Search NASA⌕ Search

SEARCH · Search NASA

Results for “phase calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

PMT calibration for the JSNS^2-II far detector with an embedded LED system

The JSNS^2-II (the second phase of JSNS^2, J-PARC Sterile Neutrino Search at J-PARC Spallation Neutron Source) is an experiment aimed at searching for sterile neutrinos. Here, this experiment has entered its second phase, employing two liquid scintillator detectors located at near and far positions from the neutrino source. Recently, the far detector of the experiment has been completed and is currently in the calibration phase. The following properties of all functioning Photo-Multiplier-Tubes (PMTs) to detect the neutrino events in the far detector have been calibrated: PMT gain, its dependence of supplied High Voltage (HV), Peak-to-Valley (PV), and signal timing. This paper presents a detailed description of the calibration process utilizing the LED system. The LED system of the far detector uses two Ultra-Violet (UV) LEDs, which are effective in calibrating all of the PMTs at once. The UV light is converted into the visible light wavelengths inside liquid scintillator via the wavelength shifters, providing pseudo-isotropic light. To achieve a good energy resolution for physics events, a relative gain adjustment of up to 10% is required for all functioning PMTs. This will be achieved using the HV curves measured and the results of the LED calibration. The Peak-to-Valley (PV) ratio values, which distinguish the single photo-electron signal from the pedestal, are similar to those from the production company. Additionally, the precision of the PMT signal timing is measured to be 2.1 ns. This meets the event reconstruction requirement of 10 ns.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Phase identification using co‐association matrix ensemble clustering

Calibrating distribution system models to aid in the accuracy of simulations such as hosting capacity analysis is increasingly important in the pursuit of the goal of integrating more distributed energy resources. The recent availability of smart meter data is enabling the use of machine learning tools to automatically achieve model calibration tasks. This research focuses on applying machine learning to the phase identification task, using a co‐association matrix‐based, ensemble spectral clustering approach. The proposed method leverages voltage time series from smart meters and does not require existing or accurate phase labels. This work demonstrates the success of the proposed method on both synthetic and real data, surpassing the accuracy of other phase identification research.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A CALPHAD-informed approach to modeling constituent redistribution in Zr-based metallic fuels using BISON

Here, a CALPHAD-informed (Computer Coupling of Phase Diagrams and Thermochemistry) constituent redistribution model was developed for Zr-based metallic fuels and incorporated into the BISON fuel performance code. Three uncertain model parameters associated with β and γ phase kinetics were calibrated using integral test data from U-Zr fuel elements irradiated in Experimental Breeder Reactor II. The calibrated constituent redistribution model was shown to predict the behavior of U-Zr fuels with excellent accuracy. Model predictions for U-Pu-Zr fuels were physically reasonable but less accurate. Reduction of uncertainties in the ternary phase transition temperatures and collection of kinetic data for the ζ phase are expected to improve the model’s ternary predictions. Finally, the new model was coupled to existing thermomechanics models in BISON to simulate irradiation of an entire U-Zr fuel element, demonstrating its ability to accurately predict the behavior of U-Zr fuels with realistic geometries and mesh resolutions at the engineering scale.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The effects of stress, temperature and facet structure on growth of { 10 1 ¯ 2 } twins in Mg: a molecular dynamics and phase field study

The present study focuses on the roles of structure, stress and temperature on the mobility of facets bounding twin domains and on the overall impact on the growth kinetics of { 10 1 ¯ 2 } twins in Mg. We first use molecular dynamics simulations (MD) to study the relationship between interface structures, stress, temperature and mobility. As facets can exhibit distinct atomic scale structures, we also quantify the effect of stress relaxation mediated by misfit dislocations on the mobility of the basal-prismatic interface. The information gathered for ten different facets is used to calibrate an anisotropic phase field model predicting the effects of temperature and stress on the kinetics and shape of a growing { 10 1 ¯ 2 } 3D twin, by comparison with MD data. The comparative analysis suggests that, as compared to simulations of individual facets, the effective mobility of facets can be significantly different during growth of a 3D twin. This can be attributed to the complex three-dimensional internal stress state of the twin and to coupling in facet motion triggered by facet junctions. As such, by directly fitting both the twin growth kinetics and morphology as predicted by MD for different stresses and temperatures, we can identify a limited set of rate-limiting facets that control twin growth and morphology, and measure their effective mobility.

