production jobs at scale on a system Oak Ridge Leadership Facility’s (OLCF) Summit supercomputer (using the full machine at 4600 nodes; at 98% of GPU utilization on all ~28000 NVIDIA Volta GPUs). PIConGPU has been selected as one of the the eight applications for OLCF’s coveted Center for Accelerated Application Readiness (CAAR) program aimed at the facility’s Frontier supercomputer (OLCF’s first exascale system to launch in 2021), to partner with our vendors (primary vendors: AMD and Cray/HPE) ensuring that Frontier will be able to perform large-scale science when it opens to users in 2022. To this effect, performance engineers on the PIConGPU team wanted to dive deep into the application to understand at the finest granularity, which portions of the code could be further optimized to exploit the hardware on Summit at it’s maximum potential and also to elucidate which key kernels should be tracked and optimized for the CAAR effort to port this code to Frontier. Any bottlenecks that are observed via performance profiling on Summit are likely to also impact scalability on the Frontier-dev system and the Frontier Early Access (EA) system. Additionally, the engineers wanted to take a closer look at the newest NVIDIA profiling tools which allows us to identify the most useful features on these tools and will provide an opportunity to compare it to new AMD and Cray’s performance analysis tool releases and provide feedback to our vendor partners on what features are most important and mission critical for CAAR efforts. The primary goal of this report is to focus on the evaluation of PIConGPU’s most time-intensive kernels using NVProf and NSight Suite. Three kernels, Current Deposition (also known as Compute Current), Particle Push (Move and Mark), and Shift Particles are known to be some of the most time-consuming kernels in PIConGPU. The Current xi Deposition kernel and Particle Push kernel both set up the particle attributes for running any physics simulation with PIConGPU, so it is crucial to improve the performance of these two kernels. In this report, we measure single GPU metrics for the three kernels, offer high level takeaways from the conducted analysis, and compare the profiling data from NSight Compute to that of NVProf. This analysis was performed using a grid size of 240 x 272 x 224, and 10 time steps with the Mid-November Figure of Merit (FOM) run setup. The Traveling Wave Electron Acceleration (TWEAC) science case used in this run is a representative science case for PIConGPU. This execution can also be used for baseline analysis on AMD MI50/ MI60 systems. As of the time of writing, the PIConGPU application has limited use for features of NSight Systems, so this report will mainly focus on insights garnered from NSight Compute. For this analysis, we run the “full” metric set available in NSight Compute version 2020.1.2 and use NSight Systems version 2020.3.1 to generate the application timeline.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Systematic Design and Experimental Demonstration of Transmission-Type Multiplexed Acoustic Metaholograms

Acoustic holograms have promising applications in sound-field reconstruction, particle manipulation, ultrasonic haptics, and therapy. This study reports on the theoretical, numerical, and experimental investigation of multiplexed acoustic holograms at both audio and ultrasonic frequencies via a rationally designed transmission-type acoustic metamaterial. The proposed metahologram is composed of two Fabry–Pérot resonant channels per unit cell, which enables the simultaneous modulation of the transmitted amplitude and phase at two desired frequencies. In contrast to conventional acoustic metamaterial-based holograms, the design strategy proposed here provides a new degree of freedom (frequency) that can actively tailor holograms that are otherwise completely passive and significantly enhances the information encoded in acoustic metamaterials. To demonstrate the multiplexed acoustic metamaterial, the projection of two different high-quality metaholograms is first shown at 14 and 17 kHz, with the patterns of the letters N and S. Then, two-channel ultrasound focusing and annular beams generation for the incident ultrasonic frequencies of 35 and 42.5 kHz are demonstrated. Furthermore, these multiplexed acoustic metaholograms offer a technical advance to tackle the rising challenges in the fields of acoustic metamaterials, architectural acoustics, and medical ultrasound.

36 MATERIALS SCIENCE↗

Transformative Technology for FLASH Radiation Therapy

The general concept of radiation therapy used in conventional cancer treatment is to increase the therapeutic index by creating a physical dose differential between tumors and normal tissues through precision dose targeting, image guidance, and radiation beams that deliver a radiation dose with high conformality, e.g., protons and ions. However, the treatment and cure are still limited by normal tissue radiation toxicity, with the corresponding side effects. A fundamentally different paradigm for increasing the therapeutic index of radiation therapy has emerged recently, supported by preclinical research, and based on the FLASH radiation effect. FLASH radiation therapy (FLASH-RT) is an ultra-high-dose-rate delivery of a therapeutic radiation dose within a fraction of a second. Experimental studies have shown that normal tissues seem to be universally spared at these high dose rates, whereas tumors are not. While dose delivery conditions to achieve a FLASH effect are not yet fully characterized, it is currently estimated that doses delivered in less than 200 ms produce normal-tissue-sparing effects, yet effectively kill tumor cells. Despite a great opportunity, there are many technical challenges for the accelerator community to create the required dose rates with novel compact accelerators to ensure the safe delivery of FLASH radiation beams.

