Search NASASearch

SEARCH · Search NASA

Results for “performance evaluation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

528 records · Page 2

Evaluation of Anomaly Detection Capability for Ground-Based Pre-Launch Shuttle Operations

This chapter will provide a thorough end-to-end description of the process for evaluation of three different data-driven algorithms for anomaly detection to select the best candidate for deployment as part of a suite of IVHM (Integrated Vehicle Health Management) technologies. These algorithms were deemed to be sufficiently mature enough to be considered viable candidates for deployment in support of the maiden launch of Ares I-X, the successor to the Space Shuttle for NASA's Constellation program. Data-driven algorithms are just one of three different types being deployed [3],[5]. The other two types of algorithms being deployed include a "rule-based" expert system, and a "model-based" system. Within these two categories, the deployable candidates have already been selected based upon qualitative factors such as flight heritage. For the rile-based system, SHINE (Spacecraft High-speed Inference Engine) has been selected for deployment, which is a component of BEAM (Beacon-based Exception Analysis for Multimissions) [4], a patented technology developed at NASA's JPL (Jet Propulsion Laboratory) and serves to aid in the management and identification of operational modes. For the "model-based" system, a commercially available package developed by QSI (Qualtech Systems, Inc.), TEAMS (Testability Engineering and Maintenance System) [1] has been selected for deployment to aid in diagnosis. In the context of this particular deployment, distinctions among the use of the terms "data-driven," "rule-based," and "model-based," call found in [5]. Although there are three different categories of algorithms that have been selected for deployment, our main focus in this chapter will be on the evaluation of three candidates for data-driven anomaly detection. These algorithms will be evaluated upon their capability for robustly detecting incipient faults or failures in the ground-based phase of pre-launch space shuttle operations, rather than based oil heritage as performed in previous studies [5]. Robust detection will allow for the achievement of pre-specified minimum false alarm and/or missed detection rates in the selection of alert thresholds. All algorithms will also be optimized with respect to all of these same criteria. Our study relies upon the use of Shuttle data to act as was a proxy for and in preparation for application to Ares I-X data, which uses a very similar hardware platform for the subsystems that are being targeted (TVC - Thrust Vector Control subsystem for the SRB (Solid Rocket Booster)).

False Alarms

Evaluation of Fatigue Damage Accumulation Functions for Delamination Initiation and Propagation

The present report follows on the cohesive fatigue damage model methodology proposed in NASA-TP-2018-219838. In that report, an empirical function describing the incremental damage due to cyclic loading was used to calculate fatigue damage within a cohesive formulation. The form of the function was developed such that, when integrated at a constant stress amplitude from no damage to failure, it produces a life versus load response that is consistent with an S-N diagram. Therefore, the parameters of the damage model could be obtained by fitting the model predictions to an S-N diagram. The finite element analyses performed demonstrate that the cohesive fatigue accumulation function provides a link between the S-N diagram that describes crack initiation, and the Paris law that characterizes the rate of crack propagation. However, when the model was proposed, it was not known whether the form of the damage accumulation function associated with a desired S-N diagram is unique and, if not, if the link between S-N and the Paris law is unique and independent of the fatigue function selected. In the effort described herein, several alternative forms of the damage function that reproduce the desired features of S-N diagrams were found and evaluated. The effects of each of these functions on the predicted parameters of the Paris law and the propagation threshold are discussed. The results indicate that the predicted exponent m of the Paris law is indeed independent of the damage accumulation function. However, different functions predict different values for the pre-factor C of the Paris law. Therefore, the proper damage accumulation function must be selected by comparison with experiments. One of the new damage accumulation functions proposed herein was found to be particularly useful for analysis because of the ease with which the model parameters can be determined with a minimal amount of experimental information. The effectiveness of the proposed methodology and damage function was demonstrated by conducting analyses of a double cantilever beam test, a mixed-mode bending test, and a three-point bending test of a skin/doubler specimen. The results indicate that the same set of model parameters can provide accurate predictions of the rate of fatigue crack propagation for a variety of material interfaces, mode mixities, load levels, and stress ratios.

