Search NASA⌕ Search

SEARCH · Search NASA

Results for “performance calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

SNPP VIIRS Day Night Band: Ten Years of On-Orbit Calibration and Performance

Aboard the polar-orbiting SNPP satellite, the VIIRS instrument has been in operation since launch in October 2011. It is a visible and infrared radiometer with a unique panchromatic channel capability designated as a day-night band (DNB). This channel covers wavelengths from 0.5 to 0.9 µm and is designed with a near-constant spatial resolution for Earth observations 24 h a day. The DNB operates at 3 gain stages (low, middle, and high) to cover a large dynamic range. An onboard solar diffuser (SD) is used for calibration in the low gain stage, and to enable the derivation of gain ratios between the different stages. In this paper, we present the SNPP VIIRS DNB calibration performed by the NASA VIIRS characterization support team (VCST). The DNB calibration algorithms are described to generate the calibration coefficient look up tables (LUTs) for the latest NASA Level 1B Collection 2 products. We provide an evaluation of DNB on-orbit calibration performance. This activity supports the NASA Earth science community by delivering consistent VIIRS sensor data products via the Land Science Investigator-led Processing Systems, including the SD degradation applied for DNB calibrations in detector gain and gain ratio trending. The DNB stray light contamination and its correction are highlighted. Performance validations are presented using comparisons to the calibration methods employed by NOAA’s operational Interface Data Processing Segment. Further work on stray light corrections is also discussed.

VIIRS↗

DSS range delay calibrations: Current performance level

A means for evaluating Deep Space Station (DSS) range delay calibration performance was developed. Inconsistencies frequently noted in these data are resolved. Development of the DSS range delay data base is described. The data base is presented with comments regarding apparent discontinuities. Data regarding the exciter frequency dependence of the delay values are presented. The improvement observed in the consistency of current DSS range delay calibration data over the performance previously observed is noted.

Spradlin, G. L.↗

Ten Years of SNPP VIIRS Reflective Solar Bands On-Orbit Calibration and Performance

The Visible Infrared Imaging Radiometer Suite (VIIRS) onboard the Suomi National Polar-orbiting Partnership (SNPP) has successfully operated on-orbit for nearly ten years since its launch in October 2011, continuously making global observations and improving studies of changes in the Earth’s climate and environment. VIIRS has 22 spectral bands, among which 14 are reflective solar bands (RSBs) covering a spectral range from 0.41 to 2.25 μm. The SNPP VIIRS RSBs are primarily calibrated by the onboard solar diffuser (SD), with its on-orbit degradation tracked by an onboard SD stability monitor (SDSM). The near-monthly scheduled lunar observations, together with the sensor responses over stable ground targets, have contributed to the sensor’s mission-long on-orbit calibration and characterization. Numerous improvements have been made in the RSB calibration methodology since SNPP VIIRS was launched, and the RSB calibration has reached a mature stage after almost ten years of on-orbit operation. SNPP is a joint NASA/NOAA mission and there are two teams, the NASA VIIRS Calibration Support Team (VCST) and the NOAA VIIRS Sensor Data Record Team, which are dedicated to SNPP VIIRS on-orbit calibration. In this paper, we focus on the calibration performed by the NASA VCST. The SNPP VIIRS RSB calibration methodologies used to produce the calibration coefficient look up tables for the latest NASA Level 1B Collection 2 products are reviewed and the calibration improvements incorporated in this collection are described. Recent calibration changes include the removal of image striping caused by non-uniform degradation of the SD, improvements to the method for combining lunar and SD data, mitigation of the effects due a recent anomaly in the SD measurements, estimation of the SD degradation beyond 935 nm, and fitting strategy improvements for look-up table delivery. Overall, the SNPP VIIRS RSBs have performed well since its launch and continue to meet design specifications.