36 MATERIALS SCIENCE↗

Automated Fitting of a Semi-empirical Multiphase Equation of State for Carbon

The equation of state (EOS) of carbon is important in high explosive, geophysical, and inertial confinement fusion applications. Within the semi-empirical Sesame framework, the EOS of each phase is represented by a sum of cold, vibrational, and thermal electronic Helmholtz free energy contributions. Each phase has ~5-10 independent parameters that are adjusted to reproduce single-phase data (e.g., thermal expansion, isothermal compression) as well as experimentally- and computationally- derived phase boundaries. Manual calibration of the full multiphase EOS is arduous. We present our progress in development of automated EOS parameterization based on minimization of an objective function. Here, this function encodes deviation of model EOS results from experimental/computational benchmarks. Optimization is implemented as a combination of global (particle swarm) and local optimization techniques.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Incorporating dynamic recrystallization into a crystal plasticity model for high-temperature deformation of Ti-6Al-4V

During hot deformation of (α + β) titanium alloys, the simultaneous action of strain and temperature in the (α + β) regime facilitates dynamic recovery, dynamic recrystallization (DRX), and phase transformations via non-equilibrium paths. DRX is manifested in the form of fine recrystallized α or β grains. Here, in the present study, a two-phase crystal plasticity finite element framework (CP-DRX) has been developed which incorporates DRX kinetics into the crystal plasticity (CP) model to predict the flow characteristics of Ti-6Al-4V alloys during thermo-mechanical processing. The CP slip system parameters, as well as elastic properties from both α and β phases of Ti, are calibrated for different strain rate conditions. An EBSD-informed two-phase microstructure representation has been utilized in the CP-DRX framework to explore the time-dependent evolution of DRX microstructure and crystal orientation for different strain rate conditions. The proposed CP-DRX can capture the evolution of crystal orientation and plastic flow stress–strain response of polycrystalline Ti-6Al-4V during the deformation process. Furthermore, the proposed model is able to capture the softening behavior, observed in average stress–strain response from experiments performed using a Gleeble thermomechanical simulator and predict the recrystallization texture.

(α+ β)-Titanium (Ti) Alloys↗

Utilizing integrated neutron diffraction and elastoplastic self-consistent crystal plasticity model to quantitatively assess the strengthening mechanism in Al–12.5Ce and Al–12.5Ce–0.4Mg alloys

An integrated in-situ neutron diffraction and elastic plastic self-consistent crystal plasticity (EPSC-CP) modeling scheme is performed on a binary Al–12Ce alloy and a ternary Al–12Ce–0.4Mg alloys. Using this scheme, the constitutive parameters, i.e. elastic constants and slip system parameters of individual phases can be calibrated which can be used in microstructure-based CP models to predict materials performance. From this study, it is shown that the elastic constants of Al 11 Ce 3 intermetallics calculated from density function theory calculation in the literature are rather accurate. When applied to the EPSC-CP model, the lattice strains of both the binary and ternary alloys are correctly predicted as compared with experiments, and large lattice strain differences between Al (100) plane and Al 11 Ce 3 (010) plane are demonstrated. The slip system parameters calibrated by the scheme shows that the addition of 0.4 wt% Mg in the alloy has little influence on the critical resolved shear stress of initial dislocation glide in the Al matrix which caused plastic yield in the material. This can be explained by the very dilute Mg solute content in the Al solid solution, causing large spacing of Al–Mg lattice misfit sites and little impact on resistance of dislocation glide at initial yield. The 0.4 wt% Mg addition, on the other hand, has a large influence on the hardening term in the slip system parameters, indicating those Al–Mg misfit sites do help dislocation accumulation during the deformation. The impact of dilute Mg addition on the Al slip system parameters is also reflected in the flow behavior of the ternary alloy: little impact on the yield stress, but a large impact on working hardening and tensile strength of the materials which is consistent with the literature.

