Search NASA⌕ Search

SEARCH · Search NASA

Results for “phase noise”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Lifetime-Limited Interrogation of Two Independent 27 Al + Clocks Using Correlation Spectroscopy

Laser decoherence limits the stability of optical clocks by broadening the observable resonance linewidths and adding noise during the dead time between clock probes. Correlation spectroscopy avoids these limitations by measuring correlated atomic transitions between two ensembles, which provides a frequency difference measurement independent of laser noise. Here, we apply this technique to perform stability measurements between two independent clocks based on the 1 S 0 ↔ 3 P 0 transition in 27 Al + . By stabilizing the dominant sources of differential phase noise between the two clocks, we observe coherence between them during synchronous Ramsey interrogations as long as 8 s at a frequency of 1.12 × 10 15 Hz. Here, the observed contrast in the correlation spectroscopy signal is consistent with the 20.6 s 3 P 0 state lifetime and represents a measurement instability of (1.8 ± 0.5) × 10 –16 /√τ/s for averaging periods longer than the probe duration when dead time is negligible.

74 ATOMIC AND MOLECULAR PHYSICS↗

Johnson-noise-limited cancellation-free microwave impedance microscopy with monolithic silicon cantilever probes

Abstract Microwave impedance microscopy (MIM) is an emerging scanning probe technique for nanoscale complex permittivity mapping and has made significant impacts in diverse fields. To date, the most significant hurdles that limit its widespread use are the requirements of specialized microwave probes and high-precision cancellation circuits. Here, we show that forgoing both elements not only is feasible but also enhances performance. Using monolithic silicon cantilever probes and a cancellation-free architecture, we demonstrate Johnson-noise-limited, drift-free MIM operation with 15 nm spatial resolution, minimal topography crosstalk, and an unprecedented sensitivity of 0.26 zF/ √ Hz. We accomplish this by taking advantage of the high mechanical resonant frequency and spatial resolution of silicon probes, the inherent common-mode phase noise rejection of self-referenced homodyne detection, and the exceptional stability of the streamlined architecture. Our approach makes MIM drastically more accessible and paves the way for advanced operation modes as well as integration with complementary techniques.

47 OTHER INSTRUMENTATION↗

Active Cancellation of Servo-Induced Noise on Stabilized Lasers via Feedforward

Many precision laser applications require active frequency stabilization. However, such stabilization loops operate by pushing noise to frequencies outside their bandwidth, leading to large “servo bumps” that can have deleterious effects for certain applications. The prevailing approach to filtering this noise is to pass the laser through a high-finesse optical cavity, which places constraints on the system design. Here, we propose and demonstrate a different approach where a frequency error signal is derived from a beat note between the laser and the light that passes through the reference cavity. The phase noise derived from this beat note is fed forward to an electro-optic modulator after the laser, carefully accounting for relative delay, for real-time frequency correction. With a hertz-line-width laser, we show ≳20 dB noise suppression at the peak of the servo bump (approximately 250 kHz) and a noise-suppression bandwidth of approximately 5 MHz—well beyond the servo bump. By simulating the Rabi dynamics of a two-level atom with our measured data, we demonstrate substantial improvements to the pulse fidelity over a wide range of Rabi frequencies. Here, our approach offers a simple and versatile method for obtaining a clean spectrum of a narrow-line-width laser, as required in many emerging applications of cold atoms, and is readily compatible with commercial systems that may even include wavelength conversion.

47 OTHER INSTRUMENTATION↗

The Fermilab Holometer: A program to measure Planck scale indeterminacy

We propose an experiment at Fermilab to study a conjectured effect called "holographic noise" that may arise from new Planck scale physics: the measured positions of bodies may wander randomly from ideal geodesics of classical relativity, in measurement-dependent directions, by about a Planck length per Planck time. The experiment will search for this holographic jitter in the relation of mass-energy and space-time by looking for correlated phase noise between two neighboring 40 meter interferometers. The goal of the experiment is to provide convincing evidence for or against the hypothesis that relative transverse positions of bodies display this particular new kind of quantum noise, whose power spectrum is independent of frequency and has a spectral density determined only by the Planck time. A positive result of the experiment would be a major step forward in understanding the emergence of space time and mass-energy from a unified theory of spacetime and quantum mechanics. A negative result will impact the macroscopic interpretation of unified theories.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Integrated optical frequency division for microwave and mmWave generation

Abstract The generation of ultra-low-noise microwave and mmWave in miniaturized, chip-based platforms can transform communication, radar and sensing systems 1–3 . Optical frequency division that leverages optical references and optical frequency combs has emerged as a powerful technique to generate microwaves with superior spectral purity than any other approaches 4–7 . Here we demonstrate a miniaturized optical frequency division system that can potentially transfer the approach to a complementary metal-oxide-semiconductor-compatible integrated photonic platform. Phase stability is provided by a large mode volume, planar-waveguide-based optical reference coil cavity 8,9 and is divided down from optical to mmWave frequency by using soliton microcombs generated in a waveguide-coupled microresonator 10–12 . Besides achieving record-low phase noise for integrated photonic mmWave oscillators, these devices can be heterogeneously integrated with semiconductor lasers, amplifiers and photodiodes, holding the potential of large-volume, low-cost manufacturing for fundamental and mass-market applications 13 .