SNPP↗

Reliable Power Rating of Perovskite PV Modules: Preprint

As the perovskite technology is ramping up into commercialization, reliable and accurate power rating of large-size perovskite modules becomes a prominent aspect for its future deployment in the PV market. It is known that the performance calibration of perovskite PV devices is very challenging due to its complex dynamic response during a conventional current-voltage (IV) measurement. PV researchers have previously proposed several steady-state performance calibration methods to reliably extract PV efficiencies, but mostly focus on small area research-type cells. In this paper, we emphasize the importance of reliable performance calibration on large-size perovskite modules. Extending the NREL Cell and Module Performance (CMP) group’s steady-state performance calibration protocol (i.e., Asymptotic PMAX Scan) for perovskite cells to modules, we justify the necessity of reporting steady-state efficiencies for perovskite cells and discuss the challenges of applying this protocol to modules. We also present our protocol for Maximum Power Point Tracking (MPPT), which is a technique often used for performance calibration of perovskite cells and modules, and show a comparison between MPPT and Asymptotic PMAX. Using MPPT we demonstrate the interplay between metastability and degradation in perovskite modules, and emphasize the necessity to develop preconditioning protocols for stabilizing these devices. Our aim is to promote development of consensus protocols for performance calibration of perovskite modules, and to advance their credible power ratings, which will be beneficial to the growth of perovskite technology in the PV market.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Reliable Power Rating of Perovskite PV Modules

As the perovskite technology is ramping up into commercialization, reliable and accurate power rating of large-size perovskite modules becomes a prominent aspect for its future deployment in the PV market. It is known that the performance calibration of perovskite PV devices is very challenging due to its complex dynamic response during a conventional current-voltage (IV) measurement. PV researchers have previously proposed several steady-state performance calibration methods to reliably extract PV efficiencies, but mostly focus on small area research-type cells. In this paper, we emphasize the importance of reliable performance calibration on large-size perovskite modules. Extending the NREL Cell and Module Performance (CMP) group's steady-state performance calibration protocol (i.e., Asymptotic P MAX Scan) for perovskite cells to modules, we justify the necessity of reporting steady-state efficiencies for perovskite cells and discuss the challenges of applying this protocol to modules. We also present our protocol for Maximum Power Point Tracking (MPPT), which is a technique often used for performance calibration of perovskite cells and modules, and show a comparison between MPPT and Asymptotic P MAX . Using MPPT we demonstrate the interplay between metastability and degradation in perovskite modules, and emphasize the necessity to develop preconditioning protocols for stabilizing these devices. Our aim is to promote development of consensus protocols for performance calibration of perovskite modules, and to advance their credible power ratings, which will be beneficial to the growth of perovskite technology in the PV market.

perovskite↗

Analysis of the pre-flight and post-flight calibration procedures performed on the Liulin space radiation dosimeter

Liulin, a dosimetry-radiometry system, was developed to satisfy the requirements for active flux and dose rate measurements for the flight of the second Bulgarian cosmonaut in 1988. The system consists of a compact battery-operated silicon solid state detector unit and a read/write microcomputer and telemetry unit. We describe the pre-flight calibrations with charged particles, using radioactive sources and accelerated 170 MeV/nucleon proton and alpha particles at the Dubna, Russia cyclotron. We discuss comparisons with data obtained on Mir with the French-built tissue equivalent LET spectrometer NAUSICAA. Lastly, we describe post-flight calibrations performed with 1 GeV/nucleon 56Fe ions at the Brookhaven National Laboratory AGS accelerator, where the instrument was mounted in tandem with several thin position-sensitive silicon detectors behind a stopping target. The silicon detectors provided an energy spectrum for the surviving charged nuclear fragments for which the flux and absorbed dose were recorded by Liulin.

long duration↗

Evaluating Probabilistic Deep Learning Methods for Uncertainty Quantification of Precipitation Bias Correction