43 PARTICLE ACCELERATORS↗

Thorium chelators for targeted alpha therapy: Rapid chelation of thorium-226

We report one of the main challenges in targeted alpha therapy is assuring delivery of the α-particle dose to the targeted cells. Thus, it is critical to identify ligands for α-emitting radiometals that will form complexes that are very stable, both in vitro and in vivo. In this investigation, thorium-227 (t 1/2 = 18.70 days) chelation of ligands containing hydroxypyridinonate (HOPO) or picolinic acid (pa) moieties and the stability of the resultant complexes were studied. Chelation reactions were followed by reversed-phased HPLC and gamma spectroscopy. Studies revealed that high 227 Th chelation yields could be obtained within 2.5 h or less with ligands containing four Me-3,2-HOPO moieties, 1 (83%) and 2 (65%), and also with ligands containing pa moieties, H 4 octapa 3 (65%) and H 4 py4pa 6 (87%). No reaction occurred with H 4 neunpa-p-Bn-NO 2 4, and the chelation reaction with another pa ligand H 4 pypa 5 gave inconsistent yields with a very broad radio-HPLC peak. The ligands spermine-(Me-3,2-HOPO) 4 1, H 4 octapa 3, and H 4 py4pa 6 had high stability (i.e., 87% of 227 Th still bound to the ligand) in phosphate-buffered saline at room temperature over a 6-day period. Preliminary studies with ligand 6 demonstrated efficient chelation of thorium-226 (t 1/2 = 30.57 min) when heated to 80°C for 5 min.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The 20th Gray lecture 2019: Health and heavy ions

Particle radiobiology has contributed new understanding of radiation safety and underlying mechanisms of action to radiation oncology for the treatment of cancer, and to planning of radiation protection for space travel. This manuscript will highlight the significance of precise physical and biologically effective dosimetry to this translational research for the benefit of human health. This review provides a brief snapshot of the evolving scientific basis for, and the complex current global status, and remaining challenges of hadron therapy for the treatment of cancer. The need for particle radiobiology for risk planning in return missions to the Moon, and exploratory deep-space missions to Mars and beyond are also discussed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Gain characterization of LGAD sensors with beta particles and 28-MeV protons

Low Gain Avalanche Diodes, also known as LGADs, are widely considered for fast-timing applications in high energy physics, nuclear physics, space science, medical imaging, and precision measurements of rare processes. Such devices are silicon-based and feature an intrinsic gain due to a p + -doped layer that allows the production of a controlled avalanche of carriers, with multiplication on the order of 10–100. This technology can provide time resolution on the order of 20–30 ps, and variants of this technology can provide precision tracking too. The characterization of LGAD performance has so far primarily been focused on the interaction of minimum ionizing particles for high energy and nuclear physics applications. This article expands the study of LGAD performance to highly-ionizing particles, such as 28-MeV protons, which are relevant for several future scientific applications, e.g. in biology and medical physics, among others. These studies were performed with a beam of 28-MeV protons from a tandem Van de Graaff accelerator at Brookhaven National Laboratory and beta particles from a ^90Sr source; these were used to characterize the response and the gain of an LGAD as a function of bias voltage and collected charge. Here, the experimental results are also compared to TCAD simulations.

47 OTHER INSTRUMENTATION↗

Perspectives on the generation of electron beams from plasma-based accelerators and their near and long term applications

This article first gives the authors' perspectives on how the field of plasma-based acceleration (PBA) developed and how the current experiments, theory, and simulations are motivated by long term applications of PBA to a future linear collider and an x-ray free electron laser. Here, we then focus on some early applications that will likely emerge from PBA research such as electron beam radiotherapy, directional but incoherent x-ray beams for science and technology, near single cycle continuously tunable infrared pulses for spectroscopy, and non-perturbative quantum electrodynamics enabled by PBA electron beams. In our opinion, these near term applications could be developed within the next decade with a concerted effort by the community.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Reining in Radium for Nuclear Medicine: Extra-Large Chelator Development for an Extra-Large Ion