DKIN/Stiffener Debonding

Nickel hydrogen battery expert system

The Hubble Telescope Battery Testbed at MSFC uses the Nickel Cadmium (NiCd) Battery Expert System (NICBES-2) which supports the evaluation of performance of Hubble Telescope spacecraft batteries and provides alarm diagnosis and action advice. NICBES-2 provides a reasoning system along with a battery domain knowledge base to achieve this battery health management function. An effort is summarized which was used to modify NICBES-2 to accommodate Nickel Hydrogen (NiH2) battery environment now in MSFC testbed. The NICBES-2 is implemented on a Sun Microsystem and is written in SunOS C and Quintus Prolog. The system now operates in a multitasking environment. NICBES-2 spawns three processes: serial port process (SPP); data handler process (DHP); and the expert system process (ESP) in order to process the telemetry data and provide the status and action advice. NICBES-2 performs orbit data gathering, data evaluation, alarm diagnosis and action advice and status and history display functions. The adaptation of NICBES-2 to work with NiH2 battery environment required modification to all of the three component processes.

Shiva, Sajjan G.

GPS on-orbit battery performance

Three batteries designed for the GPS system were evaluated. The batteries were wired together, and during the eclipse period were discharged through parallel diodes into a boost converter which then boosted the battery voltage up to the totally regulated bus voltage. Each battery, with a system life of approximately five years, had its own charger. During testing the battery was maintained or used on trickle charge. Data are presented for the battery capacity during the reconditioning. Raw data for each eclipse period and calculations for the average discharge voltage for each battery are given. Thermal cycling for one of the batteries and reconditioning cycles and regimes for all of the batteries are discussed. A reconditioning discharge curve is also given. The problem of temperature cycling in one of the batteries was resolved by redesigning the battery radiator system.

Kasten, J. L.

Evaluation of Ultrasonic Battery Inspection Techniques

Lithium metal batteries are prone to subtle defects such as internal dendrites, which can cause internal short circuits and lead to catastrophic ignition. These defects are often undetectable by battery management systems, prompting the need to advance nondestructive evaluation (NDE) techniques for battery applications. In this work, two ultrasonic approaches were compared to establish their relative merits for this application: local ultrasonic resonance spectroscopy, and guided wave ultrasound. Benchtop experiments on batteries seeded with lithium chips emulating plating were used to demonstrate the two techniques. The results show the ability to identify and map local changes in cell structure.

Ultrasound

Evaluation of Ultrasonic Battery Inspection Techniques

Lithium metal batteries are prone to subtle defects such as internal dendrites, which can cause internal short circuits and lead to catastrophic ignition. These defects are often undetectable by battery management systems, prompting the need to advance nondestructive evaluation (NDE) techniques for battery applications. In this work, two ultrasonic approaches were compared to establish their relative merits for this application: local ultrasonic resonance spectroscopy, and guided wave ultrasound. Benchtop experiments on batteries seeded with lithium chips emulating plating were used to demonstrate the two techniques. The results show the ability to identify and map local changes in cell structure.

Ultrasound

Dynamic Regulation of Sub-Atmospheric Pressure for Constant and Cyclic Gas Loads During Testing of Spacesuit Components