36 MATERIALS SCIENCE↗

Inference of strength and phase transition kinetics in dynamically-compressed tin

Dynamic compression experiments in condensed matter are of interest in part because they provide opportunities to examine material response under extreme conditions; however, the inference of material behavior from dynamic experiments is challenging in the presence of phase transitions exhibiting kinetic processes. Demonstrating an approach to quantitative interpretation of such dynamic experiments, here we present a Bayesian model calibration of strength and phase transformation parameters to data drawn from pulsed power and gas gun shot experiments. The posterior predictions of the Bayesian model capture the experimental measurements and account for the various uncertainties in the experimental configurations. This holistic approach to model calibration utilizing multiple types of experimental data identifies important cross correlations among kinetics, strength, and the phase boundary. Improved insight into potential sources of current model form error is provided by comparing the differences between calibrations against different subsets of the experimental data.

42 ENGINEERING↗

Optical calibration of the SNO+ detector in the water phase with deployed sources

SNO+ is a large-scale liquid scintillator experiment with the primary goal of searching for neutrinoless double beta decay, and is located approximately 2 km underground in SNOLAB, Sudbury, Canada. The detector acquired data for two years as a pure water Cherenkov detector, starting in May 2017. During this period, the optical properties of the detector were measured in situ using a deployed light diffusing sphere, with the goal of improving the detector model and the energy response systematic uncertainties. The measured parameters included the water attenuation coefficients, effective attenuation coefficients for the acrylic vessel, and the angular response of the photomultiplier tubes and their surrounding light concentrators, all across different wavelengths. Finally, the calibrated detector model was validated using a deployed tagged gamma source, which showed a 0.6% variation in energy scale across the primary target volume.

47 OTHER INSTRUMENTATION↗

A parametric model for self-interacting dark matter halos

Abstract We propose a parametric model for studying self-interacting dark matter (SIDM) halos. The model uses an analytical density profile, calibrated using a controlled N-body SIDM simulation that covers the entire gravothermal evolution, including core-forming and -collapsing phases. By normalizing the calibrated density profile, we obtain a universal description for SIDM halos at any evolution phase. The model allows us to infer properties of SIDM halos based on their cold dark matter (CDM) counterparts. As a basic application, we only require two characteristic parameters of an isolated CDM halo atz = 0. We then extend the model to incorporate effects induced by halo mass changes, such as major mergers or tidal stripping, making it applicable to both isolated halos and subhalos. The parametric model is tested and validated using cosmological zoom-in SIDM simulations available in the literature.

Astronomy & Astrophysics↗

Design and development of the magnetic diagnostic systems for the first operational phase of the SMART tokamak

A set of magnetic diagnostics has been designed, manufactured, and calibrated for the first operational phase of the small aspect ratio tokamak. The sensor suite comprises of Rogowski coils; 2D magnetic probes; and poloidal, saddle, and diamagnetic flux loops. Here, a set of continuous Rogowski coils has been manufactured for the measurement of plasma current and induced eddy currents in conductive elements. A set of flux loops and magnetic probes will be used as input for the reconstruction of the magnetohydrodynamic equilibrium. The quantity and position of these sensors have been verified to be sufficient with synthetic equilibrium reconstructions using the equilibrium fitting code and baseline scenarios computed with the Fiesta code. These sensors will also be used as input for the real-time control system, and magnetic probes will be used for the detection of plasma instabilities. The calibration procedure for the magnetic probes is described, and the results are shown. The signal conditioning and data acquisition systems are described.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Stabilization of the 81-channel coherent beam combination using machine learning

We develop a rapidly converging algorithm for stabilizing a large channel-count diffractive optical coherent beam combination. An 81-beam combiner is controlled by a novel, machine-learning based, iterative method to correct the optical phases, operating on an experimentally calibrated numerical model. A neural-network is trained to detect phase errors based on interference pattern recognition of uncombined beams adjacent to the combined one. Due to the non-uniqueness of solutions in the full space of possible phases, the network is trained within a limited phase perturbation/error range. This also reduces the number of samples needed for training. Simulations have proven that the network can converge in one step for small phase perturbations. When the trained neural-network is applied to a realistic case of 360 degree full range, an iterative scheme exploits random walking at the beginning, with the accuracy of prediction on phase feedback direction, to allow the neural-network to step into the training range for fast convergence. This neural-network-based iterative method of phase detection works tens of times faster than the commonly used stochastic parallel gradient descent approach (SPGD) using a single-detector and random dither when both are tested with random phase perturbations.