Targeted α therapy (TAT) of soft-tissue cancers using the α particle-emitting radionuclide 223 Ra holds great potential because of its favorable nuclear properties, adequate availability, and established clinical use for treating metastatic prostate cancer of the bone. Despite these advantages, the use of 223 Ra has been largely overshadowed by other α emitters due to its challenging chelation chemistry. A key criterion that needs to be met for a radionuclide to be used in TAT is its stable attachment to a targeting vector via a bifunctional chelator. The low charge density of Ra 2+ arising from its large ionic radius weakens its electrostatic binding interactions with chelators, leading to insufficient complex stability in vivo. In this study, we synthesized and evaluated macropa-XL as a novel chelator for 223 Ra. It bears a large 21-crown-7 macrocyclic core and two picolinate pendent groups, which we hypothesized would effectively saturate the large coordination sphere of the Ra 2+ ion. The structural chemistry of macropa-XL was first established with the nonradioactive Ba 2+ ion using X-ray diffraction and X-ray absorption spectroscopy, which revealed the formation of an 11-coordinate complex in a rare anti pendent-arm configuration. Subsequently, the stability constant of the [Ra(macropa-XL)] complex was determined via competitive cation exchange with 223 Ra and 224 Ra radiotracers and compared with that of macropa, the current state-of-the-art chelator for Ra 2+ . A moderate log K ML value of 8.12 was measured for [Ra(macropa-XL)], which is approximately 1.5 log K units lower than the stability constant of [Ra(macropa)]. This relative decrease in Ra 2+ complex stability for macropa-XL versus macropa was further probed using density functional theory calculations. Additionally, macropa-XL was radiolabeled with 223 Ra, and the kinetic stability of the resulting complex was evaluated in human serum. Furthermore, although macropa-XL could effectively bind 223 Ra under mild conditions, the complex appeared to be unstable to transchelation. Collectively, this study sheds additional light on the chelation chemistry of the exotic Ra 2+ ion and contributes to the small, but growing, number of chelator development efforts for 223 Ra-based TAT.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Second Report of the Nuclear Data Subcommittee of the Nuclear Science Advisory Committee

The central importance of the nuclear data curated by the US Nuclear Data Program (USNDP) for clean energy generation, national security, nonproliferation, medical applications, and space exploration as well as basic science was described in a prior report issued by the DOE/NSF Nuclear Science Advisory Committee subcommittee on Nuclear Data (NSAC-ND) in September 2022. In this report, we present a set of fourteen (14) recommendations that will enhance and advance DOE-NP's stewardship of nuclear data. The first three recommendations focus on the existing core USNDP capabilities, namely: 1) Support the nuclear structure evaluation workforce to improve the currency, consistency, and accessibility of the Evaluated Nuclear Structure Data File (ENSDF); 2) Enhance nuclear reaction evaluation within the USNDP in support of the Evaluated Nuclear Data File (ENDF) through expansion of the workforce and integration of high-performance computing, automation, and machine learning and; 3) Continue atomic mass evaluation in support AME and NUBASE databases. This is followed by eight (8) recommendations representing new cross-cutting initiatives involving both measurement and evaluation to address outstanding nuclear data needs. These new initiatives require a highly trained, diverse workforce that includes personnel with expertise from both inside and outside the nuclear physics community from which evaluators have traditionally been recruited. As such, many of these initiatives are accomplished via a Topical Nuclear Data Collaborations (TNDC). A TNDC is made up of domestic and international stakeholders, subject matter and nuclear data experts, and nuclear data evaluators and features a workforce development plan to ensure that nuclear data evaluators maintain currency in the relevant applications and are seen as equity partners in the endeavor. These include: 1) Establish a coordinated effort to improve evaluation and modeling in nuclear astrophysics for stellar dynamics, multi-messenger astronomy and nucleosynthesis; 2) Initiate a TNDC to develop and maintain nuclear structure evaluation beyond discrete states, including nuclear level densities, photon strength functions and photonuclear data for improved reaction modeling, and exploring nuclear structure at finite temperature; 3) Create a TNDC to perform correlated fission data evaluation, including cross sections, fragment yields, v(A), v(E n ) for nuclear energy, national security, nonproliferation and basic science; 4) From a panel of subject matter experts to establish and annually update a roster of key decay data to nurture its accelerated dissemination including both measurement and evaluation for targeted high-value nuclides for national security, nonproliferation and medical applications; 5) Comprehensive, consistent neutron-induced structure and reaction data for nuclear energy, national security, nonproliferation and planetary nuclear spectroscopy; 6) Charged-particle stopping powers for detector design, space effects and ion beam therapy; 7) High-energy reactions for space exploration and medical nuclide production, and; 8) The creation of an infrastructure for open data and data preservation for use by the entire nuclear physics community. All told, these initiatives require approximately $6.5M increase in NP support of the USNDP in fiscal year 2023 dollars and would require at least 3-5 years to carry out due to the length of time needed to recruit and train new nuclear data researchers. This relatively modest investment would help ensure that the fruits of the nuclear data research carried out by DOE-NP and its collaborators would be brought to bear to address some of the most important needs of our nation and the world. To ensure effective execution of this plan, we present an overview of recruitment, training, and retention goals for the USNDP, the centerpiece of which is a mutually agreed upon code of conduct. Finally, we identify the facility and instrumentation needed to perform the recommended experimental activities. This includes a short review of target fabrication capabilities, reactors, neutron beam, light- and heavy-stable ion, gamma-ray, high-energy and radioactive ion beam facilities. Lastly, a more complete appendix of experimental facilities previously compiled is included with new input provided for 6 facilities.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Cryogenic Liquid Jets for High Repetition Rate Discovery Science