Climate models often exhibit biases in their precipitation predictions, particularly underestimating high-intensity events and overestimating low precipitation. Deep learning approaches offer promising solutions, but their epistemic uncertainty associated with a deep learning–based bias correction method has not previously been quantified for reliable downstream climate impact studies. While methods for capturing the epistemic uncertainty in deep learning frameworks exist, there is currently no consensus on the best method. In this work, we compare three uncertainty quantification (UQ) methods—Deep Ensembles (DEns), Monte Carlo Dropout (MCD), and Flipout—by assessing the reliability of their uncertainty estimates using standard measures such as sharpness and calibration. These UQ methods are applied to an existing deep learning precipitation bias correction model known as UFNet: a coupled U-Net and fully connected neural network. The methods utilized to assess the models’ uncertainties are 1) calibration, which ensures that the expected probabilities of the model align with reality and 2) sharpness, which is a measure of the precision of the model’s probabilistic predictions. Of the three UQ methods evaluated, the DEns and MCD methods demonstrated the best-calibrated performance (expected calibration error of 0.36 and 0.35, respectively), compared to Flipout (0.58). In contrast, Flipout had the sharpest predictions and the highest metric performance in bias correcting precipitation—especially for higher-order moments such as kurtosis with a spatial correlation of 72% compared to 32% and 55% spatial correlation for DEns and MCD, respectively. Of the three UQ methods, MCD was found to be the most suitable method for UQ purposes based on its calibration, sharpness, and computational requirements.

Bayesian methods↗

Calibration and performance of the UCR double Compton gamma ray telescope

Results of the field calibration and performance of the UCR double Compton gamma-ray telescope are presented. The telescope is a balloon-borne instrument with an upper array of 16 plastic scintillator bars and a lower one of 16 NaI(Tl) bars. The telescope is sensitive to celestial gamma rays from 1 to 30 MeV. The data were collected on February 14, 1988 prior to launch in Alice Springs, Australia to observe SN 1987A. Radioactive sources were used to calibrate the energy deposits in the scintillators. Each bar was analyzed laterally using pulse height or timing to obtain the positions of the gamma ray interactions. Double scatter events from an Na-24 source simulating a celestial source were studied to obtain the general performance of the telescope and to develop imaging techniques, later used with the flight data. An angular resolution of 11 deg FWHM and energy resolutions of 13 and 10 percent FWHM at 1.37 and 2.75 MeV, respectively, were found. The efficiency of the telescope is 0.0035 at 1.37 MeV and zenith angle 31 deg.

Ait-Ouamer, Farid↗

Studies of the muon momentum calibration and performance of the ATLAS detector with $pp$ collisions at $\sqrt{s}=13$ TeV

This paper presents the muon momentum calibration and performance studies for the ATLAS detector based on the $pp$ collisions data sample produced at $\sqrt{s}$ = 13 TeV at the LHC during Run 2 and corresponding to an integrated luminosity of 139 fb –1 . An innovative approach is used to correct for potential charge-dependent momentum biases related to the knowledge of the detector geometry, using the $Z$ → $μ^+$ $μ^–$ resonance. The muon momentum scale and resolution are measured using samples of $J/ψ$ → $μ^+$ $μ^–$ and $Z$ → $μ^+$ $μ^–$ events. A calibration procedure is defined and applied to simulated data to match the performance measured in real data. The calibration is validated using an independent sample of $Υ$ → $μ^+$ $μ^–$ events. At the Z ($J/ψ$) peak, the momentum scale is measured with an uncertainty at the 0.05% (0.1%) level, and the resolution is measured with an uncertainty at the 1.5% (2%) level. The charge-dependent bias is removed with a dedicated in situ correction for momenta up to 450 GeV with a precision better than 0.03 TeV –1 .

