Search NASA⌕ Search

SEARCH · Search NASA

Results for “performance efficiency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Exploring Human Factors Issues for Urban Air Mobility Operations

Urban air mobility (UAM) is currently receiving increased attention in the aviation literature as a new entrant into the airspace. Although the introduction of UAM offers the potential for significant benefits, it also creates the potential for fundamental change to the current air traffic management system. Several concepts are being explored to enable the development of a safe and efficient UAM system for near, mid and far term operations. A concept of operations for near term operations proposes several assumptions. Concepts for roles and responsibilities of human operators such as air traffic controllers propose different degrees of involvement. Identifying and exploring human factors issues is therefore a critical next step in the forward progression of concept development. A human-in-the-loop air traffic control simulation was used to investigate the effect of UAM traffic density and changes in current airspace routes and communication procedures on subjective controller workload and efficiency-related task performance. Findings indicate that although subjective workload was manageable for low density operations, medium and high density operations led to unmanageable levels of workload, leading to refusals to allow more vehicles into controlled airspace. By implementing a letter of agreement, verbal communications were reduced which were associated with reduced workload. Optimized routes were also associated with reduced workload and increased performance efficiency. Although these adjustments can positively support controller performance, workload still remained high during the high density UAM traffic scenarios. It is therefore suggested that, in order for UAM operation to become scalable, human operators will be required to work differently compared to current air traffic controllers. Future research should focus on the level and type of human operator or controller involvement and mated systems, to ensure safety and efficiency within UAM operations.

Air Traffic Management↗

Manipulating the Crystallization Kinetics by Additive Engineering toward High-Efficient Photovoltaic Performance

Additive processing is proven to be an effective method to improve the efficiency and stability of perovskite solar cells; however, its intrinsic role in directing the crystallization pathway and thus morphology formation remains unknown. In situ grazing-incidence wide-angle x-ray scattering (GIWAXS) is applied to study the function of a 1,8-diiodooctane (DIO) additive in manipulating the crystallization behavior of perovskite thin films. It is seen that the DIO additive could induce multi-stage intermediate crystallization phases and increases the activation energy for nucleation and growth, which postpones the perovskite phase transformation time and broadens the transition zone. The elongated crystallization process affords improved perovskite thin film crystallinity and reduces defect density, which enables a longer carrier diffusion length. As a result, improved device efficiency, moisture, and thermal stability can be achieved. The following study provides a new prospective in understanding the additive function in perovskite thin film morphology control from fundamental parameters, indicating the importance of minor processing conditions in global property management toward high device performance.

36 MATERIALS SCIENCE↗

Comprehensive assessment of metrology techniques for heliostat efficiency and performance evaluation

Concentrating solar power plants, specifically central receiver type systems and their heliostat field, are struggling with negative reputation in the USA, due to perceived underperformance and reliability issues. This is in part due to a lack of standards for performance assessment as well as overly simplified techno-economical models. A better understanding of influences and losses along the solar radiation path from the sun, across the solar collector to the receiver, increases the fidelity of heliostat efficiency assessment as well as solar field performance predictions. Such data are currently scarce and require a complete set of metrology capabilities to evaluate direct solar irradiance, sun shape, atmospheric attenuation, reflectance, collector shape, slope errors and total beam dispersion. In preparation for establishing a 3rd party metrology platform in collaboration with Sandia National Labs, NLR conducted a scoping study on available metrology. We present an extensive overview of techniques and commercial systems for each category. Our work includes an analysis to increase understanding of strengths and limitations of the many techniques used for surface shape and slope measurement. This applies to a controlled, indoor or outdoor laboratory environment assessing a single heliostat.

14 SOLAR ENERGY↗

The performance and efficiency of four motor/controller/battery systems for the simpler electric vehicles

A test and analysis program performed on four complete propulsion systems for an urban electric vehicle (EV) is described and results given. A dc series motor and a permanent magnet (PM) motor were tested, each powered by an EV battery pack and controlled by (1) a series/parallel voltage-switching (V-switch) system; and (2) a system using a pulse width modulation, 400 Hz transistorized chopper. Dynamometer tests were first performed, followed by eV performance predictions and data correlating road tests. During dynamometer tests using chopper control; current, voltage, and power were measured on both the battery and motor sides of the chopper, using three types of instrumentation. Conventional dc instruments provided adequate accuracy for eV power and energy measurements, when used on the battery side of the controller. When using the chopper controller, the addition of a small choke inductor improved system efficiency in the lower duty cycle range (some 8% increase at 50% duty cycle) with both types of motors. Overall system efficiency rankings during road tests were: (1) series motor with V-switch; (2) PM motor with V-switch; (3) series motor with chopper; and (4) PM motor with chopper. Chopper control of the eV was smoother and required less driver skill than V-switch control.