In this paper, we present a detailed procedure for the operation of continuous, micron-sized cryogenic cylindrical and planar liquid jets. When operated as described here, the jet exhibits high laminarity and stability for centimeters. Successful operation of a cryogenic liquid jet in the Rayleigh regime requires a basic understanding of fluid dynamics and thermodynamics at cryogenic temperatures. Theoretical calculations and typical empirical values are provided as a guide to design a comparable system. This report identifies the importance of both cleanliness during cryogenic source assembly and stability of the cryogenic source temperature once liquefied. The system can be used for high repetition rate laser-driven proton acceleration, with an envisioned application in proton therapy. Other applications include laboratory astrophysics, materials science, and next-generation particle accelerators.

42 ENGINEERING↗

Actinium chelation and crystallization in a macromolecular scaffold

Abstract Targeted alpha therapy (TAT) pairs the specificity of antigen targeting with the lethality of alpha particles to eradicate cancerous cells. Actinium-225 [ 225 Ac; t 1/2 = 9.920(3) days] is an alpha-emitting radioisotope driving the next generation of TAT radiopharmaceuticals. Despite promising clinical results, a fundamental understanding of Ac coordination chemistry lags behind the rest of the Periodic Table due to its limited availability, lack of stable isotopes, and inadequate systems poised to probe the chemical behavior of this radionuclide. In this work, we demonstrate a platform that combines an 8-coordinate synthetic ligand and a mammalian protein to characterize the solution and solid-state behavior of the longest-lived Ac isotope, 227 Ac [t 1/2 = 21.772(3) years]. We expect these results to direct renewed efforts for 225 Ac-TAT development, aid in understanding Ac coordination behavior relative to other +3 lanthanides and actinides, and more broadly inform this element’s position on the Periodic Table.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Light and Electron Emission as Breakdown Probes: Synergistic DC and RF Study

The project was motivated by a particular and critical need in accelerator R&D to understand vacuum breakdown and arc as it would allow for developing high gradient machines. Accelerator systems operated at high gradients are less costly and more compact. This, in turn, would enable advanced and cost-effective accelerators for future colliders. Universities and medical centers would be able to build compact accelerator machines for basic X-ray and microscopy sciences, therapy, isotope production, sterilization etc.

43 PARTICLE ACCELERATORS↗

Single-particle detection of enhanced polarizability in Au-decorated semiconducting nanorods via scanning dielectric microscopy

Hybrid nanostructures that combine semiconducting and metallic components offer great potential for photothermal therapy, optoelectronics, and sensing, by integrating tunable optical properties with enhanced light absorption and charge transport. Boosting the integrated performance of these hybrid systems demands techniques capable of probing local variations of the physical properties inaccessible to bulk analysis. Here, we report the single-particle dielectric characterization of hybrid, semiconducting bismuth sulfide (Bi 2 S 3 ) nanorods (NR) decorated with metallic Au nanoparticles (NP), employing scanning dielectric microscopy, which uses electrostatic force microscopy in combination with finite-element numerical simulations. We reveal a pronounced enhancement in the local dielectric response of Bi2S3 upon Au decoration, attributed to interfacial polarization and electron transfer from Au to the Bi 2 S 3 matrix, thus suggesting a enhanced metallic-like polarizability at the single-particle level. Numerical simulations show that the response is dominated by the vertical component of the permittivity and that the decorating metallic Au NP produce only moderate shielding of the semiconductor Bi 2 S 3 NR core, indicating that the large increase in the dielectric response originates primarily from intrinsic modifications within the NR. Overall, these findings provide direct insight into structure–property relationships at the single-particle level, supporting the rational design of advanced hybrid nanostructures with tailored electronic functionalities.