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

In-flight calibration and performance evaluation of the fixed head star trackers for the solar maximum mission

The Solar Maximum Mission (SMM) spacecraft provides an excellent opportunity for evaluating attitude determination accuracies achievable with tracking instruments such as fixed head star trackers (FHSTs). As a part of its payload, SMM carries a highly accurate fine pointing Sun sensor (FPSS). The EPSS provides an independent check of the pitch and yaw parameters computed from observations of stars in the FHST field of view. A method to determine the alignment of the FHSTs relative to the FPSS using spacecraft data is applied. Two methods that were used to determine distortions in the 8 degree by 8 degree field of view of the FHSTs using spacecraft data are also presented. The attitude determination accuracy performance of the in flight calibrated FHSTs is evaluated.

Thompson, R. H.↗

SNPP and N20 VIIRS Day/Night Band (DNB) Calibration and Performance

The first two Visible Infrared Imaging Radiometer Suite (VIIRS) instruments, on-board the Suomi National Polar-orbiting Partnership (SNPP) and the NOAA-20 (N20) satellites, have been operating for over 11 and 5 years since their launches on28 October 2011 and 18 November 2017 respectively. The day-night band (DNB) onboard VIIRS is a panchromatic visible/near-infrared (Vis/NIR) channel designed to detect radiance from the brightest daytime scenes down to very dim nighttime scenes illuminated by a quarter moon. In this paper, we present the SNPP and N20 VIIRS DNB calibration results performed by the NASA VIIRS Characterization Support Team (VCST) to generate the calibration coefficient look up tables (LUTs) for the latest NASA Level 1B Collection 2 products. The differing DNB straylight contamination between VIIRS instruments is discussed along with the correction methodology and performance.

Junqiang Sun↗

Calibrating Laser Gas Measurements by Use of Natural CO2

An improved method of calibration has been devised for instruments that utilize tunable lasers to measure the absorption spectra of atmospheric gases in order to determine the relative abundances of the gases. In this method, CO2 in the atmosphere is used as a natural calibration standard. Unlike in one prior calibration method, it is not necessary to perform calibration measurements in advance of use of the instrument and to risk deterioration of accuracy with time during use. Unlike in another prior calibration method, it is not necessary to include a calibration gas standard (and the attendant additional hardware) in the instrument and to interrupt the acquisition of atmospheric data to perform calibration measurements. In the operation of an instrument of this type, the beam from a tunable diode laser or a tunable quantum-cascade laser is directed along a path through the atmosphere, the laser is made to scan in wavelength over an infrared spectral region that contains one or two absorption spectral lines of a gas of interest, and the transmission (and, thereby, the absorption) of the beam is measured. The concentration of the gas of interest can then be calculated from the observed depth of the absorption line(s), given the temperature, pressure, and path length. CO2 is nearly ideal as a natural calibration gas for the following reasons: CO2 has numerous rotation/vibration infrared spectral lines, many of which are near absorption lines of other gases. The concentration of CO2 relative to the concentrations of the major constituents of the atmosphere is well known and varies slowly and by a small enough amount to be considered constant for calibration in the present context. Hence, absorption-spectral measurements of the concentrations of gases of interest can be normalized to the concentrations of CO2. Because at least one CO2 calibration line is present in every spectral scan of the laser during absorption measurements, the atmospheric CO2 serves continuously as a calibration standard for every measurement point. Figure 1 depicts simulated spectral transmission measurements in a wavenumber range that contains two absorption lines of N2O and one of CO2. The simulations were performed for two different upper-atmospheric pressures for an airborne instrument that has a path length of 80 m. The relative abundance of CO2 in air was assumed to be 360 parts per million by volume (approximately its natural level in terrestrial air). In applying the present method to measurements like these, one could average the signals from the two N2O absorption lines and normalize their magnitudes to that of the CO2 absorption line. Other gases with which this calibration method can be used include H2O, CH4, CO, NO, NO2, HOCl, C2H2, NH3, O3, and HCN. One can also take advantage of this method to eliminate an atmospheric-pressure gauge and thereby reduce the mass of the instrument: The atmospheric pressure can be calculated from the temperature, the known relative abundance of CO2, and the concentration of CO2 as measured by spectral absorption. Natural CO2 levels on Mars provide an ideal calibration standard. Figure 2 shows a second example of the application of this method to Mars atmospheric gas measurements. For sticky gases like H2O, the method is particularly powerful, since water is notoriously difficult to handle at low concentrations in pre-flight calibration procedures.