Science & Technology - Other Topics↗

Relation between sampling, sensitivity and precision in strain mapping using the Geometric Phase Analysis method in Scanning Transmission Electron Microscopy

The sensitivity and the precision of the Geometric Phase Analysis (GPA) method for strain characterization is a topic widely discussed in the literature and is usually difficult to quantify. Indeed, the GPA precision is intricately linked to the resolution of the strain maps defined when masking the periodic reflections in Fourier space. In this study an additional parameter, sampling, is proposed to be analyzed regarding the precision of GPA by developing the concept of a phase noise in the GPA equations. Both experimentally and theoretically, the following article demonstrates how the precision, and the sensitivity of the GPA method is improved when using a larger pixel spacing to record an electron micrograph in Scanning Transmission Electron Microscopy (STEM). In conclusion, the counterintuitive concept of increasing the field of view to improve the GPA precision results in an extension of the application of strain characterization methods in STEM towards low deformation levels.

47 OTHER INSTRUMENTATION↗

Resolution of 100 photons and quantum generation of unbiased random numbers

Macroscopic quantum phenomena, such as observed in superfluids and superconductors, have led to promising technological advancements and some of the most important tests of fundamental physics. At present, quantum detection of light is mostly relegated to the microscale, where avalanche photodiodes are very sensitive to distinguishing single-photon events from vacuum but cannot differentiate between larger photon-number events. Beyond this, the ability to perform measurements to resolve photon numbers is highly desirable for a variety of quantum information applications including computation, sensing, and cryptography. True photon-number resolving detectors do exist, but they are currently limited to the ability to resolve on the order of 10 photons, which is too small for certain proposals. In this work, we extend photon measurement into the mesoscopic regime by implementing a detection scheme based on multiplexing highly quantum-efficient transition-edge sensors to accurately resolve photon numbers between zero and 100. Further, we then demonstrate the use of our system by implementing a quantum random number generator with no inherent bias. This method is based on sampling a coherent state in the photon-number basis and is robust against environmental noise, phase and amplitude fluctuations in the laser, loss and detector inefficiency as well as eavesdropping. Beyond true random number generation, our detection scheme serves as a means to implement quantum measurement and engineering techniques valuable for photonic quantum information processing.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Edge supercurrent reveals competition between condensates in a Weyl superconductor

In topological materials, the edge states are readily distinguished from the bulk states. The situation where a topological semimetal becomes superconducting so that Cooper pairs occupy both the bulk and the edge states is not well understood. In particular, we do not know if we can force their pairing symmetries to be different. Here we show that, when supercurrent is injected into the superconducting Weyl semimetal MoTe 2 from Nb contacts, the invasive s-wave pairing potential from Nb is incompatible with the intrinsic Cooper pair condensate in MoTe 2 . This incompatibility leads to strong stochasticity in the switching current and an unusual anti-hysteretic behaviour in the current–voltage loops. There is also an asymmetry in the edge oscillations where, as the magnetic field crosses zero, the phase noise switches from one with a noisy spectrum to one that is noise free. Furthermore, using the noise spectrum as a guide, we track the anomalous features to field-induced switching of the device gap function between s-wave symmetry and the unconventional symmetry intrinsic to MoTe 2 . We infer that the behaviour of the gap function along the edges is different from that in the bulk.

Superconducting properties and materials↗

A novel Doppler backscattering (DBS) system to simultaneously measure radio frequency plasma fluctuations and low frequency turbulence

A novel quadrature Doppler Backscattering (DBS) system has been developed and optimized for the E-band (60–90 GHz) frequency range using either O-mode or X-mode polarization in DIII-D plasmas. In general, DBS measures the amplitude of density fluctuations and their velocity in the lab frame. The system can simultaneously monitor both low-frequency turbulence (f < 10 MHz) and radiofrequency plasma density fluctuations over a selectable frequency range (20–500 MHz). Detection of high-frequency fluctuations has been demonstrated for low harmonics of the ion cyclotron frequency (e.g., 2f ci ~ 23 MHz) and externally driven high-frequency helicon waves (f = 476 MHz) using an adjustable frequency down conversion system. Importantly, this extends the application of DBS to a high-frequency spectral domain while maintaining important turbulence and flow measurement capabilities. This unique system has low phase noise, good temporal resolution (sub-millisecond), and excellent wavenumber coverage (k θ ~ 1–20 cm –1 and kr ≲ 30 cm –1 ). As a demonstration, localized internal DIII-D plasma measurements are presented from turbulence (f ≤ 5 MHz), Alfvenic waves (f ~ 6.5 MHz), ion cyclotron waves (f ≥ 20 MHz), as well as fluctuations around 476 MHz driven by an external high-power 476 MHz helicon wave antenna. In the future, helicon measurements will be used to validate GENRAY and AORSA modeling tools for prediction of helicon wave propagation, absorption, and current drive location for the newly installed helicon current drive system on DIII-D.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Compensation of Anisotropy in Spin Hall Devices for Neuromorphic Applications