36 MATERIALS SCIENCE↗

Defective Interfering Viral Particle Treatment Reduces Clinical Signs and Protects Hamsters from Lethal Nipah Virus Disease

Defective interfering particles (DIs) contain a considerably smaller genome than the parental virus but retain replication competency. As DIs can directly or indirectly alter propagation kinetics of the parental virus, they offer a novel approach to antiviral therapy, capitalizing on knowledge from natural infection. However, efforts to translate in vitro inhibition to in vivo screening models remain limited. We investigated the efficacy of virus-like particles containing DI genomes (therapeutic infectious particles [TIPs]) in the Syrian hamster model of lethal Nipah virus (NiV) disease. We found that coadministering a high dose of TIPs intraperitoneally with virus challenge improved clinical course and reduced lethality. To mimic natural exposure, we also evaluated lower-dose TIP delivery and virus challenge intranasally, finding equally efficacious reduction in disease severity and overall lethality. Eliminating TIP replicative capacity decreased efficacy, suggesting protection via direct inhibition. These data provide evidence that TIP-mediated treatment can confer protection against disease and lethal outcome in a robust animal NiV model, supporting further development of TIP treatment for NiV and other high-consequence pathogens.

59 BASIC BIOLOGICAL SCIENCES↗

Production, isolation, and shipment of clinically relevant quantities of astatine-211: A simple and efficient approach to increasing supply

The alpha emitter astatine-211 ( 211 At) is a promising candidate for cancer treatment based on Targeted Alpha (α) Therapy (TAT). A small number of facilities, distributed across the United States, are capable of accelerating α-particle beams to produce 211 At. However, challenges remain regarding strategic methods for shipping 211 At in a form adaptable to advanced radiochemistry reactions and other uses of the radioisotope. Purpose: Our method allows shipment of 211 At in various quantities in a form convenient for further radiochemistry. Procedures: For this study, a 3-octanone impregnated Amberchrom® CG300M resin bed in a column cartridge was used to separate 211 At from the bismuth matrix on site at the production accelerator (Texas A&M) in preparation for shipping. Aliquots of 6 M HNO 3 containing up to ≈2.22 GBq of 211 At from the dissolved target were successfully loaded and retained on columns. Exempt packages (<370 MBq) were shipped to a destination radiochemistry facility, University of Texas MD Anderson Cancer Center, in the form of a convenient air-dried column. Type A packages have been shipped overnight to University of Alabama at Birmingham. Main findings: Air-dried column hold times of various lengths did not inhibit simple and efficient recovery of 211 At. Solution eluted from the column was sufficiently high in specific activity to successfully radiolabel a model compound, 4-(4,4,5,5-tetramethyl-1,3,2-dioxaborolan-2-yl)aniline (1), with 211 At. The method to prepare and ship 211 At described in this manuscript has also been used to ship larger quantities of 211 At a greater distance to University of Alabama at Birmingham. Principal conclusions: The successful proof of this method paves the way for the distribution of 211 At from Texas A&M University to research institutions and clinical oncology centers in Texas and elsewhere. Finally, use of this simple method at other facilities has the potential increase the overall availability of 211 At for preclinical and clinical studies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A multi-MeV alpha particle source via proton-boron fusion driven by a 10-GW tabletop laser

Nuclear fusion between protons and boron-11 nuclei has undergone a revival of interest thanks to the rapid progress in pulsed laser technology. Potential applications of such reaction range from controlled nuclear fusion to radiobiology and cancer therapy. A laser-driven fusion approach consists in the interaction of high-power, high-intensity pulses with H- and B-rich targets. We report on an experiment exploiting proton-boron fusion in CN-BN targets to obtain high-energy alpha particle beams (up to 5 MeV) using a very compact approach and a tabletop laser system with a peak power of ~10 GW, which can operate at high-repetition rate (up to 1 kHz). The secondary resonance in the cross section of proton-boron fusion (~150 keV in the center-of-mass frame) is exploited using a laser-based approach. The generated alpha particles are characterized in terms of energy, flux, and angular distribution using solid-state nuclear-track detectors, demonstrating a flux of ~10 5 particles per second at 10 Hz, and ~10 6 per second at 1 kHz. Hydrodynamic and particle-in-cell numerical simulations support our experimental findings. Potential impact of our approach on future spread of ultra-compact, multi-MeV alpha particle sources driven by moderate intensity (10 16 -10 17 W/cm 2 ) laser pulses is anticipated.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