Webster, Chris↗

On-Orbit Calibration and Performance of Aqua MODIS Reflective Solar Bands

Aqua MODIS has successfully operated on-orbit for more than 6 years since its launch in May 2002, continuously making global observations and improving studies of changes in the Earth's climate and environment. 20 of the 36 MODIS spectral bands, covering wavelengths from 0.41 to 2.2 microns, are the reflective solar bands (RSB). They are calibrated on-orbit using an on-board solar diffuser (SD) and a solar diffuser stability monitor (SDSM). In addition, regularly scheduled lunar observations are made to track the RSB calibration stability. This paper presents Aqua MODIS RSB on-orbit calibration and characterization activities, methodologies, and performance. Included in this study are characterizations of detector signal-to-noise ratio (SNR), short-term stability, and long-term response change. Spectral wavelength dependent degradation of the SD bidirectional reflectance factor (BRF) and scan mirror reflectance, which also varies with angle of incidence (AOI), are examined. On-orbit results show that Aqua MODIS onboard calibrators have performed well, enabling accurate calibration coefficients to be derived and updated for the Level 1B (L1B) production and assuring high quality science data products to be continuously generated and distributed. Since launch, the short-term response, on a scan-by-scan basis, has remained extremely stable for most RSB detectors. With the exception of band 6, there have been no new RSB noisy or inoperable detectors. Like its predecessor, Terra MODIS, launched in December 1999, the Aqua MODIS visible (VIS) spectral bands have experienced relatively large changes, with an annual response decrease (mirror side 1) of 3.6% for band 8 at 0.412 microns, 2.3% for band 9 at 0.443 microns, 1.6% for band 3 at 0.469 microns, and 1.2% for band 10 at 0.488 microns. For other RSB bands with wavelengths greater than 0.5 microns, the annual response changes are typically less than 0.5%. In general, Aqua MODIS optics degradation is smaller than Terra MODIS and the mirror side differences are much smaller. Overall, Aqua MODIS RSB on-orbit performance is better than Terra MODIS.

Xiong, Xiaoxiong↗

How Should Researchers Measure Perovskite-Based Monolithic Multijunction Solar Cells’ Performance? A Calibration Lab's Perspective

Perovskite multijunctions (PVSK MJs) have made remarkable progress with monolithic PVSK/PVSK tandems surpassing the efficiency of single-junction (1 J) PVSK cells and PVSK/Si cells reported to exceed the 30% efficiency mark. These efficiencies are reported at standard test conditions (STC), established by the photovoltaic (PV) community to facilitate comparison between devices and technologies. Herein, it is discussed why an accurate STC performance measurement for a MJ is more complicated than for a 1 J cell and the special aspects to be considered when measuring the current-voltage characteristics and the performance of PVSK-containing MJ cells are emphasized. It is discussed why a spectrally adjustable solar simulator is needed and the sequence of accurate performance measurement, namely measurement of the spectral response of each junction, adjustment of the spectrum, and appropriate protocols for measuring the power output of the device at STC, is presented. For all these, common errors and pitfalls that sometime lead to misleading interpretation of the results are presented, and the methods to evaluate the accuracy of the data when a spectrally adjustable solar simulator is not available are recommended. Finally, first step is taken toward recommending performance measurement approaches when high throughput is required as will eventually be in a production line.