Wang, Dan↗

A 24-Channel Digitizer With a JESD204B-Compliant Serial Interface for High-Speed Detectors

In this report a 24-channel application-specific integrated circuit (ASIC) for the readout of high-speed CMOS active pixel sensors for charged particle detection is presented. The chip comprises 24 preamplifiers, 24 distinct 12-bit, 25 MSPS Pipelined analog-to-digital converters (ADCs) with self-calibration, an internal phase-locked loop (PLL), and a 3 Gbps serial interface that conforms to the JESD204B standard. To simplify interfacing with a variety of sensors, the ASIC also includes an automatic offset calibration loop. The high level of integration of the ASIC reduces overall system cost and area, and exploiting the signal characteristics of the image sensor allows the ADC to be optimized for reduced power dissipation. The use of an integrated serializer and an industry standard protocol simplifies integration of the ASIC into a complete camera system. The ASIC, called the High-Speed Image Preprocessor Targeted for Electron Readout, or HIPSTER, with a die area of 64.26 mm 2 , is packaged in a 480-ball grid array (BGA) and is fabricated in 180-nm CMOS technology. HIPSTER achieves typical differential nonlinearity (DNL) < 0.55 LSB, input-referred thermal noise of $114.5 μV-rms, and a bit error rate (BER) of better than 10-14. The power dissipation is 98 mW/channel.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Next Generation Ta-STJ Sensor Arrays for BSM Physics Searches

The Beryllium Electron capture in Superconducting Tunnel junctions (BeEST) experiment uses superconducting tunnel junction (STJ) sensors to search for physics beyond the standard model (BSM) with recoil spectroscopy of the 7 Be EC decay into 7 Li. A pulsed UV laser is used to calibrate the STJs throughout the experiment with ∼20 meV precision. Phase-III of the BeEST experiment revealed a systematic calibration discrepancy between STJs. We found these artifacts to be caused by resistive crosstalk and by intensity variations of the calibration laser. For phase-IV of the BeEST experiment, we have removed the crosstalk by designing the STJ array so that each pixel has its own ground wire. We now also use a more stable UV laser for calibration. The new STJ arrays were fabricated at STAR Cryoelectronics and tested at LLNL and FRIB. They have the same high energy resolution of ∼1-2~eV in the energy range of interest below 100~eV as before, and they no longer exhibit the earlier calibration artifacts. We discuss the design changes and the STJ array performance for the next phase of the BeEST experiment.

Laser Calibration↗

On the Accuracy of the ALMA Flux Calibration in the Time Domain and across Spectral Windows

A diverse array of science goals requires accurate flux calibration of observations with the Atacama Large Millimeter/submillimeter array (ALMA); however, this goal remains challenging due to the stochastic time-variability of the “grid” quasars ALMA uses for calibration. In this work, we use 343.5 GHz (Band 7) ALMA Atacama Compact Array observations of four bright and stable young stellar objects over seven epochs to independently assess the accuracy of the ALMA flux calibration and to refine the relative calibration across epochs. The use of these four extra calibrators allows us to achieve an unprecedented relative ALMA calibration accuracy of ~3%. On the other hand, when the observatory calibrator catalog is not up to date, the Band 7 data calibrated by the ALMA pipeline may have a flux calibration poorer than the nominal 10%, which can be exacerbated by weather-related phase decorrelation when self-calibration of the science target is either not possible or not attempted. We also uncover a relative flux calibration uncertainty between spectral windows of 0.8%, implying that measuring spectral indices within a single ALMA band is likely highly uncertain. We thus recommend various methods for science goals requiring high flux accuracy and robust calibration, in particular, the observation of additional calibrators combined with a relative calibration strategy, and observation of solar system objects for high absolute accuracy.

79 ASTRONOMY AND ASTROPHYSICS↗