Shipps, P. R.↗

Thermal Protection Materials and Systems: Past, Present, and Future

Thermal protection materials and systems (TPS) protect vehicles from the heat generated when entering a planetary atmosphere. NASA has developed many TPS systems over the years for vehicle ranging from planetary probes to crewed vehicles. The goal for all TPS is efficient and reliable performance. Efficient means using the right material for the environment and minimizing the mass of the heat shield without compromising safety. Efficiency is critical if the payload such as science experiments is to be maximized on a particular vehicle. Reliable means that we understand and can predict performance of the material. Although much characterization and testing of materials is performed to qualify and certify them for flight, it is not possible to completely recreate the reentry conditions in test facilities, and flight-testing

Johnson, Sylvia M.↗

Getting Beyond Widgets: Performance of Efficient Indoor Air Quality System Retrofit Packages for Schools A report on the modeled energy, greenhouse gas, and cost savings of several multi-measure retrofit packages for energy efficiency and indoor air quality in primary schools

School facilities are often underfunded with aging and poorly maintained HVAC and lighting systems. Most existing school buildings stand to benefit significantly from retrofits in terms of energy, cost, and emissions savings. Ventilation and indoor air quality (IAQ), which are important aspects of a healthy and productive learning environment, can also be enhanced by some energy efficiency measures (EEMs). Packaging energy efficiency and IAQ systems retrofits may represent a golden opportunity to improve performance in this critical building sector.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of Advanced Stirling Convertor Net Heat Input Correlation Methods Using a Thermal Standard

Test hardware used to validate net heat prediction models. Problem: Net Heat Input cannot be measured directly during operation. Net heat input is a key parameter needed in prediction of efficiency for convertor performance. Efficiency = Electrical Power Output (Measured) divided by Net Heat Input (Calculated). Efficiency is used to compare convertor designs and trade technology advantages for mission planning.

Briggs, Maxwell↗

Workload Considerations in Urban Air Mobility

Urban air mobility (UAM) is receiving increased attention in aviation as a system for passenger and cargo-carrying new entrants in urban airspace. In order to develop a safe and efficient system, numerous possible concepts of operation for UAM are being explored throughout industry and research domains, the features and assumptions of which may differ according to near, medium and far term operations. Much of the current research into the development of UAM has dominantly focused on technological and engineering capabilities, such as vehicle development. Although these areas of research are essential to furthering UAM, research into the role of the human operator in UAM is limited. The research described in this paper aims to begin to address this gap by investigating the capabilities and implications of human operators as traffic managers in the UAM system, focusing on near-term UAM operations. A human in the loop air traffic control simulation was used to investigate the effect of UAM traffic density, airspace routes and communication procedures on subjective workload and efficiency-related task performance. Findings indicate that medium and high-density operations were associated with high workload. A reduction in verbal communications through a letter of agreement, and optimized routes, were associated with reduced workload and increased performance efficiency. However, even with these adjustments, reported workload remained high, particularly during the high-density scenario. Future research should focus on the human operator roles and responsibilities, and the amount of involvement, in UAM system management. Particular focus should be directed on the impact of reduced human operator involvement and increased automation, on the safety and efficiency of UAM operations and the integration of UAM with traditional air traffic management.

Edwards, Tamsyn↗

Energy Efficiency and Performance Evaluation of Self-Contained, Medium Temperature, Reach-In Refrigerated Display Cases