14 SOLAR ENERGY↗

Calibration and Performance of Juno Radio Science Data

Juno Radio Science measures the frequency of X- and Ka-band radio links between the Juno spacecraft and the Earth-based observing stations of NASA’s Deep Space Network (DSN) in order to determine the gravitational field of Jupiter. The received frequency contains information on the gravitational field and is also perturbed by the propagation environment, including Earth troposphere and ionosphere, electrons in the solar plasma, electrons in the Io Plasma Torus around Jupiter, and instrumental effects on both the spacecraft and the ground electronics. Each of these effects must be calibrated out of the data to ensure an accurate estimation of the Jupiter gravitational field. This work discusses the data processing, calibration, and performance of the frequency measurements. The precision of the frequency measurements average 1.1 mHz (1σ standard deviation at 60 second integration time), or 5.3 microns/sec in units of velocity. The remaining noise sources are primarily from residual troposphere and charged particles. Further improvement could be made in future radio science experiments with the addition of a cross-link and stiffer ground antennas.

Buccino, Dustin R↗

Calibration and Performance of Juno Radio Science Data

Juno Radio Science measures the frequency of X- and Ka-band radio links between the Juno spacecraft and the Earth-based observing stations of NASA’s Deep Space Network (DSN) in order to determine the gravitational field of Jupiter. The received frequency contains information on the gravitational field and is also perturbed by the propagation environment, including Earth troposphere and ionosphere, electrons in the solar plasma, electrons in the Io Plasma Torus around Jupiter, and instrumental effects on both the spacecraft and the ground electronics. Each of these effects must be calibrated out of the data to ensure an accurate estimation of the Jupiter gravitational field. This work discusses the data processing, calibration, and performance of the frequency measurements. The precision of the frequency measurements average 1.1 mHz (1σ standard deviation at 60 second integration time), or 5.3 microns/sec in units of velocity. The remaining noise sources are primarily from residual troposphere and charged particles. Further improvement could be made in future radio science experiments with the addition of a cross-link and stiffer ground antennas.

Oudrhiri, Kamal↗

Phase Calibration for the Block 1 VLBI System

Very Long Baseline Interferometry (VLBI) in the DSN provides support for spacecraft navigation, Earth orientation measurements, and synchronization of network time and frequency standards. An improved method for calibrating instrumental phase shifts has recently been implemented as a computer program in the Block 1 system. The new calibration program, called PRECAL, performs calibrations over intervals as small as 0.4 seconds and greatly reduces the amount of computer processing required to perform phase calibration.

Roth, M. G.↗

Aqua MODIS: 20 Years of On-orbit Calibration and Performance

Since its launch in May 2002, Aqua MODIS has successfully operated for more than 20 years and has continuously generated a wide range of data products that have enabled and supported the remote sensing community and users worldwide for their studies of the Earth’s system by monitoring changes in its key environmental parameters. Although Aqua MODIS, designed with a lifetime requirement of 6 years, is currently operated in its extended mission phase, it continues to make high quality global observations of the Earth’s surface via its 36 spectral bands that cover wavelengths from visible to long-wave infrared. To date, all instrument on-board calibrators (OBC) remain capable of performing their design functions, providing various calibration data sets to help monitor on-orbit changes in sensor responses and performance characteristics. In addition to the OBC, regularly scheduled lunar observations and select Earth-view targets are used extensively to support sensor on-orbit calibration, especially for the calibration of the visible channels (or bands). In this paper, we provide an overview of Aqua MODIS on-orbit calibration activities and methodologies for both reflective solar bands (RSB) and thermal emissive bands (TEB), illustrate its on-orbit performance over the past 20 years using examples derived from OBC measurements, lunar observations, and Earth-view response trends, and describe various calibration improvements made over its entire mission. We focus on key issues identified since launch, such as solar diffuser degradation, electronic crosstalk, and on-orbit changes in sensor response versus scan-angle, along with approaches and strategies developed to mitigate their impact on sensor calibration quality. Also discussed in this paper are some of the key calibration enhancements incorporated recently in the Collection 6.1 and the upcoming Collection 7 Level-1B algorithms.

Polarization↗