Spintronic nano-oscillators and diodes with reduced nonlinearity benefit from low phase noise and improved device properties. Moreover, they could offer key advantages for realizing neuromorphic applications, such as spike-based neurons and frequency multiplexing in neural networks. Here, in this work, we experimentally demonstrate the reduction in nonlinearity of a spin Hall nano-oscillator (SHNO) by compensation of its effective magnetic anisotropy. The study involves optimization of Co/Ni multilayer growth to achieve the compensation, followed by spin-diode measurements on patterned microstrips to quantify their anisotropy. The relationship between the second- (H k 2 = 0.47 mT) and first-order ($H^{eff}_{k_1}$ = -0.8 mT) anisotropy fields reveals the existence of an easy cone, thereby validating the presence of compensation. Furthermore, we demonstrate a compensated spin diode that has a fixed frequency when the input power is varied. We then study the current-induced auto-oscillation properties of SHNOs on compensated films by patterning nanoconstrictions of 200 and 100 nm wide. The invariance of the resonance frequency and linewidth of the compensated SHNO with applied dc current indicates the absence of nonlinearity. This independence is maintained irrespective of the applied external fields and their orientations. The compensated SHNO obtained has a linewidth of 1.1 MHz and a peak output power of up to 1 pW/MHz.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Data Quality Analysis and Solutions for Distribution-Level PMUs

Synchrophasors provide promising enhancement to the distribution system monitoring. However, different from transmission systems, distribution systems are usually with higher noise, phase unbalance, and distributed energy resources. All of these could impair the data quality of distribution-level phasor measurement units (D-PMUs) and thus deteriorate the performance of D-PMU based applications. Therefore, the data quality of D-PMU should be evaluated to ensure the effectiveness of D-PMU based applications. In this paper, factors in distribution systems that could jeopardize D-PMU data quality are evaluated. The impact of data quality on D-PMU applications is analyzed. Finally, solutions are proposed to improve D-PMU data quality to satisfy these requirements. This work provides effective methods to improve the performance of distribution-level grid monitoring using synchrophasor measurements.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Injection Locking Dynamics of Oscillation Loop with Saturable Gain

We analytically derive and experimentally verified the injection-locking range and phase-noise suppression ratio of an oscillation loop with saturable gain, establishing a general and straightforward approach for analyzing injection locking dynamics.

Xi, Zichen [ORNL]↗

Long-term hybrid stabilization of the carrier-envelope phase

Controlling the carrier envelope phase (CEP) in mode-locked lasers over practically long timescales is crucial for real-world applications in ultrafast optics and precision metrology. We present a hybrid solution that combines a feed-forward technique to stabilize the phase offset in fast timescales and a feedback technique that addresses slowly varying sources of interference and locking bandwidth limitations associated with gain media with long upper-state lifetimes. We experimentally realize the hybrid stabilization system in an Er:Yb:glass mode-locked laser and demonstrate 75 hours of stabilization with integrated phase noise of 14 mrad (1 Hz to 3 MHz), corresponding to around 11 as of carrier to envelope jitter. Additionally, we examine the impact of environmental factors, such as humidity and pressure, on the long-term stability and performance of the system.

47 OTHER INSTRUMENTATION↗

Ultra-low loss visible light waveguides for integrated atomic, molecular, and quantum photonics