This project was part of an effort by Commonwealth Edison Company (ComEd) to evaluate the energy and peak demand saving potential of emerging technologies in the Chicago area. This document focuses on the assessment of energy-efficient, medium-temperature, self-contained refrigerated display cases utilizing environmentally friendly refrigerants. The results of this evaluation will be considered by CLEAResult to develop a new energy efficiency rebate measure for ComEd's incentive programs. This rebate measure will become an addition to the Technical Reference Manual (TRM). In 2016, the United Nations passed the Kigali Montreal Protocol Amendment which placed restrictions on certain types of refrigerants. In compliance with this amendment, the US Environmental Protection Agency (EPA) placed a ban on the manufacture of refrigeration systems using hydrofluorocarbons including R134a starting in January 2020. Although the ban has halted manufacture, the EPA continues to allow the use of these refrigerants. Therefore, it is critical to provide incentives for replacing these refrigerants with other environmentally friendly and energy-efficient alternatives. The energy-efficient refrigerator cases evaluated here (referred to as EE Case A and B) contain environmentally-friendly refrigerants in compliance with the EPA hydrofluorocarbon ban. These consist of natural refrigerant propane (R290), and HFC drop-in hydrofluoroolefin R513a, respectively. These cases also contain other energy-efficient components including efficient lighting, more robust evaporator and condenser fans and different-sized heat exchangers. EE Case A is also built with materials that better insulate the case, which improves energy efficiency. To ascertain the energy efficiency contribution of these design components, the consumption of the evaporator and condenser fan motors, compressor, and lighting/controller were evaluated individually. The medium-temperature, self-contained reach-in refrigerated display case was selected due to its widespread use in convenience stores and small supermarkets. Self-contained refrigeration has also seen increased use in restaurants due to curbside pickup during the COVID-19 pandemic. For this study, the refrigerated display cases' performance was evaluated in a controlled environmental chamber at representative indoor dry-bulb and humidity conditions found in supermarkets within ComEd's service territory climate zone. The test method used in this project was foundationally inspired by the ANSI/ASHRAE 72-2018 method of testing. However, modifications to the ANSI/ASHRAE test methodology were implemented to better represent customer operation of the units. In addition to the indoor supermarket conditions, the cases were also evaluated at the "upper target," or environmental conditions used in ANSI/ASHRAE 72-2018. The case total power and case components were metered to obtain their daily power (kW) and energy consumption(kWh). The cases were filled with thermal filler mass to replicate thermal mass of product loading. Additionally, product simulators were used to provide product temperature information. Door actuators were mounted to each of the cases' three doors to replicate regular door openings and effects of shopper traffic.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Minimizing development costs for efficient many-core visualization using MCD3

Scientific visualization software increasingly needs to support many-core architectures. However, development time is a significant challenge due to the breadth and diversity of both visualization algorithms and architectures. With this work, we introduce a development environment for visualization algorithms on many-core devices that extends the traditional data-parallel primitive (DPP) approach with several existing constructs and an important new construct: meta-DPPs. We refer to our approach as MCD 3 — Meta-DPPs, Convenience routines, Data management, DPPs, and Devices. The twin goals of MCD 3 are to reduce developer time and to deliver efficient performance on many-core architectures, and our evaluation considers both of these goals. For development time, we study 57 algorithms implemented in the VTK-m software library and determine that MCD 3 leads to significant savings. For efficient performance, we survey ten studies looking at individual algorithms and determine that the MCD 3 hardware-agnostic approach leads to performance comparable to hardware-specific approaches: sometimes better, sometimes worse, and better in the aggregate. In total, we find that MCD 3 is an effective approach for scientific visualization libraries to support many-core architectures.

97 MATHEMATICS AND COMPUTING↗

Heavy-Duty Nonroad Material Handler Electrification Part 2: Energy Efficiency and Performance Evaluation

Decarbonization efforts achieved through electrification in nonroad mobile machinery can realize a reduction in fuel consumption of more than 20%, thanks to concepts familiar to light-duty passenger vehicles. This case study compares the results of a hybrid-electric material handler to its conventional counterpart, utilizing machine-specific drive cycles presented in part one of this paper series. The hybrid prototype features an extended-range electric vehicle (EREV) powertrain that demonstrated substantial energy efficiency improvements. Specifically, there was a reduction in equivalent fuel consumption of 75% when operating in electric-only mode, and 33% when maintaining the battery by charging with an on-board generator. Together, the efficiency improvements can be extrapolated over a low-intensity, 8-h shift characterized by significant idle time and highly dynamic engine load for a 47% reduction in net energy consumption. Key technologies that led to this improvement included engine downsizing and decoupling, regenerative braking, and an electrohydraulic pump unit with advanced controls. Finally, his study explains details of the powertrain architecture and subsystems that were implemented on a demonstration vehicle, control strategies used to meet project goals, and an analysis of energy consumption from testing on a closed course. Also included in this study is a discourse on comparison metrics that can be used for quantifying the energy consumption differences between hybrid-electric and conventional diesel powertrains in nonroad mobile machinery.