New iterations of the various subsystems within the spacesuit will benefit from a new sorbent technology. For example, sorbents used in the Trace Contaminant Control (TCC) and the Rapid Cycle Amine (RCA) systems within the Exploration Portable Life Support System (xPLSS), part of the Extra-Vehicular Mobility Unit (xEMU). For proper validation, the sub-atmospheric pressure needs to be maintained within a simulated 2 ft 3 spacesuit volume. The traditional approach, which involves placing the entire vent loop within a hypobaric chamber, is not practical for the widespread testing of components and prototypes, as these specialized chambers are costly and not widely available. A two-stage regulator based sub-atmospheric pressure system is presented in this work. The method regulates the pressure based on pressure differentials between the pressure regulation pump, the test system, and the ambient environment. The performance of this system is demonstrated using data collected during a 150+ hour non-regenerative TCC sorbent evaluation, several 24-hour regenerative TCC sorbent evaluations with different regeneration cycles, and an 8-hour RCA sorbent evaluation, all under xEMU operating conditions. For regulation, the inlet regulator was set to propagate a small leak to increase the stability of the system as the gas load from the testing system changes. It was also found that controlling the input flow rate that replaces the material lost during regeneration is critical for ensuring the stability of the system. This system provided excellent pressure regulation, without adjustments, for constant loads during shorter time evaluations (hours), while longer time evaluations (days) are easily obtainable with periodic regulator adjustments. A second method is under development to address longer-term stability and to automate pressure regulation. It will incorporate flow and pressure measurements to dynamically control a set of electronically controlled proportional valves for adjusting the pumping speed and air bleed supply.

Nicholas F Materer

The Flight Performance of the Galileo Orbiter USO

Results are presented from an analysis of radio metric data received by the DSN stations from the Galileo spacecraft using an Ultrastable Oscillator (USO) as a signal source. These results allow the health and performance of the Galileo USO to be evaluated, and are used to calibrate this Radio Science instrument and the data acquired for Radio Science experiments such as the Red-shift Observation, Solar Conjunction, and Jovian occultations. Estimates for the USO-referenced spacecraft-transmitted frequency and frequency stability were made for 82 data acquisition passes conducted between launch (October 1989) and November 1991. Analyses of the spacecraft-transmitted frequencies show that the USO is behaving as expected. The USO was powered off and then back on in August 1991 with no adverse effect on its performance. The frequency stabilities measured by Allan deviation are consistent with expected values due to thermal wideband noise and the USO itself at the appropriate time intervals. The Galileo USO appears to be healthy and functioning normally in a reasonable manner.

D D Morabito

Research on battery-operated electric road vehicles

Mathematical analysis of battery-operated electric vehicles is presented. Attention is focused on assessing the influence of the battery on the mechanical and dynamical characteristics of dc electric motors with series and parallel excitation, as well as on evaluating the influence of the excitation mode and speed control system on the performance of the battery. The superiority of series excitation over parallel excitation with respect to vehicle performance is demonstrated. It is also shown that pulsed control of the electric motor, as compared to potentiometric control, provides a more effective use of the battery and decreases the cost of recharging.

Varpetian, V. S.

Pocket nickel cadmium cell and battery evaluation

The Nickel Cadmium 129-ampere hour cell was tested in order to characterize the cell under controlled conditions. Results of charge characterization and discharge characterization are reported. Ampere hour efficiency, open circuit stand, and cycle life operation results are included. The battery is briefly described.

Lear, J. W.

Development of nickel hydrogen battery expert system

The Hubble Telescope Battery Testbed employs the nickel-cadmium battery expert system (NICBES-2) which supports the evaluation of performances of Hubble Telescope spacecraft batteries and provides alarm diagnosis and action advice. NICBES-2 also provides a reasoning system along with a battery domain knowledge base to achieve this battery health management function. An effort to modify NICBES-2 to accommodate nickel-hydrogen battery environment in testbed is described.

Shiva, Sajjan G.

Seeking & Evaluating Applications of SAWs (SEASAWs)

Surface Acoustic Wave sensors (SAWs) offer a battery less, wireless, passive, noninvasive, durable means of sensing which might be appealing to many fields in space technology. Developments in many aspects of SAWs including the miniaturization of associated hardware, improvements in interrogation and device fabrication / characterization allow for the use of SAWs in many aerospace settings where traditional sensors may have sufficed but SAWs might enhance. In order to place this technology in relevant environments, an inherent understanding of operation and capabilities must be understood. With the many possibilities of SAWs in their implementation, breaking down their tradeoffs and primary systems allows for their application.

Michael Szostak