Atomic, molecular and optical (AMO) visible light systems are the heart of precision applications including quantum, atomic clocks and precision metrology. As these systems scale in terms of number of lasers, wavelengths, and optical components, their reliability, space occupied, and power consumption will push the limits of using traditional laboratory-scale lasers and optics. Visible light photonic integration is critical to advancing AMO based sciences and applications, yet key performance aspects remain to be addressed, most notably waveguide losses and laser phase noise and stability. Additionally, a visible light integrated solution needs to be wafer-scale CMOS compatible and capable of supporting a wide array of photonic components. While the regime of ultra-low loss has been achieved at telecommunication wavelengths, progress at visible wavelengths has been limited. Here, we report the lowest waveguide losses and highest resonator Qs to date in the visible range, to the best of our knowledge. We report waveguide losses at wavelengths associated with strontium transitions in the 461 nm to 802 nm wavelength range, of 0.01 dB/cm to 0.09 dB/cm and associated intrinsic resonator Q of 60 Million to 9.5 Million, a decrease in loss by factors of 6x to 2x and increase in Q by factors of 10x to 1.5x over this visible wavelength range. Additionally, we measure an absorption limited loss and Q of 0.17 dB/m and 340 million at 674 nm. This level of performance is achieved in a wafer-scale foundry compatible Si 3 N 4 platform with a 20 nm thick core and TEOS-PECVD deposited upper cladding oxide, and enables waveguides for different wavelengths to be fabricated on the same wafer with mask-only changes per wavelength. These results represent a significant step forward in waveguide platforms that operate in the visible, opening up a wide range of integrated applications that utilize atoms, ions and molecules including sensing, navigation, metrology and clocks.

Chauhan, Nitesh↗

49 W carrier-envelope-phase-stable few-cycle 2.1 µm OPCPA at 10 kHz

We demonstrate a mid-infrared optical parametric chirped pulse amplifier (OPCPA), delivering 2.1 µm center wavelength pulses with 20 fs duration and 4.9 mJ energy at 10 kHz repetition rate. This self-seeded system is based on a kW-class Yb:YAG thin-disk amplifier driving a CEP stable short-wavelength-infrared (SWIR) generation and three consecutive OPCPA stages. Our SWIR source achieves an average power of 49 W, while still maintaining excellent phase and average power stability with sub-100 mrad carrier-envelope-phase-noise and 0.8% average power fluctuations. These parameters enable the OPCPA setup to drive attosecond pump probe spectroscopy experiments with photon energies in the water window.

47 OTHER INSTRUMENTATION↗

RF Digitizer for EIC LLRF

With the shutdown of Relativisitc Heavy Ion Collider (RHIC) in FY26, the former RHIC facility will be upgraded to the new Electron-Ion Collider (EIC). An RF Digitizer for the EIC LLRF system has been developed and tested on a RHIC 197 MHz cavity in Q2 2026 for a baseline per formance. Firmware and software has been developed and validated during the 197 MHz cavity test. Preliminary data from the cavity test shows phase noise performance signifi cantly better than the RHIC LLRF system.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A 1.2-V 6-GHz Dual-Path Charge-Pump PLL Frequency Synthesizer for Quantum Control and Readout in CMOS 65-nm Process

This paper presents a low jitter dual-path chargepump phase locked loop (PLL) synthesizer in a CMOS 65-nm process for quantum readout applications. The PLL incorporates a programmable dual chargepump and a loop filter with both proportional and integral paths that can be driven independently providing flexible control of the loop bandwidth to achieve low jitter performance. The design is implemented at 300 K and critical blocks like voltage-controlled oscillator (VCO) and chargepump (CP) are analyzed at 77 K based on the characterized results. The LC-VCO is realized with the class-C NMOS only architecture with 5-bit coarse control and quadrature signals are generated with poly phase filter. The VCO is designed with the tuning range of 1 GHz around the center frequency of 6 GHz with Phase Noise of -123 dBc/Hz and -132 dBc/Hz at 1MHz offset at 300 K and 77 K temperature. The simulated PLL rms jitter is 125 fs at 6 GHz with a power consumption of 8 mW at the 1.2 V power supply.

47 OTHER INSTRUMENTATION↗

Localization and reduction of superconducting quantum coherent circuit losses

Quantum sensing and computation can be realized with superconducting microwave circuits. Qubits are engineered quantum systems of capacitors and inductors with non-linear Josephson junctions. They operate in the single-excitation quantum regime, photons of $27 \mu$eV at 6.5 GHz. Quantum coherence is fundamentally limited by materials defects, in particular atomic-scale parasitic two-level systems (TLS) in amorphous dielectrics at circuit interfaces.[1] The electric fields driving oscillating charges in quantum circuits resonantly couple to TLS, producing phase noise and dissipation. We use coplanar niobium-on-silicon superconducting resonators to probe decoherence in quantum circuits. By selectively modifying interface dielectrics, we show that most TLS losses come from the silicon surface oxide, and most non-TLS losses are distributed throughout the niobium surface oxide. Through post-fabrication interface modification we reduced TLS losses by 85% and non-TLS losses by 72%, obtaining record single-photon resonator quality factors above 5 million and approaching a regime where non-TLS losses are dominant. [1]M\"uller, C., Cole, J. H. & Lisenfeld, J. Towards understanding two-level-systems in amorphous solids: insights from quantum circuits. Rep. Prog. Phys. 82, 124501 (2019)

Altoé, M Virginia P↗