25 ENERGY STORAGE↗

Effects of ambient temperature on electric vehicle range considering battery Performance, powertrain Efficiency, and HVAC load

Here, this study investigates the impact of ambient temperature on the range of electric vehicles (EVs) by analyzing its effects on usable battery energy (UBE), heating, ventilation, and air conditioning (HVAC) energy consumption, and powertrain energy losses. Chassis dynamometer tests within a thermal chamber were conducted under various temperature conditions to investigate these impacts. The results indicate that lower temperatures lead to a decrease in UBE for lithium-ion batteries in EVs. At −18 °C, the UBE exhibited reductions of 4---8 % compared to the UBE at 22 °C. Battery thermal management strategies significantly affected the UBE loss, with different strategies resulting in distinct UBE reductions. HVAC energy consumption, especially for interior heating, proved to be the most dominant variable affecting EV driving range. Larger discrepancies between the HVAC target temperature (22 °C) and the ambient temperature increased HVAC energy usage. The type of HVAC system also influenced energy consumption, where EVs equipped with heat pumps demonstrated lower energy consumption for heating compared to those relying solely on resistance heaters. Ambient temperature also influenced motor energy consumption due to increased frictions, powertrain losses and tire rolling resistance at lower temperatures; consequently, regenerative braking energy decreased in cold conditions. Combining these effects influenced the overall energy consumption and driving range of EVs. At −18 °C, the driving range saw a substantial decrease of up to 60 % compared to 22 °C, while a slight decrease was observed at 35 °C.

Ambient Temperature↗

Force-Triggered, Biobased Sealants for Prefabricated Building Components: Toward Improved Efficiency and Performance

The prefabricated building construction industry has made extensive progress in expediting the manufacture of prefabricated components at off-site plants. However, the sealing of joints between these components, which is crucial to ensuring the weatherproofing of the assembly, still represents a labor-intensive, on-site effort that relies on the manual installation of tapes and caulks. Here, to reduce work at the jobsite and improve the airtightness and waterproofness of building envelopes, we developed a sealant that can be installed at the plant on prefab components and have the curing reaction triggered at the jobsite by using microencapsulation technology to separate the reactive agents. A series of force-triggered, high-strength, and fast-curing sealants derived from biobased feedstocks were developed, which consist of a biobased epoxy agent encapsulated in a polymer shell, embedded in a biobased amine curing agent. The shell of the microcapsules allows an effective separation of the reactive species in the one-part sealant, allowing shelf stability to an otherwise fast-curing system as well as improving the hydrophobicity of the whole system. When force activates and breaks the microcapsules, the highly reactive epoxy and amine mix and cure, exhibiting peel strength values of up to 143 ppi (pounds per inch). The hydrophobicity of the sealants allows them to retain up to 94% of the original peel strength after complete submersion in water for 24 h, showcasing the water resistivity of the sealant system. The open-air shelf stability of the sealant complex is demonstrated by the obtention of peel strength values of ∼16 ppi when triggering the curing reaction even after being exposed 8 months to open air and humidity. The successful on-demand triggering of curing reactions and the shelf stability provide efficacy of these force-triggered sealants for installation on prefabricated components, storage for months prior to delivery, and assembly at a jobsite. These force-triggered biobased sealants for prefabricated buildings can result in lower installation time and cost and better performance than tapes and caulks at the jobsite.

biobased↗

High-Performance/-Precision/-Z(HPPZ) Scintillator Grids via Advanced Electrochemistry. Phase I – Project # 20210572MFR- Mid year review [Slides]

Scintillation grids with improved imaging resolution in time and space, are required for future mission needs at various facilities (pRad user station, LANSCE, DARHT, Scorpius etc). Current technologies use inorganic crystal scintillators, which are positioned within a high-Z scintillator septa. Dense and high-Z materials are optimal for gamma-ray detection making them promising candidates for development of high -performance/-precision/-Z (HPPZ) scintillator grids. The current resolution of standard chemical etching and fabrication processes of high-Z materials is very low, leading to undesired undercutting and ultimately reducing crystal performance efficiency. Goals are to: Perform initial feasibility studies with the aim of producing complex parts for applications with difficult-to-process high-Z material; Use of pulse and pulse-reverse electrochemical methods on additive approaches to produce high-precision Au and Re scintillator grids at a small scale; and, Follow up in Phase II with the delivery of a large-scale scintillator grid of the best material candidate with unprecedented properties for LANL needs determined in Phase I.

36 MATERIALS SCIENCE↗